Abstract
Objective
To evaluate the clinical performance of self versus light-cured universal adhesive in non-carious cervical lesions (NCCLs) after 18 months.
Materials and methods
Sixty-eight NCCLs in 28 patients were divided into two equal groups; G1: self-cured universal adhesive (Palfique,Tokuyama,Japan) and G2: light-cured universal adhesive (Single Bond Universal,3 M ESPE,USA). Nanohybrid resin composite (Z350XT, 3 M ESPE, USA) was used as a final restoration. Evaluation for fracture, loss of retention, marginal adaptation and discoloration were done after 1 week, 6,12, and 18 months using FDI criteria. Postoperative sensitivity was assessed after 1 week. Chi-Square and Mann-Whitney tests with statistical significance at (P ≤ 0.05) were used for intergroup comparison,while the intragroup one was performed using the Cochran’s Q and Friedman’s tests. Survival rate was analyzed using Kaplan-meier and Log-rank test.
Results
Both groups exhibited fracture and retention loss, however, there was statistically significant difference favoring the control group at 6 months (p = 0.0114,0.0016). For secondary outcomes, marginal adaptation and discoloration revealed no significant differences. For postoperative sensitivity, there was a significant difference favoring the control group (p = 0.0007, 0.0011). Palfique had 1.5 Relative-Risk (RR) after 6 months (95% CI 0.5659–4.2617; P = 0.3928) and 20% less risk of failure after 18 months (RR 0.8) (95% CI 0.4618–1.3858; P = 0.4260). Tested adhesives showed equal survival rate (P = 0.5685).
Conclusions
Both adhesives revealed similar clinical performance in restoring the NCCLs after 18 m, however, the early failure was more frequent in the self-cured universal adhesive.
Similar content being viewed by others
Introduction
Non carious cervical lesions (NCCLs) are lesions that affect the hard tooth structure without any bacterial pathogenesis. They have different causative factors and consequently, they are classified into chemical, mechanical or chemo-mechanical lesion. Their prevalence (NCCLs) was about 46% in adult population and currently raised to 53% in adults above 30 years worldwide [1]. However, there is a lack of knowledge about the prevalence of these lesions among the Egyptian population. Retention loss of restorations placed in NCCLs continues to be a major concern for clinicians, since it can be affected by many factors that include the difficulty of adhesion between tooth structure and the restorative materials, the lesion extension, the degree of dentin sclerosis, and the adequate establishment of the hybrid layer. The direct and indirect forces are other factors that could have a negative impact on the durability of the NCCLs restorations. They include the masticatory forces especially the micro-shear force and the forces of parafunctional habits if exist. Furthermore, the acidic challenge that could affect the bondability of the restorative material in the erosive lesions with chemical etiology. So, there is a huge variety in degree of retention loss ranges from 0 to 50% [2]. This makes these types of lesions the most challenging condition for testing tooth adhesion in the clinical trials.
The idea of dental adhesion was developed in 1949, by Dr. Hagger a Swiss chemist who started using adhesives as a dentinal seal underneath restoration. These adhesives were classified according to the complexity of technique used into different generations which refer to the order by which they were developed. In the early 1990s, a revolution in the adhesive protocol occurred by introducing three-step etch and rinse adhesive system that was later simplified to two-step etch and rinse and two-step self-etch 2 adhesive systems. In the late 1990s another modification in the form of All-in-one adhesive was done to facilitate the bonding procedures through reducing the multiple steps system with more simplified application procedures to reduce the technique sensitivity, application time and increase patient satisfaction [3]. Multi-mode or universal adhesives have been introduced in the market following the previously mentioned types of adhesives, they can be used with all adhesion strategies after deciding the most suitable strategy for each type of tooth substrate whether it is enamel or dentin [4]. The rationale behind their introduction was to decrease steps and technique sensitivity by providing a single product suitable for all different strategies and offering more privilege due to their chemical bonding to tooth structure with its unique composition [5]. Majority of these adhesives were light cured to take the privilege of the command setting and maturity of the hybrid layer at the time of composite application. However, light cured adhesives face a great challenge in deep cavities and in areas inaccessible to light which dictate double or triple the curing time making the application technique longer and sensitive.
Further attempts were done by the adhesive industry to make the procedures less technique sensitive and more successful. One of these attempts was to eliminate the light curing step, this will not only counteract the problem of incompatibility with dual cured resin cement while cementing the indirect tooth-colored restorations but also will help in bonding of direct resin composite restorations in cases facing difficulty for light to reach as in deep inaccessible areas. Such recommendations were adopted by the manufacturer, Tokuyama, Japan [6]. Currently all the available literature that assessed the performance of this self-cured adhesive was in vitro studies, that is why this study was conducted [7, 8]. It was aimed to analyze the clinical performance of this adhesive in comparison to the light cured universal one in restoring cervical NCCLs. The null hypothesis tested stated that there is a similar clinical performance of both adhesives after 18 months follow up.
Methods
The current clinical study was performed using the protocol described by the Consolidated Standards of Reporting Trials (CONSORT) and conducted according to the ethical principles outlined in the World Medical Association Declaration of Helsinki. This two-parallel armed randomized control clinical trial was held in the outpatient clinic of the Conservative Dentistry Department, Faculty of Dentistry, Cairo University, after registration at www.clinicaltrials.gov by ID number NCT04572386 and ethical approval number 11.9.20, from October 2020 to April 2023 with equal allocation ratio of 1:1. As the broadest applicability of findings comes from randomized controlled trials, it was recommended to include the sample per patient (two-parallel armed) not per tooth to increase patient variations and consequently increases the applicability [9, 10]. Simple randomization was conducted by computerized sequence generation by someone who is not involved in the research. Participants, statisticians, and the outcome assessors were blinded. Details of the materials used are presented in Table 1.
Sample size calculation
The sample size was calculated based on a previous study by Perdigao et al. in 2014 in which percentage of successful restorations of NCCLs performed by universal adhesive preceded by selective enamel etching can be observed in 98% of cases [11]. By implementing a two tailed Z test for difference between two independent proportions with an alpha level of 5% and a power of 80%. The minimum sample size needed was 30 teeth per group to detect a difference of 25%. Sample size was increased by 10% to compensate for possible dropouts to reach 34 teeth per group. Sample size was performed using G*Power version 3.1.9.2 for windows.
Patients’ enrollment
Twenty-eight patients with 68 NCCLs who matched the eligibility criteria were enrolled after signing an informed consent for ethical and legal issues. Patients’ demographic distribution is presented in Table 2. NCCLs were further categorized according to the Smith and Knight wear index depending on teeth contour and depth of lesion and Sclerosis index which categorized the degree of sclerosis according to the lesion color, recorded after the cavity preparation to control the lesion diminution limits as shown in Table 3 [12, 13]. After 18 months 56 restored cavities were assessed with 81.2% retention rate.
After controlling or removing etiological factors, adult patients aged 25–55 with NCCLs and low to moderate caries risk were included. Patients who could not return for recall appointments or had abnormal oral or mental conditions, untreated extra occlusal stresses, TMJ problems, systemic conditions, or having less than 20 teeth under occlusion were excluded. Regarding teeth inclusion criteria, vital teeth with NCCLs, sclerosis index and wear Index from 1–3, and having normal or minimum mobility (grade 1) were included. On the contrary, teeth with cervical caries, periodontal disease that may affect the prognosis of the restoration or the tooth itself, severe hypersensitivity, pulpal involvement or necrosis, and intense subgingival lesion that prevents rubber-dam isolation and violates the biological width were excluded. Thorough information regarding patient dental and medical history with any predisposing factors were collected using a customized diagnostic chart, including ADA caries risk assessment. Extra and intra-oral examinations were performed to identify the etiological factor to facilitate removing or reducing the etiological factor preoperatively, (Table 4).
Assessor calibration
Clinical assessment of the restorations by FDI criteria was done by two expert blinded assessors. Furthermore, calibration sessions for the two assessors (AS and RH), one month before the assessment appointment were conducted till a high degree of agreement was achieved between them. Such calibration was calculated on 10 patients not included in the trial. In case of disagreement extended in depth discussion was done till reaching consensus. Intra and inter assessor agreement was tested by Cohen’s Kappa test after the calibration sessions and it was excellent (97 and 99% respectively).
