Abstract
Multiplex immunoassays allow for the rapid profiling of biomarker proteins in biological fluids, using less sample and labour than in single immunoassays. This chapter details the methods to develop and manufacture a 5-plex immunoassay for the Luminex® platform. Although assay development is not included here, the same methods can be used to covalently couple antibodies to the Luminex beads and to label antibodies for the screening of sandwich pairs, if needed. An example will be given for the analysis of five hormones (glucagon-like peptide 1, growth hormone, insulin, leptin and thyroid-stimulating hormone) in serum samples from schizophrenia patients and controls.
Access provided by CONRICYT-eBooks. Download chapter PDF
Similar content being viewed by others
Keywords
1 Introduction
Schizophrenia patients have a decreased life expectancy due to increased incidence of comorbidities, including insulin resistance and type II diabetes [1]. Although these effects can be brought about by treatment with antipsychotics [2], there is emerging evidence that such metabolic disturbances can also occur in schizophrenia subjects prior to treatment at their first clinical presentation [3]. The bloodstream contains hundreds of bioactive and regulatory proteins including hormones such as insulin and growth hormone which are likely to be involved in these metabolic disturbances. However, most of the polypeptide hormones are present at very low concentrations in the circulation, which necessitates that the biomarker measurement systems used should be highly sensitive. One of the best means for achieving this is through the use of antibody-based approaches like the multiplex immunoassay technique [4]. We showed that this system can be used to simultaneously measure abundant serum proteins such as clotting factors, immunoglobulins and apolipoproteins as well as hormones such as the insulin-related peptides and growth factors, in first onset patients with schizophrenia prior to antipsychotic treatment [5, 6].
Most immunoassays rely on antibodies to capture the protein of interest in a biological matrix such as serum or plasma. Traditional immunoassays are targeted at detecting a single protein and often rely on reactions associated with covalently linked enzymes. New technological developments over the past two decades have now led to the situation where multiple proteins can be detected in a single measurement vessel. The capability of measuring multiple proteins simultaneously maximizes the amount of information that can be obtained from single sample. At the same time, this reduces sample volume requirements and laboratory analysis time and decreases costs. However, multiplexed assays have potential problems that would not be encountered if single assays were used for each individual analyte, as described elsewhere [7]. Examples of these problems include the potential for cross-reactivity and false positives due to antibody interactions. These challenges, if not carefully addressed, can generate misleading results [8,9,10,11,12,13].
The chapter describes the development of a 5-plex immunoassay for the Luminex® system, although the same principles will apply to other similar platforms (Fig. 10.1) [14,15,16,17]. The samples used were serum samples from schizophrenia patients and controls in attempt to gain some insights into the circulating metabolism-related hormones which may be affected in this disorder.
2 Materials
2.1 Samples
-
1.
Serum samples collected from 236 schizophrenia patients and 230 controls (Table 10.1) [6] (see Note 1)
2.2 Bead Conjugation
-
1.
Magnetic separation device
-
2.
Copolymer tubes and labels
-
3.
1–4 mL of magnetic 12.5 × 106 beads/mL Luminex microspheres/beads
-
4.
125 μg/mL monoclonal capture antibodies against glucagon-like peptide 1, growth hormone, insulin, leptin, and thyroid-stimulating hormone (see Note 2)
-
5.
Sulfo-NHS, N-hydroxysulfosuccinimide
-
6.
N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC)
-
7.
Activation buffer: 100 mM NaH2PO4, pH 6.0
-
8.
Coupling buffer: 0.05 M 2-morpholino-ethane-sulfonic acid monohydrate (MES) pH 5.0
-
9.
Blocking/storage buffer: 10 mMNaH2PO4, pH 7.4, 150 mM NaCl, 0.02% Tween 20, 0.1% bovine serum albumin (BSA) and 0.05% NaN3 (PBS-TBN)
2.3 Biotinylation of Detection Antibody
-
1.
Epitope-distinct antibodies (from above) to glucagon-like peptide 1, growth hormone, insulin, leptin and thyroid-stimulating hormone (see Note 2)
-
2.
Sulfo-NHS-LC biotin (ThermoFisher Scientific; Waltham, MA, USA)
-
3.
PBS
2.4 Multiplex Development
-
1.
Assay buffer: PBS, 1%BSA
-
2.
Washing buffer: PBS, 0.02% Tween-20
-
3.
100 μg/mL streptavidin, R-phycoerythrin (SAPE)
-
4.
96-well plate
-
5.
Magnetic separator (see Note 3)
-
6.
Recombinant protein standards for growth hormone, insulin, leptin and thyroid-stimulating hormone
-
7.
Hetorophilic blocking reagents (see Note 4)
3 Methods
3.1 Bead Conjugation
-
1.
Place vials containing 1–4 mL of stock microspheres upright on a flat magnetic separator for 2 min so that the beads can settle (see Note 5).
-
2.
Be careful not to disturb the beads and remove and discard 0.8 mL of buffer for every 1 mL bead stock.
-
3.
Pool the remaining volume into a single copolymer tube.
-
4.
