Abstract
Background
Fluctuations in pH of saliva during a prolonged treatment course influences the enamel demineralization progress, which is one of the complications of fixed orthodontic treatment. This randomized clinical trial aimed to evaluate and compare the short-term effects of stainless steel (SS) versus elastomeric (EM) ligatures on salivary pH in patients scheduled for fixed orthodontic treatment.
Methods
Seventy participants were enrolled in the study (54 female, 16 male) aged 19–36 years who met specific inclusion criteria. They were randomly selected and allocated into two equal groups through computer-generated randomization. All patients received fixed orthodontic treatment using conventional orthodontic brackets. Two commonly used archwire ligature methods were used: SS and EMs. An unstimulated (resting) salivary sample was collected before tying of the ligatures at T0 (baseline), 2 weeks, 6 (weeks), and 12 (weeks). Salivary pH was measured using a digital pH meter. The level of significance was set at p value < 0.05.
Results
The salivary pH level was stable between T0 and T1 (6.72 ± 0.14), then significantly and progressively increased from T1 to T2 (6.78 ± 0.13) and from T2 to T3 (6.81 ± 0.14) with (p < 0.05) in the SS group. In the EM group, the salivary pH level was significantly decreased in all follow-up periods; T0 (6.77 ± 0.16), T1 (6.72 ± 0.14), T2 (6.67 ± 0.13) and T3 (6.64 ± 0.13).
Conclusion
The EM ligatures showed a significant decrease in salivary pH to an unfavorable level, which increased the risk of enamel demineralization. Therefore, EMs as ligature material is preferably should not be recommended in patients with high caries index or inadequate oral hygiene.
Trial registration ANZCTR.org. (ACTRN12618001647224) http://www.anzctr.org.au/ACTRN12618001647224.aspx. Registration Date: 5/10/2018, “Retrospectively registered”.
Similar content being viewed by others
Background
Malocclusion is considered as the third most common oral problem following dental caries and periodontal diseases [1, 2]. Most malocclusions are treated by fixed orthodontic appliances as a second phase following orthopedic treatment, as a comprehensive treatment after cessation of growth, or as a preparatory stage for orthognathic surgery [3]. Treatment of malocclusion with fixed orthodontic appliances is estimated to last from 18 to 36 months [4, 5]. As they are termed “fixed appliances,” they are fitted permanently to the teeth, creating plaque-retentive areas around the bracket wings. This increases chances for plaque accumulation and bacterial colonization. The main formed colonies of specific interest are the acid-producing bacteria Streptococcus mutans and Lactobacilli [6,7,8,9,10,11].
Plaque harboring around the brackets is also influenced by the archwire ligation material [7, 10, 12,13,14]. Stainless steel (SS) and elastomeric modules (EM) are the most commonly used materials to secure archwire to the bracket slots [14]. They have different properties, including their surface topography.
SS ligatures demonstrated less plaque retention compared to EM and are, therefore, better for oral hygiene maintenance [14]. Higher levels of acidogenic bacteria are detected with EM ligatures, most noticeably S.mutans and Lactobacilli [10, 15]. This contributes to the drop in salivary pH levels during orthodontic treatment [16, 17]. The choice to use either ligation method has been shown to be a matter of personal preference of the practitioner and is influenced by the patient choice.
Salivary pH is one indicator of caries susceptibility of the individual patient. The risk of enamel demineralization is increased if salivary pH drops below the critical value (pH = 5.5) [18,19,20]. This drop contributes to the formation of white spot lesions reported to occur in around 50% of the orthodontic patients [21,22,23,24].
The effect of fixed orthodontic appliances on salivary pH has been investigated in previous studies without reporting which type of archwire ligation material was used. In an observational study, Zogakis et al. [25] demonstrated a significant decrease in pH of saliva six weeks after fitting the appliance. Different results were presented by Peros et al. [26] who reported an increase in salivary pH at 6, 12 and 18 weeks after fixed orthodontic therapy. Bonetti et al. [16] reported that no changes in salivary pH values occurred under the effect of fixed orthodontic treatment. To the best of our knowledge and according to the available literature, no randomized clinical trial (RCT) has evaluated the effect of SS and EM ligation materials on pH of saliva [27].
