Abstract
Colloids act as vectors for pollutants in groundwater, thereby creating a series of environmental problems. While managed aquifer recharge plays an important role in protecting groundwater resources and controlling land subsidence, it has a significant effect on the transport of colloids. In this study, particle size and zeta potential of colloidal humic acid (HA) have been measured to determine the effects of different hydrochemistry conditions. Column experiments were conducted to examine the effects on the transport of colloidal HA under varying conditions of pH (5, 7, 9), ionic strength (<0.0005, 0.02, 0.05 M), cation valence (Na+, Ca2+) and flow rate (0.1, 0.2, 0.4 ml/min) through collectors (glass beads) to model the properties and quality of artificial recharge water and changes in the hydrodynamic field. Breakthrough curves showed that the behavior of colloidal HA being transported varied depending on the conditions. Colloid transport was strongly influenced by hydrochemical and hydrodynamic conditions. With decreasing pH or increasing ionic strength, a decrease in the peak effluent concentration of colloidal HA and increase in deposition could be clearly seen. Comparison of different cation valence tests indicated that changes in transport and deposition were more pronounced with divalent Ca2+ than with monovalent Na+. Changes in hydrodynamic field (flow rate) also had an impact on transportation of colloidal HA. The results of this study highlight the need for further research in this area.
Résumé
Les colloïdes agissent comme des vecteurs de polluants dans les eaux souterraines, créant ainsi une série de problèmes environnementaux. Alors que la recharge artificielle d’aquifère joue un rôle important dans la protection des ressources en eaux souterraines et la surveillance des affaissements du sol, elle a un effet significatif sur le transport des colloïdes. Dans cette étude, la taille des particules et le potentiel zeta de l’acide humique colloïdal (HA) ont été mesurés afin de déterminer les effets de différentes conditions hydrochimiques. Des essais en colonnes ont été réalisés pour examiner les effets sur le transport de l’HA colloïdal pour des conditions variables de pH (5, 7, 9), de force ionique (<0.0005, 0.02, 0.05 M), de valence des cations (Na+, Ca2+) et de vitesses d’écoulement (0.1, 0.2, 0.4 ml/min) par le biais de collecteurs (perles de verre) pour modéliser les propriétés et la qualité de l’eau de recharge artificielle et les modifications du domaine hydrodynamique. Les courbes de restitution ont montré que le comportement de l’HA colloïdal transporté variait en fonction des conditions. Le transport colloïdal est fortement influencé par les conditions hydrochimiques et hydrodynamiques. Avec une diminution du pH ou une augmentation de la force ionique, une diminution dans la concentration de l’HA colloïdal au niveau du pic de l’effluent et une augmentation des dépôts peuvent clairement être observées. Une comparaison des tests pour des valences différentes des cations indique que les modifications dans le transport et le dépôt sont plus prononcées avec le Ca2+ bivalent qu’avec le Na+ monovalent. Les changements dans le domaine hydrodynamique (débit d’écoulement) ont également un impact sur le transport de l’HA colloïdal. Les résultats de cette étude soulignent la nécessité de poursuivre les recherches dans ce domaine.
Resumen
Los coloides actúan como vectores de contaminantes en el agua subterránea, creando de esta manera una serie de problemas ambientales. Mientras el manejo de la recarga de acuíferos juega un papel importante en la protección del agua subterránea y el control de la subsidencia del terreno, tiene un efecto significativo en el transporte de los coloides. En este estudio, se midieron el tamaño de partícula y potencial zeta del ácido húmico coloidal (HA) para determinar los efectos de diferentes condiciones hidroquímicas. Los experimentos de columna se llevaron a cabo para examinar los efectos sobre el transporte coloidal del HA en diversas condiciones de pH (5, 7, 9), de la fuerza iónica (<0.0005, 0.02, 0.05 M), de valencia de los cationes (Na+, Ca2+) y de caudal (0.1, 0.2, 0.4 ml/min) a través de los colectores para modelar las propiedades y la calidad del agua de la recarga artificial y de los cambios en el campo hidrodinámico. Las curvas de ruptura mostraron el comportamiento variado del transporte de los HA coloidales dependiendo de las condiciones. El transporte coloidal está fuertemente influenciado por las condiciones hidroquímicos e hidrodinámicas. Con la disminución de pH o fuerza iónica creciente, una disminución en la concentración del pico coloidal de HA del efluente y el aumento de la deposición podría ser visto claramente. La comparación de diferentes pruebas de valencia del catión indica que los cambios en el transporte y la deposición fueron más pronunciados con el divalente Ca2+ que con el monovalente Na+. Los cambios en el campo hidrodinámico (caudal) también tuvieron un impacto en el transporte de HA coloidal. Los resultados de este estudio ponen de relieve la necesidad de una mayor investigación en esta área.
