Abstract
Stem cell products, including manufactured red blood cells, require efficient sorting and purification methods to remove components potentially harmful for clinical application. However, standard approaches for cellular downstream processing rely on the use of specific and expensive labels (e.g. FACS or MACS). Techniques relying on inherent mechanical and physical properties of cells offer high-throughput scalable alternatives but knowledge of the mechanical phenotype is required. Here, we characterized for the first time deformability and size changes in CD34+ cells, and expelled nuclei, during their differentiation process into red blood cells at days 11, 14, 18 and 21, using Real-Time Deformability Cytometry (RT-DC) and Atomic Force Microscopy (AFM). We found significant differences (p < 0.0001; standardised mixed model) between the deformability of nucleated and enucleated cells, while they remain within the same size range. Expelled nuclei are smaller thus could be removed by size-based separation. An average Young’s elastic modulus was measured for nucleated cells, enucleated cells and nuclei (day 14) of 1.04 ± 0.47 kPa, 0.53 ± 0.12 kPa and 7.06 ± 4.07 kPa respectively. Our identification and quantification of significant differences (p < 0.0001; ANOVA) in CD34+ cells mechanical properties throughout the differentiation process could enable development of new routes for purification of manufactured red blood cells.
Similar content being viewed by others
Introduction
Annually, around 112.5 million blood donations are collected across 176 countries in over 13000 blood centres1. However, each year the World Health Organisation reports a shortage of safe donated blood for transfusion, mostly due to a decreasing number of people eligible to donate blood and technical limitations for blood long-term storage2. There is consequently an urgent need for easily manageable alternative sources of red blood cells (RBCs), one option being their manufacture from stem cells3,4,5,6. Manufactured red blood cells (mRBCs) have been positively validated as a potential clinical product in 2011 by Giarratana et al.7, with potentially transfusable RBCs already produced in vitro using embryonic stem cells5, induced pluripotent stem cells8, CD34+ cells sourced from bone marrow4 or umbilical cord blood9, and recently an immortalized adult human erythroid line (Bristol Erythroid Line Adult BEL-A)10. However, the differentiation protocols currently used are not 100% efficient. Specifically, the end-product of the protocol is a heterogeneous cell mixture containing not only fully functional enucleated mRBCs, but also free-floating nuclei expelled during enucleation and undifferentiated nucleated cells. The presence of residual stem cells, partially differentiated cells and nuclei, pose a health risk if injected into patients11 and is consequently a serious concern that must be alleviated for mRBCs and other cellular therapies by developing adequate purification procedures12,13,14,15,16,17. Traditionally, target cell separation is performed by Fluorescent Activated Cell Sorting (FACS) and Magnetic Activated Cell Sorting (MACS). Both techniques are very specific since they utilize molecular biomarkers but require the addition of costly modifying agents, such as antibodies or DNA stains, and separate quality-control processes18,19. Furthermore, the throughput of these techniques is limited (e.g. 107 cells/ hour for the FACS instrument used in this research) and industrially viable technologies require cost-effective, automated and scalable approaches20. Various label-free approaches have been proposed in the literature, though have not yet reached the stage of commercial testing: acoustophoresis21, magnetophoresis22, optical methods23 and passive sorting24. Passive sorting (such as inertial focusing25, pinch flow fractionation26, deterministic lateral displacement27 and filtration28) exploits properties of the device design and, except for a liquid pumping system, they do not require any other external forces. These systems present many potential advantages such as a reduced number of sample processing steps (e.g. by reducing staining/washing steps), relatively high-throughput (millilitres/min29 and litres/min30) and efficiency (>90%)31,32,33. However, sorting in this type of system is facilitated purely by endogenous cell properties such as size and deformability and further evidence is needed to quantify the cell mechanotype, to overcome the existing lack of knowledge on e.g. mRBCs mechanical properties34, and determine the potential for mechanotype based sorting.. Deformability is emerging as a novel homogeneity marker that could serve to identify subpopulations within complex cell samples such as mRBCs35. However, while qualitative observations have noted changes in phenotype throughout the differentiation protocol of CD34+ cells, little is known about their mechanical phenotype changes. This article reports on the first extensive quantitative analysis of these changes, combining both high-throughput microfluidics as well as traditional biophysical characterisation. Specifically, we characterised for the first time the mechanotype of cord blood CD34+ undergoing in vitro differentiation into RBCs, focusing on four key stages. Data was collected determining the size and deformability of enucleated cells, nucleated cells and free-floating nuclei using real-time deformability cytometry (RT-DC), atomic force microscopy (AFM), and bright field/fluorescent imaging. Furthermore, staining of the nucleus and cytoskeletal proteins was undertaken to investigate the potential contribution of these factors to the observed mechanotypical changes.
Results and Discussion
The in vitro manufacture of RBCs from hematopoietic stem cells (CD34+) follows an in vitro protocol which is a recapitulation of in vivo erythropoiesis through distinct developmental stages36,37 (for details of the protocol and the different stages involved consult Fig. S1). Initially, the culture is expanded for the first ten days (D0 to D10) before differentiation is induced at D11, resulting in drastic cell phenotype changes during the final 11 days of differentiation. Observed changes are induced stage-wise, by adjusting cell culture medium components. The presence of biological markers at different points in the differentiation has been studied8,9,38, underpinning the label-based separation approaches, and it is known that between D0 and D11, CD34+ cells extensively proliferate without changing their identity. Around D14 cells start producing haemoglobin and reduce their intracellular structures (the cytoplasm becomes simplified) and size. By D18, chromatin becomes compacted, cellular division slows and in the final stages, the nucleus is expelled. Based upon this, four distinct time points (at D11, D14, D18 and D21) were selected to assess the changing mechanotype of CD34+ during in vitro erythropoiesis to determine the potential for mechanical properties to act as a homogeneity marker upon which passive cell separation methods can be developed.
