Introduction

Devices made of organic materials often consist of several layers, such as electrodes, electron/hole transport layers, and an active layer. Each of these layers is only up to 100 nm thick [1,2,3,4,5]. At this thickness, various surface and interface effects become more pronounced. Energy level compatibility at the organic compound–organic compound (OC–OC) and the electrode–organic compound interface can greatly influence the performance of the devices such as organic light emitting diodes (OLEDs) [6, 7] and organic photovoltaic (OPV) cells [8,9,10]. At small film thickness, the ionization energy and electron affinity level shift can be observed due to the Fermi level alignment between two different materials [11, 12]. Thereby, energy level values obtained from bulky layers cannot be used anymore. Therefore, energy level shift at the both OC–OC and the metal–organic interface is being actively studied [12,13,14,15,16].

Ultraviolet photoelectron spectroscopy (UPS) is a common method for molecule ionization energy determination in thin films [17,18,19]. This method can also be used for the study of the molecule ionization energy shifts at the OC–OC interface [14, 20]. Usually, ionization energy dependence on the layer thickness in planar heterojunction samples is studied. Few attempts have been made to investigate the molecule ionization energy in the bulk heterojunction samples obtained from the solution by the UPS method [21, 22]. Tsoi et al. [22] have investigated pure poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6]-phenyl C61 butyric acid methyl ester (PCBM) films and their blends. Their experimental results showed that there is no P3HT energy level difference between neat and blend films and there is no PCBM contribution on the energy level alignment. Authors explain it with the almost pure P3HT top layer of the blend. UPS sensitivity is only 2–3 nm thickness which means that they have measured mostly P3HT. Guan et al. [23] address the same issue. The problem was solved by lifting off the film from the substrate. In this way, authors obtained the surface that was rich in both donor (P3HT) and acceptor (PCBM) compounds, which is a better representation of the P3HT:PCBM blend. But they had to deal with the substrate influence on the “once-buried surface” energy levels.

Recently, X-ray photoelectron spectroscopy (XPS) has been used as a method for OC–OC interface studies in blend systems. A constant energetic separation between core levels and ionization energy was assumed to obtain ionization energy shift in the blend. Such approach was applied for monolayer and multilayer blend systems of pentacene and phthalocyanine derivatives [24] as well as for P3HT/DFPyC60 film [25]. In the second case, oxygen influence on energy level shift was investigated. Still, XPS method did not show any energy level difference between compounds in the blend (P3HT/DFPyC60) and separate thin films without oxygen in both cases.

Photoemission yield spectroscopy (PYS) could be used as an alternative method for OC–OC interface studies. The method is based on the photoemission yield dependence on photon energy \( (Y(h\nu )) \) [26,27,28]. It offers a possibility to make measurements in the air [28]; however, more precise results could be obtained in a vacuum (~ 10−5 mBar). Compared to the UPS measurements which can be performed only in ultra-high vacuum (< 10−9 mBar), PYS is a less complex and less expensive method. One more and the most important advantage of the PYS method is its scanning depth, which is in the range of tens of nanometers due to the relatively low photon energy (in the range of 4–8 eV) [29]. In comparison, the scanning depth of the UPS is only up to 2–3 nm.

In this work, we have evaluated the applicability and limitations of PYS for OC–OC interface studies in bulk heterojunction samples. Similarly, as in the case of UPS, PYS has been mostly used in the ionization energy measurements of metal and pure organic compound films [27, 30]. Only some research has been done on metal/organic compound [26] or OC–OC interface [31, 32]. P3HT:PCBM bulk heterojunction thin films were chosen as a model system in this study. P3HT ionization energy shift was measured at various mass ratios between P3HT and PCBM. The mass ratio in the system was changed to obtain similar conditions as in planar samples where usually film thickness is varied. P3HT:PCBM system was chosen due to a large amount of research on P3HT and PCBM thin films and their energy level values. Such approach gives a possibility to evaluate the validity of our results and the method itself. Thus far, only pure films of P3HT [33] and PCBM [31] have been studied using PYS. To the best of our knowledge, this method has not been applied to P3HT:PCBM as well as any other bulk heterojunction system thus far.