摘要
胶体作为地下水中污染物的向量,从而产生一系列环境问题。当管理的含水层补给在保护地下水资源和控制地面沉降发挥重要作用时,它对胶体的运移也有重大的影响。在本项研究中,测量了胶体腐殖酸(HA)的粒径和界达电位以确定不同水文化学条件的应影响。进行了土柱试验,以检查pH (5,7, 9), 离子强度(<0.0005, 0.02, 0.05 M), 阳离子化合价(Na+, Ca2+)及通过收集器(玻璃珠)的流量(0.1, 0.2, 0.4 ml/min)不同条件下对胶体腐殖酸的影响,模拟人工补给水的特性和质量以及水化学场变化。突破曲线显示,运移的胶体腐殖酸的特性根据情况不同有很大变化。胶体运移受到水化学和水动力学条件的强烈影响。随着pH降低及离子强度的增加,可以清楚地看到胶体腐殖酸流出物峰值浓度降低及沉积增加。不同阳离子化合价试验对比表明,用二价Ca2+实验时的运移和沉积变化比用一价Na+试验时更显著。水动力场(流量)变化对胶体腐殖酸的传输也有影响。这项研究的成果突出了本领域进一步研究的需求。
Resumo
Coloides atuam como vetores para poluentes nas águas subterrâneas, criando desta forma uma série de problemas ambientais. Enquanto a recarga gerenciada de aquíferos desempenha um papel importante na proteção dos recursos hídricos subterrâneos e controlam a subsidência do terreno, tem um significante efeito no transporte de coloides. Neste estudo, o tamanho da partícula e o potencial zeta do ácido húmico (AH) coloidal foi medido para determinar os efeitos de diferentes condições hidroquímicas. Experimentos colunares foram conduzidos para examinar os efeitos do transporte do AH coloidal sob diferentes condições de pH (5, 7, 9), força iônica (<0.0005, 0.02, 0.05 M), valência de cátion (Na+, Ca2+) e taxa de fluxo (0.1, 0.2, 0.4 ml/min) através de coletores (contas de vidro) para modelar as propriedades e qualidade da água de recarga artificial e mudanças no campo hidrodinâmico. Curvas de identificação mostraram que o comportamento do AH coloidal sendo transportado varia dependendo das condições. Transporte de coloide foi fortemente influenciado pelas condições hidroquímicas e hidrodinâmicas. Com redução do pH ou aumento da força iônica, uma diminuição no pico da concentração residual do AH e aumento na deposição podem ser claramente observados. Comparação de diferentes testes de valência de cátions indicam que o transporte e deposição foi mais pronunciado com o Ca2+ bivalente do que com o Na+ monovalente. Mudanças no campo hidrodinâmico (vazão) também teve um impacto no transporte de AH coloidal. Os resultados deste estudo destacam a necessidade de mais estudos nesta área.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Groundwater is an important component of water resources, and is widely used for irrigation, industrial and domestic water supply. Many environmental problems such as land subsidence, land collapse, and saltwater intrusion, have been caused by groundwater over-exploitation (Huang et al. 2012). Managed aquifer recharge is an effective means to solve these problems (Zhang et al. 2015). The water used during managed aquifer recharge has variable chemical and physical properties, which results in changes in the hydrochemistry and hydrodynamics of groundwater (Vanderzalm et al. 2010).
Colloidal science began in the first part of the 19th century. Colloidal contaminant transport is recognized as an important aspect of this science (Lvjiajun 2013); indeed, failure to consider colloid-facilitated contaminant transport will result in an underestimation of the transport range of contaminants (McGechan and Lewis 2002; Thorsten et al. 2014). There may be a wide variety of inorganic, organic, and microbiological colloids in the subsurface (McCarthy and Zachara 1989). Colloids facilitate the transport of a wide variety of adsorbed contaminants over significant distances (Jonge et al. 2004). Colloids have a strong contaminant adsorption capacity, and affect the rate of contaminant migration (Kretzschmar et al. 1999); thus, colloid transport in the subsurface may result in enhanced contaminant transport. To obtain an improved insight into the influence of subsurface contaminant transport by colloids, an understanding of the transport and deposition of colloids through porous media is needed. The first step in studies of colloid-facilitated contaminant transport is therefore to gain an insight into the migration behavior of the individual colloids.
