Abstract
S-N inhibitors like thiourea and sewage sludge decomposition gases (SDG) are relatively novel dioxins suppressants and their efficiencies are proven in numerous lab-scale experiments. In this study, the suppression effects of both thiourea and SDG on the formation of dioxins are systematically tested in a pilot-scale system, situated at the bypass of a hazardous waste incinerator (HWI). Moreover, a flue gas recirculation system is used to get high dioxin suppression efficiencies. Operating experience shows that this system is capable of stable operation and to keep gaseous suppressant compounds at a high and desirable molar ratio (S + N)/Cl level in the flue gas. The suppression efficiencies of dioxins are investigated in flue gas both without and with addition of S-N inhibitors. A dioxin reduction of more than 80 % is already achieved when the (S + N)/Cl molar ratio is increased to ca. 2.20. When this (S + N)/Cl molar ratio has augmented to 4.18 by applying suppressant recirculation, the residual PCDD/Fs concentration in the flue gas shrank from 1.22 to 0.08 ng I-TEQ/Nm3. Furthermore, the congener distribution of dioxins is analysed to find some possible explanation or suppression mechanism. In addition, a correlation analysis between (S + N)/Cl molar ratios and PCDD/Fs is also conducted to investigate the chief functional compounds for dioxin suppression.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs, “dioxins”) are unintentionally formed and released from combustion and numerous other thermal processes. Studies have shown that hazardous waste incineration (HWI) is potentially a major source of airborne emissions. Gao et al. (2009) and Lee et al. (2003a, b) estimated the total PCDD/Fs concentration in stack gas samples from HWI, finding that the mean PCDD/F emission is generally higher than the European Union directive emission limit, 0.1 ng I-TEQ/Nm3 (Directive 2000). Therefore, stack gas emissions from hazardous waste incinerators (HWIs) are a serious concern and need appropriate control tools to deal with it.
As the previous research, the formation of PCDD/Fs occurs mainly via heterogeneous reactions at temperatures between 250 and 450 °C in post-combustion regions (Addink et al. 1991; Fangmark et al. 1995; Li et al. 2005; Cunliffe and Williams 2007a, 2009), contributing largely to the dioxin emission (Ballschmiter et al. 1988; Addink et al. 1995; Tuppurainen et al. 1998; McKay 2002). Therefore, it is better to suppress the formation of dioxins in post-combustion regions.
Addition of S-compounds, such as S, Na2S, Na2S2O3, CS2, FeS2, SO3 and SO2, can achieve strong inhibition on dioxin formation (Pandelova et al. 2005; Chang et al. 2006; Yan et al. 2006; Chen et al. 2008a; Jin et al. 2008; Wu et al. 2012). In fact, dioxins could be suppressed when coal with high sulphur is used as fuel (Griffin 1986). Lot of work has been done on the dioxin emissions when waste is incinerated with coal, showing good suppression effects by sulphur compounds (Gullett et al. 1992; Gullett et al. 1998; Gullett et al. 2000a; Chen et al. 2008a). Besides S-containing compounds, some N-compounds (e.g. urea and NH3) are also regarded as effective inhibitors (Tuppurainen et al. 1999; Ruokojârvi et al. 2001; Ruokojârvi et al. 2004; Cunliffe and Williams 2009). Poisoning the catalyst metal has been proven to be the main suppression mechanism for S- and N-compounds (Ruokojârvi et al. 2001; Ryan et al. 2006). In detail, S- or N-compounds could poison some metal chloride into sulphate or metal complexes (Ryan et al. 2006; Shao et al. 2010a; Wu et al. 2012; Tuppurainen et al. 1999; Luna et al. 2000). Moreover, SO2 can also react with Cl2 to form HCl, and the chlorine available for dioxins formation will reduce (Griffin 1986; Gullett et al. 1992). The S- or N-compounds have showed dioxin suppression effects in real-scale experiments, with a reduction efficiency of more than 50 % (Chang et al. 2006; Wu et al. 2012). Therefore, increasing the concentration of S- or N-compounds, namely the value of S/Cl or N/Cl molar ratio, might further increase suppression efficiency.
In recent years, both S- and N-compounds have been observed to strongly suppress the PCDD/Fs formation route via de novo synthesis (Chen et al. 2014). More specifically, high PCDD/Fs inhibition efficiencies of up to 96 % could be achieved by adding 1 wt. % amidosulfonicacid; thiourea and sludge decomposition gases (SDG) could reduce more than 95 % of PCDD/Fs when the (S + N)/Cl molar ratio declines to only 0.47 (Chen et al. 2014; Fu et al. 2015). However, the suppression of dioxins formation by S-N inhibitors has never been explored in a pilot-scale experimental system.
