1 Introduction

In the late 1990s, gate-commutated thyristors and high-power IGBTs (insulated-gate bipolar transistors) became popular amongst the power switching devices (Lai and Peng 1996; Rodríguez et al. 2002; Bhuvaneswari and Nagaraju 2005), and IGCTs (integrated gate-commutated thyristors) are now extensively used in various applications in drives for medium-voltage control (Mahato et al. 2014), industrial motor control in traction system, chemical industry and oil industry due to ease of gate control, snubberless operation, superior switching characteristics and reduced power losses (Krug et al. 2007). The main objective of the multilevel converter is to synthesize a sinusoidal voltage of several levels obtained from capacitor voltage sources (Wen and Smedley 2008). As the number of levels increases, total harmonic distortion (THD) in the output voltage waveform is reduced, resulting in less switching losses (Al-Othman and Abdelhamid 2009). The multilevel voltage source inverters (VSIs) have recently been used in many industrial, subway applications (Dixon and Morán 2005) and also employed in power quality improvement including HVDC, AC power supplies, static VAR compensators, STATCOM (Sudheer and Prasad 2014), drive systems and renewable energy sources (Abu-rub et al. 2010; Rodríguez et al. 2007, 2009). Basic multilevel inverter is classified as: (1) diode clamped, (2) flying capacitor and (3) cascaded inverter topologies (Malekjamshidi et al. 2014; Franquelo et al. 2008).

Cascaded multilevel converters have (Cheng et al. 2006; Babaei and Moeinian 2010) advantages in terms of capability of fault tolerant, modular structure, minimum number of components and reliability (Lezana and Ortiz 2009; Banaei and Salary 2011). A multilevel cascaded H-bridge (CHB) structure is based on a series connection of several single-phase H-bridge inverters also called cells. The three multilevel converter structures (Rodríguez et al. 2009) such as cascaded H-bridge, neutral point clamped (NPC) and flying capacitor (FC) are capable of generating multilevel output, but they are symmetrical topologies as they are fed by equal DC sources (Colak et al. 2011). Asymmetrical multilevel inverter (MLI) is a modification of existing cascaded H-bridge structure that has advantages mainly in two manners (Hosseinzadeh et al. 2013; Ruiz-Caballero et al. 2009). Firstly, the DC input to asymmetrical multilevel inverter cells is not symmetrical but scaled in some particular ratio (Vazquez et al. 2009). Secondly, all the cells are not equally stressed in terms of power distribution. Some cells carry high power and others low power. Use of hybrid component structure such as IGCTs for high-power cells (generating low-frequency pulses) and IGBTs for lower-power cells (generating high-frequency pulses) is required for economical design (Lu et al. 2010; Rech and Pinheiro 2007). Also, the switching losses can be minimized in asymmetrical multilevel inverters as compared to conventional multilevel inverters by using appropriate PWM method.

An asymmetrical MLI for motor drive (open-end winding IM) system using a high-frequency AC link system (HFL) is presented in Dixon et al. (2010). In (Boby et al. 2016), SVPWM-based MLI for open-end winding IM is proposed to eliminate harmonics voltage (fifth and seventh) for whole modulation range. In conventional V/f control, voltage (stator) is controlled by controlling the DC link voltage at the inverter stage rather than by controlling the DC link voltage at converter stage unlike variable speed induction motor (IM) drives applications like traction drives. However, the fundamental frequency of the inverter can be controlled by the suitable modulation at the inverter stage (Pramanick et al. 2015; Edpuganti and Rathore 2015; Sudharshan et al. 2015). In Chowdhury et al. (2016), a multilevel converter using V/f operation for IM (open-end winding) drive has been presented where floating capacitor bank (half the DC link voltage) using redundant switching states is used to produce the output voltage levels.