A considerable number of studies have examined the transport and deposition of colloids in porous media (Liu et al. 1995). The transport of colloids in groundwater is a very important part of this research, but artificial colloids such as carboxylated latex were mostly used in these experiments (Yan et al. 1995). In this study, natural humic acid (HA) was chosen, which originates from decayed plants and animals widely found in subsurface water. Humic acid, an organic compound or macromolecule, is widespread in aquifers because of its unique properties, and has a substantial effect on the transport of subsurface chemicals (Gao et al. 2011; Zhu et al. 2014). It contains hydrophilic aromatic rings linked by carbon chains with different functional groups including carboxyls, phenols, and alcohols (Parent and Velegol 2004). It associates easily with metal ions, minerals, and bacteria through surface interactions because of its high specific surface area, large number of negative charges, and abundant functional groups.
Many studies have shown that the physicochemical properties of colloidal HA can vary depending on the pH and ionic strength of the suspension (Balnois et al. 1999; Parent and Darrell 2014). The factors that control colloidal HA transport and fate in the subsurface have also been explored in many column experiments—for example, in their recent study, Yamashita et al. (2013) used column experiments to explore the influence of a wide range of monovalent and divalent electrolyte concentrations and found that ionic strength had a significant effect on colloidal transport, especially on divalent cations. Other researchers have conducted similar studies (Sojitra et al. 1995). While some studies have explored the transport of colloidal HA, there is still a need for a deeper insight into the transport of colloidal HA in subsurface environments during managed aquifer recharge.
The physicochemical properties of colloidal HA and its transportation are affected by pH, ionic strength (IS), and flow rate. However, there is a lack of information about the transport and deposition of colloidal HA during managed aquifer recharge. A systematic understanding on the colloidal HA transport in porous media under different hydrochemical and hydrodynamic conditions is still lacking. Therefore, the objective of this study was to use a laboratory model to investigate the influence of hydrochemistry and hydrodynamic conditions on the transport and deposition of colloids in porous media during managed aquifer recharge. The recharge water used in managed aquifer recharge varies, and may comprise sources such as rainfall runoff, base flow from rivers, and purified wastewater. During the recharge process, the groundwater quality will be influenced by introduced colloids and intimal colloids. It is particularly important therefore to have reliable information about how individual colloids behave during managed aquifer recharge. In this investigation, a suspension was prepared in the laboratory to better control the hydrochemistry conditions of simulated recharge water. The influent suspension with varying conditions simulates different hydrochemistry conditions of recharge water. Flushing with deionized water was used to study the colloidal HA release process when the water chemistry conditions change; in addition, different hydrodynamic conditions were simulated by varying flow rates.
Materials and methods
Experimental materials
Porous media
The study used spherical glass beads, sieved with an average diameter of 0.45 mm, with a net negative charge as the model medium to eliminate uncertainties in the transport behavior of colloidal HA through porous media caused by heterogeneity and differing interface properties in natural soil. The glass beads had a chemical composition of 75.29 % SiO2, 13.26 % Na2O, 7.15 % CaO, and 4.30 % MgO by weight, and did not react chemically with the solutions. The zeta potential of the glass beads stored in deionized water at pH 7 was –18.94 mV.
Before filling the column, the glass beads were soaked in 0.1 M NaOH(aq) for about 3 h to remove surface impurities, rinsed with deionized water until the pH of the effluent became stable; they were then further soaked with 0.1 M HNO3(aq) for about 3 h, and then washed with deionized water until the pH of the effluent became stable. The glass beads were dried in an oven at 105 °C and stored in sterile beakers before being packed in the columns.
Colloidal HA
Colloidal HA, namely Suwannee River HA (SRHA) standard II, purchased from the International Humic Substance Society (Colorado, USA) was used as colloid particles in the column transport experiments. The composition and hydrochemical properties of the SRHA are shown in Table 1 (Hong and Elimelech 1997).
A 20-mg aliquot of dry HA was introduced into 100 ml of MilliQ deionized water (Millipore, Bedford, Massachusetts, USA), and sonicated for 30 min to disperse the HA uniformly. The pH of the suspension was 4.5. Based on the concentration level, total organic carbon in groundwater, and the chemical composition of HA, the preparation of colloidal HA in suspension was diluted to 10 mg/L, and stored in the dark at 4 °C and re-sonicated before use.
Solution chemistry
The transport of colloidal HA in porous media was examined under different pH and ionic strength conditions. The pH was adjusted from 4.5 to 5, 7, and 9 by adding NaOH(aq). The inorganic compounds NaCl(aq) and CaCl2(aq) were used as electrolytes to adjust the ionic strength of the suspension from 0 to 0.02 M and 0.05 M to study the effect of concentration of electrolytes and cation types. The suspensions were then sonicated again and stored at 10 °C to simulate subsurface conditions. Deionized water was used as the aqueous solvent.