Cavity preparation and restorative procedures
Following the prophylaxis session, teeth were anesthetized using Artpharmadent 1:100,000 (Articaine /epinephrine) to avoid any pain during isolation and cavity preparation and to minimize the outward flow of the dentinal fluids during bonding procedures. Incisal/occlusal enamel beveling (1–1.5 mm) was performed using a high-speed red-coded tapered stone (MANI, Japan) in 45° angulation under water coolant [14]. Stones were discarded after a maximum of 5 teeth. Under rubber dam isolation, selective enamel etching for 20 s was conducted. Palfique Universal Bond (Tokuyama, Japan), which is a two-bottle self-cured universal dental adhesive system, was used as an intervention. Adhesive bottles were shaken thoroughly before use, and one drop from each bottle was dispensed at equal proportion and then mixed by a micro-brush till a bluish color was observed. Then, two coats were applied to the previously prepared cavity by rubbing action for 10 s to ensure proper infiltration of the bond. As instructed by the manufacturer, there is no need for waiting, only gentle air thinning until no adhesive movement is seen, then directly proceed with nanohybrid resin composite application (Filtek Z350 XT), (Fig. 1).
For the comparator group, light cured Single bond universal adhesive SBU (3 M ESPE, USA) was used. One drop was directly dispensed on the micro-brush, then applied on the prepared cavity using rubbing action. Again, two coats were applied, left undisturbed for 10 s each, gentle air thinned with water/air tip for 10 s, and light cured after the second layer for 20 s at zero distance from cavity margins and in a perpendicular direction using calibrated LED light curing unit (LED F, Woodpecker, China) with 1600 mW/cm2, as shown in Fig. 2 [15].
Suitable dentin shade from the nanohybrid resin composite (Z350 XT, 3 M oral care, USA) was used for both intervention and control groups to ensure standardization of the restoration. This type was selected as it has shown superiority in surface smoothing, color stability, and esthetics [16, 17]. Composite was added in increments; each increment was shaped as a sausage to facilitate placement, adaptation, and reaching proper contour using an Elephant composite applicator (EL2). Each increment was light-cured for 20 s using the same curing unit from zero distance.
For finishing, high-speed, yellow-coded tapered stone with a rounded end (MANI, Japan) operated at 10,000 rpm under water coolant in one direction was used, followed by sequential TOR VM disks and EVE polishing tips, giving a finalized smooth surface.
Outcomes
The restorations were evaluated following FDI criteria [18, 19]. Both primary (Fracture and loss of retention) and secondary outcomes (Marginal adaptation and discoloration) measurements were recorded after one week, 6, 12, and 18 months. First, a visual evaluation was performed to ensure no retention loss, and then tactile evaluation using an FDI probe (150 and 250 microns) was conducted to check the rocking, cracking, or ditching according to the FDI guidelines. The probe was moved gently at a right angle from tooth to restoration and vice versa, Fig. 3 [14]. Post-operative sensitivity was evaluated after a one-week follow-up using the visual analog scale. A triple air syringe was used at the cavity margin for 5 s to trigger the stimulus and facilitate the identification of pain expression. The follow up of the patient is demonstrated in consort flowchart, Fig. 4 The lost patients during follow up were treated in intention to treat strategy.
Statistical analysis
Data was analyzed using Medcalc software, version 19 for windows (MedCalc Software Ltd, Ostend, Belgium). Ordinal data was described as frequency and percentage, intergroup comparisons between interventions was performed using Chi-Square and Mann–Whitney tests with statistical significance level set at (P ≤ 0.05), intragroup comparison within each intervention was performed using the Cochran’s Q and Friedman’s tests with statistical significance level set at (P ≤ 0.0083) after Bonferroni correction. Relative risk was used to assess the clinical significance. Survival rate was analyzed using Kaplan-meier and Log-rank test. The confidence limit was set at 95% with 80% power and all tests were two tailed.
Results
In the current study intergroup comparison between both adhesives using Mann-whitney and Chi-square tests revealed no statistically significant differences for all tested outcomes at all follow-up periods (p > 0.05), except for postoperative sensitivity after 1 week (p = 0.0007) and fracture and retention at 6 months (p = 0.0114) where there was significant difference favoring Single bond universal (P < 0.05). Intragroup comparison within each adhesive using Friedman’s and Cochran’s Q tests revealed statistically significant differences between follow-up periods (p < 0.0083), except for marginal adaptation and discoloration within Palfique adhesive, where there was no statistically significant difference (p > 0.0083) using Cochran’s Q test (p = 0.194 and 1.0000 respectively) (Table 5).
There was 1.5 times more risk for failure in Palfique group when compared to SBU after 6 months, RR 1.5 (CI (0.5659–4.2617) at p = 0.3928). On the other hand 20% less risk of failure was detected in Palfique adhesive when compared to SBU after 18 months, RR 0.8 (CI (0.4618–1.3858) at p = 0.4260).
Overall survival of composite restorations using both adhesives was assessed after 6 and 18 months. Results revealed that Palfique showed early failure of 8 restorations, while SBU showed early failure of 5 restorations after 6 months with a success rate of 76.5% and 82% respectively. While, there were12 restorations in Palfique group and 15 restorations in SBU group were scored as failed restorations (score 4 and 5) after 18 months using FDI criteria with a success rate of 58% and 46.5% respectively with non statistically significant difference between both adhesives (p = 0.5685). (Fig. 5).
Discussion
Achieving successful and long-lasting bonding to tooth structure is one of the most important goals for any dentist wants to practice minimal invasive dentistry. However, this goal is not easy to be achieved due to several challenges facing the clinicians like the substrates involved and the choice between many available adhesives. Each substrate and adhesive dictate certain protocol for bonding. Unfortunately, multiple published laboratory studies have tested different dental adhesives’ properties but they did not reflect their clinical performance [20]. Therefore, this is the first study to evaluate the clinical performance of self-cured universal adhesive (Palfique,Tokuyama,Japan) in comparison to one of the most commonly used light cured universal adhesive (Single Bond Universal,3 M ESPE,USA). It was claimed that Palfique has low technique sensitivity as stated by the manufacturer in addition, it is supplied in two bottles, which gives it the advantage of being more stable, as curing will only happen after mixing. Another important issue is related to its composition, which contains borate self-etch (BoSe) with 3d-SR technology. Three-dimensional cross-linking occurs by calcium interaction, adhesive 3D-SR monomers, and other monomers that lead to optimal fast polymerization and a strong bonding layer. This process occurs by contact cure, where the phosphoric acid monomer breaks down the borate initiator, turning it into borane molecules, which generate free radicals. Moreover, peroxide accelerates the degradation of the borane compound, which acts as a highly active chemical polymerization initiator. When this bonding layer encounters resin composite, it rapidly progresses through polymerization and becomes cured on its adhesive interface (contact-cure). However, the clinical performance of this adhesive is not fully approved in the literature. On the other hand, the light-cured universal adhesive is characterized by its ability to bond chemically to the tooth structure owing to the presence of 10-MDP functional monomer and polyalkenic acid [21, 22].
Clinical performance of these adhesives was tested in NCCLs as the retention here depends mainly on the bond quality without any mechanical retention support. Moreover, these lesions have sclerotic dentin which is considered the most problematic bondable coronal substrate as mentioned in the introduction. 20It is not easily etched like normal dentin because of its ultrastructure, including hypermineralization on the surface with denatured collagen and bacteria invasion with obliteration of the dentinal tubules by crystalline deposits. In the current study, the most common sclerosis scores were 1 and 2, which show weak or no signs of sclerosis, while score 3 was only detected in the intervention group. This could be one of the reasons that explains the increased failure rate regarding the early retention loss in the intervention group. The FDI criteria were also selected to evaluate the restoration because of its detailed and meticulous evaluation parameters. It includes three main parameters considering functional, esthetic, and biological, with 16 subcategories, from 1 to 5, according to detailed, clear guidelines [18] that enable the clinician to easily quantify and evaluate the restoration change in short-term clinical studies. It is worth mentioning that the leading cause of NCCLs restoration failure is the retention loss and fracture [23, 24]. That is why retention loss and fracture were taken as a primary outcome, followed by marginal adaptation and marginal discoloration [25].
