Abstract
Fire represents one of the most severe hazards encountered by built infrastructure in any urban habitat. It can result from an accidental event viz., short circuiting or as a secondary event following other natural hazards such as earthquakes, explosions, etc. Fires, if not controlled at early stages, can create threatening situations leading to a catastrophe. This can include loss of life, huge property damage contributing to the impaired functionality of existing infrastructure systems, etc. Further, in most of the disastrous seismic events across the world, fire happens to be a significant contributor for the causalities encountered. In addition, post-fire behaviour of structure is necessary for determining the extent of structural damage left behind by a fire event for necessary repair and also for ensuring the safety and integrity of the structure. Hence, a four-storey RC frame building designed according to IS codes located in the city of Warangal, Telangana State has been selected in this study. Thermal analysis of structural components is performed to generate the modified material, and cross-sectional properties for various fire scenarios expressed in terms of exposure times. Finally, the seismic inelastic capacity of the structure is evaluated using nonlinear static analysis for various fire scenarios on the structural models considered. From the results, it can be clearly envisaged that the seismic structural capacity significantly reduces due to a fire hazard and can prove detrimental for survival of the structure in case of prolonged fire hazard. Hence, consideration of fire hazard is necessary to estimate the capacity and in arriving at an appropriate repair/retrofitting strategy for restoring the functionality of the built environment.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
Fire hazard is characterized to be one of the most disastrous events, frequently encountered in urban cities as a primary or as a secondary event. This, if not controlled at early stages, can result in a catastrophe involving huge property damages and loss of life. This disastrous nature is more pronounced in areas of high incidence, coupled with densely populated urban environments. The occurrence of fire inside a building is an unexpected phenomenon and can break out at any time due to various reasons. Conflagrations following the 1906 San Francisco and 1923 Tokyo earthquakes led to serious discussions among engineers about simultaneous safety of buildings against earthquake and fire. The CITF world statistics reported that India loses about 2500 lives annually to fire with highest rate of deaths. Even though the occurrence of building fire is more frequent in comparison with other extreme events like earthquake and hurricanes, etc., it has not been given importance during structural design and detailing. The effect of fire on material properties and on structural members are the two important parameters for proper evaluation of damage of a building due to fire. Experimental studies in literature have reported material strength degradation at higher temperature as a major cause for damages in a fire event. The study of fire and earthquake can be done in two ways—pre-fire earthquake (structure subjected to fire after earthquake) and post-fire earthquake (fire affected structure subjected to an earthquake). The present study focuses on seismic behaviour of building subjected to post-fire earthquake. In reality, the fire leads to material strength deterioration, however, the extent of reduction in strength depends on exposure time and temperature. Moreover, the reduction in overall strength of building is uncertain, and therefore, the assessment of seismic performance of such fire affected structure becomes important. Hence, post-fire behaviour of structure is necessary for determining the extent of structural damage post a fire event, necessary for repair and also for ensuring the safety and integrity of the structure.
Arioz (2007) studied the effect of high temperature on compressive strength of concrete with different types of aggregates and found significant reduction in compressive strength of concrete above 800 °C [1]. Topcu (2008) investigated performance of S220 and S420 reinforcing steel rebars under fire and found significant reduction in tensile strength of rebars above 950 °C [2]. Youssef and Moftah (2007) proposed stress strain model of concrete incorporating effect of temperature [3]. Jau and Hang (2007) studied the effect of non-uniform fire on strength of reinforced concrete column subjected to 2 and 4 h of fire exposure along with axial loading and biaxial bending. Kodur and Dwaikat (2008) developed the mathematical model for predicting the behaviour of reinforced concrete beams subjected to fire with the effect of spalling [4]. Tan and Yao (2004) presented simplified approach for predicting fire resistance of column subjected to different thermal boundary conditions and developed strength reduction factors for steel and concrete subjected to 1-face, 2-face, 3-face and 4-face heating by using SAFIR software tool [5,6,7]. Therefore, assessment of impact of fire hazard on the structural capacity of RC frame building is essential in mitigating this hazard. Hence, four-storey RC frame building perceived to be located in the city of Warangal, Telangana State has been selected to analyse thermal behaviour and post-fire seismic behaviour in this study.