Various PWM control strategies such as carrier-based PWM (McGrath and Holmes 2002; Naderi and Rahmati 2008), dual reference phase shifted PWM (Jana et al. 2016), space vector pulse width modulation (SVPWM) technique (Jana and Biswas 2015), selective harmonic elimination (SHE) (Dahidah et al. 2015), synchronous optimal pulse width modulation (Rathore and Edpuganti 2015) and Nearest level control (NLC) has been reported. Nearest level control is a frequently used modulation technique that has been proposed for power distribution in hybrid multicell converter (Perez et al. 2007) used in higher-power, high-level inverter applications (Li et al. 2016; Xiong et al. 2016; Hu and Jiang 2015). NLC has due advantages over SHE as it does not require calculating the firing angles, thus making calculations easier. In SVPWM technique, determining all redundant switching states and the appropriate switching sequences is the most difficult task in comparison with the analysis of NLC as elaborated in Deng and Harley (2015). In Son et al. (2012) and Meshram and Borghate (2015), a round-based nearest level control (NLC) method is demonstrated where the nearest output voltage levels are obtained by converting to the desired output voltage reference and therefore the switching states of inverter are also generated simultaneously.

In this paper, the proposed inverter keeps the entire number of voltage levels for all output voltage amplitude, if the input power source is variable. As no DC source is inherently variable in nature. So the chopper is introduced in the scheme to make the DC source variable. However, the system can also work with variable PWM; but in this case, the nearest level modulation (comparison based or algorithm based) produces voltage levels with distortion and therefore the DC supply is made variable. A novel control scheme called nearest level modulation (NLM) is proposed to realize a nine-level cascaded multilevel converter topology with only a single DC source, and the output voltage step is generated by synthesizing the voltages of both the bridges, i.e. MAIN H-bridge and the auxiliary H-bridge, whereas the switching states are separately generated for both the bridges, i.e. MAIN H-bridge and the auxiliary H-bridge.

2 Principle and Operation

For variable speed operation, the stator voltage (Vs) can be varied in proportion to the inverter frequency (fs) so that the stator flux remains constant using the constant V/f technique. In order to develop enough torque for the induction motor at low-speed operation (Luo et al. 2006), a closed-loop slip speed estimation-based methodology is used. In conventional V/f control techniques, the voltage and frequency are controlled at the inverter stage using a pulse width modulation (PWM) technique (Luo et al. 2006; Wang and Fang 2003). However, in the proposed modulation technique, the voltage is controlled through a DC–DC converter stage and the frequency can be varied at the inverter stage using the nearest level modulation strategy, and the overall block diagram of the proposed methodology for V/f scalar control of induction motor drive is shown in Fig. 1.

Fig. 1
figure 1

Overall block diagram for proposed V/f control technique for the scalar control of induction motor with constant levels of the inverter

At the stator terminals of the three-phase induction motor, the three-phase voltages and currents can be sensed and can be converted to rotating d–q axis components. This allows the decoupling of the stator current into two parts, responsible for flux and torque components. With the known values of torque and stator current in the rotor-oriented frame, the slip speed can be estimated (Wang and Fang 2003) which is further added to the reference speed command to generate the synchronous speed. The gain of the proportional integral (PI) controller is so adjusted that the actual DC link voltage (VDC) equals the DC link command voltage (VDC*) and hence the desired stator voltage can be achieved. For variable speed application, using the above V/f control, a DC link voltage control technique at the DC–DC converter stage is proposed in this paper. The command voltage of the DC–DC converter (VDC*) proportional to the stator frequency (fs) can be used for the closed-loop voltage control. On the other hand, for obtaining the variable frequency operation, the angle command (\(\theta_{\text{e}}\)) can be obtained from the synchronous speed signal (\(\omega_{\text{e}}\)), to generate the three-phase sinusoidal reference signals of unity magnitude for a nine-level asymmetrical inverter. In this proposed asymmetrical MLI configuration, the induction motor should have isolated winding (IW) or open windings as indicated by six lines in the stator terminals as shown in Fig. 1.

The Aux H-bridges operate at low power maximally 16.67% of full drive load. The component list to configure the AC link system contains only one multiwinding transformer, a square wave inverter and some bridge rectifiers made with simple fast recovery diodes. For the asymmetrical operation of inverter, the ratio of transformer primary and secondary windings is kept as 3:1. The MAIN inverter is fed directly by the adjustable DC supply (VDC or 3Vdc), and all the Aux bridges are fed through transformer with reduced amplitude of DC voltage (Vdc). This way, all H-bridges are fed from the adjustable DC supply, and the output voltage is modified by changing the voltage of this DC supply.