To study the influence of the sample morphology on the PYS measurements and obtainable results, phase-separated and homogeneously distributed samples were prepared for analyses. Such systems were obtained by using two solvents in the sample preparation: chlorobenzene and chloroform.

Samples made from chloroform were additionally investigated by UPS for comparison with its alternative—PYS method.

Experimental

Studied compounds

In this work, bulk heterojunction samples made from two well-known OPV materials—hole transport polymer P3HT (regioregular, 99.995%, Sigma-Aldrich) and electron transport fullerene derivative PCBM (> 99.5%, Sigma-Aldrich)—were studied. Molecule structure of the studied compounds is shown in Fig. 1.

Figure 1
figure 1

Chemical structure of the studied compounds: a P3HT and b PCBM

Sample preparation

Two series of the bulk heterojunction samples with structure ITO/P3HT:PCBM were prepared on ITO-covered glass substrates (Präzisions Glas and Optik GmbH). In one case, chlorobenzene was used as a solvent, while in the other series chloroform was applied. As the boiling point of chloroform is relatively low (61 °C), it evaporates fast. This rapid evaporation ensures low phase separation of P3HT and PCBM within the bulk of the samples. It leads to the decreased distance between two PCBM molecules as PCBM concentration increases in the system. It would be similar to a decrease in P3HT layer thickness for multilayer samples. On the contrary, the chlorobenzene evaporates slowly as the boiling point of it is relatively high (131 °C). This slow evaporation ensures that phase separation between P3HT and PCBM can occur, and organic compounds are no more homogenously distributed within the bulk of the sample. Therefore, chlorobenzene [34,35,36,37,38] or dichlorobenzene (boiling point of 180 °C) [39, 40] is often used as a solvent in the production of highly efficient P3HT:PCBM solar cells.

Solutions with the concentration of 30 mg ml−1 were prepared. In both series, the samples with the mass ratio between P3HT and PCBM of 1:0 (pure P3HT layer), 1:1, 1:3, 1:5, 1:10, 1:20, and 1:50 were made. The solution was spin coated using Laurell WS–650Sx–GNPP/Lite spin-coater on the ITO-covered glass. Spin-coating parameters were kept unchanged: spinning speed, 400 rpm; acceleration, 400 rpm s−1; spinning time, 40 s. The samples were dried on a hot plate. The samples made from the chloroform solution were heated at 70 °C for 20 min. The samples made from the chlorobenzene solution were dried at 120 °C for 20 min and then additional 10 min at 150 °C. The thickness of all obtained samples was about 300 nm. This thickness was enough to exclude any influence of the ITO/organic compound interface.

The sample morphology was studied by scanning electron microscope Tescan Lyra FE-FIB-SEM.

Photoemission measurements

Photoemission yield spectroscopy measurements were done in a vacuum (pressure of about 10−5 mBar) using a self-built measurement system. ENERGETIQ Laser-Driven Light Source (LDLS EQ-99) was used as a source of ultraviolet radiation. The spectral range of the measurements was between 4 and 6.5 eV. Incident photon energy was changed by diffraction grating monochromator MYM-1 with the step of 0.05 eV. The samples were irradiated through the quartz window of the vacuum chamber. The distance between the sample and electrons collecting electrode was about 2 cm. Keithley 617 electrometer was used as the equipment for electrical current measurements as well as a voltage source. Applying a voltage of 50 V between the sample and the electrode did not change the form of the obtained spectrum but improved signal-to-noise ratio by one order of magnitude. The setup of the measurement system is published elsewhere [41].

Ultraviolet photoelectron spectroscopy measurements were carried out using PHI VersaProbe III. He I lamp with a photon energy of 21.2 eV was used as an excitation source. Ionization energy (I) of the material with respect to the vacuum level is calculated as:

$$ I = h\nu - \left( {E_{\text{SECO}} - E_{\text{LBE}} } \right) $$
(1)

where is excitation photon energy, ESECO is secondary electron cutoff energy, and ELBE is the low binding energy onset.