Experimental apparatus and method
Column transport experiment apparatus
Column experiments were conducted in glass chromatography columns with an effective length of 6.0 cm and an internal diameter of 3.2 cm. The columns were packed with glass beads and were saturated with deionized water from bottom to top to minimize air entrapment. The estimated porosity of the porous medium measured by weight method ranged from 0.40 to 0.45. A filter membrane was fixed at both ends of the columns to prevent leaching of the glass beads. A peristaltic pump (BT-100, Longer Pump, Baoding, China) was used to pump influent solution through the column at a default constant speed of 0.2 ml/min. An ultraviolet spectrophotometer (UV-1800, SHIMZU, Japan) connected to a PC and with a flow cell at a wavelength of 212 nm was used to monitor the temporal variations in the concentration of colloidal HA in the effluent. The colloid concentration-absorbance standard curve of the relationship between absorbance and the concentration of the colloidal HA was used to calculate the change in the concentrations of colloidal HA. Finally, the column effluents were collected in an automatic fraction collector at fixed time intervals of 30 min to confirm the concentration of total organic carbon in the effluent and to verify the reliability of the experimental data. To simulate the groundwater environment, the column and the experimental solution were kept in a fridge at 10 °C, and all the experiments were finished under saturated conditions. The experimental setup is shown in Fig. 1.
Experimental method
Column transport experiments were conducted to determine the effect of hydrochemical and hydrodynamic conditions on the transport and deposition behavior of colloidal HA in saturated porous media. Four sets of column experiments were carried out to determine the effect of:
Before each experiment, the porous medium was saturated by continually injecting with deionized water from bottom to top at a constant low rate of 0.2 ml/min (corresponding to a Darcy velocity of approximately 0.9 m/d) without allowing any air to enter for 24 h until the pH of the effluent was stable. It should be noted that the Darcy velocity is representative of field conditions.
When the columns were saturated, tracer experiments with a 10 mg/L potassium iodide solution were conducted in each group. Iodide ions were completely conserved against the surface of glass beads and were detectable at a wavelength of 280 nm by the ultraviolet spectrophotometer, and the tracer showed identical optimal breakthrough behavior. Tracer experiments also determined the PV from breakthrough curves (BTCs) of 15 ml (Kretzschmar et al. 1997).
A two-stage column test was performed for experiments 1–3. Four PV colloidal HA suspensions (stage 1) were injected at 0.2 ml/min. A three-way valve was then used to quickly replace colloidal HA solution with deionized water. This was introduced upwards into the column at the same flow rate (stage 2). This period lasted for 21 PV until there were no colloids in the effluent.
In experiment 4, the influence of flow rate on colloidal HA was determined. A 4 PV colloidal HA suspension was injected at rates of 0.1, 0.2, and 0.4 ml/min for each group of experiments, and then replaced with deionized water for 21 PV until there were no colloids in the effluent.
Colloidal deposition rate coefficient
According to the first-order deposition kinetics theory and the convection-diffusion formula, a colloid deposition rate coefficient (K) is needed to calculate the amount of colloidal HA deposition in the column. This coefficient was determined according to Eq. (1) (Elimelech et al. 2000):
where U is the flow rate (m/s), ε is the porosity of the porous medium (dimensionless), L is the effective length of the column (m), and \( \frac{C}{C_0} \) corresponds to the proportion of the colloids that were recovered in the effluent after the breakthrough curve had reached a plateau.
Results and discussion
Characterization of colloidal humic acid
The size and zeta potential are of importance for determining the stability of colloidal HA. In this study, the major particle size and zeta potential of the colloidal HA were thus detected under different pH (5, 7, 9) and ionic strength conditions (0, 0.02, 0.05 M) in NaCl and CaCl2 solutions by a zetasizer (Malvern Zetasizer, Nano ZS, Malvern, UK). The results are presented in Table 2.
Zeta potential of the colloidal humic acid
The stability of colloidal HA in suspension has a significant influence on colloid transport and adsorption behaviors in porous media. The zeta potential of the colloidal HA was detected in triplicate at the experimental conditions by a zetasizer. The colloidal HA with abundant functional groups and is negatively charged. The results show that the negative zeta potential of HA was −17.8 mV when the pH was 5 and more negative as the pH increased from 5 to 9 for an IS of 0. Only carboxylic groups will be dissociated under acidic and neutral conditions; however, as the pH increases, both carboxylic and phenolic groups will be dissociated under alkaline conditions. In contrast, as the ionic strength increases at pH 7.0 the absolute zeta potential decreases, compression of the electrostatic double layer at higher ionic strengths results in decreases in both the electrostatic repulsive and the stability, and aggregation is likely to occur (Torkzaban et al. 2008).