2.1 AC Link System

Another main block of power circuit is AC link system. An AC link system, as illustrated in Fig. 2, mainly consists of an H-bridge inverter (square wave generator) and a multiwinding transformer and some fast operating diodes for rectification purpose. The whole modification is done to keep main DC supply to one only. All the Aux bridges (total three) are fed through AC link system as shown in Fig. 2. The variable DC supply after chopper is fed to square wave inverter which converts DC into AC. The square wave inverter is made to operate on fix duty cycle PWM pulses at very high frequency. The output of this inverter is square wave AC output.

Fig. 2
figure 2

Schematic diagram of AC link system using multiwinding transformer

The AC square wave output is fed to the primary side of transformer where the primary and secondary turn ratios of the transformer are kept in scale of three, i.e. 3:1. All the secondary windings maintain the ratio of 3:1. So the output of secondary is also square waves with reduced amplitude of \(V_{\text{dc}}\). Each of these square AC voltages is rectified using simple diode bridges. A simple diode rectifier owes its own unique benefit of absent control circuitry. This will also keep the relation 3:1 at the corresponding DC link voltages, avoiding additional voltage distortion when adjustable DC source is modified.

2.2 Nearest Level Modulation Strategy

The DC voltage of each inverter “n” is defined by \(V_{{{\text{dc}}n}} = m_{n} V_{\text{dc}}\) where \(V_{\text{dc}}\) is a base DC link voltage and \(m_{n}\) is its asymmetry factor. Each inverter n is capable of generating three output voltage levels \(+ \,m_{n} V_{\text{dc}}\), 0 and \(- \,m_{n} V_{\text{dc}}\). The total number of output voltage levels, \(L = 2N + 1\), \(N = \sum\nolimits_{n = 1}^{{N_{\text{cell}} }} {m_{n} }\). When the symmetry is trinary, \(m_{n} = 3m_{n} - 1\), the number of levels is maximum and is given by \(L = 3^{{N_{\text{cell}} }}\).

Figure 3a shows the output voltage level for a two-cell hybrid converter with trinary symmetry \(m_{1} = 3,\;m_{2} = 1\) where the total number of levels, \(L = 9\), has been studied.

Fig. 3
figure 3

a Nearest level modulation technique. b Voltage waveforms and fundamental voltages at each H-bridge

Considering the MAIN inverter with the higher DC link voltage (\(3V_{\text{dc}}\)), the voltage reference is the original modulating signal.

$$V_{r1} = m\sin (\omega t).$$

Comparing the reference signal with the constant value of \(K_{1} \;{\text{and}}\;K_{2}\) generates the switching pattern of the main and auxiliary inverter given by \(K_{1} = \frac{{m_{1} }}{2N},\;K_{2} = \frac{{m_{2} }}{2N}.\)

Then, the switching pattern for the MAIN and Aux inverter is given by the complete algorithm for each “n” inverter cells as

$$\begin{aligned} V_{rn} = \left\{ {\begin{array}{*{20}c} {m\sin (\omega t) \, n = 1} \\ {V_{r(n - 1)} - 2K_{(n - 1)} S_{(n - 1)} \, n > 1 \, } \\ \end{array} } \right\} \hfill \\ {\text{ where }}K_{n} = \frac{{m_{n} }}{2N} \hfill \\ \, S_{n} = (V_{rn} > K_{n} ) - (V_{rn} < - K_{n} ). \hfill \\ \end{aligned}$$

Nearest level modulation for n level is depicted in Fig. 3a, and the formation of nine levels in a phase of load voltage with fundamental voltage waveform is shown in Fig. 3b along with the indication of the load voltage across inverter, main inverter cell and auxiliary inverter cell.

2.3 Proposed Open-Loop V/f Control of IM Based on Stator Decoupled Current

Compared with the superior but complex control, i.e. vector control of induction motor, V/f control is simple and low cost. For low-frequency range of application, the V/f control is not that successful and performance is also not good due to its stator resistance voltage drop and insufficient rotor slip to develop enough torque to drive the motor. A compensation methodology is presented in order to develop enough torque to start the motor with rated load torque at very low frequency (Sudharshan et al. 2015). All the estimations are done in rotor-flux-oriented frame.