In this study, a 500 Nm3/h capacity pilot-scale system with flue gas recirculation and thermal treatment of filtered ash, designed for the bypass of an actual hazardous waste incinerator (HWI) is used to observe and quantify the suppression effects of S-N inhibitors (Lin et al. 2015). At first, the stability of the pilot-scale system will be checked, by monitoring the concentrations of SO2, NH3 and HCl in flue gas. The corresponding (S + N)/Cl molar ratios will be calculated and analysed. Then the suppression efficiencies of dioxins are also investigated in flue gas without and with addition of thiourea and SDG, respectively. Furthermore, the enhancement of the dioxin suppression effects by recirculating gaseous S-N inhibitors is also studied. In addition, the characteristics of PCDD/Fs and the correlation between (S + N)/Cl molar ratios and PCDD/Fs are further analysed to find some possible suppression mechanism and investigate the main functional gaseous compounds for dioxin suppression.
Materials and methods
The pilot-scale experimental system (PES) in the HWI
The pilot-scale experimental system is carried out in a 50-tonne/day hazardous waste rotary kiln incinerator (Wu et al. 2012; Lin et al. 2014). Emissions of dioxins and others pollutants are controlled by means of the following sequence of operations: quenching tower, acid neutralising tower, activated carbon dosing, baghouse filter, and alkaline scrubber (Fig. 1.). The amounts of activated carbon and lime sprayed into the flue gas are adjusted to 10 and 120 kg/h, respectively. The volumetric flow of flue gas during the experimental stage is about 20,000 Nm3/h and the linear flow velocity is about 7.5 m/s (Table 1).
The PES is mainly composed of a baghouse filter system, a thermal treatment and a flue gas recycling system (Lin et al. 2015). As shown in Fig. 2, the baghouse filter (BF) captures both the fly ash and AC, and then discharges the mixture into the thermal treatment system (inlet A). The filter ash, including fly ash and AC, is then treated at 400 °C under a stream of inert N2 in the thermal treatment unit (TTU), a sealed system excluding any air entries. The gaseous compounds captured by the AC are again desorbed in this TTU. The flue gas recycling system returns the desorbed gaseous phase inhibitors into the flue gas, aspired by a negative pressure to inhibit the formation of PCDD/Fs. During dioxin suppression tests, S-N inhibitors could be added into the TTU to increase the concentration of gaseous phase inhibitors in flue gas.
Table 2 shows the design parameters of the PES. The thermal treatment system is composed of three horizontal tubular furnaces and a horizontal screw conveyer. During the experiment, about 500 Nm3/h of flue gas (450 °C) is introduced from the boiler by an induced fan with a constant rotation rate. The flue gas cools to about 200 °C to simulate the de novo synthesis of dioxins in the bypass flue gas. The retention time of bypass flue gas in the PES is about 35 s. Then AC is injected into the flue gas (at 185 °C) to adsorb PCDD/Fs and SO2 and then it is filtered out by the baghouse filter. The inlet and outlet temperature of the BF system is 170 °C and 150 °C, respectively. Gaseous compounds could be desorbed at 400 °C and recycled into the system (inlet D), where the temperature of the flue gas is about 400 °C.
After thermal treatment, the filtered ash will be discharged from exit B of the TTU. The gas velocity and pressure of the system is 0.35 m/s and −1.0 kPa, respectively. The type of AC is HC 767, produced by Zhejiang Hangmu Timber Industrial Co., Ltd. The particle size of AC is primarily distributed between 10 and 100 μm. The average pore radius and BET surface area is 3.164 nm and 1292 m2/g, respectively.
Experimental setup
The experiments are conducted to study the reduction efficiency of dust and dioxins by baghouse filter and activated carbon in the pilot-scale experimental system (Tests 1 and 2). As shown in Table 3, thiourea and sludge are added into the TTU with a flow rate of 0.25 and 2.5 kg/h to suppress the formation of dioxins in bypass flue gas (Tests 3 and 4). The characteristics of dried sludge used are described in detail in our previous studies (Chen et al. 2014). In Tests 5 and 6, the recycling system is put into use to increase the concentrations of gaseous phase inhibitors to realise a high suppression efficiency of PCDD/Fs formation. The thermal treatment of filtered ash is conducted in the TTU at 400 °C under an inert gas flow of 1 L/min.
Three sampling points (S1, S2 and S3) are setup (Fig. 2.). S1 is set to detect the original PCDD/Fs and gaseous compounds concentration in the flue gas from the waste incinerator. S2 is set to the PCDD/F concentration by de novo synthesis within the 450–200 °C window from S1 to S2 before baghouse filter system, as well as to detect the concentration of gaseous compounds in the recirculating system. S3 is set to detect the emission concentration of PCDD/Fs and gaseous phase inhibitors after the recirculating system. The temperature of S1, S2 and S3 is 450, 200 and 130 °C, respectively. All tests are conducted in duplicate. We conducted each experiment when the system became stable, and the sampling time lasted for 2 h for each run.
Sampling and analysis
A Gasmet detector (FTIR DX-400, Finland) is used to monitor the gaseous compounds in the flue gas, such as SO2, NH3, HCl, NO x and CO.
Dioxin samples in the flue gas are collected by an isokinetic sampler (Model KNJ23, KNJ, Korea) according to US EPA method 23a (Chen et al. 2008a, b). The filtered ash from the exit of the thermal treatment unit is also sampled for dioxin analysis.