Specific objectives
The aim of this trial was to evaluate and compare the short-term effects of SS and EM ligatures on salivary pH in patients treated with fixed orthodontic appliances.
Methods
Trial design
This investigation was a two-arm parallel-group randomized controlled clinical trial. No changes were introduced to the trial following commencement.
Participants, eligibility criteria, and settings
The selection criteria included subjects requesting orthodontic treatment, aged between 19-36 years, had good oral hygiene, and were periodontally healthy (plaque index ≤ 1). Patients with habits (mouth breathing, smoking, or any chewing habits), chronic or systemic diseases or chronic medication intake were excluded. The deterioration of oral hygiene level after recruitment was considered an exclusion criterion.
Patients were recruited from the Department of Biological and Preventive Sciences, College of Dentistry, University of Science and Technology, Sana’a, Republic of Yemen. Consecutive patients were examined by the primary researcher. Those meeting the selection criteria were invited to participate. Informed consent was signed after the nature of the study was explained.
Intervention
This study follows the guidelines of the Consolidated Standards of Reporting Trials statement [28]. Ethical approval was obtained from the ethics committee of the University of Science and Technology (Registry No: EAC/UST126). All participants received a standard protocol of oral hygiene instructions and motivation (according to Bass technique) using tooth paste containing fluoride.
All subjects were treated with straight wire appliances using MBT bracket system (SIA, Italy). Alignment and leveling were initiated with round nickel-titanium archwires and treatment proceeded as required for each patient.
The sample consisted of two groups, each included 35 subjects. They received archwire ligation (SIA, Italy) with either SS (Group A) or EM (Group B) based on the randomization technique followed. The ligations were replaced every four weeks during follow-up visits.
Saliva collection
Unstimulated (resting) whole salivary samples were collected according to the protocol derived from the World Health Organization/International Agency of Research [29] as follow.
The samples were obtained in the morning between 9 A.M. and 12 P.M. using the passive drooling method. The subject was seated in the dental chair and instructed to allow saliva to pool in the mouth passively for five minutes, then drool it into a graduated plastic sterile tube. These samples were instantly transferred into a reservoir container and immediately sent to the laboratory for salivary pH measurement. The laboratory technician received the salivary samples that were coded and labeled without any indications of intervention details.
Outcomes
The outcome of this study was to measure the pH of the salivary samples collected from the patients at four time points. The baseline value was measured before the placement of ligature materials (T0). T1, T2 and T3 were measured at 2, 6 and 12 weeks from T0. The purpose was to evaluate and compare the change in salivary pH values with the introduction of two different types of ligatures in two randomly assigned groups.
Measurements were performed in the Laboratory of Drugs and Medicine, College of Pharmacy, University of Science and Technology, Sana’a, Republic of Yemen. A digital handheld pH meter with incorporated automatic temperature compensation (3510, JENWAY, UK) was used. The procedure was conducted according to the manufacturer’s instructions and included the following steps: (a) Calibration was performed by freshly prepared standard buffer solutions at pH = 7 and 10. (b) For pH measurement, the probe sensor was fully immersed inside the sample for 30s to get a stable final reading. (c) Disinfection was achieved by washing the meter under running water to remove any remnants. It was then cleaned with alcohol and allowed to dry [30].
Sample size calculation
The required sample size was calculated using the G*power software. Based on previous studies with a mean difference of 0.1 unit change in pH and a ± 0.14 standard deviation (SD) with a power of 80% and α = 0.05, a minimum number of 35 participants was required for each group [16, 31].
Randomization (random number generation, allocation concealment, implementation)
A total of 70 participants (54 female and 16 male) ranging in age from 19 to 36 years were randomly selected with a 1:1 allocation ratio. Randomization was accomplished with random permuted blocks of 70 participants with the allocations concealed in sequentially numbered, opaque, sealed envelopes. The clinic assistant was responsible for generating the allocation sequences, preparing the enclosed envelopes in sequence numbers, enrolling the participants, and assigning them into their groups.
Blinding
Blinding of the patients and investigator to the intervention was not implemented. Instead, this applied to the laboratory technician and the statistician.
