Abstract
We investigated the effects of direct current stimulation (DCS) on fluid and solute transport across endothelial cell (EC) monolayers in vitro. Our motivation was transcranial direct current stimulation (tDCS) that has been investigated for treatment of neuropsychiatric disorders, to enhance neurorehabilitation, and to change cognition in healthy subjects. The mechanisms underlying this diversity of applications remain under investigation. To address the possible role of blood-brain barrier (BBB) changes during tDCS, we applied direct current to cultured EC monolayers in a specially designed chamber that generated spatially uniform direct current. DCS induced fluid and solute movement across EC layers that persisted only for the duration of the stimulation suggesting an electroosmosis mechanism. The direction of induced transport reversed with DCS polarity – a hallmark of the electroosmotic effect. The magnitude of DCS-induced flow was linearly correlated to the magnitude of the applied current. A mathematical model based on a two-pore description of the endothelial transport barrier and a Helmholtz model of the electrical double layer describes the experimental data accurately and predicts enhanced significance of this mechanism in less permeable monolayers. This study demonstrates that DCS transiently alters the transport function of the BBB suggesting a new adjunct mechanism of tDCS.
Similar content being viewed by others
Introduction
Transcranial direct current stimulation (tDCS) is being investigated for treatment of a broad range of neuropsychiatric disorders (e.g. depression, neuropathic pain, epilepsy1), as an adjunct to rehabilitation (e.g. stroke2, traumatic brain injury3), and to facilitate cognitive performance in healthy individuals (e.g. accelerated learning4). Validating the efficacy of tDCS and optimizing therapy dose, requires an understanding of the underlying mechanisms, including the cellular targets of tDCS – which cell types are directly activated. Efforts spanning decades5 have quantified the effects of DCS on neurons, even identifying which neurons6 and neuron compartments7 are more sensitive. A role for glia has also been proposed8,9. Here we address a novel cellular target for DCS - the endothelial cells (ECs) that form and regulate the blood-brain-barrier (BBB). We previously developed an in vitro cell culture model of BBB stimulation, where alternating current pulses mimicking deep brain stimulation protocols induced increases in water flux across EC monolayers through disruption of tight junctions between ECs10. In the present study, we adapt this system to examine the physiological effects of simulated tDCS protocols on endothelial transport properties.
There is a compelling body of indirect evidence suggesting BBB activation by tDCS. Imaging studies show tDCS changes cerebral perfusion in humans11,12,13 and animals14, though these data cannot distinguish between changes in BBB function secondary to neuronal stimulation or direct electrical stimulation of the BBB. The most evident physiological outcome of tDCS is skin vascular response reflected in erythema5,15,16, though current density is much higher at the skin. However, given a robust current-mediated skin vascular reaction during tDCS, it is reasonable to consider the possibility of such a change within the brain. Finally, long-duration/low-intensity electric fields have been shown to stimulate vascular endothelial growth factor production, and directed reorientation of ECs17,18. Therefore, the hypothesis of direct modulation of BBB function by direct current stimulation (DCS) is of interest.
A biophysical mechanism that could lead to transport of water and solutes across the BBB in response to an applied electric field is electroosmosis19. This process derives from the movement of charged ions through small channels or pores that have fixed charge on their surface. A layer of mobile charge (double layer) near the fixed charge is able to move in response to an electric field applied parallel to the surface. This mobile charge drags surrounding medium resulting in net fluid and associated solute transport through the pore. The direction of the net fluid flow can be reversed by changing the polarity of the applied electric field. Direct current produces a sustained direction of electroosmotic transport. The relative importance of electroosmosis is amplified in very small channels (micro, nano) where the hydrodynamic resistance limits pressure-driven convection. The paracellular transport pathways across endothelial layers typically have a fixed negative charge on their surface and are of nano-scale dimensions20 suggesting that electroosmosis may be an important mechanism of transport in the presence of an applied electric field. Sanchez et al. have provided evidence suggesting electroosmosis, arising as a result of spontaneously generated circulating currents, as a primary mechanism of fluid transport in the corneal epithelium21.
To begin to address the possible role of the BBB in tDCS efficacy and safety, we applied 10 minutes of DCS characteristic of tDCS to monolayers of cultured ECs and measured their transport barrier responses. We found that DCS produced significant stimulation-polarity-specific fluid and solute movement across the EC layer that persisted only as long as the current was applied and was enhanced in cells with tighter junctions – all characteristic of the electroosmotic effect. A mathematical model based on a two pore description of the endothelial transport barrier and a Helmholtz model of the electrical double layer describes the experimental data accurately and predicts enhanced significance of this mechanism in tighter (less permeable) monolayers.
Materials and Methods
Cell culture
Immortalized mouse brain endothelial cells, bEnd.3, were obtained from American Type Culture Collection (Manassas, VA) and cultured in Dulbecco’s modified Eagle’s medium (DMEM; Sigma, St. Louis, MO) supplemented with 10% fetal bovine serum (FBS; Hyclone, Logan, UT), 3 mM L-glutamine (Sigma, St. Louis, MO) and 1% penicillin-streptomycin (Sigma, St. Louis, MO). bEnd.3 s were plated at 6 × 104 cells/cm2 in Transwell filters (1.1 or 4.67 cm2 membrane area, 0.4 μm pores; Corning, Lowell, MA) coated with fibronectin (Sigma, St. Louis, MO) and cultured for 4–5 days before transport experiments. Experimental media consisted of phenol-red free DMEM (Sigma, St. Louis, MO) supplemented with 1% bovine serum albumin.