The cleanup procedure of PCDD/F samples are according to the US EPA method 23 (for flue gas samples) and 1613 (for fly ash samples), respectively. The PCDD/Fs are identified and quantified by HRGC/HRMS, using a 6890 Series gas chromatograph (Agilent, USA) coupled to a JMS-800D mass spectrometer (JEOL, Japan). A DB-5 ms (60 m × 0.25 mm I.D., 0.25 μm film thickness) capillary column is used for separating the PCDD/Fs congeners. Target compounds are the 17 toxic 2,3,7,8-substituted PCDD/Fs congeners. The mean recoveries of standards for PCDD/Fs range from 55 to 125 %, which are all within the acceptable 25 to 150 % range. Details of cleanup procedure and analysis method of PCDD/Fs could be found in our previous study (Chen et al. 2008a, b; Yan et al. 2012a). The toxic equivalents (TEQ) are calculated using NATO/CCMS factors (Bhavsar et al. 2008). All the concentrations are normalised to dry air, 11 % O2, 1.01 × 105 kPa and 237 K.
Results and discussion
(S + N)/Cl molar ratios in the flue gas
The (S + N)/Cl molar ratios in flue gas are based mainly on the concentrations of SO2, NH3 and HCl, as shown in Fig. 3. In Test 1, the (S + N)/Cl molar ratio is only 0.76. Specifically, the clean gas concentration of SO2, NH3 and HCl is 31.3, 0.4 and 24.7 mg/Nm3, similar with those in our previous study (Lin et al. 2015). After the thermal treatment of bag filter fly ash, the SO2 adsorbed on activated carbon returns to PES, resulting in an incremental rise of SO2 to 44.4 mg/Nm3. However, largely the concentrations of NH3 and HCl do not increase, indicating that they were not adsorbed effectively by activated carbon (Lee et al. 2003a, b; Zhu et al. 2005). As a consequence, the (S + N)/Cl molar ratio went up to 1.08. With addition of thiourea, the concentrations of SO2 and NH3 significantly increase, to 79.2 and 5.1 mg/Nm3, respectively. Moreover, the concentration of HCl little changes during stable operation of HWI. Therefore, the (S + N)/Cl molar ratio could rise to 2.23. After recirculating the gaseous phase inhibitors, the concentration of SO2 and NH3 further increased to 145.6 and 8.6 mg/Nm3, respectively. Finally, the (S + N)/Cl molar ratio continually added up to 4.18.
Continuing to add SDG into PES (Test 5), the concentration of SO2 in the flue gas increased from 31.3 to 60.3 mg/Nm3, and so as to NH3 which also increased from 0.4 to 16.2 mg/Nm3. Normally protein in sludge could be hydrolysed fast to emit NH3, whereas thiourea needs certain amount of oxygen to decompose NH3. However, the content of oxygen in the outlet of the boiler is in the range of 6 to 9 %. Thus, dry sludge is supposed to decompose more NH3 than thiourea (Deng et al. 2009; Yan et al. 2012a; Chen et al. 2014). Because more HCl would be also formed by thermal treatment of dry sludge, the (S + N)/Cl molar ratio only had the same level with that in Test 3. By circulation, the (S + N)/Cl molar ratio could be up to 4.15 with the SO2 concentration of 128.1 mg/Nm3 and also with the NH3 concentration of 23.2 mg/Nm3. Interestingly, the increment of (S + N)/Cl molar ratio for thiourea and SDG seemed to rely on the increasing amount of SO2 and NH3, respectively.
The concentrations of gaseous pollutants in the bypass stack gas are listed in Table 4. With the adsorption effect of activated carbon, the emission of SO2 and NH3 are well below the national emission standards. Due to the incomplete combustion of dry sludge, the concentration of CO increased to more than 50 mg/Nm3 in Tests 5 and 6, while still below the national standards of 80 mg/Nm3. Therefore, the PES did not have further negative effects on the pollutant emissions. However, if more S-N inhibitors are added, desulphurization tower should be introduced into the PES to reduce the emission of SO2 and NH3.