High-throughput size and deformability assessment
While there are many available well-established technologies for assessing cell mechanotype such as Atomic Force Microscopy (AFM)39, micropipette aspiration40, magnetic tweezers and optical stretchers41, these methods suffer from low-throughput42. To assess a high number of cells (thousands of events per minute), we used a microfluidic-based Real-Time Deformability Cytometer (RT-DC)43. RT-DC is a contactless technique, allowing gain of thousands of events per minute, which is convenient for the global characterisation of complex samples44. For comparison of technologies for cell mechanotype assessment see Table S1.1. In the RT-DC set-up, shear stress is generated by a viscous liquid flowing through a channel of defined dimensions to induce cell deformation, which is defined as cell circularity45 and is given by:
where \(A\) is the projected cell surface area and \(\,l\) is the cell perimeter. For perfectly circular objects \(c=1\) and a deformable object will be characterised by \(c < 1\).
CD34+ cells size and deformability at D11, D14, D18 and D21 were assessed using RT-DC for both individual and mixed populations of nucleated and enucleated cells as well as expelled nuclei. Free-floating nuclei and undifferentiated cells constitute the two main contaminants that must be removed from the sample, prior to clinical application, to leave purified mRBCs. A global view of mechanical changes using mixed populations, directly from the cell culture, is presented in Fig. 1a, plotting deformation against cell area. The results indicate that as the differentiation process progresses, deformability increases while size decreases and the emergence of a greater number of different cell populations can be observed. At D11 cells are strongly heterogeneous in size (cell areas ranging between 25 and 175 µm2) while deformability is low (<0.2). At D14 the first spontaneous enucleation events are observed characterized by a new emerging subpopulation on the deformation axis (events with deformation >0.2) and the reduction in cell size very few cell areas above 100 µm2). Closer to the end of the differentiation process (D18 and D21), the enucleated cell subpopulation becomes dominant (deformability >0.25) and another population corresponding to expelled nuclei appears (deformability < 0.03). In in vivo differentiation, nuclei would be removed by macrophages46,47.
Utilising the above data, we compared the size and deformability of enucleated and nucleated cells and nuclei at each of the time points. Firstly, we confirmed the identity of the three subpopulations by collecting data from a mixed sample as well as from samples which were sorted into pure populations by FACS and assessed using the RT-DC separately (Fig. S2). Regions corresponding to each subpopulation were therefore identified and used for analysis (using the polygon tool in the ShapeOut software) (Fig. S2).
The populations identified from the mixed sample (Fig. S2a) correspond to the individual gated enucleated (Fig. S2d) and nucleated (Fig. S2e) cells and nuclei (Fig. S2c) populations. In general, the individual populations of cells are slightly stiffer than those from the mixed population, due to the extra processing undertaken48.However, Fig. S2b shows that the three different subpopulations plot in different regions suggesting that there is potential to utilise size and deformability changes as a basis for separation and sorting. Secondly, to confirm that software could utilise size and deformability differences to classify cells, events from the scatter plot of a mixed sample were analysed using a Gaussian mixture model also identifying three subpopulations (Fig. 1b), as expected from the previous gating analysis (Fig. S2).
To further analyse the data, box plots were generated showing the average and range of the size and deformability characteristics for each of the subpopulations. Figure 1c illustrates the size variation of the three populations at the selected time points (D11 only appears for nucleated cells as this is before the enucleation step). Nuclei are much smaller (with area 22.8 ± 3.8 µm2, mean ± SD) than the nucleated cells (D11 72.9 ± 25.8, D14 71.6 ± 12.8, D18 54.7 ± 7.2 and D21 52. 2 ± 7.5 µm2) and enucleated cells (D14 57.6 ± 8.6, D18 50.9 ± 9 and D21 47.9 ± 7.5 µm2) with little size overlap (p < 0.0001). In terms of the size of cells, there is a statistically significant difference between enucleated and nucleated cells (p < 0.0001). However, there is an overlap between events from both subpopulations (Fig. 1c).
Figure 1 d considers the deformability differences between the three populations and demonstrates greater discrimination potential. Nuclei deformability is 0.03 ± 0.01 whereas that of nucleated cells is greater than 0.1 (D14 0.13 ± 0.04, D18 0.18 ± 0.05 and D21 0.12 ± 0.05) and enucleated cells greater than 0.25 (D14 0.26 ± 0.05, D18 0.34 ± 0.05 and D21 0.33 ± 0.05) and the difference is statistically significant (p < 0.0001). Additionally, a significant difference in deformability (p < 0.0001) is observed for nucleated (deformability 0.1–0.25) and enucleated (deformability >0.25) cells.
To quantify the degree of the size and deformability overlap, receiver operating characteristic (ROC) curves were plotted and the corresponding area under the curve (AUC) calculated (Fig. S2). Using this approach we determined that enucleated cells are 100% separated (AUC = 1) from the nuclei population in terms of size (Fig. S3b) and deformability (Fig. S3d). Microfluidic systems have been designed to separate particles in the same range of sizes (diameter) as nuclei (6 µm) and enucleated cells (7–10 µm)24,49 and the data supports the potential for a size-based separation as a route for nuclei removal. Figure S3a shows that within a population classified in terms of size as enucleated cells, 17% of those cells belong to the nucleated cell population (AUC = 0.83). Therefore size-based separation between nucleated and enucleated cells would be possible but would result in a significant contamination. The deformability difference between enucleated and nucleated cells (Fig. S3c) is close to 100% (AUC = 0.99) suggesting the feasibility of deformability to separate these populations.