2.3.1 Flux Estimator

The flux estimator calculates the estimated values of stator flux components values working along with direct axis and quadrature axis as depicted in Eq. (1). In order to find the flux components, i.e. \(\varPsi_{\text{ds}}^{\text{s}} ,\varPsi_{\text{qs}}^{\text{s}}\), the equations can be written as follows:

$$\left. {\begin{array}{*{20}c} {\varPsi_{\text{ds}}^{\text{s}} = \int \left( {v_{\text{ds}}^{\text{s}} - R_{\text{s}} i_{\text{ds}}^{\text{s}} } \right){\text{d}}t} \\ {\varPsi_{\text{qs}}^{\text{s}} = \int \left( {v_{\text{qs}}^{\text{s}} - R_{\text{s}} i_{\text{qs}}^{\text{s}} } \right){\text{d}}t} \\ \end{array} } \right\}.$$
(1)

After, the stator flux and currents are calculated in stator reference frame; the motor developed electromagnetic torque shown in Eq. (2) can be estimated as,

$$T_{\text{e}} = \left( {\frac{3}{2}} \right)n_{\text{p}} \left( {\varPsi_{\text{ds}}^{\text{s}} i_{\text{qs}}^{\text{s}} - \varPsi_{\text{qs}}^{\text{s}} i_{\text{ds}}^{\text{s}} } \right),$$
(2)

where \(n_{\text{p}}\) = number of poles of machine and \(R_{\text{s}}\) = stator resistance.

2.3.2 Slip Speed Estimator

The slip of an induction machine is the difference between its synchronous speed and rotor speed. At standstill, the slip is 100%, and at the rated frequency, it can be generally 2–5%. To develop the torque by an induction machine, it needs to generate the slip. As the synchronous frequency becomes smaller in the low-speed region, the slip cannot be neglected and needs to be compensated adequately; otherwise, the motor will not be able to develop the sufficient torque to drive the load. The slip \(\omega_{\text{sl}}\) is estimated from the motor torque, \(T_{\text{e}}\). The estimation is done in rotor-flux-oriented frame. The torque and the slip are related as shown in Eq. (3).

$$T_{\text{e}} = \left( {\frac{{n_{\text{p}} }}{{R_{\text{r}} }}} \right)\left( {i_{\text{ds}}^{\text{r}} } \right)^{2} L_{\text{m}}^{2} \omega_{\text{sl}} ,$$
(3)

where \(L_{\text{m}}\) = magnetizing inductance, \(R_{\text{r}}\) = rotor resistance and the slip speed \(\omega_{\text{sl}}\) can be estimated in Eq. (4):

$$\omega_{\text{sl}} = \frac{{T_{\text{e}} R_{\text{r}} }}{{n_{\text{p}} L_{\text{m}}^{2} \left( {i_{\text{ds}}^{\text{r}} } \right)^{2} }}.$$
(4)

In order to implement Eq. (4), the stator current in rotor-flux-oriented frame must be known. In the decoupling control action, the stator current is decoupled in flux and torque component in rotor-flux-oriented frame. For this, the stator current in stator reference frame is converted into rotor-flux-oriented frame. This is done with the help of vector relational operator (vector rotator (VR) or unit vector). It is defined by \(e^{j\theta } .\) The vector rotator converts the rotating frame variables into stationary frame variables, and \(\cos \theta\) and \(\sin \theta\) are the Cartesian components of unit vectors. The \(e^{ - j\theta }\) is defined as inverter vector rotator (VR−1) that converts stationary frame variables into rotating frame variables. The angle θ is the angle associated with the reference frame into which the conversion is being made. Here, in this case, the stationary frame variables are converted to rotating frame variables, and the sine and cosine of the rotor-flux-oriented frame can be obtained by Eq. (5) as follows:

$$\left. {\begin{array}{*{20}c} {\cos \theta_{{\Psi _{\text{r}} }} = \frac{{\Psi _{\text{dr}}^{\text{s}} }}{{\widehat{{\Psi _{\text{r}} }}}}} \\ {\sin \theta_{{\Psi _{\text{r}} }} = \frac{{\Psi _{\text{qr}}^{s} }}{{\widehat{{\Psi _{\text{r}} }}}}} \\ \end{array} } \right\} ,$$
(5)

where

$$\varPsi_{\text{dr}}^{\text{s}} = \frac{{L_{\text{r}} }}{{L_{\text{m}} }}\left( {\varPsi_{\text{ds}}^{\text{s}} - \sigma L_{\text{s}} i_{\text{ds}}^{\text{s}} } \right)\quad L_{\text{r}} = r{\text{otor inductance,}}$$
$$\varPsi_{\text{qr}}^{\text{s}} = \frac{{L_{\text{r}} }}{{L_{\text{m}} }}\left( {\varPsi_{\text{qs}}^{\text{s}} - \sigma L_{\text{s}} i_{\text{qs}}^{\text{s}} } \right),$$
$$\widehat{{\varPsi_{\text{r}} }} = \sqrt {\left( {\varPsi_{\text{dr}}^{\text{s}} } \right)^{2} + \left( {\varPsi_{\text{qr}}^{\text{s}} } \right)^{2} } .$$

Now, with the help of Park transformation, the flux and torque component of stator current in rotor-flux-oriented frame can be obtained as shown in Eqs. (6) and (7):

$$i_{\text{ds}}^{\text{r}} = i_{\text{ds}}^{\text{s}} \cos \theta_{{\varPsi_{\text{r}} }} + i_{\text{qs}}^{\text{s}} \sin \theta_{{\varPsi_{\text{r}} }} ,$$
(6)
$$i_{\text{qs}}^{\text{r}} = - i_{\text{ds}}^{\text{s}} \sin \theta_{{\varPsi_{\text{r}} }} + i_{\text{qs}}^{\text{s}} \cos \theta_{{\varPsi_{\text{r}} }} .$$
(7)

Thus, from the above estimations, the electromagnetic torque, \(T_{\text{e}}\), and the flux component of stator current, \(i_{\text{ds}}^{\text{r}}\), are obtained. So, with the help of Eq. (4), the slip speed \(\omega_{\text{sl}}\) can be found. The block diagram for slip speed estimation is shown in Fig. 4.

Fig. 4
figure 4

Slip speed estimation block diagram

The motor stator terminals three-phase voltages and currents are sensed and, through Clark’s transformation, converted into stationary two-axis components, i.e. direct axis and quadrature axis (dq axis). The torque is estimated from Eq. (2). With the help of Park transformation, the stator current in stationary reference frame is converted into rotor-flux-oriented frame variables. This allows the decoupling of stator current into two parts, responsible for flux and torque components. With the known values of torque and stator current in rotor-oriented frame, the slip speed is estimated which in turn further added to reference speed command to generate synchronous speed. In the next process, the V/f control is applied to generate three-phase sinusoidal reference signals for nine-level asymmetrical inverter. For the scheme to run successfully with proposed asymmetrical inverter structure, the induction motor should have isolated winding (IW) or open-end windings.

3 Simulation and Experimental Results

The simulation results are produced using MATLAB 7.10 (2008a) in co-simulation with PSIM7.05 for modelling the isolated winding (IW) induction motor. The solver discrete (with no continuous states) with fixed step solver type along with 40 μs fixed step size is chosen in MATLAB/SIMULINK configuration parameter. The control scheme comprising stator flux estimation, motor torque estimation, stationary frame variable to rotary frame variable conversion, slip speed estimation, open-loop constant V/f control and three-phase reference signal generation and nearest level control modulation strategy is simulated in MATLAB software.

To fulfil the requirement of variable DC link voltages (3Vdc and Vdc) for MAIN and AUX inverters, input supply to the DC–DC converter (Vs) is considered as 200 V with carrier frequency as 12 kHz and the DC supply voltage (Vs) is adjusted through the DC–DC converter. Hardware set-up of 5 kW, nine-level asymmetrical MLI is built for laboratory purpose to drive an IM (three phases) of rating 1 HP, 200 V, 50 Hz. Simulation and experimental parameters along with the component specifications are mentioned in “Appendix”.