Results and discussion

Sample morphology

A pure P3HT film made from chlorobenzene was smooth without any structures (not shown here). Other samples made from chlorobenzene solution were different. As the PCBM mass in the sample increased, PCBM crystallites could be observed on the surface of the sample (Fig. 2c, d). When the P3HT:PCBM mass ratio was 1:3, the PCBM crystallites were around 20 μm long (Fig. 2c). When P3HT:PCBM mass ratio was changed to 1:10, PCBM crystallites covered even more of the surface and their size increased to 50–60 μm. Formed crystallites were no more linear but created branch-like structures (see Fig. 2d). It is in contradiction to few previous papers which state that in P3HT:PCBM samples the surface layer is almost pure P3HT due to the lower surface energy of P3HT [21, 22, 42]. Nevertheless, there is a report [43] where result similar to our case was shown. Most likely preparation conditions like annealing temperature could influence PCBM aggregation on the surface. High PCBM concentration and the high annealing temperature can lead to extensive PCBM aggregation on the surface of the sample. This leaves regions around fullerene crystallites to be PCBM depleted. In Fig. 2c, clear contrast between P3HT and PCBM regions can be observed.

Figure 2
figure 2

SEM images of a P3HT sample made from the chloroform solution; b P3HT:PCBM (1:10) sample made from the chloroform; c P3HT:PCBM (1:3) sample made from the chlorobenzene solution; d P3HT:PCBM (1:10) sample made from the chlorobenzene solution. Magnification in all the cases is 1000×

Samples made from chloroform were smooth and without visible structures (Fig. 2a, b). Within the chosen observation range (tens of micrometers), the films seemed to be amorphous where P3HT and PCBM are homogeneously distributed in the bulk of the sample. Even when the mass ratio of P3HT:PCBM was 1:10, no PCBM crystallites could be observed (Fig. 2b). Similarly, samples with higher PCBM concentration were still smooth and without any fullerene crystallites. Fast evaporation of chloroform and relatively low annealing temperature (70 °C) preclude extensive phase separation between P3HT and PCBM. It has been reported that P3HT:PCBM films made from chloroform solution have the surface roughness of around 1 nm and aggregates in the range of a couple of tens of nanometers [44].

Ionization energy measurements

Photoemission yield Y() can be calculated as:

$$ Y\left( {h\nu } \right) = {{I\left( {h\nu } \right)} \mathord{\left/ {\vphantom {{I\left( {h\nu } \right)} {P\left( {h\nu } \right)}}} \right. \kern-0pt} {P\left( {h\nu } \right)}} $$
(2)

where I() is the number of emitted electrons and P() is the number of incident photons with the energy of \( h\nu \). In threshold region, a relation between photoemission yield Y() and ionization energy Eioniz can be expressed as a power law:

$$ Y\left( {h\nu } \right) = \alpha \left( {h\nu - E_{\text{ioniz}} } \right)^{n} $$
(3)

where α is constant showing amplitude of the signal and n = 1…3 depending on studied materials [45]. n = 2 is used in the case of metals [30, 46], while n = 2.5 or n = 3 is used in the case of semiconductors [14, 26, 27]. In this work, we have used n = 2.5 as it gave better approximation than n = 3.

Bulk heterojunction samples made from chlorobenzene

To obtain ionization energy value Eioniz from photoemission yield measurements, Y2/5() is calculated and plotted depending on photon energy. Then, the linear part of Y2/5() curve is extrapolated till Y2/5() = 0. Cross-sectional point with the x-axis is considered to be the ionization energy of the studied compound (Fig. 3).

Figure 3
figure 3

Photoemission yield spectra of bulk heterojunction samples depending on P3HT:PCBM mass ratio. Samples made from chlorobenzene solution

For all the samples made from chlorobenzene solution, the photoelectron emission signal was obtained only from P3HT with an insignificant influence of PCBM (see Fig. 3). Even when the mass ratio of P3HT:PCBM was 1:10, no notable signal coming from PCBM was observed. This could be explained by two effects. First, in our previous research, we observed that signal created by pure PCBM film at the photon energy of 6.50 eV is at least one order of magnitude lower than signal created by pure P3HT film [32]. It might be related to the difference in hole mobility of the studied compounds—P3HT is hole conducting material, while PCBM is electron conductor. Second, the ionization energy of PCBM is close to 6.00 eV [32], but the ionization energy of P3HT is close to 4.50 eV (see Fig. 3). It means that UV radiation with photon energy just above 6.00 eV can ionize only small part of PCBM molecules, while it is almost 1.50 eV over the ionization threshold energy of P3HT. Thus, polymer molecules can be easily ionized. The combination of these two effects can “hide” any PCBM influence on the photoemission signal.