Young’s modulus measurements for enucleated and nucleated cells and nuclei with AFM
AFM is the current gold standard for the biomechanical characterisation of cells. AFM imaging was employed to confirm the size based analysis. Furthermore, AFM force-distance curves were utilised to analyse the differences observed by RT-DC in deformability and convert from the circularity measure of deformability to elastic modulus, which is a useful measure for the design of separation systems.
Using AFM Quantitative Imaging (QI) mode and a sharp conical tip, the elastic properties of 60 D14 cells from a mixed culture were measured along with individual populations, isolated by FACS, of 25 nucleated and 25 enucleated cells and 60 nuclei (Fig. 2). As discussed in previous work, AFM elastic measurements are position-dependant50,51 which means based on the location indented on the cell, derived elastic modulus can be different from another location on the same cell. These changes in the elastic modulus across the cell are due to the presence/absence of a nucleus and other organelles. Therefore, 64 measurements were taken at different locations of each cell to obtain elasticity changes over the cell, and the derived Young’s elastic modulus was averaged (Fig. 2a). To determine the elastic modulus, calculations were based on the Hertz-Sneddon contact model utilising all derived results from different locations on each cell and all cells in each group (mixed, enucleated and nucleated cells, and nuclei). To study the difference in the elastic modulus of the subpopulations, each range of the elastic modulus was plotted against the probability of each elastic modulus [E] (Fig. 2a). Probability can be defined as the number of occurrences of a targeted elastic modulus divided by the number of occurrences plus the number of failures of occurrences (total possible outcomes) and it is calculated from:
The average Young’s elastic modulus for the mixed cells, nucleated and enucleated cells, and nuclei were derived as: 0.91 ± 0.52 kPa (n = 60), 1.04 ± 0.47 kPa, and 0.53 ± 0.12 kPa (both n = 25), and 7.06 ± 4.07 kPa (n = 60) respectively (cf. Figure 2b for boxplot summarizing the average and range with the underlying data included in Tables S2 and S3). The elastic modulus of RBCs was reported in the literature as (0.143 ± 0.059 kPa), using spherical indenter52. As expected the elasticity of enucleated cells is consequently the closest to the elasticity of RBCs, although still somewhat higher. However, it needs to be mentioned that most cell studies use spherical indenters, which can give a lower elastic modulus when compared directly to a conical tip. It can be noted that biological changes, including a gradual decrease in the number of organelles, continue after the enucleation process resulting in further softening of the cells53.
This data is in accordance with the RT-DC data, showing that the enucleated cells are the most deformable whereas the nuclei are stiffest. Furthermore, as also shown by AFM, there is a significant difference between the derived Young’s elastic modulus of nucleated cells and nuclei (p < 0.0001), enucleated cells and nuclei (p < 0.0001, AUC = ) and nucleated and enucleated cells (p < 0.001), (Fig. 2b). Thus, the AFM data confirms the RT-DC finding that deformability is a potential homogeneity marker for downstream sample processing and quantifies the elastic modulus difference by creating ROC curves and calculating the AUC = 0.94 (Fig. S4) for nucleated and enucleated cells. Existing separation techniques based upon deformability enables the sorting of cells using differences in their Young’s elastic modulus. For instance it has been demonstrated that for a mixed cell culture media, a mixture of four cells, MDA MB 231, HL60, MCF 7 and HeLa, with Young’s elastic modulus of 1 kPa, 2.7kPa, 3.4 kPa and 13.5 kPa could be sorted using the stiffness-based sorting microfluidic channel with an efficiency ranging from 70 to 85%54.
AFM images from individual populations of nucleated cells, enucleated cells and nuclei were utilised to study the morphological differences among subpopulations. As also demonstrated by the RT-DC data, nuclei were observed to be smaller both in height and width in comparison to the other two subpopulations (Fig. S5a). Comparing enucleated and nucleated cells (Fig. S5b and c) the nucleated cells are slightly higher and narrower than the enucleated cells since on the poly-D-lysine coated petri dish the enucleated cells spread out more.
Correlation between mechanotype and biology
Cell deformability is determined by the structural components of the cell, particularly the cytoskeleton55. The cytoskeleton is a protein network (mostly actin and spectrin in RBCs56) supporting the cell structure and providing mechanical integrity to the cells. This network underlies the cell membrane and connects with the nucleus by extending through the cytoplasm and plays a crucial role in the enucleation, which is a dynamic process lasting approximately 10 min57. During the process, F-actin and myosin filaments undergo re-arrangements to facilitate the act of enucleation. Paraformaldehyde fixed cell samples were stained at D11, D14, D18 and D21 for F-actin (Fig. 3a), one of the most abundant cytoskeletal protein, and imaged. At D11 and D14 F-actin assembles into a uniform shell surrounding the cell interior. By the end of the differentiation protocol, at D18 and D21, the shell becomes thinner and less visible with small aggregates visible, which support the observed softening of nucleated cells between those days. Observed thinning is in agreement with literature evidence, where cytoskeletal protein levels were quantified by Western Blot36. It was reported that actin is downregulated during erythropoiesis with α-spectrin and β-spectrin expressed in higher quantities. Together, those rearrangements are believed to be an adaptation of RBCs to change their shape under the applied shear stress they experience during the vascular circulation, without haemolysis. When the lack of a nucleus is the main feature providing optimal cell deformability for oxygen transfer in tissues58. The presence of a nucleus, its changing characteristics and eventual expulsion throughout differentiation could contribute substantially to the overall cell mechanical behaviour59.