2 Structural Modelling
The structural model considered consists of a regular RC building frame with G + 3, i.e. four storeys of uniform height 3.2 m having two bays with a bay width of 5 m (see Fig. 1). This represents the typical building configuration prevalent in the said location. The building frame has been designed confirming to code provisions of IS 456: 2000 and IS 1893 (Part 1) as located in seismic zone III with medium type of soil [8, 9]. The description of models and the details of loads considered for seismic analysis are given in Table 1 and Table 2, respectively. The structural design details of the model are given in Table 3. The structural modelling is performed using SAP2000, a commercial structural analysis software [10]. The structural elements (beams and columns) were modeled with concentrated plastic hinges, where the beams have only moment (M3) hinges, and the columns have an axial load and a biaxial moment (PMM) hinges as per FEMA 356 (2000) [11]. Additionally, rigid diaphragms were assigned for every storey level throughout the structure ignoring the flexibility of the floor. Mander et al. and Park et al. models were used in characterizing the stress–strain behaviour of concrete and steel rebars, as shown in Fig. 2 [10, 12]. Moreover, as per the recommendations of IS 1893 (2016), moments of inertia of beams and columns were reduced to 35% and 70% for beams and columns, respectively, while performing nonlinear structural analysis.
3 Analysis Methodology
Thermal analysis of the structural model is performed using SAFIR, a thermal analysis software to obtain evolution of temperature within structural components. In addition, modified material properties for the structural components at various elevated temperatures are considered from EUROCODE [14]. Further, section analysis for various fire exposure times (30 and 60 min) with modified material properties is performed using XTRACT software. The outcome is moment rotation and interaction curve, necessary for defining the nonlinear hinge properties of the structural components (i.e. beam and column).
Finally, the pre-fire seismic inelastic capacity of the structure is assessed using nonlinear static analysis (NLS) for various fire scenarios described in terms of exposure times (30 and 60 min) on the structural models considered. The moment rotation and P-M interaction curves obtained from XTRACT software for various fire scenarios are considered as input for seismic behaviour assessment. Nonlinear static (or pushover) analysis is then performed, using the response spectrum specified in IS code for the specified site conditions (Zone III, Medium soil profile) at Warangal city, Telangana state. Pushover analysis is a static, nonlinear procedure in which the magnitude of the structural loading or displacement is incrementally increased in accordance with a certain predefined pattern. The loading is monotonic. With increase in magnitude of loading, weak links of the structures can be obtained. Pushover analysis estimates force and displacement capacity of structure along with sequential formation of hinges in the structure under analysis. The outcome of pushover analysis is usually represented in the form of base force (or base shear) versus roof displacement. This is popularly referred as capacity curve of structure. The outcome of the pre-fire nonlinear seismic analysis is a capacity curve defined in terms of base shear with roof. The overall methodology of the study is depicted as a flowchart in Fig. 3. In general, the seismic behaviour of RC building in terms of typical capacity curves representing original (or stronger) capacity and reduced (or weaker) capacity are shown in Fig. 4.
4 Results and Discussion
4.1 Thermal Analysis
The structural components, i.e. beams and column are first modelled, and their thermal capacities were estimated using SAFIR software. SAFIR performs the transient thermal analysis to determine the temperature distribution in the structure. The thermal profiles of the cross-sections of the structural components are shown in Fig. 5.
The sectional analysis results for the beam and column structural components in terms of moment curvature and interaction diagrams for fire scenarios of 30 min and 60 min duration were performed in XTRACT program. The reduced sectional capacities of the structural components are shown in Figs. 6 and 7.