In Fig. 5, the speed command is kept at \(\omega_{\text{ref}} =\) 100 RPM (3.33 Hz). In Fig. 5a, b, the voltage and current waveforms are still distorted, but in voltage waveform, the nine-level output voltage can be counted easily. The ripples in speed are much less in the range of 3–5 RPM as shown in Fig. 5c, d. The stator dq-axis fluxes are 0.75 Wb and frequency changes as per the input speed command.

Fig. 5
figure 5

Simulation results at 100 RPM: a stator terminal one-phase voltage. b Stator one-phase current. c Stator dq-axis flux. d Speed

In Fig. 6, simulation results are recorded for the speed command of \(\omega_{ref} =\) 500 RPM (16.67 Hz). Figure 6a, b clearly depicts that the voltage and current waveforms are improved, respectively. Figure 6c shows that after some speed transients, the rotor speed almost becomes ripples free. The torque waveform also contains lesser ripples as shown in Fig. 6d.

Fig. 6
figure 6

Simulation results at 500 RPM: a stator terminal one-phase voltage. b Stator one-phase current. c Speed. d Torque

Figure 7 shows the simulated waveforms at \(\omega_{ref} =\) 1000 RPM (33.33 Hz). In Fig. 7c, there is an almost negligible overshoot in the speed waveform and it is almost ripple free. The stator terminal R-phase voltage and current waveforms are non-comparably improved and are almost sinusoidal, varying as shown in Fig. 7a, b. The torque waveform with lesser ripples is also shown in the last in Fig. 7d.

Fig. 7
figure 7

Simulation results at 1000 RPM: a stator terminal one-phase voltage. b Stator one-phase current. c Speed. d Torque

It can be stated from Figs. 5, 6 and 7 that, except the low-speed command up to 35–30 Hz, the transient conditions for the waveforms recorded are good and for all the speed command from 1 to 50 Hz, the motor runs very smoothly during steady-state period. All the waveforms have values well within the safe limits. The simulation results are shown for the induction motor at different speed commands from very low speed, i.e. 100 RPM (3.33 Hz) to base speed 1000 RPM (33.33 Hz), but through the proposed control scheme, the motor can be driven well beyond the base speed.

Figure 8 presents the simulation results for the motor speed above rated speed command. The reference speed, this time, is set to \(\omega_{\text{ref}} =\) 1800 RPM (60 Hz). It is clear from the well-known fact that from zero speed up to base speed, motor is controlled under constant V/f control mode which means up to base speed, motor flux remains constant. But, above base speed, the applied voltage to motor is limited to rated value and only frequency is varied further, which brings motor to flux-weakening mode. In Fig. 8a, the voltage becomes constant at rated value but its frequency is changed according to the speed command. The current waveform is shown in Fig. 8b. The motor takes up to 1 s time to follow the command speed but with a different speed other than command speed due to the application of constant load torque (2Nm) as explained earlier and is depicted in Fig. 8c. Again as depicted in Fig. 8d, the torque waveform has the ripples within the range of + 1 to − 1 Nm.

Fig. 8
figure 8

Simulation results at speed 1800 RPM: a stator R-phase voltage. b R-phase current. c Speed. d Torque at 2 Nm

In Fig. 9, the motor is given a speed command of \(\omega_{\text{ref}} =\) 2200 RPM (73.33 Hz) with an application of load torque of 1Nm. As the motor flux weakens more, it takes more time (approximately 2.5 s) to develop the speed. With the application of continuous torque of 1Nm, the motor does not follow the commanded speed exactly. The motor terminal voltage is fixed at rated value as in Fig. 9a at higher frequency as decided by the command speed. Current is well within the safe limits as in Fig. 9b. In Fig. 9c, the speed curve has a dip during the starting period. This is because of the application of load torque from the very start to motor and motor needs enough time to develop the sufficient slip to drive the load. Once it develops the sufficient torque due to production of sufficient slip, it builds the full speed as ordered by command speed. The torque waveform shown in Fig. 9d still has the ripples in the range of 0–2Nm.