The contribution of the nucleus to the mechanotype is determined by its relative size60. To assess the nucleus/whole cell ratio, cytospin cell slides prepared at D11, D14, D18 and D21 were stained with rapid Romanowsky stain and visualised using a bright field microscope (Fig. 3b). Approximately 1000 events per condition were analysed and results are presented in Fig. 3c. Nuclei become smaller over time and at D11, on average, they constitute around 60% of the cell. The cytoplasm becomes simplified at later days and the nucleus is more compacted and smaller (50% for D14 and 40% for D18). We further explored the contribution of nuclei to the mechanical behaviour of cells by looking at cell elongation within the RT-DC microfluidic device under shear stress (Fig. 4a and b). In the RT-DC system, cells first pass through a reservoir section to then be forced through a smaller channel where a sheath flow induces a shear stress on the cells (Fig. S6). As presented in Fig. 4, the y-axis for enucleated and nucleated cells is larger than nuclei in the reservoir. When cells enter the main channel, the nuclei y-axis remains unchanged while the enucleated y-axis is shortened and the nucleated y-axis remains above the length of the nucleus. The presence of the nucleus seems therefore to constitute a barrier to the capability of a cell to deform under shear stress. To verify if it would be possible to separate enucleated and nucleated cells based on the degree of deformation they undergo under hydrodynamic stress, the length of the y-axis of enucleated and nucleated was compared. The measurement was obtained in the reservoir section of the device where cells experience shear stress and by creating a ROC curve and calculating the AUC = 1 (Fig. S7) we see that there is no overlap in the y-axis length. Deformability and size are coupled and the cell size revealed by their original shape change under applied stress could constitute a basis for cell separation (e.g. by passing through a filter with a cut-off size smaller than the length of y-axis for nucleated cells).
Conclusion and Outlook
Regenerative medicine, and cell therapy, in particular, are seen as a potential route to revolutionize medicine and to improve healthcare for patients who currently have either limited or no treatment options. The in vitro produced RBCs are seen to address needs in transfusion medicine.
For the wide-spread adoption of mRBCs, and indeed other cell therapies, challenges related to cell source, maturation and viability need to be addressed by biologists, while advancements in cell processing technologies will be required to manufacture those cells in meaningful quantities and achieve satisfactory purity. Label-free separation techniques based on mechanical phenotype differences offer a promising route to large-scale purification. However, to design optimal downstream processing protocols we first need to understand the mechanical characteristics of subpopulations within the samples, how these relate to molecular and architectural changes and how those changes evolve with cell-state and progressing differentiation protocols. Thus, here we characterised the mechanical properties (size and deformability) of CD34+ cells from cord blood as they undergo in vitro erythropoiesis. Cell size and deformability are highly dynamic features, significantly changing during the differentiation process. Based on our observations, using both novel high-throughput techniques (RT-DC) and AFM, cells become smaller and softer between D11 and D18 as different cell subpopulations emerge. Our staining results, linked with data from the literature, suggest that this phenomenon is driven by changes in the nucleus properties, which is expelled towards the end of the protocol, coupled to morphological changes in the cytoplasm and cytoskeleton.
Several key findings emerged from our mechanotype analysis. Firstly, there is no overlap between the sizes of the nuclei and the cells (both enucleated and nucleated). Data confirmed a 100% separation for both size and deformability. It could, therefore, be possible to design label-free systems to remove the nuclei exploiting the 2 µm difference in the average diameter of the cells and the nuclei at D18, a size at which there is plenty of evidence in the literature for successful separation approaches targeting different applications49.
Secondly, since the data showed a significant overlap of the enucleated/nucleated cell populations in terms of size, the cell mechanotype marker of size might thus not be practical. Thirdly, we demonstrated a significant difference in deformability (from ROC curves AUC = 99%) and more specifically in Young’s elastic modulus (0.51 kPa difference on average at the end of the protocol) between the enucleated/nucleated cell populations. In order to purify enucleated cell from nucleated cells, methods which exploit either, or both of, the observed differences in cells Young’s elastic modulus and deformation under shear stress could be utilised.
Overall, our data provide the first quantitative information regarding the mechanotype of CD34+ cells undergoing differentiation into manufactured RBCs, which could assist in the design of robust label-free purification approaches.
Materials and Methods
Sample Preparation
Cord CD34+ Stem Cell Culture
All methods were carried out in accordance with relevant guidelines and regulations and were approved by the Heriot-Watt Engineering and Physical Sciences Ethics Committee as well as the Heriot-Watt Engineering and Physical Sciences Biosafety Review. The cells used in this work were commercially obtained from donated cord blood and therefore consented to the research use. The CD34+ hematopoietic stem cells were primarily purchased from Stem Cell Technologies, expanded and cryopreserved after 6 days in culture using a variation of the method previously described61. A master cell bank from one healthy donor was created with D6 cells cryopreserved in fresh medium supplemented with 30% Knockout Serum Replacement and 10% DMSO. Cells at day 6 were resuscitated, washed and re-cultured in fresh pre-warmed growth medium: Iscove’s basal medium (VWR, cat. BCHRFG0465), 5% human AB+ Serum (Sigma Aldrich, cat. H4522), 3 U/ml heparin (Sigma Aldrich, cat. H5515), 10 µg/ml insulin (Sigma Aldrich, cat. 19278) and 200 µg/ml human holotransferrin (VWR, cat. 616397-500) supplemented with 60 ng/ml recombinant human stem cell factor (SCF) (PeproTech, cat. 300-07), 5 ng/ml recombinant human IL-3 (PeproTech, cat. 200-03), 3 U/ml erythropoietin (EPO) (clinical grade material, Roche) and 1 µM hydrocortisone (Sigma Aldrich, cat. H0888) until day 8. At day 8 cell culture medium was replaced with fresh ISHIT cell culture medium supplemented with 10 ng/ml SCF, 3U/ml Erythropoietin, 1 µM Hydrocortisone and 300 µg/ml Transferrin and cultured until day 14. At day 14, a cell count was performed using the trypan blue exclusion technique, cells centrifuged at 300 g for 5 min and re-seeded in fresh culture medium containing 3 U/ml erythropoietin and 300 µg/ml holotransferrin. After a further four days of culture (day 18) cells were re-seeded in fresh medium (the same composition as day 14). Each time cells were harvested, they were transferred into a centrifuge tube (Corning, UK) and centrifuged at 300 g for 5 min. All cell culture manipulations were carried under aseptic conditions in a cabinet with a laminar air flow.