Statistical analysis
The data were statistically analyzed using statistical software (SPSS version 25; Armonk, NY: IBM Corp). Data included age, gender, type of archwire ligature (SS or EM), and salivary pH at T0, T1, T2 and T3. The Shapiro–Wilk test was applied to verify the normality of distribution of the examined variable. The t-test for independent samples was applied for the comparison between groups of archwire ligation. Intra-group difference comparisons between T0 and T1, T2 and T3 were carried out with the t-test for paired samples. Repeated measures ANOVA was used to make comparisons between T0, T1, T2 and T3, and the level of significance was set at p < 0.05.
Results
Baseline data
Recruitment began in January, 2018 and ended in March, 2019. Baseline demographic and clinical characteristics for each group are shown in (Table 1.) The data relative to salivary pH were normally distributed.
Participant flow
The flow of participants throughout the trial is demonstrated in the flowchart (Fig. 1). Eight participants did not receive the allocated intervention for various reasons, including a lack of follow-up and discontinuation of treatment.
Outcomes and estimation
Significant changes in salivary pH values were observed (p < 0.05) for both ligation materials compared to the baseline values (T0). The EM group showed a significant decrease of salivary pH value in all assessment time points. Regarding the SS group, a significant increase of salivary pH value was observed at 6 (T2) and 12 (T3) weeks (Table 2). Repeated ANOVA measured for multiple comparisons revealed a significant difference in salivary pH value between T0, T2 and T3 (Table 3).
Harm
No serious harm was inflicted upon the participants other than moderate marginal gingivitis associated with fixed orthodontic treatment.
Discussion
Limitations
Blinding of the investigator and participants was not feasible. Short-term follow-up for 3 months during alignment and leveling stage was conducted, since only brackets, archwires and ligatures used excluding other method, such as, elastics, power chain and coils, among others. Bacterial colonization was not measured and it is recommended to be done in any future studies to support the significant drop in salivary pH level. Type of drinks, food, oral hygiene and other confounders are to be considered in future studies with larger sample size.
Generalizability
The above findings may be applicable to other populations. The average salivary pH values ranged from 6.5 to 7.5, with no difference between communities and populations [30, 32].
Interpretation
The importance of preservation of enamel integrity during orthodontic treatment urges orthodontists and researchers to improve the appliances used to decrease the chances for plaque accumulation and subsequent enamel demineralization.
In their systematic review, Freitas et al. [33] reported that fixed orthodontic appliances affect the quality and quantity of oral microbiota with a significant increase of acid producing bacteria, particularly S. mutans and Lactobacilli, which contributes to the drop in salivary pH level during the course of treatment.
No previous study has evaluated the effect of archwire ligation materials on salivary pH. Comparison of the current study’s findings with those of previous studies was not possible. Several previous studies evaluated the effect of fixed orthodontic appliance on salivary pH. They compared the changes before and after treatment without specifying which type of ligature materials were used [12, 16, 17, 25, 31, 33,34,35,36,37,38,39,40].
The effect of archwire ligation materials (SS and EM) have been previously evaluated on oral biomarkers other than salivary pH, including plaque, gingival, bleeding indices, and microbial colonization with a split mouth design [10, 13,14,15]. Even in the last three years several studies were conducted and none of them specify the type of ligature used. Alshahrani et al. [41] reported significant reductions in the salivary flow rate and pH two months after commencing fixed orthodontic treatment and AlHudaithi and Alshammery [42] found significant reduction in salivary pH after four to five weeks of de-bonding or at the retention period. At the same time, Anu et al. [43], Dallel et al. [44], and Kouvelis et al. [45] concluded that salivary pH did not significantly change between the studied time points during fixed orthodontic treatment.
The EM group demonstrated a significant decrease in salivary pH level in all stages. By comparison, the SS group showed an increase after T1. The current study findings agree with the results of Forsberg et al. [14] that demonstrated a higher level of S. mutans and Lactobacillus on EM ligature compared to SS for 12 orthodontic patients. They recommended that EM should be avoided for patients with inadequate oral hygiene.
Türkkahraman et al. [10] evaluated the microbial colonization between two archwire ligatures with split-mouth study at the early stages of orthodontic treatment for 21 orthodontic patients at three different times. They reported that EM ligature had slightly more microbial colonization of S. mutans and Lactobacilli compared to SS. However, the difference was not significant.