PCDD/Fs suppression by S-N inhibitors
By using the recirculating system, the concentration of PCDD/Fs in the flue gas which has passed through the baghouse filter system with AC injection decreased from 1.22 to 0.84 ng TEQ/Nm3, with a reduction efficiency of 31.1 % (Fig. 4). The result confirmed that dioxin formation would be suppressed when the (S + N)/Cl molar ratio is higher than 1. With addition of thiourea, the concentration of PCDD/Fs in flue gas further decreased to 0.16 ng TEQ/Nm3 and the suppression efficiency is up to 85.2 %, suggesting that SO2 and NH3 are effective dioxin suppressants. The results also revealed that the suppression efficiencies of dioxins in flue gas correlate well with the (S + N)/Cl molar ratios (Anthony et al. 2001; Chang et al. 2006; Wu et al. 2012). After flue gas circulation, the concentration of PCDD/Fs is below the new national standards of 0.1 ng TEQ/Nm3, with a value of 0.08 ng TEQ/Nm3. With addition of SDG, the concentration of PCDD/Fs in the flue gas decreased from 1.22 to 0.24 ng TEQ/Nm3, with a reduction efficiency of 80.3 %. Although the (S + N)/Cl molar ratios for SDG suppression tests are slightly higher than that for thiourea, the suppression efficiencies are lower than the later ones. The reason could be attributed to the different suppression mechanism by SO2 and NH3. In previous studies, SO2 has been proven to have a better suppression effect on dioxin formation than NH3 when they are at the same level (Hajizadeh et al. 2012; Chen et al. 2015). The result confirmed that a relatively high SO2 and NH3 concentration in the flue gas could react with HCl to reduce the chloride availability (Gullett et al. 2000b; Xie et al. 2000; Wikström and Marklund 2001; Yan et al. 2012b) or poison the metal catalyst in the fly ash to reduce the possible formation of dioxins (Ryan et al. 2006; Shao et al. 2010b).
The concentrations of PCDD/Fs in fly ash under different experimental conditions are presented in Fig. 5. By thermal treatment, the concentration of PCDD/Fs in the fly ash decreased from 0.83 to 0.15 ng TEQ/g, with a reduction efficiency of 82.2 %. The degradation and dechlorination effects possibly contributed to the reduction of PCDD/Fs (Weber et al. 2002; Lundin and Marklund 2007; Gao et al. 2008; Song et al. 2008; Wu et al. 2011). Moreover, the degradation efficiency could be affected by temperature, atmosphere, velocity of flue gas and the characteristics of fly ash (Weber et al. 2002; Cunliffe and Williams 2007b; Song et al. 2008; Wu et al. 2011). With addition of thiourea, the concentration of PCDD/Fs in the fly ash decreased to 0.06 ng TEQ/g, indicating that PCDD/Fs could be effectively suppressed even without the application of thermal treatment. By recirculating the gaseous phase inhibitors, the concentration of PCDD/Fs in the fly ash further decreased to 0.03 ng TEQ/g, with a reduction efficiency of 95.9 %. As to the SDG, the concentration of PCDD/Fs could decrease to 0.05 ng TEQ/g when combined with the recycling system. Accordingly, the PCDD/Fs levels of fly ash emitted from PES are well below the Chinese landfill acceptance criteria for waste (3.0 ng I-TEQ/g), showing that PES is an effective system to control the emissions of PCDD/Fs and other chlorinated organic chemicals.
In order to evaluate the emission characteristics of dioxins in different tests, the concept of emission factor is introduced, and its formula is presented below:@@@
- F :
-
emission factor (average value every 4 h)
- C f :
-
concentration of total PCDD/Fs in flue gas after baghouse filter treatment
- V f :
-
volume of flue gas
- C a :
-
concentration of total PCDD/Fs in fly ash collected by baghouse filter
- V a :
-
amount of fly ash emitted per hour.
In this study, the volume of flue gas is 500 Nm3/h and the flow rate of fly ash emitted is 4.0 kg/h. As shown in Fig. 1, the emission factor is 3.93 μg TEQ/h for the blank experiment (Test 1). As shown in Fig. 6, the emission factor decreased to 1.01 μg TEQ/h with a reduction of 74.2 % after accumulating the gaseous phase inhibitors by the recycling system (Test 2). With addition of thiourea (Test 3), the emission factor decreased to 0.34 μg TEQ/h with a reduction of 91.5 %. Hence, the suppression efficiency could reach 95.5 % after the gaseous phase inhibitors recycling (Test 4). With addition of SDG (Test 5), the emission factor decreased to 0.43 μg TEQ/h with a reduction of 89.0 %, which is slightly lower than that of thiourea. A better suppression effect is also detected with the application of the recycling system for SDG, showing a reduction efficiency of 93.7 % (Test 6). Therefore, the dioxin suppression efficiencies could be up to 90 %, and the value could further increase to 95 % after recycling. It means that the reduction amount of dioxins could be 784 g TEQ/year for a 50-tonne/day waste incinerator if it operates 7000 h/year.
Characteristics of PCDD/Fs
The profile of PCDD/Fs is shown in Table 5 for different experimental conditions. In Test 1, the ratios of PCDDs/PCDFs are lower than 1 in both of the flue gas and the filtered ash. This ratio agrees with our previous suppression experiments (Wu et al. 2011; Lin et al. 2014; Lin et al. 2014), suggesting that the low-temperature heterogeneous catalytic formation of PCDD/Fs is the main pathway in the post-combustion regions (Stieglitz et al. 1989; Altwicker et al. 1990; Addink and Olie 1995; Huang and Buekens 1995; Cunliffe and Williams 2009). The ratios of PCDDs/PCDFs in Test 2 did not change so much that the reason could be attributed to the still low levels of gaseous phase inhibitors in flue gas, even with the recycling system. After adding thiourea, the ratio of PCDDs/PCDFs in the flue gas increased, especially in Test 4 where the value increased from 0.27 to 0.52, indicating that S-N inhibitors have a better suppression effect on PCDFs than PCDDs (Chang et al. 2006; Ryan et al. 2006; Aurell and Marklund 2009). However, in Tests 5 and 6, the ratios of PCDDs/PCDFs almost remained the same, and the difference with that of thiourea might be attributed to the composition of S-N inhibitors and also to the different inhibitory effect of SO2 and NH3. Considering the desorption effect, the ratios of PCDDs/PCDFs significantly varied, especially for Tests 4 and 6 (Cunliffe and Williams 2007b). Possibly the PCDFs associated to fly ash are desorbed and destructed in a easier way than PCDDs (Lundin and Marklund 2007). Addink et al. (1995) also obtained similar results and they supposed that PCDDs are more stable than PCDFs.
The rising chlorination degree of PCDDs and PCDFs in flue gas and fly ash indicate that S-N inhibitors exert a better suppression effect on low chlorinated PCDD/Fs (Wikström et al. 1999; Nakahata and Mulholland 2000). This phenomenon could also be attributed to the high vapour pressure for low chlorinated PCDD/Fs, and they could be desorbed more easily than high-chlorinated ones (Chang et al. 2002; Chi et al. 2006; Wu et al. 2011).
The congener distributions of 2,3,7,8-PCDD/Fs are presented in Figs. 7 and 8. The leading PCDD congeners in flue gas and fly ash are both 1,2,3,4,6,7,8-HpCDD and OCDD for Test 1, and the percentage of them is ca. 70 %; the PCDF congeners are relatively homogeneous. After adding the S-N inhibitors and recirculating them in the system, the behaviour of congener profiles trended to be low chlorinated PCDD/Fs, especially for Test 4. Comparison with other tests, the fraction of OCDD decreased in the flue gas of Test 5. The reason could be attributed to the suppression effects of N-compounds (Ruokojârvi et al. 1998, 2004).
Correlation between (S + N)/Cl molar ratios and PCDD/Fs
In order to establish the optimum operating modes and investigate the role of both nitrogen and sulphur compounds in the suppression of PCDD/Fs formation, the relationship between the (S + N)/Cl molar ratio and PCDD/Fs in flue gas and fly ash are analysed. As shown in Fig. 9a, the (S + N)/Cl molar ratio correlates relatively well with PCDDs, PCDFs, PCDD/Fs and TEQ in flue gas (r 2 = 0.72, 0.76, 0.76 and 0.73, respectively). As expected, PCDFs has a better relationship with the (S + N)/Cl molar ratio than PCDDs, indicating that S-N inhibitors have more stable suppression effects on PCDFs in flue gas. In terms of the S/Cl molar ratio, it does not correlate well with PCDDs, PCDFs, PCDD/Fs and TEQ, and their corresponding r 2 values are 0.52, 0.62, 0.60 and 0.56, respectively. For N/Cl, it correlates badly with PCDDs, PCDFs, PCDD/Fs and TEQ, which is similar with the results of S/Cl molar ratio (r 2 values between 0.53 and 0.59). Considering the best relationship between (S + N)/Cl molar ratio with PCDDs, PCDFs, PCDD/Fs and TEQ, S-compounds and N-compounds could have synergistic reaction on dioxin suppressions, which may be the reason for the better suppression effects for S-N inhibitors than S- or N-inhibitors.
The relationship between the (S + N)/Cl molar ratio and PCDD/Fs in fly ash is presented in Fig. 10. Similar with PCDD/Fs in flue gas, the (S + N)/Cl molar ratio correlates relatively well with PCDFs, PCDD/Fs and TEQ in fly ash (r 2 = 0.70, 0.70 and 0.70, respectively). Whereas PCDDs correlates slightly, yet positively with the (S + N)/Cl molar ratio, suggesting that S-N inhibitors could not suppress the formation of PCDDs effectively. The same r 2 values for PCDFs and TEQ indicates that PCDFs contribute most to TEQ, which is accordance with the congener distribution of PCDD/Fs. As to the S/Cl molar ratio, it correlates slightly with PCDFs, PCDD/Fs and TEQ. However, for PCDDs, the corresponding r 2 value is only 0.29. The PCDD-values in flue gas and fly ash refer to different suppression mechanism, while N-compounds are the dominant functional groups for PCDDs in fly ash. Considering the negative correlation between the S/Cl molar ratio and PCDDs it could not follow that the S/Cl molar ratio has no relationship with PCDDs in fly ash, since the desorption effect of PCDD/Fs in fly ash also occurs.
Conclusions
High suppression efficiencies of dioxins are achieved in this pilot-scale system by recirculating and accumulating the gaseous compounds emanating from decomposing S-N inhibitors. This system maintains high concentrations of suppressants in the flue gas so that it reduces PCDD/Fs effectively. With addition of thiourea, the value of (S + N)/Cl in flue gas almost doubled, from 2.23 to 4.18. As for the addition of SDG, the value (S + N)/Cl also amplified, from 2.29 to 4.15. However, these concentrations of SO2, NH3 and NO x etc. all still remain below the national emission standard. By comparison and analysis, thiourea and SDG strongly suppress the formation of PCDD/Fs, even without the use of flue gas circulation, with I-TEQ reductions in flue gas of 85.2 and 80.3 %. Meanwhile, even higher suppression efficiencies could be obtained for dioxins in fly ash, with I-TEQ reductions of more than 92 %. After recirculating the flue gas, the suppression efficiencies of dioxins in flue gas could rise even to 93.6 and 90.8 % for thiourea and SDG, respectively. In terms of the congener distribution of dioxins, the fraction of high-chlorinated PCDD/Fs increased during the suppression tests, indicating that the dechlorination of higher chlorinated PCDD/Fs weakened. Most importantly, correlation analysis suggested that for S-N inhibitors the S-compounds play a more important role in dioxin suppression than N-compounds, and that the suppression mechanism might be different for dioxins in flue gas from that in fly ash.
References
Addink R, Drijver DJ, Olie K (1991) Formation of polychlorinated dibenzo-p-dioxins/dibenzofurans in the carbon/fly ash system. Chemosphere 23:1205–1211
Addink R, Govers HAJ, Olie K (1995) Desorption behavior of polychlorinated dibenzo-p-dioxins dibenzofurans on a packed fly-ash bed. Chemosphere 31:3945–3950
Addink R, Olie K (1995) Role of oxygen in formation of polychlorinated dibenzo-p-dioxins/dibenzofurans from carbon on fly ash. Environ Sci Technol 29:1586–1590
Altwicker ER, Konduri RKN, Milligan M (1990) The role of precursors in formation of polychloro-dibenzo-p-dioxins and polychloro-dibenzofurans during heterogeneous combustion. Chemosphere 20:1935–1944
Anthony E, Jia L, Granatstein D (2001) Dioxin and furan formation in FBC boilers. Environ Sci Technol 35:3002–3007
Aurell J, Marklund S (2009) Effects of varying combustion conditions on PCDD/F emissions and formation during MSW incineration. Chemosphere 75:667–673
Ballschmiter K, Braunmiller I, Niemczyk R, Swerev M (1988) Reaction pathways for the formation of polychloro-dibenzodioxins (PCDD) and -dibenzofurans (PCDF) in combustion processes: II. Chlorobenzenes and chlorophenols as precursors in the formation of polychloro-dibenzodioxins and -dibenzofurans in flame chemistry. Chemosphere 17:995–1005
Bhavsar SP, Reiner EJ, Hayton A, Fletcher R, MacPherson K (2008) Converting toxic equivalents (TEQ) of dioxins and dioxin-like compounds in fish from one toxic equivalency factor (TEF) scheme to another. Environ Int 34:915–921
Chang MB, Cheng YC, Chi KH (2006) Reducing PCDD/F formation by adding sulphur as inhibitor in waste incineration processes. Sci Total Eniviron 366:456–465
Chang MB, Lin JJ, Chang SH (2002) Characterization of dioxin emissions from two municipal solid waste incinerators in Taiwan. Atmos Environ 36:279–286
Chen T, Gu YL, Yan JH, Li XD, Lu SY, Dai HF, Cen KF (2008a) Polychlorinated dibenzo-p-dioxins and dibenzofurans in flue gas emissions from municipal solid waste incinerators in China. J Zhejiang Univ-Sc A 9:1296–1303
Chen T, Yan JH, Lu SY, Li XD, Gu YL, Dai HF, Ni MJ, Cen KF (2008b) Characteristic of polychlorinated dibenzo-p-dioxins and dibenzofurans in fly ash from incinerators in China. J Hazard Mater 150:510–514
Chen T, Zhan MX, Lin XQ, Fu JY, Lu SY, Li XD, Bukens A, Yan JH (2015) PCDD/Fs Inhibition by Sludge Decomposition Gases: Effects of Sludge Dosage, Treatment Temperature and Oxygen Content. Aerosol Air Qual Res 15:702–711
Chen T, Zhan M, Lin X, Li X, Lu S, Yan J, Buekens A, Cen K (2014) Inhibition of the de novo synthesis of PCDD/Fs on model fly ash by sludge drying gases. Chemosphere 114:226–232
Chi KH, Chang SH, Huang CH, Huang HC, Chang MB (2006) Partitioning and removal of dioxin-like congeners in flue gases treated with activated carbon adsorption. Chemosphere 64:1489–1498