Place tube in the separator for 30–60 s.
-
5.
Remove and discard the supernatant leaving the tube in the separator.
-
6.
Add 0.5 mL activation buffer and suspend the beads by vortexing and sonication.
-
7.
Place in the magnetic separator for 30–60 s.
-
8.
Remove and discard supernatant with the tube in the separator and resuspend in 0.4 mL of activation buffer as above.
-
9.
Add activation buffer to Sulfo-NHS to give a final concentration of 50 mg/mL.
-
10.
Add 50 uL of this solution to the tube and vortex.
-
11.
Add activation buffer to EDC to give a final concentration of 10 mg/mL.
-
12.
Add 50 uL of this solution to the tube and vortex.
-
13.
Incubate 20 min in the dark while rotating at room temperature (see Note 6).
-
14.
Place the tube in the magnetic separator for 30–60 s, remove the supernatant and add 0.5 mL of coupling buffer.
-
15.
Repeat for a total of 2 washes and resuspend in 0.45 mL of coupling buffer.
-
16.
Add 0.2 mL of each capture antibody to five sets of activated microspheres with immediate vortexing (see Note 7).
-
17.
Incubate 2 h in the dark while rotating at room temperature.
-
18.
Place tube in magnetic separator for 30–60 s, remove supernatant and add 1.0 mL of blocking/storage buffer.
-
19.
Resuspend and incubate 30 min with rotation in the dark at room temperature.
-
20.
Place the tube in magnetic separator for 30–60 s, remove the supernatant and wash twice as above with 0.25 mL blocking/storage buffer.
-
21.
Resuspend in 0.25 mL blocking/storage buffer, count the beads with a haemocytometer, adjust to 50 × 106 beads/mL and store at 2–8 °C.
3.2 Biotinylation
-
1.
Prepare a 10 mM solution of the biotin reagent immediately before use.
-
2.
Add 10 mM biotin reagent to the 5 antibody solutions at a 20:1 biotin-antibody molar ratio (see Note 8).
-
3.
Incubate on ice for 2 h (see Note 9).
-
4.
Remove excess biotin by dialyzing the reaction mixture using a minimum of three exchanges into PBS.
-
5.
Add BSA to a final concentration of 1% and a preservative for long-term stability.
3.3 General Protocol
-
1.
Create a capture bead mini-pool by adding 5 μL of each bead solution to a final volume of 1.4 mL assay buffer.
-
2.
Make an 8 standard (S8) mini-pool by adding 0.2 μg of each recombinant protein to a final volume of 0.2 mL assay buffer, and create seven tenfold serial dilutions to generate a standard curve.
-
3.
Make a mini-pool mix of detection antibodies by adding 5 μg of each biotinylated antibody to a final 5 mL assay buffer.
-
4.
Produce 1:5 and 1:10 serial dilutions of serum and plasma samples in assay buffer (see Note 10).
-
5.
Add 30 μL of each standard or sample to different wells of the 96-well plate.
-
6.
Add 10 μL of blocking solution and then add 10 μL of the 5-plex capture beads.
-
7.
Incubate the plate for 1 h on a shaker at room temperature.
-
8.
Wash 3 times with 100 μL wash buffer, add 40 μL of the detection mini-pool to each well and incubate the plate for 1 h on a shaker at room temperature.
-
9.
Add 20 μL SAPE to each well plate, and mix for 30 min on a shaker at room temperature (see Note 11).
-
10.
Wash 3 times with 100 μL wash buffer.
-
11.
Add 100 μL assay buffer.
-
12.
Incubate the plate for 2–5 min on a plate shaker at room temperature.
-
13.
Analyse on the Luminex 100 analyser.
3.4 Data Analysis
-
1.
Carry out data analyses and determine the levels of each hormone in each sample (see Note 12–14).
-
2.
Identify significant differences (P < 0.05) between schizophrenia patients and controls using Student’s t-test for each hormone measurement (Table 10.2).
3.5 Packaging and Use
-
1.
Package all reagents individually in assay buffer using the volumes listed in the general protocol above.
-
2.
Store beads, SAPE, and assay buffer at 4 °C and all other components at −80 °C.
-
3.
Make 2–3 levels of assay quality controls (QC) by spiking recombinant protein into serum samples, and package these individually and store at −80 °C.
-
4.
Screen assay performance and determine assay acceptance criteria by testing a minimum of 20 of each QC in duplicate prior to the next analysis.
4 Notes
-
1.
The protocols of the study were approved by ethical committees from the Universities of Cologne, Muenster, Magdeburg in Germany, and from Erasmus University in the Netherlands [6].
-
2.
For each hormone, one antibody is needed for capture and another for detection, and these should recognize distinct epitopes on the protein. For best results, a monoclonal antibody of high affinity is needed for capture and either a monoclonal or purified polyclonal antibody should be used for detection.
-
3.
A plate washer can also be used.
-
4.
We use Tru-Block from Meridian Life Sciences (Memphis, TN, USA).
-
5.