Alves de Souza et al. [13] conducted a study to evaluate microbial colonization using polymerase chain reaction analysis of two archwire ligations, EM and SS before fixed orthodontic appliance and after 6 months for 14 patients with split mouth design. They reported that EM ligatures were associated with higher scores of microbial plaque index than SS ligatures.
In comparison, Sukontapatipark et al. [8] conducted an experimental study by scanning electron microscopy, evaluated microbial colonization on two types of archwire ligation, EM and SS, for 20 patients at three time intervals over a period of three weeks. They demonstrated that the ligation material did not influence the microbial morphotypes.
EMs are considered an organic material in their composition which would be more favorite for bacterial colonization than SS, which is an inorganic material with an inert metal surface [46, 47]. The differences in surface tomography and structural characteristics of elastomeric and steel ligature wires may also be a factor that enhances the bacterial colonization on the organic and porous surfaces of EM. These are diminished with SS, which has inorganic and plant surfaces [48, 49]. The discrepancies may be attributed to the difference in study design and duration, sample size, methods of saliva collection, and tools for measuring salivary pH.
Females’ participants most often apply for orthodontic than males [50], more often maintain attendance, and commitment to orthodontic clinics and treatment instructions. Unstimulated (resting) saliva was specified for collection. This is an oral secretion in contact with teeth and is a long-lasting rather than stimulated saliva.
The clinical significant of study results demonstrated via a short-term evaluation that EM is a cause of a drop in salivary pH, which constitutes a risk indicator for enamel demineralization and the formation of white spot lesions throughout treatment with fixed orthodontic appliances.
Preventive approaches relating to changes in the oral environment in orthodontic patients were established. Checking the pH of saliva can be valuable as part of an overall clinical assessment especially for patients with high caries index.
Conclusion
Early in orthodontic treatment, EM had a significant effect on salivary pH compared with SS ligature, lowering it to unfavorable levels. Therefore, the EM as ligature material should preferably not to be recommended in orthodontic patients with high caries index or inadequate oral hygiene.
Availability of data and materials
Any of the supporting data in this manuscript are available in any time.
Abbreviations
- EM:
-
Elastomeric Modules
- SS:
-
Stainless Steel
- RCT:
-
Randomized Clinical Trial
References
Guo L, Feng Y, Guo H-G, Liu B-W, Zhang Y. Consequences of orthodontic treatment in malocclusion patients: clinical and microbial effects in adults and children. BMC Oral Health. 2016;16:1–7.
Alhammadi MS, Halboub E, Fayed MS, Labib A, El-Saaidi C. Global distribution of malocclusion traits: a systematic review. Dental Press J Orthodont. 2018;23:40e41–40.e10.
Ngan P, Moon W. Evolution of class III treatment in orthodontics. Am J Orthod Dentofac Orthop. 2015;148:22–36.
Tsichlaki A, Chin SY, Pandis N, Fleming PS. How long does treatment with fixed orthodontic appliances last? A systematic review. Am J Orthod Dentofac Orthop. 2016;149:308–18.
Moresca R. Orthodontic treatment time: can it be shortened? Dent Press J Orthod. 2018;23:90–105.
Fadia D, Vandekar M, Vaid N, Doshi V. Plaque accumulation and Streptococcus mutans levels around self-ligating bracket clips and elastomeric modules: a randomized controlled trial. APOS Trends Orthod. 2015;5:97–102.
Baka ZM, Basciftci FA, Arslan U. Effects of 2 bracket and ligation types on plaque retention: a quantitative microbiologic analysis with real-time polymerase chain reaction. Am J Orthod Dentofac Orthop. 2013;144:260–7.
Sukontapatipark W, El-Agroudi MA, Selliseth NJ, Thunold K, Selvig KA. Bacterial colonization associated with fixed orthodontic appliances. A scanning electron microscopy study. Eur J Orthod. 2001;23:475–84.
Jordan C, LeBlanc D. Influences of orthodontic appliances on oral populations of mutans streptococci. Mol Oral Microbiol. 2002;17:65–71.
Türkkahraman H, et al. Archwire ligation techniques, microbial colonization, and periodontal status in orthodontically treated patients. Angle Orthod. 2005;75:231–6.
Topaloglu-Ak A, Ertugrul F, Eden E, Ates M, Bulut H. Effect of orthodontic appliances on oral microbiota—6 month follow-up. J Clin Pediatr Dent. 2011;35:433–6.
Chang H, Walsh LJ, Freer TJ. The effect of orthodontic treatment on salivary flow, pH, buffer capacity, and levels of mutans streptococci and lacto bacilli. Aust Orthod J. 1999;15:229.
de Souza RA, et al. Periodontal and microbiologic evaluation of 2 methods of archwire ligation: ligature wires and elastomeric rings. Am J Orthod Dentofac Orthop. 2008;134:506–12.
Forsberg, et al. Ligature wires and elastomeric rings: two methods of ligation, and their association with microbial colonization of Streptococcus mutans and iactobacilli. Eur J Orthod. 1991;13:416–20.
Sawhney R, Sharma R, Sharma K. Microbial colonization on elastomeric ligatures during orthodontic therapeutics: an overview. 2018.
Bonetti GA, Parenti SI, Garulli G, Gatto MR, Checchi L. Effect of fixed orthodontic appliances on salivary properties. Prog Orthod. 2013;14:13.
Arab S, et al. Effect of fixed orthodontic treatment on salivary flow, pH and microbial count. J Dent. 2016;13:18.
Cardoso AA, et al. Influence of salivary parameters in the caries development in orthodontic patients—an observational clinical study. Int J Pediatr Dent. 2017;27:540–50.
Lenander-Lumikari M, Loimaranta V. Saliva and dental caries. Adv Dent Res. 2000;14:40–7.
Makrygiannakis MA, Kaklamanos EG, Milosevic A, Athanasiou AE. Tooth wear during orthodontic treatment with fixed appliances: a systematic review. J Orthod. 2018;66:1–9.
O’reilly M, Featherstone J. Demineralization and remineralization around orthodontic appliances: an in vivo study. Am J Orthod Dentofac Orthop. 1987;92:33–40.
Mizrahi E. Enamel demineralization following orthodontic treatment. Am J Orthod. 1982;82:62–7.
Chang H, Walsh L, Freer T. Enamel demineralization during orthodontic treatment. Aetiology and prevention. Aust Dent J. 1997;42:322–7.
Akin, et al. Incidence of white spot lesion during fixed orthodontic treatment. Turkish J Orthod. 2013;26:66.
Zogakis IP, Koren E, Gorelik S, Ginsburg I, Shalish M. Effect of fixed orthodontic appliances on nonmicrobial salivary parameters. Angle Orthod. 2018;88:806–11.
Peros K, Mestrovic S, Anic-Milosevic S, Slaj M. Salivary microbial and nonmicrobial parameters in children with fixed orthodontic appliances. Angle Orthod. 2011;81:901–6.
Lucchese A, Bondemark L, Marcolina M, Manuelli M. Changes in oral microbiota due to orthodontic appliances: a systematic review. J Oral Microbiol. 2018;10:1476645.
Pandis N, Fleming PS, Hopewell S, Altman DG. The CONSORT Statement: Application within and adaptations for orthodontic trials. Am J Orthod Dentofac Orthop. 2015;147:663–79.
Lombardo L, et al. Changes in the oral environment after placement of lingual and labial orthodontic appliances. Prog Orthod. 2013;14:28.
Baliga S, Muglikar S, Kale R. Salivary pH: a diagnostic biomarker. J Indian Soc Periodontol. 2013;17:461.
Scheie AA, Arneberg P, Krogstad O. Effect of orthodontic treatment on prevalence of Streptococcus mutans in plaque and saliva. Eur J Oral Sci. 1984;92:211–7.
Galvão-Moreira LV, et al. Sex differences in salivary parameters of caries susceptibility in healthy individuals. Oral Health Prev Dent. 2017;16:71–7.
Freitas, et al. The influence of orthodontic fixed appliances on the oral microbiota: a systematic review. Dent Press J Orthod. 2014;19:46–55.
Ristic M, Svabic MV, Sasic M, Zelic O. Effects of fixed orthodontic appliances on subgingival microflora. Int J Dental Hygiene. 2008;6:129–36.