Cunliffe AM, Williams PT (2007a) Desorption of PCDD/PCDF from municipal solid waste incinerator flyash under post-combustion plant conditions. Chemosphere 68:1723–1732
Cunliffe AM, Williams PT (2007b) Influence of temperature on PCDD/PCDF desorption from waste incineration flyash under nitrogen. Chemosphere 66:1146–1152
Cunliffe AM, Williams PT (2009) De-novo formation of dioxins and furans and the memory effect in waste incineration flue gases. Waste Manage 29:739–748
Deng WY, Yan JH, Li XD, Wang F, Zhu XW, Lu SY, Cen KF (2009) Emission characteristics of volatile compounds during sludges drying process. J Hazard Mater 162:186–192
Directive EWI (2000) Directive 2000/76/EC of the European Parliament and of the Council on Incineration of Waste European Commission, Brussels
Fangmark I, Strömberg B, Berge N, Rappe C (1995) The influence of fly ash load and particle size on the formation of PCDD, PCDF, PCBz and PCB in a pilot incinerator. Waste Manage Res 13:259–272
Fu J, Li X, Chen T, Lin X, Buekens A, Lu S, Yan J, Cen K (2015) PCDD/Fs’ suppression by sulphur-amine/ammonium compounds. Chemosphere 123:9–16
Gao X, Wang W, Liu X (2008) Low-temperature dechlorination of hexachlorobenzene on solid supports and the pathway hypothesis. Chemosphere 71:1093–1099
Gao HC, Ni YW, Zhao HJ, Zhang N, Zhang XP, Zhang Q (2009) Stack gas emissions of PCDD/Fs from hospital waste incinerators in China. Chemosphere 77:634–639
Griffin RD (1986) A new theory of dioxin formation in municipal solid waste combustion. Chemosphere 15:1987–1990
Gullett BK, Bruce KR, Beach LO (1992) Effect of sulfur dioxide on the formation mechanism of polychlorinated dibenzodioxin and dibenzofuran in municipal waste combustors. Environ Sci Technol 26:1938–1943
Gullett BK, Raghunathan K, Dunn JE (1998) The effect of cofiring high-sulfur coal with municipal waste on formation of polychlorinated dibenzodioxin and polychlorinated dibenzofuran. Environ Eng Sci 15:59–70
Gullett BK, Dunn JE, Raghunathan K (2000a) Effect of cofiring coal on formation of polychlorinated dibenzo-p-dioxins and dibenzofurans during waste combustion. Environ Sci Technol 34:282–290
Gullett BK, Sarofim AF, Smith KA, Procaccini C (2000b) The role of chlorine in dioxin formation. Process Saf Environ 78:47–52
Hajizadeh Y, Onwudili JA, Williams PT (2012) Effects of gaseous NH3 and SO2 on the concentration profiles of PCDD/F in flyash under post-combustion zone conditions. Waste manage 32:1378–1386
Huang H, Buekens A (1995) On the mechanisms of dioxin formation in combustion processes. Chemosphere 31:4099–4117
Jin GZ, Lee SJ, Kang JH, Chang YS, Chang YY (2008) Suppressing effect of goethite on PCDD/F and HCB emissions from plastic materials incineration. Chemosphere 70:1568–1576
Lee WS, Chang-Chien GP, Wang LC, Lee WJ, Tsai PJ, Chen CK (2003a) Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans from the incinerations of both medical and municipal solid wastes. Aerosol Air Qual Res 3:1–6
Lee YW, Kim HJ, Park JW, Choi BU, Choi DK, Park JW (2003b) Adsorption and reaction behavior for the simultaneous adsorption of NO–NO2 and SO2 on activated carbon impregnated with KOH. Carbon 41:1881–1888
Li X, Li Z, Luo LA (2005) Adsorption isotherm and kinetics of dibenzofuran on granular activated carbons. Chinese J Chem 13:701–704
Lin X, Huang Q, Chen T, Li X, Lu S, Wu H, Yan J, Zhou M, Wang H (2014) PCDD/F and PCBz emissions during start-up and normal operation of a hazardous waste incinerator in China. Aerosol Air Qual Res 14:1142–1151
Lin X, Yan Zhan M, Yan M, Dai A, Wu H, Li X, Chen T, Lu S, Yan J (2015) Suppression of dioxins in waste incinerator emissions by recalculating SO2. Chemosphere 133:75–81
Luna A, Amekraz B, Morizur J, Tortajada J, Mó O, Yanez M (2000) Reactions of urea with Cu + in the gas phase: an experimental and theoretical study. J Phys Chem A 104:3132–3141
Lundin L, Marklund S (2007) Thermal degradation of PCDD/F, PCB and HCB in municipal solid waste ash. Chemosphere 67:474–481
McKay G (2002) Dioxin characterisation, formation and minimisation during municipal solid waste (MSW) incineration: review. Chem Eng J 86:343–368
Nakahata DT, Mulholland JA (2000) Effect of dichlorophenol substitution pattern on furan and dioxin formation. P Combust Inst 28:2701–2707
Pandelova ME, Lenoir D, Kettrup A, Schramm KW (2005) Primary measures for reduction of PCDD/F in co-combustion of lignite coal and waste: effect of various inhibitors. Environ Sci Technol 39:3345–3350