Size of colloidal humic acid
Previous research results (Alvarez-Puebla and Garrido 2005) showed that particle size of colloidal HA varied under different conditions, and that it had an influence on the stability and aggregation in the suspension. Changes in pH had an obvious influence on particle size (Fig. 2). When the pH was 5 (acidic conditions), the majority of HA had a particle size of around 259.8 nm; when the pH was adjusted to 7, it was about 300.8 nm, and was larger than that in acid conditions; when the pH increased to 9, it was 448.4 nm. This is because with increasing pH, the particle size also increases, because of the dissociation of functional groups. Besides, changes in ionic strength also had an effect on the particle size (Fig. 3), when the ionic strength was adjusted from 0 to 0.05 M with NaCl, the particle size increased from 300.8 to 432.7 nm; when the ionic strength was adjusted with CaCl2, the particle size increased sharply from 300.8 to 641.1 nm. Small basic units that occur individually at low ionic strength interconnect together at high ionic strength. Besides, divalent cations (Ca2+) have a greater influence than monovalent cations (Na+); divalent cations have a greater capacity to neutralize more negative charges, resulting in increases in particle size.
Column transport experiment
Ten groups of experiments were carried out. The experimental conditions and results are listed in Tables 3 and 4.
Effects of pH on the transport of colloidal HA
The effects of pH on the transport of colloidal HA were identified in column transport experiments (tests A1, A2, and A3) and breakthrough curves shown in Fig. 4 at pH values of 5, 7, and 9.As shown in Fig. 4, under different pH conditions, the transport velocity is equal to the velocity of the tracer, and the peak concentration was reached at approximately 1.5 PV from the introduction of particles to reach peak concentration and remain stable. As shown, colloids were retained at a pH of 5, and not all the colloids were transported through the porous medium; however, as the pH increased, there was less deposition and peak concentration increased from 0.98 to 1.00. According to the colloid sedimentary dynamics, the colloid deposition rate coefficient K was 3.94 × 10−6, 1.74 × 10−6, and 4.63 × 10−7, for the pH values of 5, 7, and 9, respectively. The results for the different pH conditions showed that, when the pH increased from 5 to 7, various changes occurred because of the character of the colloids, as follows: the particle size of the colloidal HA and the absolute value of the zeta potential increased, the repulsion between colloids increased, and colloids were stable and facilitated colloid movement. These changes indicated that pH had a minimal influence on colloidal transport. A previous study (Sujoy Roy and Dzombak 1997) reported that transport of latex colloids in Eustis sand increased significantly when the pH increased, and the greater degree of increase in the earlier study relative to this study may have been attributable to the different porous media. The breakthrough curve for pH 9 showed a slightly downward trend after the peak concentration was reached, because of variations in the structural properties at different pH values. When pH was between 5 and 9, the zeta potential changed from −17.8 to −42.4 mV. In acidic conditions, the carboxyl and hydroxyl groups are protonated, and the molecular electrostatic repulsion will decrease, which will cause shrinkage of the spherical particle shape. In alkaline conditions, the negative charge of the HA surface increases, the molecular electrostatic repulsion is higher than that in acidic conditions, and the molecular size of HA increases in chainlike structures. As the HA suspension is injected, the pH of the water in the column is changed to alkaline, and the HA is in chainlike structures, which will influence the transport of HA, resulting in a tendency to decrease slightly after the peak concentration is reached.
To test whether colloids were deposited and released during the transport experiments, scanning electron microscopy (SEM; JSM-6700 F, JEOL, Japan) and energy spectrum analysis (EDX; 333, JEOL, Japan) were used to characterize the microstructure and element composition of the porous medium. The results (pH = 5, IS = 0) are shown in Fig. 5. Before the transport experiments, the original glass beads had smooth surfaces and were composed of SiO2 and some metal oxides (Fig. 5a). Beyond 4PV, when colloidal HA suspension was passed through the glass beads, colloidal particles were adsorbed to the surface of glass beads and the carbon element emerged in the energy spectrum analysis, further illustrating colloid attachment to the surfaces of the glass beads (Fig. 5b). During the flushing process, there was still adsorption of colloidal HA on the surface of the glass beads and very little colloid detachment (Fig. 5c).
Effect of electrolyte valence on the transport of colloid
To determine the effect of solution IS and electrolyte valence on the transport and deposition of colloidal HA, column experiments were conducted. The breakthrough curves of the colloidal HA suspension at a specific pH of 5 at various IS concentrations (0, 0.02, 0.05 M) of two types of electrolytes (NaCl and CaCl2) are shown in Figs. 6 and 7.
