Dear Editor,

We read with interest the recently published meta-analysis comparing total extraperitoneal endoscopic hernioplasty (TEP) with Lichtenstein repair for inguinal hernia [1]. The conclusion that TEP results in more recurrences than Lichtenstein is, however, problematic.

The problem is, that the authors included the study by Neumayer et al. [2]. This study had a weight of 59.2% in the meta-analysis, but should not be included at all. The reason for this is that the mesh sizes for the TEP repairs were way too small, which in itself have resulted in more recurrences in the TEP group. The mean mesh sizes for the TEP repairs were only around 8 cm in vertical dimension [3], meaning that many must have been even smaller than 8 cm, and this is smaller than the mesh sizes recommended in the current World Guidelines for inguinal hernia repair [4]. It has been shown, that mesh size should be at least 10 × 15 cm, otherwise recurrence rates will increase [4].

The authors stated in the meta-analysis [1] that they performed a sensitivity analysis and that these analyses did not reveal any discrepancies. We would like to see the results of these analyses and have therefore conducted them ourselves, based on the data presented in the review [1]. A sensitivity analysis without the study by Neumayer et al. shows no difference in recurrence rates between TEP and Lichtenstein (Fig. 1). Furthermore, when performing the analysis with a random effects model (which would be appropriate given the differences in study design), there is also no difference in recurrence rates (Fig. 2).

Fig. 1
figure 1

Meta-analysis without including Neumayer et al. [2]

Fig. 2
figure 2

Meta-analysis including all studies, but with a random effects model

When performing a meta-analysis, it is important to consider the data entered and quality of the studies. Heterogeneity is an important assumption when conducting a meta-analysis. First, is there clinical and methodological homogeneity between the studies and secondly is there statistical homogeneity? Statistical heterogeneity is measured by the I2 value in the analysis. Cochrane Handbook provides intervals for I2 values; “50–90%: may represent substantial heterogeneity”. In the meta-analysis regarding recurrence, the I2 value is 63%, and this should prompt authors to investigate reasons for heterogeneity [5]. Furthermore, we will encourage all authors to use the newly updated Cochrane Handbook [5].

We find the presented analysis to be misleading and believe that the conclusion based on the available data should be that there is no difference in the recurrence rates between TEP and Lichtenstein repair.