Measurement of solute and water flux
Simultaneous measurement of solute and water flux was achieved with an apparatus developed in our lab (Fig. 1) and used in several previous studies of endothelial transport22,23. The apparatus was kept inside a Plexiglass hood and maintained at 37 °C. The flux of 70 kDa tetramethylrhodamine isothiocyanate-tagged dextran (Sigma, St. Louis, MO) or 5-carboxytetramethylrhodamine (TAMRA, 430 Da; Sigma, St. Louis, MO) was measured using an automated fluorometer system which has been described elsewhere22. Briefly, the Transwell filter containing a cell monolayer was sealed within a transport chamber, forming luminal and abluminal compartments. Transport of water and solutes occurred solely across the cell monolayer. The abluminal compartment was connected to a fluid reservoir via tygon tubing and borosilicate glass tubing. The reservoir could be lowered to apply a hydrostatic pressure differential across the monolayer. The concentration of fluorescently tagged solute in the abluminal compartment was measured with a Model D48 photon counting detector (C&L Instruments; Hershey, PA). Excitation light at 532 nm was provided by a 10-mW Crystal Laser. The FluorMeasure acquisition software and Model PC-DAQ control card (C&L Instruments) were used to control the laser exciter and detector, and for data acquisition.
Permeability was calculated as follows:
where ΔCa/Δt is the change in abluminal concentration per unit time, Va is the fluid volume in the abluminal compartment, Cl is the concentration in the luminal compartment (assumed to remain constant over the course of the experiment), and A is the area of the filter.
The water flux (Jv) was measured by tracking the position of an air bubble that was inserted into the glass tubing using an automated bubble tracking system24. The bubble displacement was used to compute Jv values by
where Δd/Δt is the bubble displacement per unit time and F is a tube calibration factor equal to the fluid volume per unit length of tubing. Simultaneous solute and water flux experiments carried out in the apparatus described above (Fig. 1) used the small Transwell (1.1 cm2). To achieve lower current densities, a larger Transwell (4.67 cm2) was used in a similar apparatus equipped only to make water flux measurements using the same bubble tracker system described above.
Direct current stimulation
Direct current stimulation was achieved by means of a pair of Ag/AgCl electrodes (4 mm × 1 mm disk; A-M Systems, Sequim, WA) positioned 6 mm above and below the cell monolayer. On experiments using the large Transwell membrane, Ag/AgCl electrodes were 8 mm × 1 mm disks positioned 14 mm above and below the cell monolayer. A transcranial Direct Current Stimulator (model 1300-A, Soterix Medical, New York) was used to apply 0.1–1.5 mA current across the monolayers for 10 minutes. The current was ramped up to the final value over 30 seconds and ramped down to zero over 30 seconds. This current level and duration are typical of tDCS applications in patients with neurological disorders1.
In a typical experiment, the Transwell filter was rinsed twice with experimental medium before being inserted into the transport chamber. A solution of 5 μg/mL of 70 kDa dextran or 0.65 μM TAMRA was added to the luminal compartment. Each transport experiment began by lowering the abluminal reservoir to apply a 10 cm H2O pressure differential (to drive convective flux). Data were collected for 60 min to obtain baseline values of the water and solute fluxes. For convective experiments, DCS (1 mA) was then immediately applied for 10 min, and water and solute flux data were collected under the combined influence of the pressure differential and DCS. After DCS application, data were collected for up to 120 min under convective conditions. For diffusive experiments, after 60 min of convection the abluminal reservoir was raised to its original level and the flux was allowed to equilibrate for 30 min before application of DCS for 10 min. After DCS application, data were collected for up to 120 min under diffusive conditions.
Immunostaining of bEnd.3 monolayer with ZO-1
Following some experiments, bEnd.3 monolayers were immunostained for the tight junction protein ZO-1 to assess monolayer integrity. After 60 min of convective flux, control (no DCS) and DC-stimulated monolayers were washed with PBS and fixed in 1% paraformaldehyde (PFA; Polysciences Inc., Warrington, PA) for 10 min. Monolayers were then permeabilized with 0.2% Triton X-100 for 10 min, blocked with 10% goat serum and 0.1% Triton X-100 for 1 hr, and incubated with primary rabbit anti-ZO-1 antibody (1:200; Invitrogen, Rockford, IL) overnight at 4 °C. After washing 5X with PBS, ZO-1 was detected with AF555 goat anti-rabbit IgG secondary antibody (1:500; Life Technologies Inc, Eugene, OR) for 60 min at room temperature. After washing 4X with PBS, monolayers were counterstained with DAPI nuclear stain and mounted with Fluoromount (Southern Biotech, Birmingham, AL). Imaging was conducted in a Zeiss LSM 510 Confocal Laser Scanning system at 40X/oil magnification.
Mathematical model of electroosmosis
To interpret the experimental transport data, a mathematical model of electroosmosis was developed.
Model geometry
We use the simplified structure for the junction between two endothelial cells proposed in Fu et al.25. The junction strand is idealized as periodic units consisting of a large pore and a continuous narrow slit. A single unit is shown in Fig. 1 (top right insert). The tight junction (TJ) has a narrow slit of height 2bs and width WTJ which allows current but not fluid flow. The central orifice of height 2B and width WB is the break in the TJ strand and allows both fluid and current flow.
Model description
Charge separation that occurs naturally at biological interfaces leads to the formation of an electrical double layer. Electroosmotic flow is caused by the force induced by an electrical field on the mobile portion of the double layer. The derivation of the flow and current through the junction follows that presented by Grodzinsky19 for a cylindrical pore, but with the 2-pore slit geometry shown in Fig. 1. We assume that the two types of pores (TJ and break) are arranged in parallel and there is no interaction between them, i.e., there is no current or fluid flow in the lateral x direction (Fig. 1C). If the liquid in the pores is treated as a Newtonian fluid, and inertial forces are neglected, the governing equation for fluid flow in the presence of an electrical field is
where p is the pressure, v is the velocity, ρe is the charge density, and E is the applied electrical field. In the z-direction, we assume fully developed flow such that v = vz(y), ρe = ρe(y) and \({\rm{\partial }}p/{\rm{\partial }}z={\rm{\Delta }}p/{\ell }_{p}\), where Δp is the pressure drop across the pore and \({\ell }_{p}\) is the length of the pore (thickness of EC in the junction region), as shown in Fig. 1. We also assume that the y-component of the electrical field, which is due to the electrical double layer, is much greater than the applied electrical field and, therefore, unaffected by it (see Appendix). Then, the governing equation is written as
where ε is the permittivity of the fluid, ΔV is the potential drop across the length of pore, and Φ(y) is the electrical double layer potential as a function of distance from the wall. Equation (4) can be integrated twice using the boundary conditions \({\rm{\partial }}{v}_{z}/{\rm{\partial }}y={\rm{\partial }}{\rm{\Phi }}/{\rm{\partial }}y\equiv 0\) at y = 0 by symmetry, and vz = 0, \({\rm{\Phi }}\equiv \zeta \) at the mechanical slip plane y = ±(B − δ) to obtain an expression for the velocity
ζ is the potential at the slip plane, the so-called zeta potential, which occurs not at the wall but several water molecule diameters away from the wall at y = B − δ. After substituting for the potential function, Φ(y) (see Appendix), Equation (5) can be integrated over the cross-sectional area of a large break pore to obtain the volume flow through the pore
where WB is the width of the break in the TJ strand. To relate this equation to the flux data obtained, we first define the total number of pores as
where nB is the number of large break pores in the junction strand, nTJ is the number of narrow slit pores in the strand, Ljt is the total length of the junction strand per unit area, Am is the area of the monolayer, and \(f\) is the fraction of Ljt that is tight junction (narrow slit). Multiplying equations (6) by (7) and rearranging we obtain an equation for Jv:
To calculate ΔV from the known applied current density (Ji) we first obtain an expression for the current through each pore, which can be defined in terms of a sum of a pressure-driven flow term and a conduction term19 (see Appendix):
where iB is the current through the break pore, iTJ is the current through the TJ pore, σ is the fluid conductivity, and d is the Debye length (see Appendix). For our slit geometry, assuming the pores form a parallel circuit, the total applied current (iTOTAL) is equal to the sum of the currents across all the pores. Using equations (7) and (8), and noting that Ji = iTOTAL/Am, we obtain the following expression for the total applied current density:
The anatomical cell parameters and fluid properties in equations (9) and (11) are either known, can be calculated or be estimated. Table 1 shows the values used in our calculation. Finally we define the electroosmostic flow enhancement, E, as follows
where JvDCS is the flow induced by the application of DCS (the second term on the right hand side of equation (9)) and JvΔp is the flow induced by the pressure gradient (first term on the right hand side of equation (9)). To fit our data to the model, the baseline Jv data is first used to estimate B in equation (9) when ΔV = 0. Then equations (11) and (9) are used to calculate E, with ζ as the parameter varied to optimize the coefficient of determination (R2) for the model.
Statistical analysis
Data are presented as mean and standard deviation (SD). Statistical analysis was performed using either paired or unpaired t-tests with p < 0.05 considered significant. Where multiple comparisons were made (e.g. for comparisons of baseline, DCS and post-DCS data) Bonferroni’s correction was used to reduce the p-value considered significant to 0.5 divided by the number of comparisons (e.g. for three comparisons p < 0.016 was considered significant). GraphPad Prism was used to perform statistical analysis and to generate data plots.
Data availability
All data generated or analysed during this study are included in this published article (and its Supplementary Information files).
Results
Effect of DCS polarity and current on water flux
Jv was measured before, during, and after application of 10 min of 1 mA DCS from the basal to apical side of the monolayer (B-A polarity, cathode on top of monolayer) and apical to basal (A-B polarity; anode on to top of monolayer) directions (Fig. 2A). Application of DCS produced an immediate and transient response in Jv. The direction of change in Jv was dependent on the polarity of the applied electric field, while its magnitude was independent of the polarity (Fig. 2B). For the bEnd.3 monolayers in Fig. 2B, an average decrease in Jv of 3.10 × 10−6 cm/s (SD 1.31 × 10−6) in the B-A direction was not significantly different from an average increase in Jv of 4.05 × 10−6 cm/s (SD 0.76 × 10−6) in the A-B direction. Both changes were significantly different from the baseline Jv calculated 5 minutes before DCS application (P = 0.007 and P = 0.0002, respectively).
Application of DCS at increasing current magnitude (0.5, 1, and 1.5 mA; current density (Ji) = 4.54, 9.09, and 13.64 A/m2, respectively) induced changes in Jv of increasing magnitudes (2.43 × 10−6cm/s (SD 0.44 × 10−6), 4.49 × 10−6 cm/s (SD 0.39 × 10−6), and 6.85 × 10−6 cm/s (SD 0.71 × 10−6), respectively; Fig. 3A). After each DCS application, Jv returned to the baseline value. To evaluate whether the effect extended to lower current densities, current magnitudes of 0.1, 0.5, and 1 mA where applied to a larger Transwell (4.67 cm2) corresponding to Ji of 0.21, 1.07, and 2.14 A/m2 respectively. These lower current densities resulted in statistically significant increases in Jv (2.61 × 10−7 cm/s (SD 1.56 × 10−7; P = 0.009), 3.58 × 10−7 cm/s (SD 1.7 × 10−7; P = 0.001), and 8.31 × 10−7 (SD 1.75 × 10−7; P = 2 × 10−7), respectively; Fig. 3B). The magnitude of the DCS-induced flow (JvDCS) showed a strong linear correlation with the magnitude of the applied current density (R2 = 0.98; Fig. 3B).
The rest of the experiments in this study were carried out at 1 mA in the 1.1 cm2 Transwell and with the A-B direction to drive the flow in the same direction as the ΔP-induced flow, i.e. from apical to basal side of monolayer, which is the physiological direction in which ECs experience flow. Visual inspection and immunostaining of the monolayers showed no damage to the monolayer integrity after DCS (Fig. 4), a fact supported by the immediate recovery of baseline Jv after DCS is terminated.
Effect of DCS on water and solute flux
The effect of 1 mA DCS on Jv across bEnd.3 monolayers is summarized in Fig. 5. bEnd.3 monolayers had baseline Jv of 1.79 × 10−6 cm/s (SD 1.24 × 10−6), consistent with previous measurements26. Upon application of 1 mA DCS, bEnd.3 monolayers experienced an immediate significant increase in water flux (2.88-fold, p = 3.1 × 10−5). Jv after DCS is turned off was not significantly different from baseline (p = 0.97).
Figure 6 summarizes the effects of DCS on bEnd.3 permeability to 70kDa-Dextran and TAMRA. Under convective conditions, i.e. with a hydrostatic pressure gradient driving flow that can convect solute, bEnd.3 monolayers had baseline permeabilities of 7.5 × 10−7 cm/s (SD 1.0 × 10−6) for 70kDa-Dextran and 4.5 × 10−6 cm/s (SD 1.4 × 10−6) for TAMRA (Fig. 6A,B). DCS application increased bEnd.3 permeability to 70kDa-Dextran (by 2-fold to 1.5 × 10−6 cm/s (SD 1.4 × 10−6); p = 7 × 10−5), but had no effect on the permeability of TAMRA (p = 0.41). Under diffusive conditions with no pressure driven flow, DCS increased 70kDa-Dextran permeability by 5.5-fold (p = 0.004) from 1.1 × 10−7 cm/s (SD 5.7 × 10−8) to 6.0 × 10−7 cm/s (SD 3.7 × 10−7) but had no effect (p = 0.47) on TAMRA permeability (Fig. 6C,D).
Model Results
Figure 7 shows electroosmotic enhancement predictions of the model along with the experimental values obtained at the same current density. The model is in excellent agreement with the experimental data, with an R2 of 0.94. The value of ζ used to optimize the fit, −20.5 mV, is in the range of values previously measured for biological materials such as mouse neuroblastoma cells, −15 mV27, and rat organotypic hippocampal cultures, −22 mV28. The data and the model show the strong trend of greater enhancement for tighter monolayers (lower JvΔp).
Discussion
The goal of this study was to isolate and quantify the effects of DCS on endothelial layers that model the BBB. To this end, we exposed bEnd.3 monolayers grown on Transwell membranes to a low level of direct current of (1 mA) for 10 minutes (typical of tDCS human trials29) and measured water and solute flux before, during, and after DCS. We report that DCS induced an immediate increase in water flux that persisted during DCS, and immediately returned to baseline value when DCS was turned off. We also demonstrated that the direction of water flow could be reversed by reversing the direction of the applied current (Fig. 2). In addition, we showed that the magnitude of DCS-induced flow is linearly correlated to the applied current density, and that the effect persists at current densities experienced in the brain during tDCS30,31 (Fig. 3).
These results point to an electroosmotic mechanism of action. Electroosmotic flow is the motion of fluid induced by an applied electrical potential across a fluid channel that contains an electrical double layer19. Electroosmotic flow is most significant in smaller channels where pressure driven flow is low due to higher hydrodynamic resistance (Equation 12; Fig. 7).
Solute flux experiments using 70 kDa Dextan and TAMRA (430 Da) showed significant increases in the permeability of the larger solute, while there was no measureable increase in the permeability of the smaller solute. The relative increase in permeability (for 70 kDa Dextran) was even greater when the experiment was carried out under diffusive conditions (no applied pressure differential). We can infer from these results that the effect of DCS on solute permeability is due to an increase in convection through the large pores (breaks in the TJ) rather than an increase in the number or width of the pores. If there had been an increase in the total number of pores, we would expect to see an increase in the permeability of the small solute, whose transport is diffusion dominated.
A mathematical model of electroosmotic flow was developed using an idealized two pore geometry for the junction between two endothelial cells and a Helmholtz model for the electrical double layer. The model accurately replicated the experimental data (Fig. 7). In our analysis, we have used an idealized model of the nanoscale features of the cell-cell junction to calculate the potential drop, ΔV, across the EC monolayer (Equation 11). Using the macroscale electrical properties of the EC monolayer, ΔV could also be defined as
where iTOTAL is total applied current, and RTOTAL is the total resistance of the EC monolayer. TEER is the transendothelial electrical resistance, defined as RTOTAL multiplied by the area of the monolayer (Am), and is a parameter widely used to characterize the barrier properties of endothelial monolayers32. Substituting this equation for ΔV in Equation (12), it is apparent that monolayers with higher TEER, i.e. tighter monolayers, would experience higher flow enhancement at the same applied current density and pressure drop:
The use of a cultured endothelial cell monolayer does not fully reflect the physiological behavior of the intact BBB. However, a recent in vitro study of co-culture models of the BBB that included astrocytes and basement membrane components along with ECs (bEnd.3) demonstrated that co-culture components did not significantly reduce the hydraulic conductivity or solute permeability compared to EC monoculture, and found cultured bEnd.3 to be a good in vitro model for transport of large solutes when compared to in vivo models26. An additional limitation of our study is that solute flux experiments were conducted at a current density (9.09 A/m2) larger than what brain tissue is predicted to experience (0.2 A/m2)30,31. However, since the solute flux data shows that the effect on solute flux is due to the DCS-induced increase in convective flow, and we have shown that DCS-induced flow persists at current densities similar to those experienced in the brain (Fig. 3B), it is reasonable to expect that solute effects would be present at current densities lower than used in the present study, and that these effects would scale with current density magnitude.
It should also be noted that computational models used to predict current density in the brain due to tDCS do not include the vasculature and its potential contribution to current distribution and local current density. These models predict electric field and current density for the ‘bulk’ brain extracellular space. If one assumes blood vessels are transparent to current flow, then the current density across the BBB would be the same as bulk brain. More likely, as the resistivity of the BBB and blood is different from brain, microscopic current flow will be altered. We hypothesize that as blood is more conductive than brain parenchyma, the vasculature provides a relatively attractive path for current flow. Depending on the vascular morphology (capillary organization), current will cross in and out of the BBB at specific points, and at these locations current density may be several fold higher than in the bulk brain, corresponding to the higher current densities tested here. Interestingly, even for the same current density as bulk, the electric field across the BBB during tDCS would be orders of magnitude higher than bulk because of the resistivity of the BBB. Our experimental system applies stimulation directly across the BBB model–very different than tDCS (in vivo) or brain slice models. For these reasons current density (not electric field) is reasonable to control and report, and values tested here span a range of potential in vivo tDCS values. For similar reasons, the use here of “anode on top” or “cathode on top” to describe directionality across the Transwell (BBB model) should not be confused with anodal or cathodal tDCS describing direction across the bulk brain33. The polarity dependence of tDCS is complex7,34,35,36 and additional analysis would be needed before speculating on the role of asymmetric vascular morphology37 in mediating any such dependence30.
We also note that microvessels in the BBB are expected to provide a much tighter transport barrier than our cultured monolayers. We have measured the TEER of cultured bEnd.3 monolayers and found values of ~40 Ωcm2. Measurements in rat cerebral microvessels in vivo show an average TEER of order 1000 Ωcm2,38. Based on the relationship between TEER and electroosmotic flow enhancement (Equation 14) we can expect large increases in water and solute flux in BBB microvessels in vivo, even at a reduced current density. According to our theory, change in transport during DCS electroosmosis is linear with stimulation intensity (Equation 14; Fig. 3) and there is no threshold for inaction.
Although we have shown that the effects of DCS on endothelial layers can occur independent of direct neuron stimulation, changes in BBB function may influence neuronal activity and plasticity. The main effect found in the present study is an increase in water flux upon DCS application. At the lowest current density tested (0.214 A/m2), the induced flux was ~2.6 × 10−7 cm/s (Fig. 3B), similar to estimates of interstitial flux in brain parenchyma (~3 × 10−7 cm/s39). Increased interstitial flow around neurons, driven by DCS-induced increase in water flux across the BBB may affect neurons directly through the fluid shear stress imposed upon them or indirectly by the clearance of local metabolites. Recent studies of the enhancement of brain function by elevated interstitial flow during sleep support this idea40. Studies in other cell types, such as smooth muscle cells and fibroblasts41, and cancer cells42, have shown that very low levels of interstitial flow can affect gene and protein expression as well as physiological function through fluid shear stress. The degenerin channels of C. elegans touch receptor neurons displayed a rapid response to imposed laminar shear stress43. Shear stress increased intracellular Ca2+ levels in cultured adult astrocytes44.
In addition, the ECs themselves are exposed to increased interstitial shear stress as a result of the increased water flux through their junctions. It is well established that ECs modulate their gene and protein expression in response to fluid shear stress on their apical surface45,46. Most notably, shear stress upregulates the endothelial nitric oxide synthase (eNOS) gene47, protein expression48, and the production of the neurotransmitter nitric oxide (NO) by ECs49,50. But increased flow through EC junctions also increases NO production51.
In conclusion, this is the first study to isolate and explain a significant response of ECs to low levels of DCS. We have shown that exposing endothelial monolayers to DCS induces an increase in water and solute flux. This increase is immediate, transient, and reversible, consistent with electroosmosis as the mechanism of action. These findings reveal a new mechanism that may contribute to the aggregate changes in neuronal activity produced by tDCS. Given the central role of transport across the BBB in brain function, the significant and reversible changes in transport reported here, could influence cellular and network function through a cascade of mechanisms52,53,54,55,56,57. Many of the metabolic, chemical, and neurophysiological consequences of tDCS58,59,60,61,62,63,64,65, and thus behavioral/clinical outcomes, could theoretically be explained by BBB stimulation. The cellular targets of tDCS remain to be investigated; this paper shows EC stimulation is a new plausible target.
Appendix
This appendix describes details of the mathematical formulation of the electroosmosis model and assumptions used to solve it.
Electrical Force Density
The electrical force density in the z-direction, ((ρeE)z) in Equation 3, can be obtained using Gauss’s law to substitute for ρe
where ε is the permittivity of the fluid. We then assume that Ey is solely due to the ionic atmosphere and is unaffected by fluid flow in the pore
where Φ(y) is the electrical double layer potential. The applied electrical field, Ez, can be written in terms of the potential drop, ΔV, across the length of the pore, \({\ell }_{p}\), such that Equation A1 becomes
Substituting Equation A3 into the governing equation (Equation 3) yields, in the z-direction,
The boundary conditions are:
Integrating A4 twice and applying A5 yields an equation for the velocity in the z-direction
Helmholtz double layer
As in19, we assume a Helmholtz double layer in order to obtain analytical solutions for the volume flow through a break pore, QB, and the current flow through break and TJ pores, iB and iTJ, respectively. This leads to an approximation of the potential function as19
where d is the thickness of the double layer (equal to the Debye length (d = 1/κ)), and it’s been assumed that d << B. Note that the y-origin is placed in the middle of the slit (Fig. 1C), and the function Φ(y) has been written for the positive half of the slit. The Debye length is given by
where R is the universal gas constant, T is the temperature, z is the ion valence, F is the Faraday constant, and ci0 is the bulk concentration of the ith species. Equation A8 assumes a single symmetrical electrolyte. For the case of the culture media used in the present study (DMEM), the major electrolyte is NaCl (ci0 = 0.1197 M). At T = 310 K, using Equation A8, d = 0.9 nm.
Volume flow
The volume flow through a break pore can be obtained by first substituting Equation A7 for the double layer potential into the velocity equation (Equation 5) and then integrating over the cross-sectional area to obtain the flow though half the slit pore. By symmetry, the flow though the entire pore becomes
where the third integral recognizes that Φ(y) = 0 in the range 0 ≤ y ≤ B-d. Using the assumption that B >> d >> δ, Equation A9 reduces to Equation 6.
Current flow
The current flow through each type of pore is defined in terms of sum of conduction and flow terms19
For the small TJ pore (narrow slit in Fig. 1), we assume no flow occurs due to high hydrodynamic resistance (vz = 0) so that only the conduction term remains. Although the fluid conductivity (σ(y)) can generally vary with y, we assume it to be uniform over the pore cross section. Using Equations A1-A2 to substitute for ρe in terms of Φ(y), then subsequently using Equation A7 to substitute for Φ(y), and assuming that B >> d >> δ, Equations A10 and A11 reduce to Equation 10.
References
Brunoni, A. R. et al. Clinical research with transcranial direct current stimulation (tDCS): challenges and future directions. Brain Stimul 5, 175–195 (2012).
Marquez, J., van Vliet, P., McElduff, P., Lagopoulos, J. & Parsons, M. Transcranial direct current stimulation (tDCS): does it have merit in stroke rehabilitation? A systematic review. Int J Stroke 10, 306–316 (2015).
Sacco, K. et al. Concomitant Use of Transcranial Direct Current Stimulation and Computer-Assisted Training for the Rehabilitation of Attention in Traumatic Brain Injured Patients: Behavioral and Neuroimaging Results. Front Behav Neurosci 10, 57 (2016).
Clark, V. P. & Parasuraman, R. Neuroenhancement: enhancing brain and mind in health and in disease. Neuroimage 85(Pt 3), 889–894 (2014).
Brunoni, A. R., Fregni, F. & Pagano, R. L. Translational research in transcranial direct current stimulation (tDCS): a systematic review of studies in animals. Rev Neurosci 22, 471–481 (2011).
Radman, T., Ramos, R. L., Brumberg, J. C. & Bikson, M. Role of cortical cell type and morphology in subthreshold and suprathreshold uniform electric field stimulation in vitro. Brain Stimul 2, 215–228, 228.e211–213 (2009).
Rahman, A. et al. Cellular effects of acute direct current stimulation: somatic and synaptic terminal effects. J Physiol 591, 2563–2578 (2013).
Gellner, A. K., Reis, J. & Fritsch, B. Glia: A Neglected Player in Non-invasive Direct Current Brain Stimulation. Front Cell Neurosci 10, 188 (2016).
Monai, H. et al. Calcium imaging reveals glial involvement in transcranial direct current stimulation-induced plasticity in mouse brain. Nat Commun 7, 11100 (2016).
Lopez-Quintero, S. V. et al. DBS-relevant electric fields increase hydraulic conductivity of in vitro endothelial monolayers. J Neural Eng 7, 16005 (2010).
Giorli, E. et al. Transcranial Direct Current Stimulation and Cerebral Vasomotor Reserve: A Study in Healthy Subjects. J Neuroimaging 25, 571–574 (2015).
Stagg, C. J. et al. Widespread modulation of cerebral perfusion induced during and after transcranial direct current stimulation applied to the left dorsolateral prefrontal cortex. J Neurosci 33, 11425–11431 (2013).
Wang, Y. et al. Direct current stimulation over the human sensorimotor cortex modulates the brain’s hemodynamic response to tactile stimulation. Eur J Neurosci 42, 1933–1940 (2015).
Mielke, D. et al. Cathodal transcranial direct current stimulation induces regional, long-lasting reductions of cortical blood flow in rats. Neurol Res 35, 1029–1037 (2013).
Guarienti, F. et al. Reducing transcranial direct current stimulation-induced erythema with skin pretreatment: considerations for sham-controlled clinical trials. Neuromodulation 18, 261–265 (2015).
Minhas, P. et al. Electrodes for high-definition transcutaneous DC stimulation for applications in drug delivery and electrotherapy, including tDCS. J Neurosci Methods 190, 188–197 (2010).
Zhao, M., Bai, H., Wang, E., Forrester, J. V. & McCaig, C. D. Electrical stimulation directly induces pre-angiogenic responses in vascular endothelial cells by signaling through VEGF receptors. J Cell Sci 117, 397–405 (2004).
Bai, H., McCaig, C. D., Forrester, J. V. & Zhao, M. DC electric fields induce distinct preangiogenic responses in microvascular and macrovascular cells. Arterioscler Thromb Vasc Biol 24, 1234–1239 (2004).
Grodzinsky, A. J. & Frank, E. H. Fields, forces, and flows in biological systems. (Garland Science, 2011).
Li, G. & Fu, B. M. An electrodiffusion model for the blood-brain barrier permeability to charged molecules. J Biomech Eng 133, 021002 (2011).
Sanchez, J. M. et al. Evidence for a central role for electro-osmosis in fluid transport by corneal endothelium. J Membr Biol 187, 37–50 (2002).
Cancel, L. M., Fitting, A. & Tarbell, J. M. In vitro study of LDL transport under pressurized (convective) conditions. Am J Physiol-Heart C 293, H126–H132 (2007).
DeMaio, L., Tarbell, J. M., Scaduto, R. C. Jr, Gardner, T. W. & Antonetti, D. A. A transmural pressure gradient induces mechanical and biological adaptive responses in endothelial cells. Am J Physiol Heart Circ Physiol 286, H731–741 (2004).
Sill, H. W. et al. Shear stress increases hydraulic conductivity of cultured endothelial monolayers. Am J Physiol 268, H535–543 (1995).
Fu, B. M., Weinbaum, S., Tsay, R. Y. & Curry, F. E. A junction-orifice-fiber entrance layer model for capillary permeability: application to frog mesenteric capillaries. J Biomech Eng 116, 502–513 (1994).
Li, G. L. et al. Permeability of Endothelial and Astrocyte Cocultures: In Vitro Blood-Brain Barrier Models for Drug Delivery Studies. Ann Biomed Eng 38, 2499–2511 (2010).
Miyake, M. & Kurihara, K. Resting potential of the mouse neuroblastoma cells. II. Significant contribution of the surface potential to the resting potential of the cells under physiological conditions. Biochim Biophys Acta 762, 256–264 (1983).
Guy, Y., Sandberg, M. & Weber, S. G. Determination of zeta-potential in rat organotypic hippocampal cultures. Biophys J 94, 4561–4569 (2008).
Nitsche, M. A. & Paulus, W. Excitability changes induced in the human motor cortex by weak transcranial direct current stimulation. J Physiol 527(Pt 3), 633–639 (2000).
Bikson, M. et al. Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016. Brain Stimul 9, 641–661 (2016).
Huang, Y. et al. Measurements and models of electric fields in the in vivo human brain during transcranial electric stimulation. Elife 6 (2017).
Srinivasan, B. et al. TEER measurement techniques for in vitro barrier model systems. J Lab Autom 20, 107–126 (2015).
Datta, A., Elwassif, M., Battaglia, F. & Bikson, M. Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis. J Neural Eng 5, 163–174 (2008).
Batsikadze, G., Moliadze, V., Paulus, W., Kuo, M. F. & Nitsche, M. A. Partially non-linear stimulation intensity-dependent effects of direct current stimulation on motor cortex excitability in humans. J Physiol 591, 1987–2000 (2013).
Esmaeilpour, Z. et al. Incomplete evidence that increasing current intensity of tDCS boosts outcomes. Brain Stimul 11, 310–321 (2018).
Jamil, A. et al. Systematic evaluation of the impact of stimulation intensity on neuroplastic after-effects induced by transcranial direct current stimulation. J Physiol 595, 1273–1288 (2017).
Cipolla, M. J. In The Cerebral Circulation Ch. 2, Anatomy and Ultrastructure (Morgan & Claypool Life Sciences, 2009).
Butt, A. M., Jones, H. C. & Abbott, N. J. Electrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study. J Physiol 429, 47–62 (1990).
Hladky, S. B. & Barrand, M. A. Mechanisms of fluid movement into, through and out of the brain: evaluation of the evidence. Fluids Barriers CNS 11, 26 (2014).
Xie, L. et al. Sleep drives metabolite clearance from the adult brain. Science 342, 373–377 (2013).
Shi, Z. D. & Tarbell, J. M. Fluid flow mechanotransduction in vascular smooth muscle cells and fibroblasts. Ann Biomed Eng 39, 1608–1619 (2011).
Qazi, H., Palomino, R., Shi, Z. D., Munn, L. L. & Tarbell, J. M. Cancer cell glycocalyx mediates mechanotransduction and flow-regulated invasion. Integr Biol (Camb) 5, 1334–1343 (2013).
Shi, S., Luke, C. J., Miedel, M. T., Silverman, G. A. & Kleyman, T. R. Activation of the Caenorhabditis elegans Degenerin Channel by Shear Stress Requires the MEC-10 Subunit. J Biol Chem 291, 14012–14022 (2016).
Maneshi, M. M., Sachs, F. & Hua, S. Z. A Threshold Shear Force for Calcium Influx in an Astrocyte Model of Traumatic Brain Injury. J Neurotrauma 32, 1020–1029 (2015).
Chien, S., Li, S. & Shyy, Y. J. Effects of mechanical forces on signal transduction and gene expression in endothelial cells. Hypertension 31, 162–169 (1998).
Topper, J. N. & Gimbrone, M. A. Jr. Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype. Mol Med Today 5, 40–46 (1999).
Uematsu, M. et al. Regulation of endothelial cell nitric oxide synthase mRNA expression by shear stress. Am J Physiol 269, C1371–1378 (1995).
Ebong, E. E., Lopez-Quintero, S. V., Rizzo, V., Spray, D. C. & Tarbell, J. M. Shear-induced endothelial NOS activation and remodeling via heparan sulfate, glypican-1, and syndecan-1. Integr Biol (Camb) 6, 338–347 (2014).
Kuchan, M. J. & Frangos, J. A. Role of calcium and calmodulin in flow-induced nitric oxide production in endothelial cells. Am J Physiol 266, C628–636 (1994).
O’Neill, W. C. Flow-mediated NO release from endothelial cells is independent of K+ channel activation or intracellular Ca2+. Am J Physiol 269, C863–869 (1995).
Tarbell, J. M., Demaio, L. & Zaw, M. M. Effect of pressure on hydraulic conductivity of endothelial monolayers: role of endothelial cleft shear stress. J Appl Physiol (1985) 87, 261–268 (1999).
Abbott, N. J., Patabendige, A. A., Dolman, D. E., Yusof, S. R. & Begley, D. J. Structure and function of the blood-brain barrier. Neurobiol Dis 37, 13–25 (2010).
Abbott, N. J., Rönnbäck, L. & Hansson, E. Astrocyte–endothelial interactions at the blood–brain barrier. Nature Reviews Neuroscience 7, 41 (2006).
Koehler, R. C., Roman, R. J. & Harder, D. R. Astrocytes and the regulation of cerebral blood flow. Trends in Neurosciences 32, 160–169 (2009).
Persidsky, Y., Ramirez, S. H., Haorah, J. & Kanmogne, G. D. Blood–brain Barrier: Structural Components and Function Under Physiologic and Pathologic Conditions. Journal of Neuroimmune Pharmacology 1, 223–236 (2006).
Serlin, Y., Shelef, I., Knyazer, B. & Friedman, A. Anatomy and physiology of the blood-brain barrier. Semin Cell Dev Biol 38, 2–6 (2015).
Wolburg, H., Noell, S., Mack, A., Wolburg-Buchholz, K. & Fallier-Becker, P. Brain endothelial cells and the glio-vascular complex. Cell and Tissue Research 335, 75–96 (2009).
Antonenko, D. et al. tDCS-Induced Modulation of GABA Levels and Resting-State Functional Connectivity in Older Adults. J Neurosci 37, 4065–4073 (2017).
Auvichayapat, P. et al. Transient Changes in Brain Metabolites after Transcranial Direct Current Stimulation in Spastic Cerebral Palsy: A Pilot Study. Front Neurol 8, 366 (2017).
Giovannella, M. et al. Concurrent measurement of cerebral hemodynamics and electroencephalography during transcranial direct current stimulation. Neurophotonics 5, 015001 (2018).
Jalali, R., Chowdhury, A., Wilson, M., Miall, R. C. & Galea, J. M. Neural changes associated with cerebellar tDCS studied using MR spectroscopy. Exp Brain Res 236, 997–1006 (2018).
Jindal, U. et al. Corticospinal excitability changes to anodal tDCS elucidated with NIRS-EEG joint-imaging: An ischemic stroke study. Conf Proc IEEE Eng Med Biol Soc 2015, 3399–3402 (2015).
Kim, S., Stephenson, M. C., Morris, P. G. & Jackson, S. R. tDCS-induced alterations in GABA concentration within primary motor cortex predict motor learning and motor memory: a 7 T magnetic resonance spectroscopy study. Neuroimage 99, 237–243 (2014).
Muthalib, M., Besson, P., Rothwell, J. & Perrey, S. Focal Hemodynamic Responses in the Stimulated Hemisphere During High-Definition Transcranial Direct Current Stimulation. Neuromodulation (2017).
Yan, J. et al. Use of functional near-infrared spectroscopy to evaluate the effects of anodal transcranial direct current stimulation on brain connectivity in motor-related cortex. J Biomed Opt 20, 46007 (2015).
Schulze, C. & Firth, J. A. Interendothelial junctions during blood-brain barrier development in the rat: morphological changes at the level of individual tight junctional contacts. Brain Res Dev Brain Res 69, 85–95 (1992).
Adamson, R. H. & Michel, C. C. Pathways through the intercellular clefts of frog mesenteric capillaries. J Physiol 466, 303–327 (1993).
Wang, C., Lu, H. & Schwartz, M. A. A novel in vitro flow system for changing flow direction on endothelial cells. J Biomech 45, 1212–1218 (2012).
Lang, Q. et al. AC Electrothermal Circulatory Pumping Chip for Cell Culture. ACS Appl Mater Interfaces 7, 26792–26801 (2015).
Acknowledgements
This research was supported by NIH grant EB017510.
Author information
Authors and Affiliations
Contributions
L.M.C., M.B. and J.M.T. designed the study. L.M.C. and K.A. acquired and analyzed the data. L.M.C. wrote the main manuscript text. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing Interests
L.M.C., K.A. and J.M.T declare no competing interests. M.B. has significant interest in Soterix Medical Inc. which commercializes hardware and software for transcranial electrical stimulation (TES). He is listed as inventor on patents (U.S. Patent application No.13/264,142) related to TES.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Cancel, L.M., Arias, K., Bikson, M. et al. Direct current stimulation of endothelial monolayers induces a transient and reversible increase in transport due to the electroosmotic effect. Sci Rep 8, 9265 (2018). https://doi.org/10.1038/s41598-018-27524-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-27524-9
- Springer Nature Limited
This article is cited by
-
Cytoskeletal Remodeling and Gap Junction Translocation Mediates Blood–Brain Barrier Disruption by Non-invasive Low-Voltage Pulsed Electric Fields
Annals of Biomedical Engineering (2024)
-
Breaking barriers: exploring mechanisms behind opening the blood–brain barrier
Fluids and Barriers of the CNS (2023)
-
Is blood-brain barrier a probable mediator of non-invasive brain stimulation effects on Alzheimer’s disease?
Communications Biology (2023)
-
Direct current stimulation modulates gene expression in isolated astrocytes with implications for glia-mediated plasticity
Scientific Reports (2022)
-
Group and individual level variations between symmetric and asymmetric DLPFC montages for tDCS over large scale brain network nodes
Scientific Reports (2021)