It can be seen that IS has a strong effect on the transport and deposition of colloids. The transport velocities of the colloid and the tracer were initially the same, but with increasing IS, the peak effluent concentration decreased and the deposition of colloidal HA increased. When the IS was 0.02 M, it took about 1.5 PV for NaCl to reach the peak C/C 0 of close to 0.95. However, for an IS of 0.05 M, it took around 3 PV to reach the peak C/C 0 of close to 0.92, which is slower than the tracer. The breakthrough curves indicate that the colloid deposition rate coefficient (K) were 3.94 × 10−6, 8.86 × 10−6, and 1.44 × 10−5, as IS increases from 0 to 0.05 M. The colloid deposition rate coefficient (K) increased as the IS increased and more colloids were deposited. The results are similar to those for CaCl2 and agree with those of many other researches on the transport and deposition of colloids (Yan et al. 1995).
Changes in the deposition and detachment of colloidal HA passing through the porous medium with increases in IS are consistent with the predictions of the classical DLVO theory, and support the findings of earlier studies. The deposition process depends on the interactions between the colloid and collector. The surfaces of both colloidal HA and glass beads were negatively charged in the experiments. With the increasing of IS in the aqueous phase, the thicknesses of the electrical double layer decreased, leading to a reduction in electrostatic repulsion between colloidal HA and collectors, and to an increase of colloidal HA deposition. The van der Waals attractive forces are independent of solution chemistry (Sojitra et al. 1995). The breakthrough curves showed tailing when IS was 0.05 M. Comparison showed that the release results at high and low IS values were different because of an increase in the secondary minimum calculated by DLVO theory.
The type of cation also influences the transport of colloidal HA. The divalent cation Ca2+ has the same trend of breakthrough curves as NaCl electrolytes in the colloidal HA suspension, but the increase in the rate of deposition is considerable. The colloid transport rate decreased, and the time taken to reach a plateau increased as the IS increased, which clearly shows that Ca2+ has a greater influence on the transport of HA than NaCl. The value of C/C 0 quickly reached a plateau of 0.92 with 0.05 M of NaCl, whereas it only reached 0.88 with 0.05 M of CaCl2. The C/C 0 values at each plateau decreased as the electrolyte concentration increased because the divalent cation had more influence on the conformation of HA. Divalent cations can neutralize more negative charges on the surface of HA than monovalent cations, thereby resulting in more compact networks of HA, similar to the results of other studies (Jada et al. 2006; Baalousha et al. 2006).
Ca2+ is absorbed to the colloidal particle surface and the organic polymer on the surface of the colloidal HA bridges with divalent cations in the solution, which increases the complexation of functional groups of colloidal HA (Amirbahman and Olson 1995), promoting the union between colloidal particles, and decreases the transport ability of colloidal HA (Kai and Elimelech 2007). When there is Ca2+, the breakthrough curves show significant tailing at colloid release stage, especially for an IS of 0.05 M conditions. In this study, the deionized water (IS = 0) used in the flushing process can be used to study the release of colloidal HA when the hydrochemical properties of the recharge water differ from those of previous processes. In contrast to previous studies, as the ionic strength decreased during the flushing process, the electrostatic interaction force between the colloids and porous medium was rebalanced and deposited colloidal HA was released.
Other studies have reported that as the ionic strength increased, the concentrations of colloidal HA in the effluent decreased (Yamashita et al. 2013). Previous studies (Akbour et al. 2013) did not report desorption of colloidal HA, irreversible attachment of colloidal HA onto porous media can be seen. It should be noted that in earlier studies, the same experimental conditions and colloid-free electrolyte solution were used in the flushing process to examine whether the attachment of colloidal HA onto the porous media was reversible. In this study, when deionized water was used in the flushing process, the deposition was reversible and tailing occurred, as shown in Fig. 7. Changes in hydrochemical conditions have a strong influence on desorption of colloidal HA, and should be considered in the process of managed aquifer recharge. Results from this study agree well with those reported by Shen (2007).
Effect of flow rate
The purpose of these experiments was to study the effect of flow rates on the transport of HA through the column. The breakthrough curves for injecting the HA suspension under different flow rates were measured (Fig. 8) and showed that the flow rate also had a significant effect on the transport and deposition of colloids. With high flow rates, the relative concentrations of the breakthrough curves were higher than for low flow rates. Colloid concentrations increased substantially when the flow rate increased from 0.1 to 0.2 ml/min. The peak C/C 0 increased from 0.85 to 0.98, and the retardation coefficients calculated from the breakthrough curves were 1.20 and 1.06, respectively; however, further increases in the flow rate from 0.2 to 0.4 ml/min caused little increase in the transport of colloids. The peak C/C 0 increased and was close to 1, less was retained in the column, and the retardation coefficient did not change.