Flow Cytometry
Cells were assayed for expression of CD235a (Glycophorin A) and for the presence of a nucleus using flow cytometry during differentiation. At each control time point: day 11, 14, 18 and 21 (D11, D14, D18 and D21), cells were collected and counted, centrifuged at 300 g for 5 min and re-suspended in basal medium supplemented with 0.5% BSA at a concentration of 1 × 107 cells/ml. To each 100 µl aliquot of cells, 0.625 µl of FITC-conjugated Mouse Anti-Human CD235a (BD, cat. 559943) and 0.5 µl of 5 mM DRAQ5™ Fluorescent Probe (BD, cat. 564902) was added to obtain a final concentration of 5 µM. Cells were incubated for at least 30 min at room temperature in darkness. The excess fluorescent stain was not removed to prevent cell damage. Cells were analysed on a BD FACSCalibur within two hours of staining and raw data analysed using FlowJo V10 CL. The same staining strategy was used for cell sorting by FACS (FACSAria IIu flow cytometer, Beckton Dickinson Immunocytometry Systems (BD, UK) running BD FACSDiva v6 Software.
Mechanotype Characterisation
Real-Time Deformability Cytometry
Cells size and deformability changes were assessed using a Real-Time Deformability Cytometer (RT-DC). Measurements were performed as described in Nat. Methods 201543. In our work, a PDMS chip with a 20 µm × 20 µm cross-section channel was used. Prior to measurements, cells were harvested by centrifugation at 300 g for 5 min and resuspended in a 0.05% methylcellulose solution at 1–2 × 106 cells/ml. Cells were pumped into the channel at 0.12 µl/min. RT-DC data were analysed using original RT-DC software ShapeOut 0.6.9 (available at www.zellmechanik.com). Using the polygon tool built in the software, area and deformability values were obtained separately for day 11, 14, 18 and 21 as well as for separate subpopulations (enucleated cells, nucleated cells and nuclei). Data were then extracted from the software and further analysed using MatLab R2016b and GraphPad Prism 7. The significance of the results was calculated using a standardized mixed model that assumes non-normal distribution with three replicas of each experiment (Fig. S8). The receiver operating characteristic curves were generated and the area under the curve was calculated using a customised MatLab script (MatLab R2016b).
Atomic Force Microscopy (AFM) -Cell preparation
To prepare cells for AFM measurements, a concentration of 2 × 106 cells/ml was seeded onto poly-D-lysine hydrobromide (Sigma Aldrich cat. P6407, UK) coated AFM petri dishes. The dishes were then incubated for 1 minute to allow for adequate cellular attachment. Cell seeded sample dishes were then gently rinsed with 1 ml of Hank’s Balanced Salt Solution (HBSS, pH = 7) (Merk Millipore cat. H9394, UK) to remove any loosely and/or unattached cells. 2 ml of HBSS was then added to the sample dish, which was then mounted onto the BioCell™ stage, which maintains the cell sample and HBSS media at 37 °C for the duration of the AFM experiment52. The same protocol was applied for nucleus preparation.
AFM quantitative imaging mode
AFM measurements were carried out using the NanoWizard III Bio AFM (JPK Systems, Berlin, Germany), mounted on a Zeiss Observer D1 inverted optical microscope placed on top of a Halcyonics i4 anti-vibration table. For all experiments, silicon coated HQ: NSC36/Cr-Al series conical probe cantilevers, (MicroMasch, UK) half cone angle of 20° and tip radius of ~8 nm with spring constant of 0.01 N/m were used. In AFM measurements, obtained elastic modulus are highly dependent on the shape of the tip, indentation depth, cell preparation protocol and applied contact mechanical model. For instance, if comparing indenting a cell with a conical or a spherical shape indenter, the derived elastic modulus from the conical tip is higher than the one obtained from the spherical tip. This can be due to the fact that the conical tip provides more local elastic properties while the spherical tip presents the overall elastic properties62. The thermal noise method is used to determine the spring constant of the cantilever. Quantitative Imaging (QI) mode with the map size of 8 × 8 indexes is used to record force-distance curves from the whole area of each cell. For all experiments, the indentation speed was kept at 5 μm/sec, with the applied force in the range of 0.8–1 nN, depending on the differentiation date.
Elasticity analysis for AFM
Obtained force-distance curves were analysed for the elasticity measurements using the JPK data processing software version spm-5.0.69. Based on the map size of 8 × 8 indexes, 64 force-indentation curves per cell were recorded. The curves, which were from the AFM dish coating and/or residues within the culture media were discarded from the analysis. Due to the shape of the chosen cantilever probes, the Hertz-Sneddon contact model (for the conical probe geometry) was applied to determine the elastic modulus of the cells for each force-displacement curve obtained63,64.
Where F is an applied force, E is Young’s elastic modulus, α is a half cone angle of the AFM tip, δ is the indentation depth and ν is the Poisson ratio.
For use of the Hertz-Sneddon contact model to derive the Young’s elastic modulus of the cells, cells were assumed to be homogeneous, isotropic and semi-infinite bodies. Since the approach curves were not affected by the adhesion force, only the approach curves were used for the elasticity analysis. For each force curve, the baseline correction was carried out by calculating the average value of the baseline and subtracting it from the whole curve. The Hertz-Sneddon contact model was fitted approximately from the point where the force curve starts increasing.
Biological Characterisation
Cell morphology- Cytospin
To visualise cells morphology and structure, cells were transferred onto microscope slides using a cytocentrifuge then fixed and stained using Giemsa-Wright staining (Rapid Romanowsky Stain Pack, TCS Bioscience, cat. SW167/500). Cells at selected time points (D11, D14, D18 and D21) were harvested by centrifugation at 300 g for 5 min and resuspended at 2 × 106 cells/ml in Dulbecco’s PBS−/−. 100 µl of cell suspension was transferred into a cytocentrifuge cell funnel and centrifuged at 450 rpm for 4 min in a cytocentrifuge (Cellspin I Tharmac, Germany) to transfer the cells onto the slide. Slides were then air-dried for 15 min, fixed and stained according to the manufacturer’s instructions. After staining, slides were air-dried then fixed with DePeX mounting medium (Sigma Aldrich, cat. 06522). Slides were photographed for further image analysis using an EOS 60D Canon camera (Canon, UK) mounted on an AXIO Scope.A1 Zeiss microscope (Zeiss, Germany) at ×100 magnification. Images were analysed in Matlab R2016b using a custom-made script.
Widefield Microscopy
To study the cytoskeletal changes in CD34+ cells undergoing in vitro erythropoiesis, cells at day 11, 14, 18 and 21 were fixed in 4% paraformaldehyde (PFA) (ThermoFisher Scientific, cat. 28906) and imaged using a widefield microscope Olympus IX-81 TIRF+ with a ×150 1.4 NA immersion oil lens and EMCCD camera (Hamamatsu, UK). First cells were stained for 30 min at room temperature (RT) against F-actin with Actin Creen 488 Ready Probes reagents (Life Technologies, cat. R37110) then cells were transferred onto poly-D-lysine hydrobromide (Sigma Aldrich, cat. P6407, UK) coated cover slips to attach. Two minutes before the end of the incubation time, Hoechst 33342 (Sigma Aldrich, cat. 14533) was added to a final 10ng/ml concentration. After 2 minutes the cover slip was gently washed with PBS−/− to unattached free-floating cells. Twenty stack images per differentiation day (D11, D14, D18 and D21) were collected. Obtained stack images were deconvoluted with the Huygens Professional software.
Data availability
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request
References
World Health Organisation, Blood safety and availability, http://www.who.int/en/ (2017).
Hess, J. R. Red blood cell hemolysis during blood bank storage: using national quality management data to answer basic scientific questions. Transfusion 49, 2599–2603, https://doi.org/10.1111/j.1537-2995.2009.02275.x (2009).
Lapillonne, H. et al. Red blood cell generation from human induced pluripotent stem cells: perspectives for transfusion medicine. Haematologica 95, 1651–1659, https://doi.org/10.3324/haematol.2010.023556 (2010).
Giarratana, M. C. et al. Ex vivo generation of fully mature human red blood cells from hematopoietic stem cells. Nature biotechnology 23, 69–74, https://doi.org/10.1038/nbt1047 (2005).
Lu, S. J. et al. Biologic properties and enucleation of red blood cells from human embryonic stem cells. Blood 112, 4475–4484, https://doi.org/10.1182/blood-2008-05-157198 (2008).
Lin, J. et al. High-throughput physical phenotyping of cell differentiation. Microsystems & Nanoengineering 3, 17013, https://doi.org/10.1038/micronano.2017.13 (2017).
Giarratana, M.-C. et al. Proof of principle for transfusion of in vitro–generated red blood cells. Blood 118, 5071–5079, https://doi.org/10.1182/blood-2011-06-362038 (2011).
Dias, J. et al. Generation of red blood cells from human induced pluripotent stem cells. Stem cells and development 20, 1639–1647, https://doi.org/10.1089/scd.2011.0078 (2011).
Fujimi, A. et al. Ex vivo large-scale generation of human red blood cells from cord blood CD34+ cells by co-culturing with macrophages. International journal of hematology 87, 339–350, https://doi.org/10.1007/s12185-008-0062-y (2008).
Trakarnsanga, K. et al. An immortalized adult human erythroid line facilitates sustainable and scalable generation of functional red cells.
Bouhassira, E. E. Toward the manufacture of red blood cells? Blood 112, 4362–4363, https://doi.org/10.1182/blood-2008-09-177212 (2008).
Rao, M. S. Funding translational work in cell-based therapy. Cell Stem Cell 9, 7–10, https://doi.org/10.1016/j.stem.2011.06.009 (2011).
Heathman, T. R. et al. The translation of cell-based therapies: clinical landscape and manufacturing challenges. Regenerative medicine 10, 49–64, https://doi.org/10.2217/rme.14.73 (2015).
Ahrlund-Richter, L. et al. Isolation and production of cells suitable for human therapy: challenges ahead. Cell Stem Cell 4, 20–26, https://doi.org/10.1016/j.stem.2008.11.012 (2009).
Preti, R. A. Bringing safe and effective cell therapies to the bedside. Nature biotechnology 23, 801–804, https://doi.org/10.1038/nbt0705-801 (2005).
Parson, A. The long journey from stem cells to medical product. Cell 125, 9–11, https://doi.org/10.1016/j.cell.2006.03.024 (2006).
Dodson, B. P. & Levine, A. D. Challenges in the translation and commercialization of cell therapies. BMC Biotechnology 15, 70, https://doi.org/10.1186/s12896-015-0190-4 (2015).
Isacson, O. Sorting the wheat from the chaff in dopamine neuron-based cell therapies. Proceedings of the National Academy of Sciences of the United States of America 112, 4512–4513, https://doi.org/10.1073/pnas.1503859112 (2015).
Almeida, M., García-Montero, A. C. & Orfao, A. Cell purification: a new challenge for biobanks. Pathobiology 81, 5–6, https://doi.org/10.1159/000358306 (2014).
Willoughby, N. A. et al. A scalable label-free approach to separate human pluripotent cells from differentiated derivatives. Biomicrofluidics 10, 014107, https://doi.org/10.1063/1.4939946 (2016).
Dykes, J., Lenshof, A., Astrand-Grundstrom, I. B., Laurell, T. & Scheding, S. Efficient removal of platelets from peripheral blood progenitor cell products using a novel micro-chip based acoustophoretic platform. PloS one 6, e23074, https://doi.org/10.1371/journal.pone.0023074 (2011).
Nicole Pamme, A. M. On-chip free-flow magnetophoresis continuous flow separation of magnetic particles and agglomerates. Analytical chemistry 76, 7250–7256, https://doi.org/10.1021/ac049183o (2004).
Chiou, P. Y., Ohta, A. T. & Wu, M. C. Massively parallel manipulation of single cells and microparticles using optical images. Nature 436, 370–372, https://doi.org/10.1038/nature03831 (2005).
Shields, C. Wt, Reyes, C. D. & Lopez, G. P. Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation. Lab on a chip 15, 1230–1249, https://doi.org/10.1039/c4lc01246a (2015).
Di Carlo, D., Irimia, D., Tompkins, R. G. & Toner, M. Continuous inertial focusing, ordering, and separation of particles in microchannels. Proceedings of the National Academy of Sciences of the United States of America 104, 18892–18897, https://doi.org/10.1073/pnas.0704958104 (2007).
Yamada, M., Nakashima, M. & Seki, M. Pinched flow fractionation: continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel. Anal Chem 76, 5465–5471, https://doi.org/10.1021/ac049863r (2004).
Huang, L. R., Cox, E. C., Austin, R. H. & Sturm, J. C. Continuous particle separation through deterministic lateral displacement. Science (New York, N.Y.) 304, 987–990, https://doi.org/10.1126/science.1094567 (2004).
Matsuda, M., Yamada, M. & Seki, M. Blood cell classification utilizing hydrodynamic filtration. Electronics and Communications in Japan 94, 1–6, https://doi.org/10.1002/ecj.10281 (2011).
Warkiani, M. E. et al. Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells. Lab Chip 14, 128–137, https://doi.org/10.1039/c3lc50617g (2014).
Miller, B., Jimenez, M. & Bridle, H. Cascading and parallelising curvilinear inertial focusing systems for high volume, wide size distribution, separation and concentration of particles. Scientific reports 6, 36386, https://doi.org/10.1038/srep36386 (2016).
Nathamgari, S. S. et al. Isolating single cells in a neurosphere assay using inertial microfluidics. Lab on a chip 15, 4591–5597, https://doi.org/10.1039/c5lc00805k (2015).
Wu, Z., Willing, B., Bjerketorp, J., Jansson, J. K. & Hjort, K. Soft inertial microfluidics for high throughput separation of bacteria from human blood cells. Lab on a Chip 9, 1193–1199 (2009).
Lee, G.-H., Kim, S.-H., Ahn, K., Lee, S.-H. & Park, J. Y. Separation and sorting of cells in microsystems using physical principles. Journal of Micromechanics and Microengineering 26, 013003 (2015).
Shah, S., Huang, X. & Cheng, L. Concise review: stem cell-based approaches to red blood cell production for transfusion. Stem cells translational medicine 3, 346–355, https://doi.org/10.5966/sctm.2013-0054 (2014).
Darling, E. M. & Di Carlo, D. High-Throughput Assessment of Cellular Mechanical Properties. Annual review of biomedical engineering 17, 35–62, https://doi.org/10.1146/annurev-bioeng-071114-040545 (2015).
Hu, J. et al. Isolation and functional characterization of human erythroblasts at distinct stages: implications for understanding of normal and disordered erythropoiesis in vivo. Blood 121, 3246–3253, https://doi.org/10.1182/blood-2013-01-476390 (2013).
Chen, K. et al. Resolving the distinct stages in erythroid differentiation based on dynamic changes in membrane protein expression during erythropoiesis. Proceedings of the National Academy of Sciences of the United States of America 106, 17413–17418, https://doi.org/10.1073/pnas.0909296106 (2009).
Huang, X. et al. Extensive ex vivo expansion of functional human erythroid precursors established from umbilical cord blood cells by defined factors. Molecular therapy: the journal of the American Society of Gene Therapy 22, 451–463, https://doi.org/10.1038/mt.2013.201 (2014).
Vahabi, S., Nazemi Salman, B. & Javanmard, A. Atomic force microscopy application in biological research: a review study. Iranian Journal of Medical Sciences 38, 76–83 (2013).
Mitchison, J. M. & Swann, M. M. The Mechanical Properties of the cell Surface. Journal of Experimental Biology 31, 461–472 (1954).
Ekpenyong, A. E. et al. Viscoelastic properties of differentiating blood cells are fate- and function-dependent. PloS one 7, e45237, https://doi.org/10.1371/journal.pone.0045237 (2012).
Musielak, M. Red blood cell-deformability measurement: review of techniques. Clinical hemorheology and microcirculation 42, 47–64, https://doi.org/10.3233/CH-2009-1187 (2009).
Otto, O. et al. Real-time deformability cytometry: on-the-fly cell mechanical phenotyping. Nature methods 12, 199–202, 194 p following 202, doi:https://doi.org/10.1038/nmeth.3281 (2015).
Xavier, M. et al. Mechanical phenotyping of primary human skeletal stem cells in heterogeneous populations by real-time deformability cytometry. Integrative Biology 8, 616–623, https://doi.org/10.1039/C5IB00304K (2016).
