Abstract
The hypothesis of this study was that a nondestructive vibrational method could detect bone lysis at the external fixation pin–bone interface prior to current clinical and radiographic methods. In vitro models were used to simulate changes observed during pin loosening in vivo. Fixation pin axial natural frequency decreased with decreasing tensile modulus of the material into which it was implanted. In a live animal study the right tibia of 12 dogs was fractured and stabilized with a four-pin unilateral external fixation frame. The axial natural frequency of each pin was measured and radiographs were taken at 0, 2, 4, 6, 8, and 10 weeks after surgery. The natural frequency did not change when the first radiographic changes around the interface were observed. Pins were palpably stable at this point. As loosening progressed, the natural frequency did decrease. Frequency and quasistatic tests of dissected pin–bone structures revealed a good correlation between natural frequency and pin–bone interface stiffness. In addition, the measurement of natural frequency was more sensitive to bone structure changes at the pin–bone interface than low-load quasi-static stiffness. Therefore, a nondestructive vibration technique could be used instead of low-load quasistatic tests for assessing the pin–bone interface ex vivo.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
REFERENCES
Anderson, M. A., F. A. Mann, C. Wagner-Mann, A. W. Hahn, B. L. Jiang, and J. L. Tomlinson. A comparison of non-threaded, enhanced threaded, and Ellis fixation pins used in type 1 external skeletal fixators in dogs. Vet. Surg.22:482-489, 1993.
Aro, H. T., and E. Y. Chao. Biomechanics and biology of fracture repair under external fixation. Hand Clin.9:531- 542, 1993.
Behrens, F. General theory and principles of external fixation. Clin. Orthop. Relat. Res.241:15-23, 1989.
Clary, E. M., and S. C. Roe. Enhancing external skeletal fixation pin performance: Consideration of the pin-bone interface. Vet. Comp. Orthop. Traumatol.8:1-8, 1995.
Cornelissen, M., F. Burny, G. Van der Perre, and M. Donkerwolcke. Standardized method to measure the fixation quality of a pin. Orthopedics7:623-626, 1984.
Dickens, J. R., D. E. Bray, and R. H. Palmer. An ultrasonic attenuation parameter for investigating the holding power of non-threaded fixation pins in canine femur (in vitro). Ultrasonics32:65-70, 1994.
Fung, Y. C. Biomechanics: Mechanical Properties of Living Tissues, 2nd ed. New York: Springer, 1993, pp. 251.
George, T. F., C. F. Abrams, Jr., D. C. Richardson, D. J. DeYoung, C. S. Carlson, and D. Meutin. Vibrational response analysis: Non-destructive evaluation of ingrowth into porous coated implants. J. Appl. Biomater.3:29-38, 1992.
Hardy, N., F. Burny, and G. A. Deutsch. Pin tract histology study: Preliminary clinical investigations. Orthopedics7:616-618, 1984.
Horn, T. S. The identification of cortical microdamage in fatigue-loaded bone using a non-invasive impulse response vibration testing technique. Bone (N.Y.)14:259-264, 1993.
Kaneko, T. Assessment of the interfacial rigidity of bone implants from vibrational signals. J. Mater. Sci.22:3495- 3502, 1987.
Li, P. L. S., N. B. Jones, and P. J. Gregg. Loosening of total hip arthroplasty. J. Bone Jt. Surg.77:640-644, 1995.
Pettine, K. A., Y. S. Chao, and P. J. Kelly. Analysis of the External Fixator Pin-Bone Interface. Clin. Orthop. Relat. Res.293:18-27, 1993.
Roedlich, C. B. Biomechanical analysis of bone healing in long bone fractures. Ph.D. dissertation, North Carolina State University, 1994.
Rubin, C. T., G. W. Pratt, A. L. Porter, L. E. Lanyon, and R. Poss. The use of ultrasound in vivoto determine acute change in the mechanical properties of bone following intense physical activity. J. Biomech.20:723-727, 1987.
Weinhold, P. S., C. F. Abrams, Jr., S. C. Roe, and J. A. Gilbert. Evaluation of the directional elastic properties of vertebral cancellous bone by non-destructive vibrational analysis. Orthop. Trans.20:534, 1995.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kay, M.W., Roe, S.C., Stikeleather, L.F. et al. Axial Vibration of Threaded External Fixation Pins: Detection of Pin Loosening. Annals of Biomedical Engineering 26, 361–368 (1998). https://doi.org/10.1114/1.92
Issue Date: