Introduction

Molecular imaging of cells is an important tool for the investigation of biological systems. The ability to trace and track different cells or different components within a cell has an important role in understanding cellular trafficking pathways, identifying receptor expression and facilitating the understanding of cellular signaling pathways which can lead to the design of effective therapies for medical applications1,2,3,4,5,6,7. Therefore, a method for identifying the binding of labeling markers to a cell and the ability to trace it is of great importance. One common method for labeling is to use fluorescent dyes and fluorescent proteins (FPs) as biomarkers8,9,10,11. However, these markers are photo toxic to living cells and their photochemical activity is destroyed after multiple cycles of switching on and off and in addition, their use is limited to visible wavelengths12,13,14,15,16. GNPs provide an alternative choice for labeling as they are nontoxic, have a long lasting activity, are inexpensive and easy to produce and have spectral absorption/reflectance peak suitable for a variety of wavelengths17,18,19.

GNPs exhibit localized surface plasmon resonance (SPR), which is manifested by enhanced absorption and scattering at a specific optical frequency when are under optical illumination that matches this resonant wavelength20. The peak resonance wavelength of the GNPs is governed by their shape, size and the refractive index of the environment21,22,23,24. The most basic GNP shapes include spheres, which have a peak resonance around 532nm (depending on their exact dimensions) and rods which usually have two resonance peaks; one due to the transverse oscillation of the electrons (which may be around 520nm) and the other due to the longitudinal plasmon resonance at longer wavelengths that depends on the aspect ratio of the nanorod. The larger the aspect ratio is, the wavelength of the second resonance will become longer. Recently, the use of gold nanoparticles (GNPs) as biomarkers has been demonstrated25,26,27,28, however, the ability to simultaneously trace different types of GNPs that are site-specifically labeling tissues, cells or areas within a cell is a difficult and more complicated task. One reported study uses a hyperspectral darkfield microspectroscopy system that was developed in order to record the scattering spectra of cells labeled with molecular tags that scatter strongly in distinct spectral windows. This system operated using specific types of GNPs and requires a custom designed system29.

Another limitation stems from the diffraction limit. When imaged, each GNP becomes a point spread function (PSF) due to the diffraction limit set by the Rayleigh criterion30. As a consequence, areas with high GNPs concentration will appear as large spots. This can be a limitation for applications that require high precision for example, the defining of tumors for their guided surgical resection without damaging normal tissues or vital areas. In addition, this is also a limitation for localization microscopy techniques that require images with isolated PSFs that don't overlap31.

In this paper we use the temporally sequenced labeling (TSL) technique32 for the simultaneous detection of multiple GNPs labeling a sample and their separation at sub-diffraction distances. The proposed technique is simple and requires almost no additional components, therefore is such that existing setups could be altered to incorporate the proposed approach without a necessity for major modifications.

Theoretical background

The TSL technique uses lock-in detection to obtain higher contrast in single wavelength imaging of GNPs. Here we use M simultaneously modulated laser beams with wavelengths that match the GNPs plasmon resonance. Each laser is modulated with a known and different temporal frequency of ν0i, where i = 1…M is the index of the modulated laser. The light scattered from the sample is captured as a temporal sequence of intensity images, at a frame rate that is more than double the flickering rate (Nyquist rate)33. The intensity of each image is proportional to the sum of the temporally sampled modulated signals and some additive noise:

where It is the image intensity, Isig is the signal intensity without noise, Inoise is the noise intensity. A temporal spectral analysis is performed on the received sequence of spatial images. Since the information obtained from each type of GNP lies in a specific spectral component that corresponds to its modulation frequency, it can be extracted computationally. The post processing can be performed using any numerical package (e.g. MATLAB, MathWorks, Natick, MA, USA) for each modulation frequency separately. The reconstructed image is the average sum of the set of images convolved with the corresponding modulation frequency:

Where Imod is the intensity of the modulation signal, N is the number of the images that were captured and t = 1…N is the index of each image. The result is an image with distinct separation between the elements that have different modulation frequencies, even in cases were the two GNPs are at such sub-diffraction distance that in conventional method appear as a single spot. In addition, the wide spread spectrum noise is significantly attenuated in respect to the signal as the signal is correlated to a specific frequency, thus significantly increasing the SNR.

Simulations

To simulate the proposed method, we have generated a set of artificial data including random emitters at each set. In these simulations the model was of a sample that contains two types of GNPs with emission peak at wavelengths of λ1 = 532nm and λ2 = 785nm. The sample was illuminated simultaneously using two temporally modulated lasers at wavelengths that match the GNPs emission peaks. The frame rate was of 100 frames/s, ν01 = 13Hz and ν02 = 25Hz to match those of our experimental setup. Shot noise was added as a Poisson process with an expected value which corresponds to the noiseless pixel values and a standard deviation (STD) that equals the square root of the value of each pixel. Background noise was introduced by adding a sample from a Poisson distribution random variable with variance Nb (assumed constant across the field of view)34.

A sequence of time dependent images was generated and analyzed. Using the a priori knowledge of the temporal modulation frequencies, the set of images were convolved with each of the modulation signal frequencies separately, followed by time averaging. The result is two different images where each image contains a single type of GNP. The complete image of the sample is a simple sum of these two. Figure 1(a) is the simulated sample with random diffraction limited spots originating from scattering from the two types of GNPs. Noise was added to the image, corresponding to SNR of −10 dB (Fig. 1(b)). The SNR was calculated according to:

Figure 1
figure 1

Simulation results.

(a) The simulated sample with random diffraction limited GNPs. (b) A single image from the set of generated images with added noise, corresponding to SNR of -10dB. (c) The reconstructed image after applying the TSL technique for each frequency and summing the two images. The two types of GNPs are marked in red and green. The SNR of the reconstructed image is 30 dB.

The TSL was applied on each of the two frequencies, which yielded two different images. For visualization, the GNPs in each image were colored differently (in green and red, corresponding to laser wavelengths). The reconstructed image is a simple sum of the two (Fig. 1(c)). The calculated SNR is 30 dB. The proposed technique enables the extraction of the GNPs signal even at poor SNR of −50 dB. In addition, large diameter spots in the original image (Fig. 1(a)), are usually a result of close proximity GNPs. After the processing, individual GNPs become distinguishable within the spots, as can be seen in Fig. 1(c). The method's ability to detect overlapping types of GNPs, at distances much smaller than the diffraction limit, makes it attractive for super resolving localization microscopy techniques.

Materials and methods

Synthesis and conjugation of spherical GNPs

Spherical GNPs (shape 20nm, peak at wavelength of 532nm) were prepared using sodium citrate according to the known methodology described by Enustun and Turkevich35. 0.414 mL of 1.4 M HAuCl4 solution in 200mL water was added to a 250mL single-neck round bottom flask and stirred in an oil bath on a hot plate until boiled. 4.04mL of a 10% sodium citrate solution (0.39M sodium citrate tribasic dihydrate 98%, Sigma cas 6132-04-3) was then quickly added. The solution was stirred for 5 minutes and then the flask was removed from the hot oil and placed aside until cooled. The final concentration of the GNPs reaches 30mg/ml.

Uncoated spherical GNPs tend to aggregate because of their negative charge (due to the citric acid stabilizing ligand). One way to prevent aggregation it is to coat them with protein36. Another method we used in order to prevent aggregation and stabilize the particles in physiological solutions, 100μL O-(2-Carboxyethyl)-O′-(2-mercaptoethyl)heptaethylene glycol (PEG7) (95%, MW 458.56g/mol, Sigma-Aldrich, Israel Ltd.) was absorbed onto the nanospheres. This layer also provides the chemical groups required for antibody conjugation (-COOH). First, the solution was centrifuged to dispose of excess citrate. PEG7 solution was then added to the solution, stirred at room temperature overnight and put in a centrifuge in order to dispose of excess PEG7.

In order to increase cell-uptake rate, stabilized nanospheres were further coated with glucose. Excess of 100μL EDC (N-ethyl-N -(3-dimethylaminopropyl) carbodiimide) and 100μL NHS (N-hydroxysuccinimide) (Thermo Fisher Scientific, Inc, Rockford, IL) were added to the solution, followed by addition of 200μL Glucose-2 (2GF)(D-(+)-Glucosamine hydrochloride, Sigma-Aldrich, Israel Ltd.). NHS and EDC form an active ester intermediate with the -COOH functional groups, which can then undergo an amidation reaction with the glucose –NH2 group. The solution was stirred at room temperature for 3 hours and put in a centrifuge in order to dispose of excess materials. This protective layer prevents aggregation of the spherical GNPs within the biological sample37.

Synthesis and conjugation of rods GNPs

Rods GNPs (shape 15X55nm, peak wavelength at 785nm) were synthesized using the seed mediated growth method38. This method, charges the rods GNPs with a positive charge, which prevent their aggregation within a biological sample. A solution of GNRs suspended in cetyltrimethylammonium bromide (CTAB) (Sigma-Aldrich, USA) was centrifuged at 11 000g for 10 minutes, decanted and resuspended in water to remove excess CTAB. In order to stabilize the particles in physiological solutions, a layer of polyethylene glycol (mPEG-SH, MW 5000g/mol) (creative PEGWorks, Winston Salem, USA) was adsorbed onto the GNRs. This layer also provided the chemical groups that are required for antibody conjugation (SH–PEG–COOH, MW 3400g/mol). A 200ml mixture of mPEG–SH (5mM) (85%) and SH–PEG–COOH (1mM) (15%) was added to 1ml of GNR solution. The mixture was stirred for 24 hours at room temperature. The absorption spectrum of PEGylated GNR solution presented the same absorption peak at 785nm. The heterofunctional PEG was covalently conjugated to a CC49 monoclonal antibody, which is specific to the TAG-72 antigen39.

Cell uploading with spherical and rods GNPs

A431 cells were cultured in glucose-free DMEM medium containing 5% FCS, 0.5% penicillin and 0.5% glutamine. Cells were centrifuged and a saline solution at concentration of 0.9% containing nanospheres was added in excess. The cells were then incubated at 37ºC for 1.5 hour. After incubation, the cells were centrifuged twice (7  minutes in 1000 rpm) to wash out unbound nanospheres. Then, cells were incubated at 37 °C for 15 minutes with a saline solution containing gold nanorods. After incubation, the cells were centrifuged twice (7  minutes in 1000 rpm) to wash out unbound rods.

Experimental results

Samples of human epidermoid carcinoma cell line, A43140, were injected with 20nm spheres GNPs and 15nm x 50nm rods GNPs immobilized on a coverslip, using a known protocol32,41 (the sample preparation is described in the methods section). Particles characteristics were measured using transmission electron microscopy (TEM) where the spheres diameter was verified to be 20 nm (Fig. 2(a)), the rods dimensions were verified to be 15nm × 50 nm (Fig. 2(b)). Their absorption spectrum was measured (using the NanoDrop2000c by Thermo-Scientific) and is shown in Fig. 2(c). The spheres are marked in black, where a clear peak at 532nm is presented. The rods GNPs are marked in red and have two peaks; the dominant is at 785nm that is stronger by a factor of 2.5 than the minor peak that is located at 532nm. This minor peak is 2 times weaker than the same peak of the spheres GNPs. The scattering peak of the GNPs was also measured using a visible spectrophotometer (Cary 5000 by Agilent) and demonstrated the same ratios between the peaks as presented in Fig. 2(c).

Figure 2
figure 2

Characterization of GNPs.

(a) TEM image of spheres GNPs. (b) TEM image of rods GNPs. (c) Absorption spectrum of the GNPs.

The GNPs weren’t targeted into a specific area within a cell and therefore they are randomly distributed inside the cells42. In order to visualize the effect of different types of GNPs on the scattering of the cells, 4 different samples were imaged using a dark-field microscope (Nikon i50). The first sample was a control set with cells only (Fig. 3(a)). The second sample was cells tagged with spherical GNPs. Due to their scattering peak they make the cell appear green (Fig. 3(b)). The third sample was cells tagged with rods GNPs. Here, due to their dominant scattering peak they make the cell appear red (Fig. 3(c)). The last sample was of cells that were tagged with both spherical and rods. Therefore, the cells appear to contain both green and red (Fig. 3(d)).

Figure 3
figure 3

Dark field image of 4 different samples.

(a) Cells only. (b) Cells tagged with spherical GNPs. (c) Cells tagged with rods GNPs. (d) Cells tagged with both spherical and rods GNPs.

The proposed method was tested using the experimental setup that is described in Fig. 4.

Figure 4
figure 4

The experimental setup is made of a function generator with two outputs, that modulate a green laser at wavelength of 532nm and a red laser at wavelength of 785nm at two frequencies of ν01 = 13Hz and ν02 = 25Hz respectively.

The modulated beams illuminate the sample and the scattered light is recorded as function of time using a CMOS camera.

A function generator (AFG3022B by Tektronix) was used to create two square waves with known frequencies of ν01 = 13Hz and ν02 = 25Hz (that fulfil the Nyquist sampling criteria as the frame rate of the camera was 215 frames/s) and a duty cycle of 50%. The first signal at ν01was connected to the modulation port of a green laser at 532nm (Photop DPGL-2100F) and the second signal at ν02 was connected to the modulation port of a red laser at 785nm (Oxxius LBX-785S). The modulated beams illuminated the sample and the scattered light as a function of time was recorded using a CMOS camera (PixeLink PL-A741-E). The images were taken with parameters of the highest gain of the camera (17.7 dB), low exposure time (10ms) and low laser powers (6 mW) to mimic high background and significant shot noise conditions. The SNR of the set of images was calculated to be -27 dB. Figure 5 presents a sequence of recorded images of the scattered light from the sample with -27 dB SNR where the GNPs are indistinguishable from the noise. A bright field image of the sample at a size of 750 × 650 pixels was taken with the Olympus BX51 microscope using X40 objective lens (Fig. 6(a)). The TSL technique was applied to the sequence of recorded images first with the frequency ν01, followed with the same processing at ν02. Since the rods GNPs also have a minor scattering peak at 532nm, the same as that of the spheres, the processed image with ν01 contains both the spherical and the rods GNPs. Therefore, the processed image with ν02, that contains only the rods GNPs, was subtracted from the ν01 image and the result was two images, one for each type of GNP. The final image that represents the two types of GNPs in the sample is the sum of the two images, where for visualization, each type was colored differently, in green and red (Fig. 6(b)). Figure 6(c) is the superimposing of Fig. 6(a,b). The overlap between the locations of the GNPs to that of the cells, indicates that the GNPs are concentrated inside the cells and by using the ability to attach the GNPs to a specific area within a cell, the proposed technique provides a tool to study intra-cellular processes.

Figure 5
figure 5

A sequence of recorded images of light scattered from the sample having -27 dB SNR.

The irradiation was generated using two laser beams (at wavelengths of 532nm and at 785nm) with modulation frequencies of 13Hz and 25Hz respectively.

Figure 6
figure 6

Expeirmentally extracted images.

(a) A bright field image of the sample. (b) The reconstructed image of the sample using TSL for each of the two frequencies (marked in green and red). (c) The superimposing of (a) and (b).

In order to validate the ability of the method to detect overlapping GNPs, a reference image of the sample was taken using continuous illumination with the two lasers at high power of 50 mW. The obtained image was of all the GNPs in the sample, where areas of overlapping GNPs appear as larger spots. Figure 7(a) is a zoom-in on a 40 × 50 pixels area inside the sample that contains three spots. The same area with the proposed method is presented in Fig. 7(b), where each of the spots contain two different types of GNPs. The experimental results validated the proposed concept.

Figure 7
figure 7

Experimental results.

(a) Zoom-in on an area inside the sample that contains three spots. The image was captured under conditions of continuous illumination of the sample with the two lasers at high power of 50 mW. (b) The same area with the proposed method, where each of the spots contains two different types of GNPs.

Discussion and conclusions

The TSL technique is an alternative approach for imaging a sample that is labeled with GNPs that provides a tool intra-cellular processes study. It allows the simultaneous detection of multiple types of GNPs within a biological samples or cells and provides high noise immunity which makes it ideal for biological applications. There are various applications for the proposed technique. One is the detection of clustered GNPs, which results in a high resolution image of the sample. In addition, by targeting each type of GNPs to different areas within biological samples or cells, the cite-specified areas within the sample can be simultaneously imaged. Another application can be used in a reported technique that detects multiple types of GNPs within a sample and performs multicolored nanometer-resolution mapping of single proteins43. This technique requires the use of a multispectral imaging system, whereas applying our proposed technique, requires only a simple camera, rather than a complex system. The TSL method is generic and can be applied to variety of cells and different types of GNPs, given the appropriate laser's wavelength.

Additional Information

How to cite this article: Ilovitsh, T. et al. Cellular superresolved imaging of multiple markers using temporally flickering nanoparticles. Sci. Rep. 5, 10965; doi: 10.1038/srep10965 (2015).