Abstract
We report direct optical observation of cavitation bubbles in liquid helium, both in classical viscous He I and in superfluid He II, close to the \(\lambda \)-transition. Heterogenous cavitation due to the fast-flowing liquid over the rough surface of prongs of a quartz tuning fork oscillating at its fundamental resonant frequency of \(4\,\mathrm {kHz}\) occurs in the form of a cluster of small bubbles rapidly changing its size and position. In accord with previous investigators, we find the cavitation threshold lower in He I than in He II. In He I, the detached bubbles last longer than one camera frame (10 ms), while in He II the cavitation bubbles do not tear off from the surface of the fork up to the highest attainable drive.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
The understanding of cavitation in both classical and quantum liquids, or more generally—detailed microscopic mechanism of bubble nucleation in them, remains largely an open problem [1], although its phenomenological description in classical viscous liquids [2] is valued for practical engineering purposes. The difficulty of the detailed description of the nucleation mechanism lies in the area between the validity of the continuum hypothesis and the individual particle approach; hence, quantum mechanics has to play an important role not only in quantum fluids but even in the case of classical liquids [3]. To this end, liquid helium offers a unique opportunity to study this problem both in He I, which is a classical low-density liquid possessing very low kinematic viscosity [4], and in He II, which is a quantum liquid exhibiting the two-fluid behavior. One can hope to discern which aspects of cavitation are common and different in classical and quantum liquids, and subsequently, such studies ought to help in developing the detailed microscopic description of the nucleation problem [3].
This work extends our previous investigations of cavitation in liquid helium due to an oscillating quartz fork. In Ref. [5], we have shown that cavitation can easily be detected by monitoring the frequency sweeps across the resonant frequency of the fork, as the electrical response collapses when cavitation occurs. In Ref. [6], the analysis of our results based on the Bernoulli equation in He II suggested pure cavitation, albeit heterogeneous in nature. Moreover, based on the measured temperature dependence of the critical cavitation velocity that steeply increased (from about \(0.6\,\mathrm {m/s}\) to about \(2.1\,\mathrm {m/s}\) for a particular fork) on decreasing temperature within about \(20\,\mathrm {mK}\) below the superfluid transition in the bulk, we concluded that in He I the vicinity of the fork is locally overheated and cavitation occurs here at a higher temperature than that at which the surrounding helium bath is kept. We speculated that the steep increase in the cavitation thereshold just below the superfluid transition can be understood as a consequence of the high convective heat transfer efficiency in superfluid He II compared to He I. This explains why, in accord with the previous observations [1, 5–7], it is more difficult to reach the cavitation in He II than in He I.
Motivated by recent work by Qu et al. [8] reporting differences in the lifetime of bubbles in He I and in He II, in this work we focus on the size and shape of the cavitation bubbles produced heterogeneously by the flow enhancement by excrescences on the surface of the oscillating quartz fork in He I as well as in He II.
2 Experimental Setup
We use our cryogenic optical system for visualizing liquid helium flows by the particle tracking velocimetry [9]. The apparatus consists of a low-loss cryostat with the experimental volume situated at its bottom in a tailpiece of square cross section, with windows for optical access. A pair of pumps can cool the bath along the saturated vapor pressure curve down to \(\sim \)1.3 K. The illumination is realized by a pulsed laser beam defocused by a cylindrical lens into a plane normally illuminating small tracer particles, which are not used in this study. A camera with telemetric lens and \(2\times \) extender has frequency \(100\,\mathrm {Hz}\) and exposure time 9.998 ms (followed by 2 \({\upmu }\)s delay needed for readout and preparing the electronics), and it is positioned perpendicular to the plane illuminated by the laser.
The used quartz tuning fork has the resonance frequency \(f_0 = 4186\,\mathrm {Hz}\) at \(2\,\mathrm {K}\), and the prongs have length \(L = 19.7\,\mathrm {mm}\), width \(W = 2.2\,\mathrm {mm}\) and thickness \(T = 0.8\,\mathrm {mm}\), which are much larger than the viscous penetration depth \(\delta = \sqrt{2\nu /\omega } \approx 1\,\mathrm {\mu m}\). The fork constant, a, which characterizes its geometry and piezoelectric behavior, is measured to be \(a = 3.43\cdot 10^{-5}\,\mathrm {C/m}\) (the meaning of a and its determination can be found in [10]). The fork is situated parallel to the laser plane, with its prongs aiming up with a small deviation of about \(13^\circ \) from vertical direction, see Fig. 1. Note in passing that all presented images are negatives of the captured ones.
The fork is driven by a function generator, and its response is measured by a lock-in amplifier; see Fig. 2. The maximum force we can achieve is \(F = aU \approx 4.4\,\mathrm {mN_{rms}}\). The velocity of the fork can be determined by two ways: (i) The velocity v is proportional to measured current I; \(v = {I}/{a}\), and this method is commonly used; and (ii) we use elongated or “motion-blurred” images of small particles of dust at the surface of the moving fork, which are clearly visible thanks to the side illumination, see Fig. 1. The duration of the laser pulse, \(\sim \)0.4 ms, exceeds one entire fork cycle period, \(0.24\,\mathrm {ms}\). The velocity found this way is slightly (up to about 20%) higher. The discrepancy is, however, not essential here; its most likely reason is either the finite value of the resistor (see Fig. 2) or the specific patterning of the electrodes deposited on the tuning fork.