These observations can be explained by kinetic effects. At a low flow rate such as 0.1 ml/min, the colloidal deposition process is mainly the result of colloid adsorption reactions to the porous medium. Colloidal HA has more contact time with the porous medium, adsorption of colloidal HA is enhanced, and there is less colloidal HA in the effluent. When the flow rate is increased to 0.2 ml/min, hydrodynamic shear stresses on the solid matrix increase can overcome the electrostatic and van der Waals interactions. With increases in the flow velocity, the equilibrium of the forces between the colloidal particles and porous medium are affected so that there is less contact time with the porous medium, which promotes the mobility of colloidal HA, and less colloidal particle deposition occurs (Torkzaban et al. 2008). When the flow rate is further increased to 0.4 ml/min, however, there is little increase of peak C/C 0, although it may reach a certain critical value of flow rate to facilitate colloidal HA transport in the porous medium (Yin et al. 2010). In addition, when the flow rate is 0.4 ml/min, there is little tailing because when the flow rate increases, the hydrodynamic shear stress increases and adsorbed colloidal HA is detached and is found in the effluent. Results from this study were consistent with the findings reported by Bradford et al. (2002) and Albarran et al. (2011), who found that decreasing flow rates resulted in decreased colloid concentrations effluents.
Conclusions
Four sets of column transport experiments were used in this study to determine the effect of recharge water with a range of chemical properties and different hydrodynamic conditions on the transport and deposition of colloidal particles. The breakthrough curves clearly showed that the transport of colloids can be significantly enhanced when conditions favor less deposition. Colloid transport increased slightly when the pH was increased from 5 to 9, and the peak concentration increased from 0.98 to 1.00. Colloidal HA transport in a porous medium is also controlled by IS; as the IS increased, the thickness of the electrical double layer decreased, leading to a reduction in the electrostatic repulsion between colloidal HA and collectors, and less HA in the effluent. Decreases in the IS during the flushing process caused significant tailing in the release stage. Transport increased significantly when the flow rate increased, as it was influenced by the balance of forces among the colloidal particles, the porous medium and the contact time with the porous medium, as also reported by Sätmark et al. (1996) and Kretzschmar and Sticher (1998). The aim of this study was to obtain greater insight into the transport and deposition behavior of colloidal HA during managed aquifer recharge, and the results provide a basis for further studies on the transport and deposition of colloid-associated subsurface contaminants.
References
Akbour RA, Amal H, Ait-Addi A, Douch J, Jada A, Hamdani M (2013) Transport and retention of humic acid through natural quartz sand: influence of the ionic strength and the nature of divalent cation. Colloids Surf A Physicochem Eng Aspects 436:589–598
Albarran N, Missana T, García-Gutiérrez M, Alonso U, Mingarro M (2011) Strontium migration in a crystalline medium: effects of the presence of bentonite colloids. J Contam Hydrol 122(1–4):76–85
Alvarez-Puebla RA, Garrido JJ (2005) Effect of pH on the aggregation of a gray humic acid in colloidal and solid states. Chemosphere 59(5):659–667
Amirbahman A, Olson TM (1995) Deposition kinetics of humic matter-coated hematite in porous media in the presence of Ca2+. Colloids Surf A Physicochem Eng Aspects 99(1):1–10
Baalousha M, Motelica-Heino M, Coustumer PL (2006) Conformation and size of humic substances: effects of major cation concentration and type, pH, salinity, and residence time. Colloids Surf A Physicochem Eng Aspects 272:48–55
Balnois E, Wilkinson KJ, Lead JR, Buffle J (1999) Atomic force microscopy of humic substances: effects of pH and ionic strength. Environ Sci Technol 33(21):3911–3917
Bradford SA, Yates SR, Bettahar M, Simunek J (2002) Physical factors affecting the transport and fate of colloids in saturated porous media. Water Resour Res 38(12):63-1–63-12
Elimelech M, Nagai M, Chunhan K, Ryan JN (2000) Relative insignificance of mineral grain zeta potential to colloid transport in geochemically heterogeneous porous media. Environ Sci Technol 34(11):2143–2148
Gao B, Cao X, Dong Y, Luo Y, Lena QM (2011) Colloid deposition and release in soils and their association with heavy metals. Critical Rev Environ Sci Technol 41(4):336–372
Hong S, Elimelech M (1997) Chemical and physical aspects of natural organic matter (nom) fouling of nanofiltration membranes. J Membr Sci 132(2):159–181