Ruokojârvi PH, Halonen IA, Tuppurainen KA, Tarhanen J, Ruuskanen J (1998) Effect of gaseous inhibitors on PCDD/F formation. Environ Sci Technol 32:3099–3103
Ruokojârvi PH, Asikainen A, Ruuskanen J, Tuppurainen K, Kilpinen CM, Pia Yli-Keturi N (2001) Urea as a PCDD/F inhibitor in municipal waste incineration. J Air Waste Manage 51:422–431
Ruokojârvi PH, Asikainen AH, Tuppurainen KA, Ruuskanen J (2004) Chemical inhibition of PCDD/F formation in incineration processes. Sci Total Eniviron 325:83–94
Ryan SP, Li X, Gullett BK, Lee C, Clayton M, Touati A (2006) Experimental study on the effect of SO2 on PCDD/F emissions: determination of the importance of gas-phase versus solid-phase reactions in PCDD/F formation. Environ Sci Technol 40:7040–7047
Shao K, Yan J, Li X, Lu S, Fu M, Wei Y (2010a) Effects of SO2 and SO3 on the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans by de novo synthesis. J Zhejiang Univ-Sc A 11:363–369
Shao K, Yan JH, Li XD, Lu SY, Wei YL, Fu MX (2010b) Inhibition of de novo synthesis of PCDD/Fs by SO2 in a model system. Chemosphere 78:1230–1235
Song GJ, Kim SH, Seo YC, Kim SC (2008) Dechlorination and destruction of PCDDs/PCDFs in fly ashes from municipal solid waste incinerators by low temperature thermal treatment. Chemosphere 71:248–257
Stieglitz L, Zwick G, Beck J, Roth W, Vogg H (1989) On the de-novo synthesis of PCDD/PCDF on fly ash of municipal waste incinerators. Chemosphere 18:1219–1226
Tuppurainen K, Halonen I, Ruokojârvi PH, Tarhanen J, Ruuskanen J (1998) Formation of PCDDs and PCDFs in municipal waste incineration and its inhibition mechanisms: a review. Chemosphere 36:1493–1511
Tuppurainen K, Aatamila M, Ruokojârvi PH, Halonen I, Ruuskanen J (1999) Effect of liquid inhibitors on PCDD/F formation. Prediction of particle-phase PCDD/F concentrations using PLS modelling with gas-phase chlorophenol concentrations as independent variables. Chemosphere 38:2205–2217
Weber R, Nagai K, Nishino J, Shiraishi H, Ishida M, Takasuga T, Konndo K, Hiraoka M (2002) Effects of selected metal oxides on the dechlorination and destruction of PCDD and PCDF. Chemosphere 46:1247–1253
Wikström E, Marklund S (2001) The influence of level and chlorine source on the formation of mono-to octa-chlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls during combustion of an artificial municipal waste. Chemosphere 43:227–234
Wikström E, Tysklind M, Marklund S (1999) Influence of variation in combustion conditions on the primary formation of chlorinated organic micropollutants during municipal solid waste combustion. Environ Sci Technol 33:4263–4269
Wu H, Lu S, Yan J, Li X, Chen T (2011) Thermal removal of PCDD/Fs from medical waste incineration fly ash—effect of temperature and nitrogen flow rate. Chemosphere 84:361–367
Wu H, Lu S, Li X, Jiang X, Yan JH, Zhou M, Wang H (2012) Inhibition of PCDD/F by adding sulphur compounds to the feed of a hazardous waste incinerator. Chemosphere 86:361–367
Xie Y, Xie W, Liu KL, Dicken L, Pan WP, Riley JT (2000) The effect of sulfur dioxide on the formation of molecular chlorine during co-combustion of fuels. Energ Fuel 14:597–602
Yan J, Chen T, Li X, Zhang J, Lu S, Ni M, Cen K (2006) Evaluation of PCDD/Fs emission from fluidized bed incinerators co-firing MSW with coal in China. J Hazard Mater 135:47–51
Yan M, Li X, Yang J, Chen T, Lu S, Buekens A, Olie K, Yan J (2012a) Sludge as dioxins suppressant in hospital waste incineration. Waste Manage 32:1453–1458
Yan M, Qi Z, Li X, Chen T, Lu S, Buekens A, Olie K, Yan J (2012b) Chlorobenzene formation from fly ash: effect of moisture, chlorine gas, cupric chloride, urea, ammonia, and ammonium sulfate. Environ Eng Sci 29:890–896
Zhu J, Wang Y, Zhang J, Ma R (2005) Experimental investigation of adsorption of NO and SO2 on modified activated carbon sorbent from flue gases. Energ Convers Manage 46:2173–2184
Acknowledgments
This work is financially supported by the National Natural Science Foundation (51476138).
Author information
Authors and Affiliations
Corresponding author
Additional information
Responsible editor: Philippe Garrigues
Rights and permissions
About this article
Cite this article
Zhan, MX., Fu, JY., Chen, T. et al. Suppression of dioxins by S-N inhibitors in pilot-scale experiments. Environ Sci Pollut Res 23, 16463–16477 (2016). https://doi.org/10.1007/s11356-016-6401-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-016-6401-2