Abstract
Background
Extraarticular fractures of distal humerus are challenging injuries to treat because of complex anatomy and fracture patterns. Functional bracing may not provide adequate stability in these injuries and operative treatment with intramedullary nails or conventional plates also has the limitation of inadequate fixation in the short distal fragment. The 3.5 mm precontoured single column locking plate (extraarticular distal humerus plate [EADHP]) has been introduced to overcome this problem. We evaluated the clinical and functional outcomes of treating these fractures with the EADHP.
Materials and Methods
26 patients with extraarticular fractures of distal humerus presenting within 3 weeks of injury between January 2012 and June 2015, were included in this prospective study. Open IIIB and IIIC fractures, nonunions, or those with a history of previous infection in the arm were excluded. Operative fixation was done using the EADHP in all the cases. The time for union, range of motion at shoulder and elbow and secondary procedures were recorded in followup. The shoulder and elbow function was assessed using the University of California Los Angeles (UCLA) shoulder scale and Mayo Elbow Performance Score (MEPS) respectively.
Results
There were 21 males and 5 females with mean age of 37.3 years (range 18–72 years). Twenty two (84.6%) cases had complex fracture patterns (AO/OTA Type 12-B and C). The mean time to fracture union was 22.4 weeks (range 16–28 weeks). The mean followup time was 11.6 months, (range 4–24 months). Four patients (15.4%) had failure of cortical screws in the proximal fracture fragment, of which two required revision fixation with bone grafting. Another nonunion was seen following a surgical site infection, which healed after wound lavage and bone grafting. The MEPS (average: 96.1; range 80–100) was excellent in 81% cases (n = 21) and good in 19% cases (n = 5). UCLA score (average: 33.5; range 25–35) was good/excellent in 88.5% cases (n = 23) and fair in 11.5% cases (n = 3).
Conclusion
EADHP is a reliable option in treating extraarticular distal humeral fractures as it provides stable fixation with an early return to function.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Ali E, Griffiths D, Obi N, Tytherleigh-Strong G, Van Rensburg L. Nonoperative treatment of humeral shaft fractures revisited. J Shoulder Elbow Surg 2015;24:210–4.
Jawa A, McCarty P, Doornberg J, Harris M, Ring D. Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 2006;88:2343–7.
Korner J, Lill H, Müller LP, Hessmann M, Kopf K, Goldhahn J, et al. Distal humerus fractures in elderly patients: Results after open reduction and internal fixation. Osteoporos Int 2005;16 Suppl 2:S73–9.
Scolaro JA, Voleti P, Makani A, Namdari S, Mirza A, Mehta S. Surgical fixation of extra-articular distal humerus fractures with a posterolateral plate through a triceps-reflecting technique. J Shoulder Elbow Surg 2014;23:251–7.
Capo JT, Debkowska MP, Liporace F, Beutel BG, Melamed E. Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate. Int Orthop 2014;38:1037–43.
Fawi H, Lewis J, Rao P, Parfitt D, Mohanty K, Ghandour A. Distal third humeri fractures treated using the Synthes™ 3.5-mm extra-articular distal humeral locking compression plate: Clinical, radiographic and patient outcome scores. Shoulder Elbow 2015;7:104–9.
Yang Q, Wang F, Wang Q, Gao W, Huang J, Wu X, et al. Surgical treatment of adult extra-articular distal humeral diaphyseal fractures using an oblique metaphyseal locking compression plate via a posterior approach. Med Princ Pract 2012;21:40–5.
Spitzer AB, Davidovitch RI, Egol KA. Use of a “hybrid” locking plate for complex metaphyseal fractures and nonunions about the humerus. Injury 2009;40:240–4.
Saragaglia D, Rouchy RC, Mercier N. Fractures of the distal humerus operated on using the Lambda® plate: Report of 75 cases at 9.5 years followup. Orthop Traumatol Surg Res 2013;99:707–12.
Levy JC, Kalandiak SP, Hutson JJ, Zych G. An alternative method of osteosynthesis for distal humeral shaft fractures. J Orthop Trauma 2005;19:43–7.
Scolaro JA, Matzon JL, Mehta S. Tips and techniques-surgical fixation of extra-articular distal humerus fractures with a posterolateral locking compression plate. Univ PA Orthop J 2009;19:103–8.
Scolaro JA, Hsu JE, Svach DJ, Mehta S. Plate selection for fixation of extra-articular distal humerus fractures: A biomechanical comparison of three different implants. Injury 2014;45:2040–4.
Amstutz HC, Sew Hoy AL, Clarke IC. UCLA anatomic total shoulder arthroplasty. Clin Orthop Relat Res 1981;155 7–20.
Morrey BF, An KN, Chao EY. Functional evaluation of the elbow. In: Morrey BF, editor. The Elbow and Its Disorders. 2nd ed. Philadelphia: W. B. Saunders; 1993. p. 86–97.
Ellman H, Hanker G, Bayer M. Repair of the rotator cuff. End-result study of factors influencing reconstruction. J Bone Joint Surg Am 1986;68:1136–44.
Shetty MS, Kumar MA, Sujay K, Kini AR, Kanthi KG. Minimally invasive plate osteosynthesis for humerus diaphyseal fractures. Indian J Orthop 2011;45:520–6.
Gosler MW, Testroote M, Morrenhof JW, Janzing HM. Surgical versus non-surgical interventions for treating humeral shaft fractures in adults. Cochrane Database Syst Rev 2012;1:CD008832.
Fjalestad T, Strømsøe K, Salvesen P, Rostad B. Functional results of braced humeral diaphyseal fractures: Why do 38% lose external rotation of the shoulder? Arch Orthop Trauma Surg 2000;120:281–5.
Papasoulis E, Drosos GI, Ververidis AN, Verettas DA. Functional bracing of humeral shaft fractures. A review of clinical studies. Injury 2010;41:e21–7.
Pehlivan O. Functional treatment of the distal third humeral shaft fractures. Arch Orthop Trauma Surg 2002;122:390–5.
Moran MC. Modified lateral approach to the distal humerus for internal fixation. Clin Orthop Relat Res 1997;340:190–7.
Sharaby M, Elhawary A. A simple technique for double plating of extraarticular distal humeral shaft fractures. Acta Orthop Belg 2012;78:708–13.
Prasarn ML, Ahn J, Paul O, Morris EM, Kalandiak SP, Helfet DL, et al. Dual plating for fractures of the distal third of the humeral shaft. J Orthop Trauma 2011;25:57–63.
Aggarwal S, Kumar V, Bhagwat KR, Behera P. AO extra-articular distal humerus locking plate: Extended spectrum of usage in intraarticular distal fractures with metaphyseal extension – Our experience with 20 cases. Eur J Orthop Surg Traumatol 2014;24:505–11.
Gosler MW, Testroote M, Morrenhof JW, Janzing HM. Surgical versus non-surgical interventions for treating humeral shaft fractures in adults. Cochrane Database Syst Rev. 2012;18;1:CD008832. doi: 10.1002/14651858.CD008832.pub2.
Author information
Authors and Affiliations
Corresponding author
Additional information
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Rights and permissions
About this article
Cite this article
Jain, D., Goyal, G.S., Garg, R. et al. Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures. IJOO 51, 86–92 (2017). https://doi.org/10.4103/0019-5413.197554
Published:
Issue Date:
DOI: https://doi.org/10.4103/0019-5413.197554