In all the cases obtained ionization energy value of P3HT was the same (IP3HT = 4.54 ± 0.03 eV), which matches the energy value of the pure P3HT sample. The signal of measurements is a sum of two separate signals [26, 47]: in our case the signal created by the molecules at the interface and the signal created by the molecules within the region of pure P3HT. It seems that in this case most of the signal comes from the bulky part of the P3HT and not the OC–OC interface. It means that phase-separated samples made from chlorobenzene even at high PCBM concentrations cannot be used for P3HT:PCBM interface studies due to the small amount of the molecules at the P3HT/PCBM interface compared to the molecules at regions of pure P3HT. To observe interface effects, we need as many P3HT molecules as possible at the interface with PCBM.

Bulk heterojunction samples made from chloroform

To increase the number of molecules at the OC–OC interface, series of the samples were made from chloroform solution. As discussed in “Sample preparation” section, the fast evaporation of chloroform precludes extensive aggregation of P3HT and PCBM within the bulk of the sample.

Photoemission yield spectrum and the ionization energy of pure P3HT sample made from chloroform were the same as for the sample made from chlorobenzene (see Fig. 4): IP3HT = 4.54 ± 0.03 eV. It means that there is no distinguishable influence of used solvents and thermal annealing on the energy levels of P3HT.

Figure 4
figure 4

Photoemission yield spectra of P3HT thin films made of chlorobenzene and chloroform solution

Photoemission yield spectra of P3HT:PCBM samples made from chloroform solution are shown in Fig. 5. At the P3HT:PCBM mass ratio of 1:1, the ionization energy of P3HT still remained the same as in the case of a bulky P3HT layer: IP3HT = 4.54 ± 0.03 eV. Our obtained bulky layer ionization energy level values are in good agreement with the values obtained by UPS. While we have obtained values of 4.54 ± 0.03 eV for P3HT, Tsoi et al. report values of 4.60 eV [22]. P3HT molecule ionization energy level shifts to a higher value when PCBM molecule concentration increases (see Fig. 5). When the P3HT:PCBM mass ratio was 1:50, the ionization energy of P3HT had shifted by more than 0.40 eV to the higher energy and reached IP3HT = 4.96 ± 0.03 eV. It means that at the interface there is a higher difference between ionization energy of P3HT and electron affinity energy of PCBM than just comparing bulk values. P3HT ionization energy dependence on P3HT:PCBM mass ratio is shown in the inset of Fig. 5. Energy shift could be attributed to either interface dipole or Fermi level alignment. It has been reported that interface dipole between P3HT and PCBM can create vacuum level shift of around 0.50 eV [23, 48]. While it is in good agreement with our obtained energy shift value of 0.40 eV, still it cannot explain continuous threshold energy shift depending on P3HT:PCBM mass ratio. It has been reported that already 0.5-nm-thick film is enough to reach maximum vacuum level shift at metal/organic interface in PYS measurements [26]. If the situation is similar in the case of OC–OC interface, P3HT:PCBM mass ratio of 1:3 or 1:5 should be enough to observe constant vacuum level shift. Further increase in the PCBM concentration should only increase the number of PCBM molecules close to the interface, instead of increasing interface dipole. On the other hand, the continuous IP3HT shift depending on P3HT:PCBM mass ratio could be caused by the Fermi level alignment at the OC–OC interface. When the PCBM concentration in the film increases, the number of P3HT molecules close to the OC–OC interface increases. It would be similar to the planar heterojunction where the thickness of P3HT layer would decrease. The closer the molecule is to the interface, the more the energy levels will shift due to the alignment of Fermi levels. As the distance from the interface increases, obtained ionization energy will be closer to the value of the bulk material.