3 Observations and Discussion
The surprising observation is that there is a cluster of small bubbles instead of one large nearly hemispherical bubble as minimization of the sum of the energy of surface tension and volume Gibbs energy would suggest, see Figs. 3 and 4. Note that although the camera exposure time, \(9.998\,\mathrm {ms}\), is much longer than the fork cycle period, \(0.24\,\mathrm {ms}\), the scene is illuminated only during the laser pulse, i.e., for \(\sim 0.4\,\mathrm {ms}\), corresponding to about 1.7 fork periods. This ensures capturing of the entire fork period, and on the other hand, the captured image is not a superposition of many periods. In He I, we sometimes observe that the bubbles live longer than one cycle; these bubbles then rise up as can be seen in Fig. 5. Such images strongly suggest that the observed bubbles form a real cluster and we do not observe a superposition of different bubbles produced during different fork cycles. In He II, the situation is different in that the bubbles do not tear off from the fork surface up to the highest attainable drive (Fig. 6).
The velocity of the fork versus the driving force is plotted in Fig. 7a. The fork moves fast enough to create the turbulent regime of flow past it, where the drag force \(F_\mathrm{D}\) depends more or less quadratically on the velocity, \(F = F_\mathrm{D} \propto v^2\); see the cases without cavitation in Fig. 7a. When cavitation occurs, the data points lie below this dependence because creation of bubbles consumes energy—this can be qualitatively interpreted as an additional braking force \(F_\mathrm{b}\)—the difference between the applied drive force and the force, which would be needed to obtain the same velocity under the action of hydrodynamic drag force only, i.e., \(F_\mathrm{b} = F - Cv^2\), where the prefactor \(C \approx 5.8\cdot 10^{-3}\,\mathrm {Ns^2m^{-2}}\) is the fitting parameter using the data of Fig. 7a. Note in passing that in He II the maximum energy losses can be carried away to the bulk by thermal counterflow of typical counterflow velocity up to a fraction of mm/s, i.e., much lower than the velocity of moving prongs.
We attempt to quantify the observed bubbles or clusters of bubbles by measuring their area A on each frame (by counting the pixels brighter than a chosen threshold). This leads to an effective radius \(r_\mathrm{{eff}}\), which the bubble would have, assuming its semispherical shape: \(r_\mathrm{{eff}}=\sqrt{{2A}/{\pi }}\). The effective radius of the bubble (or cluster of bubbles) is plotted versus the additional braking force in Fig. 7b. Although there is a visible correlation, the points are too scattered to discern any functional dependence. On the other hand, the reported difference in cavitation properties in He I and in He II is clearly visible: A fixed size bubble produces higher braking force in He II than in He I. The reason of this difference is unclear but might be connected either with the slightly larger surface tension of He II [4] or with quantized vorticity attached to cavitation bubbles.
4 Conclusions
By using the fast optical camera, we have directly observed heterogeneous cavitation in flow of He I and He II due to oscillating quartz fork, on both sides of the \(\lambda \)-transition. Typically, a cluster of small bubbles is produced rather than one bigger hemispherical bubble, and the position, size and shape of such a cluster changes from frame to frame. The produced bubbles are at first look similar in He I and in He II; however, cavitation threshold is lower in He I than in He II. Once nucleated, bubbles live longer in He I than in He II and can rise up in the bulk from the place of their nucleation. Additionally, under otherwise identical conditions the nucleated bubbles brake the motion of the fork’s prongs more in He II than in He I.
References
S. Balibar, J. Low Temp. Phys. 129, 363 (2002)
D.W. Oxtoby, J. Phys. Condens. Matter 4, 7627 (1992)
R.D. Finch, Phys. Fluids 12, 1775 (1969)
R.J. Donnelly, C.F. Barenghi, J. Phys. Chem. Ref. Data 27, 1217 (1998)
M. Blažková, T.V. Chagovets, M. Rotter, D. Schmoranzer, L. Skrbek, J. Low Temp. Phys. 150, 194 (2008)
M. Blažková, D. Schmoranzer, L. Skrbek, Low Temp. Phys. 34, 298 (2008)
H.J. Maris, S. Balibar, M.S. Pettersen, J. Low Temp. Phys. 93, 1069 (1993)
A. Qu, A. Trimeche, P. Jacquier, J. Grucker, Phys. Rev. B 93, 174521 (2016)
M. La Mantia, T.V. Chagovets, M. Rotter, L. Skrbek, Rev. Sci. Instrum. 83, 055109 (2012)
R. Blaauwegeers, M. Blažková, M. Človečko, V.B. Eltsov, R. de Graaf, J. Hosio, M. Krusius, D. Schmoranzer, W. Schoepe, L. Skrbek, P. Skyba, R.E. Solntsev, D.E. Zmeev, J. Low Temp. Phys. 146, 537 (2002)
Acknowledgments
We thank Bohumil Vejr and Martin Jackson for valuable help. We acknowledge the support of the Czech Science Foundation—GAČR 16–00580S; D. D. also acknowledges the support of Charles University—GAUK 1968214 and D. S. also acknowledges institutional support under UNCE 2040.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Duda, D., Švančara, P., La Mantia, M. et al. Cavitation Bubbles Generated by Vibrating Quartz Tuning Fork in Liquid \(^4\)He Close to the \(\lambda \)-Transition. J Low Temp Phys 187, 376–382 (2017). https://doi.org/10.1007/s10909-016-1684-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10909-016-1684-8