Ristic M, Svabic MV, Sasic M, Zelic O. Clinical and microbiological effects of fixed orthodontic appliances on periodontal tissues in adolescents. Orthod Craniofac Res. 2007;10:187–95.
Panchmal GS, Shenoy R, Jodalli P, Sonde L, Kundapur N. Changes in the oral environment after placement of fixed orthodontic appliance for the treatment of malocclusion-a descriptive longitudinal study. Oral Health Prev Dent. 2017;15:66.
Maret D, et al. Effect of fixed orthodontic appliances on salivary microbial parameters at 6 months: a controlled observational study. J Appl Oral Sci. 2014;22:38–43.
Li Y, et al. The effects of fixed orthodontic appliances on saliva flow rate and saliva electrolyte concentrations. J Oral Rehabil. 2009;36:781–5.
Kanaya T, et al. International congress series; Elsevier. pp. 189–90.
Jordan C, LeBlanc DJ. Influences of orthodontic appliances on oral populations of mutans streptococci. Oral Microbiol Immunol. 2002;17:65–71.
Alshahrani I, et al. Changes in essential salivary parameters in patients undergoing fixed orthodontic treatment: a longitudinal study. Niger J Clin Pract. 2019;22:707.
AlHudaithi FS, Alshammery DA. Screening of biochemical parameters in the orthodontic treatment with the fixed appliances: a follow-up study. Saudi J Biol Sci. 2021;6:66.
Anu V, Kumar PM, Shivakumar M. Salivary flow rate, pH and buffering capacity in patients undergoing fixed orthodontic treatment—a prospective study. Indian J Dent Res. 2019;30:527.
Dallel I, et al. Influence of orthodontic appliance type on salivary parameters during treatment. Angle Orthod. 2020;90:532.
Kouvelis G, et al. A prospective cohort study assessing the impact of fixed orthodontic appliances on saliva properties and oral microbial flora. Oral Health Prev Dent. 2021;19:67–76.
Mei A, Li S. Bacterial adhesion forces and biofilm prevention on orthodontic materials. University Library Groningen[Host]; 2011.
Sawhney R, Sharma R. Microbial colonization on elastomeric ligatures during orthodontic therapeutics: an overview. Turk J Orthod. 2018;31:21–5. https://doi.org/10.5152/TurkJOrthod.2018.17050.
Pandurangan H, Kavitha TS, Gnanamani VA. microbial adhesion on orthodontic ligating materials: an in vitro assessment. Adv Microbiol. 2013;3:108–14.
Paehl RM, Thalheim BA. Google Patents. 2017.
Lagorsse A, Gebeile-Chauty S. Does gender make a difference in orthodontics? A literature review. L’ Orthodontie francaise. 2018;89:157–68. https://doi.org/10.1051/orthodfr/2018011.
Acknowledgements
Not applicable.
Funding
Not applicable.
Author information
Authors and Affiliations
Contributions
HAANA—Primary investigator, corresponding author; RAAI—Co-supervisor; MSAA—Main-supervisor; Both co- and main supervisors approved every step in the study in details and supervised all the steps of work and revised the primary and final version for manuscript writing. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Ethical approval was obtained from the ethics committee of the University of Science and Technology, Sana’a, Republic of Yemen (Registry No: EAC/UST126). A form of the approval was submitted as a separate document. Every participant has signed an Informed consent after the nature of the study was explained. A form of the informed consent was submitted as a separate document.
Consent for publication
We hereby submitting the manuscript for publication in “BMC oral health Journal” titled “Salivary pH changes under the effect of stainless steel versus elastomeric ligatures in fixed orthodontic patients: A single-center, randomized controlled clinical trial” We assure that this manuscript is an original work has neither been published in any other journal nor submitted for publication in any other journal. A form of the Authors approval and signatures was submitted as a sperate document.
Competing interests
The authors declare that they have no competing of interest regarding this work.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Al-Haifi, H.A.A., Ishaq, R.A.A. & Al-Hammadi, M.S.A. Salivary pH changes under the effect of stainless steel versus elastomeric ligatures in fixed orthodontic patients: a single-center, randomized controlled clinical trial. BMC Oral Health 21, 544 (2021). https://doi.org/10.1186/s12903-021-01906-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12903-021-01906-4