Mietke, A. et al. Extracting cell stiffness from real-time deformability cytometry: theory and experiment. Biophysical Journal 109, 2023–2036, https://doi.org/10.1016/j.bpj.2015.09.006 (2015).
Migliaccio, A. R. Erythroblast enucleation. Haematologica 95, 1985–1988, https://doi.org/10.3324/haematol.2010.033225 (2010).
Chasis, J. A. & Mohandas, N. Erythroblastic islands: niches for erythropoiesis. Blood 112, 470–478, https://doi.org/10.1182/blood-2008-03-077883 (2008).
Shin, T. H. et al. Quality and freshness of human bone marrow-derived mesenchymal stem cells decrease over time after trypsinization and storage in phosphate-buffered saline. Scientific reports 7, 1106, https://doi.org/10.1038/s41598-017-01315-0 (2017).
Gossett, D. R. et al. Label-free cell separation and sorting in microfluidic systems. Analytical and bioanalytical chemistry 397, 3249–3267, https://doi.org/10.1007/s00216-010-3721-9 (2010).
Mathur, A. B., Truskey, G. A. & Monty Reichert, W. Atomic Force and Total Internal Reflection Fluorescence Microscopy for the Study of Force Transmission in Endothelial Cells. Biophysical journal 78, 1725–1735 (2000).
Costa, K. D. & Yin, F. C. Analysis of indentation: implications for measuring mechanical properties with atomic force microscopy. Journal of biomechanical engineering 121, 462–471 (1999).
Li, M. et al. Atomic force microscopy imaging and mechanical properties measurement of red blood cells and aggressive cancer cells. Science China. Life sciences 55, 968–973, https://doi.org/10.1007/s11427-012-4399-3 (2012).
Keerthivasan, G., Wickrema, A. & Crispino, J. D. Erythroblast enucleation. Stem cells international 2011 (2011).
Sajeesh, P., Raj, A., Doble, M. & Sen, A. K. Characterization and sorting of cells based on stiffness contrast in a microfluidic channel. RSC Advances 6, 74704–74714, https://doi.org/10.1039/C6RA09099K (2016).
Fletcher, D. A. & Mullins, R. D. Cell mechanics and the cytoskeleton. Nature 463, 485–492, https://doi.org/10.1038/nature08908 (2010).
Gratzer, W. B. The red cell membrane and its cytoskeleton. Biochemical Journal 198, 1–8 (1981).
Hebiguchi, M. et al. Dynamics of human erythroblast enucleation. International journal of hematology 88, 498–507, https://doi.org/10.1007/s12185-008-0200-6 (2008).
Konstantinidis, D. G. et al. Signaling and cytoskeletal requirements in erythroblast enucleation. Blood 119, 6118–6127, https://doi.org/10.1182/blood-2011-09-379263 (2012).
Ribeiro, A. S. & Dahl, K. N. The nucleus as a central structure in defining the mechanical properties of stem cells. Conference proceedings:… Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2010, 831–834, https://doi.org/10.1109/iembs.2010.5626785 (2010).
Rosenbluth, M. J., Lam, W. A. & Fletcher, D. A. Force Microscopy of Nonadherent Cells: A Comparison of Leukemia Cell Deformability. Biophysical journal 90, 2994–3003 (2006).
Griffiths, R. E. et al. Maturing reticulocytes internalize plasma membrane in glycophorin A-containing vesicles that fuse with autophagosomes before exocytosis. Blood 119, 6296–6306, https://doi.org/10.1182/blood-2011-09-376475 (2012).
Vinckier, A. & Semenza, G. Measuring elasticity of biological materials by atomic force microscopy. FEBS Letters 430, 12–16, https://doi.org/10.1016/S0014-5793(98)00592-4 (1998).
Kiss, R. et al. Elasticity of human embryonic stem cells as determined by atomic force microscopy. Journal of biomechanical engineering 133, 101009 (2011).
Ciasca, G. et al. Mapping viscoelastic properties of healthy and pathological red blood cells at the nanoscale level. Nanoscale 7, 17030–17037, https://doi.org/10.1039/c5nr03145a (2015).
Acknowledgements
We would like to acknowledge the ZELLMECHANIK DRESDEN, for providing us the access to the Real-Time Deformability Cytometer (RT-DC), especially Oliver Otto and Christoph Herold for their technical support and assistance. We wish to acknowledge University of Edinburgh Flow Cytometry Facility, especially Martin Waterfall for his technical support. We wish to acknowledge IBioIC, Scottish Funding Council (SFC) and the MRC Confidence in Concept for providing resources for this research. Support for this work in general and MMZ’s work, in particular, was provided by the Scottish Funding Council as part of the NovoSang consortium and is gratefully acknowledged.
Author information
Authors and Affiliations
Contributions
E.G. performed the RT-DC, and M.M.Z. performed the A.F.M., experiments and data analysis. F.D. and N.W. worked on the cell differentiation protocol. MJ contributed to the data analysis, especially the ROC curve. All authors contributed to the design of experiments and writing of the paper.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Guzniczak, E., Mohammad Zadeh, M., Dempsey, F. et al. High-throughput assessment of mechanical properties of stem cell derived red blood cells, toward cellular downstream processing. Sci Rep 7, 14457 (2017). https://doi.org/10.1038/s41598-017-14958-w
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-14958-w
- Springer Nature Limited
This article is cited by
-
Biomechanics of circulating cellular and subcellular bioparticles: beyond separation
Cell Communication and Signaling (2024)
-
Microparticles with tunable, cell-like properties for quantitative acoustic mechanophenotyping
Microsystems & Nanoengineering (2023)
-
Divalent magnesium restores cytoskeletal storage lesions in cold-stored platelet concentrates
Scientific Reports (2022)