Prior to coupling or biotinylation of the antibodies, they should be free of any amines and other protein. If using a Tris-based buffer, dialyse the antibody into 1× PBS using a minimum of three buffer exchanges. If the antibody preparation contains stabilizer proteins such as BSA or gelatin, purify with Protein A or Protein G columns, followed by dialysis.
-
6.
The antibodies can be prepared during this incubation.
-
7.
1 mL of microspheres is sufficient for ~40 plates of assays.
-
8.
The molecular weight of immunoglobulin G (IgG) is 150,000 kDa, so the amount of biotin required for a 1 mL of a 1 mg/mL antibody solution could be calculated as follows: 1 mL IgG × 1 mg/mL × 20 mmol biotin/1 mmol IgG × 1 mmol IgG/150,000 mg IgG × 1000 ul/mL= 0.133 mmol biotin = 13 uL of the 10 mM biotin solution.
-
9.
The incubation can also be carried out at room temperature for 30 min.
-
10.
The assay will be multiplex based on the dilution requirement of the samples. In general, if the expected levels are in the pg/mL or low ng/mL range, they will require the same dilution of approximately 1:5 or 1:10.
-
11.
The SAPE concentration will vary with the number of analytes in the multiplex.
-
12.
Carry out curve optimization by varying sample dilutions if required as described previously [7].
-
13.
Carry out blocker optimization using different reagents if required as described previously [7].
-
14.
Assess cross reactivity by comparison of the multiplex results with corresponding single-plex assays if required as described previously [7].
References
Ryan MC, Thakore JH (2002) Physical consequences of schizophrenia and its treatment: the metabolic syndrome. Life Sci 71:239–257
Meyer JM, Davis VG, Goff DC, McEvoy JP, Nasrallah HA, Davis SM et al (2008) Change in metabolic syndrome parameters with antipsychotic treatment in the CATIE Schizophrenia Trial: prospective data from phase 1. Schizophr Res 101:273–286
Spelman LM, Walsh PI, Sharifi N, Collins P, Thakore JH (2007) Impaired glucose tolerance in first-episode drug-naïve patients with schizophrenia. Diabet Med 24:481–485
Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr (1997) Advanced multiplexed analysis with the FlowMetrix system. Clin Chem 43:1749–1756
Schwarz E, Guest PC, Rahmoune H, Harris LW, Wang L, Leweke FM et al (2012) Identification of a biological signature for schizophrenia in serum. Mol Psychiatry 17:494–502
Guest PC, Schwarz E, Krishnamurthy D, Harris LW, Leweke FM, Rothermundt M et al (2011) Altered levels of circulating insulin and other neuroendocrine hormones associated with the onset of schizophrenia. Psychoneuroendocrinology 36:1092–1096
Stephen L (2016) Multiplex immunoassay profiling. Methods Mol Biol 1546:169–176
Todd DJ, Knowlton N, Amato M, Frank MB, Schur PH, Izmailova ES et al (2011) Erroneous augmentation of multiplex assay measurements in patients with rheumatoid arthritis due to heterophilic binding by serum rheumatoid factor. Arthritis Rheum 63:894–903
Fraser S, Soderstrom C (2014) Due diligence in the characterization of matrix effects in a total IL-13 Singulex™ method. Bioanalysis 6:1123–1129
Krika LJ (1999) Human anti-animal antibody interferences in immunological assays. Clin Chem 45:942–956
Jani D, Allinson J, Berisha F, Cowan KJ, Devanarayan V, Gleason C et al (2016) Recommendations for use and fit-for-purpose validation of biomarker multiplex ligand binding assays in drug development. AAPS J 18:1–14
Bastarache JA, Koyama Y, Wickersham NE, Ware LB (2014) Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples. J Immunol Methods 408:13–23
Tighe PJ, Ryder RR, Todd I, Fairclough LC (2015) ELISA in the multiplex era: potentials and pitfalls. Proteomics Clin Appl 9:1862–8354
Tighe P, Negm O, Todd I, Fairclough L (2013) Utility, reliability and reproducibility of immunoassay multiplex kits. Methods 61:23–29
Ellington AA, Kullo IJ, Bailey RK, Klee GG (2010) Antibody-based protein multiplex platforms: technical and operational challenges. Clin Chem 56:186–193
Spindel S, Sapsford KE (2014) Evaluation of optical detection platforms for multiplexed detection of proteins and the need for point-of-care biosensors for clinical use sensors. Sensors (Basel) 14:22313–22341
Marquette CA, Corgier BP, Blum LJ (2012) Recent advances in multiplex immunoassays. Bioanalysis 4:927–936
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer International Publishing AG
About this chapter
Cite this chapter
Stephen, L., Schwarz, E., Guest, P.C. (2017). Multiplex Immunoassay Profiling of Serum in Psychiatric Disorders. In: Guest, P. (eds) Proteomic Methods in Neuropsychiatric Research. Advances in Experimental Medicine and Biology(), vol 974. Springer, Cham. https://doi.org/10.1007/978-3-319-52479-5_10
Download citation
DOI: https://doi.org/10.1007/978-3-319-52479-5_10
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-52478-8
Online ISBN: 978-3-319-52479-5
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)