Objective
During scoliosis surgery damage to the lateral femoral cutaneous nerve (LFCN) has been reported in 20% of patients. The purpose of this study was to characterize intraoperative pressures at the patient cushion interface and examine the LFCN somatosensory evoked potential (SSEP) to determine if there is any correlation to the incidence of LFCN injury.
Material and methods
Three pressure mats (FSA, Vista Medical, Winnipeg) were placed on the Jackson frame before positioning the patient. Data was continuously recorded during surgery and the average and maximum pressures on the chest, left and right hip/thigh region was calculated (Figure 1). The LFCN SSEP was tested by stimulating the anterolateral thigh and recording the evoked potentials over the somatosensory cortex. An increase in latency and/or decrease in SSEP amplitude may be indicative of LFCN dysfunction. At present, data on five patients was recorded. Post-operative evaluation of the front of the iliac crests is performed and the appearance of redness (Figure 2), blisters or pressure sores are documented. Additionally, after surgery, the patients were asked if they feel any numbness on the front of the thighs and manual tests for sensation were performed every day until discharge.
Results
The continuous monitoring was interrupted during electrocautery. The changes in pressure on the chest pads were able to detect cyclic breathing. Increases in pressure were also noted at times such as screw placement or correction. Maximum and average pressure for the five cases is shown in Table 1. LFCN SSEP recordings were variable and the preliminary results are inconclusive. Two patients had numbness in one leg post-op. One of the injuries resolved on day four and the other was still evident on discharge.
Conclusions
Pressure on the LFCN during scoliosis surgery caused numbness in 2/5 patients. Pressure mats were able to record changes during surgery. More data is required to determine if there is any correlation between elevated pressure and LFCN injury.
Consent
Written informed consent was obtained from the patient for the image(s) used in this study. A copy of the written consent is available for review by the Editor of this journal.
Author information
Authors and Affiliations
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Behzadi Fard, N., Krajacic, A., Roy, F.D. et al. Monitoring LFCN damage during scoliosis surgery. Scoliosis 10 (Suppl 1), P28 (2015). https://doi.org/10.1186/1748-7161-10-S1-P28
Published:
DOI: https://doi.org/10.1186/1748-7161-10-S1-P28