Huang B, Shu L, Yang YS (2012) Groundwater overexploitation causing land subsidence: hazard risk assessment using field observation and spatial modelling. Water Resour Manag 26(14):4225–4239
Jada A, Akbour RA, Douch J (2006) Surface charge and adsorption from water onto quartz sand of humic acid. Chemosphere 64(8):1287–1295
Jonge LD, Kjaergaard C, Moldrup P (2004) Colloids and colloid-facilitated transport of contaminants in soils: an introduction. Vadose Zone J 3(2):321–325
Kai LC, Elimelech M (2007) Influence of HA on the aggregation kinetics of fullerene (C60) nanoparticles in monovalent and divalent electrolyte solutions. J Colloid Interface Sci 309(1):126–134
Kretzschmar R, Sticher H (1998) Colloid transport in natural porous media: influence of surface chemistry and flow velocity. Phys Chem Earth 23(98):133–139
Kretzschmar R, Barmettler K, Grolimund D, Yan Y, Borkovec M, Sticher H (1997) Experimental determination of colloid deposition rates and collision efficiencies in natural porous media. Water Resour Res 33(5):1129–1137
Kretzschmar R, Borkovec M, Grolimund D, Elimelech M (1999) Mobile subsurface colloids and their role in contaminant transport. Adv Agron 66(08):121–193
Liu D, Johnson PR, Elimelech M (1995) Colloid deposition dynamics in flow-through porous media: role of electrolyte concentration. Environ Sci Technol 29(12):2963–2973
Lvjiajun (2013) Study on soil colloid and phenanthrene transportation through saturated porous media [D] (in Chinese). Liaoning Project Technology University, Jinzhou, China
McCarthy JF, Zachara JM (1989) Subsurface transport of contaminants. Environ Sci Technol 23(5):496–502
McGechan MB, Lewis DR (2002) Sw–soil and water: transport of particulate and colloid-sorbed contaminants through soil, part 1: general principles. Biosyst Eng 83(3):255–273
Parent ME, Velegol D (2004) E. coli adhesion to silica in the presence of HA. Colloids Surf B Biointerfaces 39(1–2):45–51
Sätmark B, Albinsson Y, Liang L (1996) Chemical effects of goethite colloid on the transport of radionuclides through a quartz-packed column. J Contam Hydrol 21(1–4):231–241
Shen C (2007) Kinetics of coupled primary- and secondary-minimum deposition of colloids under unfavorable chemical conditions. Environ Sci Technol 41(20):6976–6982
Sojitra I, Valsaraj KT, Reible DD, Thibodeaux LJ (1995) Transport of hydrophobic organics by colloids through porous media: 1. experimental results. Colloids Surf A Physicochem Eng Aspects 94(2):197–211
Sujoy Roy B, Dzombak DA (1997) Chemical factors influencing colloid-facilitated transport of contaminants in porous media. Environ Sci Technol 31(3):656–664
Thorsten K, Markus F, Mattson ED, Harsh JB (2014) Does water content or flow rate control colloid transport in unsaturated porous media? Environ Sci Technol 48(7):3791–3799
Torkzaban S, Bradford SA, Genuchten MTV, Walker SL (2008) Colloid transport in unsaturated porous media: the role of water content and ionic strength on particle straining. J Contam Hydrol 96(1–4):113–127
Vanderzalm JL, Page DW, Barry KE, Dillon PJ (2010) A comparison of the geochemical response to different managed aquifer recharge operations for injection of urban stormwater in a carbonate aquifer. Appl Geochem 25(9):1350–1360
Yamashita Y, Tanaka T, Adachi Y (2013) Transport behavior and deposition kinetics of humic acid under acidic conditions in porous media. Colloids Surf A Physicochem Eng Aspects 417(3):230–235
Yan YD, Borkovec M, Sticher H (1995) Deposition and release of colloidal particles in porous media. Progress Colloid Polym Sci 98:132–135
Yin XQ, Sun HM, Lei YI, Yi-Qing LU, Wang GD, Zhang XC (2010) Effect of flow rate of pore water on the transport of colloid in saturated porous media. J Soil Water Conserv 24(5):101–104
Zhang W, Ying H, Yu X, Dan L, Zhou J (2015) Multi-component transport and transformation in deep confined aquifer during groundwater artificial recharge. J Environ Manag 152:109–119
Zhu Y, Ma LQ, Dong X, Harris WG, Bonzongo JC, Han F (2014) Ionic strength reduction and flow interruption enhanced colloid-facilitated Hg transport in contaminated soils. J Hazard Mater 264(2):286–292
Acknowledgements
The researchers gratefully acknowledge the funding provided by the National Natural Science Foundation of China (41472215). The authors would like to thank the journal editors and the reviewers for valuable comments that have improved the paper considerably.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Liu, D., Zhou, J., Zhang, W. et al. Column experiments to investigate transport of colloidal humic acid through porous media during managed aquifer recharge. Hydrogeol J 25, 79–89 (2017). https://doi.org/10.1007/s10040-016-1465-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10040-016-1465-0