Figure 5
figure 5

Photoemission yield spectra of bulk heterojunction samples depending on P3HT:PCBM mass ratio. Samples made from chloroform solution. Inset: P3HT ionization energy depending on P3HT:PCBM mass ratio

Signal decrease at higher PCBM concentration is related to the decreased number of P3HT molecules in the scanned layer. Only when the mass ratio of P3HT and PCBM was 1:20 and 1:50, signal coming from PCBM could be observed. In these cases, the measured spectrum is a sum of two separate spectra [47]:

$$ Y\left( {h\nu } \right) = x\left( {h\nu - I_{\text{P3HT}} } \right)^{{{\raise0.5ex\hbox{$\scriptstyle 5$} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{$\scriptstyle 2$}}}} H\left( {h\nu - I_{\text{P3HT}} } \right) + y\left( {h\nu - I_{\text{PCBM}} } \right)^{{{\raise0.5ex\hbox{$\scriptstyle 5$} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{$\scriptstyle 2$}}}} H\left( {h\nu - I_{\text{PCBM}} } \right) $$
(4)

where IP3HT and IPCBM are ionization energies of P3HT and PCBM, respectively, x and y are constants showing relative signal intensity coming from each of the compounds, H(E) is Heaviside step function. In both of these cases, the obtained ionization energy of PCBM was the same: IPCBM = 6.15 ± 0.03 eV. This value is in good agreement with our previously reported value for thin (below 12 nm) PCBM layer on top of the P3HT film [32]. It means that despite the high concentration of PCBM, electrons are obtained from PCBM molecules that are close to P3HT molecules.

UPS measurements for bulk heterojunction samples made from chloroform

The same samples made from chloroform were investigated by UPS method to compare both photoemission methods: UPS and PYS. Obtained ionization energy for P3HT in these measurements is IP3HT,UPS = 4.6 ± 0.1 eV and does not depend on P3HT:PCBM mass ratio (see Fig. 6). This value is in good agreement with the ionization energy value of thin P3HT films obtained using PYS (IP3HT = 4.54 eV). As shown in Fig. 6, for the samples where the P3HT:PCBM mass ratio was 1:3–1:50, we can observe increasing signal created by PCBM molecules. At the same time, P3HT signal is clearly diminished. Here, the ionization energy of PCBM is IPCBM,UPS = 5.9 ± 0.1 eV. This value is close to the previously reported value of IPCBM,UPS = 5.8 eV [22, 23]. The obtained ionization energy value of P3HT and PCBM corresponds to the values of bulky materials instead of molecules at the OC–OC interface. This could be due to the low scanning depth of UPS combined with less homogeneously distributed compounds at the surface of the sample. UPS spectra of the samples with P3HT:PCBM mass ratio of 1:3, 1:10, and 1:50 are almost identically close to the secondary electron cutoff. Although there is a clear difference in the spectra between pristine P3HT sample and P3HT:PCBM samples, no secondary electron cutoff energy (ESECO) shift between pure P3HT sample and P3HT:PCBM samples was observed. The shift of the secondary electron cutoff (high binding energy cutoff) is considered to be related to the vacuum level shift, caused by the interface dipole. In our experiment (Fig. 6), it cannot be observed. It fits the results obtained by PYS, where we concluded that the observed energy level shift could be related to the Fermi level alignment rather than vacuum level shift.

Figure 6
figure 6

UPS spectra depending on P3HT:PCBM mass ratio showing secondary electron cutoff and low binding energy onset. Energy scale is shown with respect to the P3HT vacuum level

Conclusions

We have shown that the photoemission yield spectroscopy is a suitable method for organic compound–organic compound interface studies using bulk heterojunction samples. An important condition for the successful experiment is a poor phase separation of organic compounds within the bulk of the sample. It ensures that dominant signal is created by the OC–OC interface.

Our experiment showed that by lowering the portion of P3HT in the sample, the ionization energy of polymer shifted toward the ionization energy value of PCBM from 4.54 to 4.96 eV. This could be mostly related to the alignment of Fermi levels of P3HT and PCBM.

In the UPS measurements, the samples made from chloroform solution showed energy level shift neither for P3HT nor for PCBM. The obtained ionization energy of P3HT and PCBM was similar to the value of bulk materials.

As it was shown, both methods (UPS and PYS) had the same problem: PCBM could not be observed until extreme cases where the fullerene derivative mass portion in the sample was over 80%. Further research concerning signal amplitude created by each compound should be done.