The subject of this chapter is radiometric calibration. This is the conversion of the input image values to a common radiometric scale. The transformation to such a scale is of critical importance in image fusion. Without a common radiometric base it is not possible to fuse images which were acquired at different illuminations, or under different atmospheric conditions or captured by different sensors. Radiometric calibration is used in both image fusion and in feature map fusion. For the sake of concreteness, we shall concentrate on the radiometric calibration of two input images A and B.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Burdakov, O., Grimvall, A., Sysoev, O.: Data preordering in generalized PAV algorithm for monotonic regression. J. Comp. Math. 24, 771–790 (2006)
Coltue, D., Bolon, P., Chassery, J.-M.: Exact histogram specification. IEEE Trans. Image Process. 15, 1143–1152 (2006)
Cox, I., Roy, S., Hingorani, S.L.: Dynamic histogram warping of image pairs for constant image brightness. In: Proc. IEEE Int. Conf. Image Process., vol. 2, pp. 366–369 (1995)
Delon, J.: Midway image equalization. J. Math. Imag. Vis. 21, 119–134 (2004)
Heusch, G., Rodriguez, Y., Marcel, S.: Local binary patterns as an image pre-processing for face authentification. In: Proc. FGR (2006)
Holappa, J., Ahonen, T., Pietikainen, M.: An optimized illumination normalized method for face recognition. In: Second IEEE Int. Conf. Biometrics: Theory Appl. Systems (2008)
Li, G., Wang, K.: Merging infrared and color visible images with a contrast enhanced fusion method. In: Proc. SPIE, vol. 6571, p. 657108 (2007)
Nelson, T., Wilson, H.G., Boots, B., Wulder, M.A.: Use of ordinal conversion for radiometric normalization and change detection. Int. J. Remote Sensing 26, 535–541 (2005)
Otsu, N.: A threshold selection method from gray-level histogram. IEEE Trans. Syst. Man Cybernetics 9, 62–66 (1979)
Short, J., Kittler, J., Messer, K.: A comparison of photometric normalization algorithms for face authentification. In: Proc. AFGR (2004)
Verboven, S., Hubert, M.: Libra: A matlab library for robust analysis. Chemometrics and Intell. Laboratory Syst. 75, 127–136 (2005)
Zhuge, Y., Udupa, J.K.: Intensity standardization simplifies brain MR image segmentation. Comp. Vis. Image Under. 113, 1095–1103 (2009)
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Mitchell, H.B. (2010). Radiometric Calibration. In: Image Fusion. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-11216-4_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-11216-4_6
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-11215-7
Online ISBN: 978-3-642-11216-4
eBook Packages: EngineeringEngineering (R0)