Fig. 9
figure 9

Simulation results at speed 2200 RPM: a stator R-phase voltage. b R-phase current. c Speed. d Torque at 1 Nm

For only frequency control, the motor terminal voltage is kept fixed and does not change at different speed commands. This type of control provides a wide range of speed control of induction motor, but this mode of operation leads motor into flux-weakening mode. In Fig. 10a–d, the results are shown for only frequency control speed command at below base speed (100 and 500 RPM) as well as above base speed (1600 and 1800 RPM), respectively. In all the voltage waveforms for the different speed commands, the number of voltage levels remains constant and therefore the nine levels in output voltage are distinctly visible.

Fig. 10
figure 10

Experimental results for only frequency control at below base speed: a 100 RPM. b 500 RPM and at above base speed: c 1600 RPM. d 1800 RPM

For constant V/f control, the motor flux is constant from low-speed region up to rated speed as the V/f ratio is maintained constant. This helps the motor to develop the rated torque at each speed up to base speed. Beyond the base speed, voltage is restricted to rated value and only the frequency is varied. Above rated speed, the motor operates in flux-weakening mode. Experimental results for constant V/f control at below base speed (100 and 500 RPM) as well as above base speed (1800 and 2500 RPM) is shown in Fig. 11a–d, respectively.

Fig. 11
figure 11

Experimental results for constant V/f control at below base speed: a 100 RPM. b 500 RPM and at above base speed: c 1800 RPM. d 2500 RPM

In Fig. 12, the complete inverter hardware set-up driving the 1 HP induction motor load is shown. The input to the inverter is given through the power rectifier module which takes the three-phase AC mains as the input. An auto transformer is inserted between the AC mains and rectifier to supply the controlled DC to the inverter. Figure 13 shows the experimental result of proposed nine-level inverter current at a motor speed of 800 RPM. Three-phase stator current at 800 RPM (frequency is 25.5 Hz) is measured and analysed so that the stator currents are nearly balanced and sinusoidal in nature. Figure 14 shows the simulation results of output phase voltage along with total harmonic distortion (%THD) at different speeds of: (a) 3000 RPM, (b) 1500 RPM, (c) 1000 RPM and (d) 800 RPM using V/f control. It is easily observed that the number of inverter output voltage levels remained the same along with %THD of approximately 9% irrespective of the reference magnitude of the voltage or the speed.

Fig. 12
figure 12

Complete circuit test bench in laboratory

Fig. 13
figure 13

Experimental result of proposed nine-level inverter current at a motor speed of 800 RPM. Current A/L1: X scale = 40 ms/Div; Y scale = 5 A/Div; maximum = 3.22 A; minimum = −3.09 A. Current B/L2: X scale = 40 ms/Div; Y scale = 5 A/Div; maximum = 3.22 A; minimum = −3.09 A. Current C/L3: X scale = 40 ms/Div; Y scale = 5 A/Div; maximum = 3.22 A; minimum = −3.09 A. Cursor values of current A/L1: X1 = 20 ms; X2 = 59.8 ms; dX = 39.8 ms. Y1 = −0.32 A; Y2 = −0.55 A; Dy = −0.23 A

Fig. 14
figure 14

Simulation results of phase voltage of proposed nine-level inverter using V/f control of induction motor at various speeds of: a 3000 RPM, b 1500 RPM, c 1000 RPM, d 800 RPM

4 Conclusion

Cascaded nine-level inverter having different values of input DC voltage source is designed for laboratory prototype. DC–DC converter is employed to achieve constant output voltage levels and harmonics, and nearest level modulation strategy is presented where inverter frequency is varied to control the DC link voltage irrespective of reference voltages. It is understood that from zero to base speed, motor can be controlled under constant V/f control mode and the motor flux remains constant up to base speed, whereas at above base speed, motor can be controlled under only frequency control and motor runs in flux-weakening mode. The simulation results are shown for the induction motor at different speed commands from very low speed, i.e. 100 RPM (3.33 Hz) to base speed 1000 RPM (33.33 Hz). It is worth mentioning from the results obtained from simulation and experimental test bench that at different speeds (above base speed as well as below base speed), the isolated winding or open-end winding induction motor can be driven well with constant voltage level and harmonics with a THD of approximately 9%.