4.2 Seismic Analysis
The reduced sectional properties of beams and columns obtained from thermal analysis are considered for defining hinge properties at elevated temperatures in the NLS of the structural model as discussed. The outcome of NLS analysis, the capacity curve developed in accordance with FEMA regulations for no fire, 30 min fire exposure and 60 min fire exposure durations is shown in Fig. 8. It can be observed that there is substantial reduction in base shear for the structural model due to fire hazard. This suggests reduction in capacity of the structure due to degradation in exposed material due to fire. Hence, there is an imminent need to assess the structural behaviour considering the effects of fire as it proves detrimental for the survival and functionality of the structure. Therefore, assessment of impact of fire hazard on the structural capacity of RC frame building is essential in mitigating this hazard.
5 Conclusions
Four-storeyed RC building frame is modelled using SAP2000 commercial structural software. The modified material and cross-sectional properties necessary for defining the hinge properties of the structural components due to various fire exposure times (i.e. 30 and 60 min duration) are developed using XTRACT software. Further, the pre-fire seismic behaviour is assessed by performing NLS analysis with modified hinge properties at elevated temperatures. The RC frame buildings are reported to be vulnerable to fire hazard in literature, this observation can be clearly envisaged in the study presented. From the capacity curves developed during nonlinear static analysis for the hypothetical structural model, it can be observed that certain structural components might have incurred damages contributing to reduced seismic capacity.
From this preliminary analysis, it can be concluded that fire hazard has significant effect on reducing the capacity of the structure and proves detrimental for the survival in case of existence of fire for prolonged duration. Hence, structural analysis, post a fire hazard is imminent for appropriate design of repair/rehabilitation measures to restore the functionality of the structure. This aids in building a safe and functional built environment.
References
Arioz O (2007) Effects of elevated temperatures on properties of concrete. Fire Saf J 42(8):516–522
Topcu IB, Karakurt C (2008) Properties of reinforced concrete steel rebars exposed to high temperatures. Mater Sci 2008(814137):1–4
Youssef MA, Moftah M (2007) General stress–strain relationship for concrete at elevated temperatures. Eng Struct 29:2618–2634
Kodur VKR, Dwaikat M (2008) A numerical model for predicting the fire resistance of reinforced concrete beams. Cement Concr Compos 30(5):431–443
Tan KH, Yao Y (2004) Fire resistance of reinforced concrete columns subjected to 1-, 2-, and 3-face heating. J Struct Eng 130(11):1820–1828
SAFIR manual for fire analysis
GID manual for fire analysis
IS 456. Plain and reinforced concrete-code of practice. BIS, New Delhi, India (2000)
IS 1893. Criteria for earthquake resistant design of structures. Part 1 General provision and buildings. BIS, New Delhi, India (2016)
SAP2000, CSi. Analysis reference manual. Computer and Structures Inc., Berkeley (2016)
FEMA 356: pre-standard and commentary for the seismic rehabilitation of buildings. Federal Emergency Management Agency (2000)
Mander JB, Priestley MJ, Park R (1988) Theoretical stress-strain model for confined concrete. J Struct Eng 114(8):1804–1826
Dhir PK, Robin D, Pradip S (2018) Safety assessment of gravity load–designed reinforced concrete–framed buildings. ASCE-ASME J Risk Uncertain Eng Syst Part A Civil Eng 4(2):04018004
European committee for standardisation. Design of concrete structures: general rules: structural fire design. EN 1992-1-2, EUROCODE 2, part 1–2: Brussels (2004)
Acknowledgements
The authors express their gratitude to the Department of Civil Engineering, National Institute of Technology, Warangal for providing laboratory facilities to conduct the work, and the Ministry of Human Resource Development, India for providing fellowship to first and second authors. Also, the authors express their acknowledgment to CSi, New Delhi for extending a standalone license of SAP2000 software for this work.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Oggu, P., Raman, S., Gopikrishna, K. (2022). Effect of Fire Hazard on Seismic Capacity of RC Frame Building. In: Kolathayar, S., Chian, S.C. (eds) Recent Advances in Earthquake Engineering . Lecture Notes in Civil Engineering, vol 175. Springer, Singapore. https://doi.org/10.1007/978-981-16-4617-1_18
Download citation
DOI: https://doi.org/10.1007/978-981-16-4617-1_18
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-4616-4
Online ISBN: 978-981-16-4617-1
eBook Packages: EngineeringEngineering (R0)