Fracture and retention loss results revealed a statistical decrease in FDI score 1 and a significant increase in FDI scores 2, 4, and 5 from 1 week to 18 months, indicating the increase in the rate of restoration deterioration ranging from minor marginal chip fracture to complete restoration loss. Furthermore, there are statistically significant differences between both tested groups at 6 months, favoring the comparator as it showed less fracture and retention loss. This can be attributed to the degree of conversion of the adhesives when using a light cure. Light increases the degree of conversion instantly, while in self-cured, it depends on the conversion rate over a certain time, which will be significantly affected by the intraoral condition when put into function as moisture contamination and force of mastication. This is besides the polymerization shrinkage of the resin composite that might negatively affect the self-cured adhesive which was not fully cured at the restoration time. Furthermore, in the light cured adhesive, the functional monomers with strong and stable chemical affinity to hydroxyapatite improved adhesive performance and gave better retention (10-MDP). Moreover, light-cured adhesive exhibited significantly higher shear bond strength values and the lowest nano leakage, followed by self-cured universal adhesive, which attributed to the variation in failure rate between the two bonds [26]. These results were confirmed by the relative risk and survival rate findings of the current study as the self-cured universal adhesive showed 1.5 more failure risk than the light cured one after 6 months and similar survival rate after the 18 months. On the contrary Xu et al. in 2006 stated that the polymerization of light cured adhesive has got negatively affected by increasing the distance between the curing light and the adhesive layer, however, in this study cavities were not too deep for the light to fully reach the adhesive [27].
With reference to marginal adaptation and marginal discoloration, there was a significant decrease in FDI score 1 with a significant increase the other scores from 1 week to 18 months. The control group showed preservation of marginal properties after 6 months compared to the intervention group but without statistically significant difference. At 12 and 18 months, the remaining restorations gave comparable results; consequently, marginal adaptation should not be included alone without the fracture and retention value. This deterioration can be due to minor fractures at the margin caused by the unpolymerized bond that showed weak tensile and shear bond strength. This explanation can correlate bond strength values obtained in the in vitro studies with the clinical outcomes. Besides, the presence of rough margins due to marginal deterioration which can increase the chance of marginal discoloration by being more retentive [28]. On the other hand, Palfique showed higher post-operative sensitivity at 1 week [29]. Most of the cases that reported post-operative sensitivity showed loss of retention in the intervention group, which can be explained by the incomplete polymerization of the self-cured adhesive, making the material more liable to nano leakage. For these reasons and under the circumstances of the current study the null hypnosis was partially rejected.
Finally, it is worth mentioning that within the limitation of this study, both types of adhesives showed similar clinical performance after 18 months in NCCLs. This finding emphasizes the great influence of the oral environmental factors, starting from the nature of tooth structure and going through the human variations such as masticatory force and dietary habits, on the serviceability of the resin composite restorations in the NCCLs.
Conclusions
Following the current trial’s circumstances and limitations, it can be concluded that,
-
Light-cured adhesive may offer some advantages over self-cured one in term of number of restorations with early failures.
-
Similar studies might be needed to insure the reliability of self-cured universal adhesive for direct resin composite restorations under different circumstances.
The current study raised some recommendations for the researchers, which are;
-
An extended follow-up period is required to evaluate the long-term survival of each group.
-
Studying the influence of the degree of sclerosis on the clinical performance of the adhesives will be of great value.
-
Comparing the clinical performance of self-cured adhesive in areas away from or not accessible to light with the light-cured adhesive might be necessary.
Data availability
Full data are available whenever requested.
References
Teixeira DN, Thomas RZ, Soares PV, Cune MS, Gresnigt MM, Slot DE. Prevalence of noncarious cervical lesions among adults: a systematic review. J Dent. 2020;95:1–7.
Rocha AC, Da Rosa WL, Cocco AR, Da Silva AF, Piva E, Lund RG. Influence of surface treatment on composite adhesion in noncarious cervical lesions: systematic review and meta-analysis. Oper Dent 2018;43:508–19.
Sofan E, Sofan A, Palaia G, Tenore G, Romeo U, Migliau G. Classification review of dental adhesive systems: from the IV generation to the universal type. Ann Stomatol. 2017;8:1–17.
Ilday NO, Sagsoz O, Karatas O, Bayindir YZ, Rifaioglu VT. Dentin bonding performance and nanoleakage properties of universal adhesives in different etching modes. Saudi J Oral Dent Res. 2016:137-46.
Tsujimoto A, Barkmeier WW, Takamizawa T, Watanabe H, Johnson WW, Latta MA, et al. Comparison between universal adhesives and two‐step self‐etch adhesives in terms of dentin bond fatigue durability in self‐etch mode. Eur J Oral Sci. 2017;125:215–22.
Palfique universal bond (technical report,2017) https://acrobat.adobe.com/id/urn:aaid:sc:EU:c0d72ad5-800e-4dfcb0f6-1cb5d84211bf.
Serin-Kalay T, Zaim B. Effect of alternative self-etch applications on dentin bond strength of “No Wait Concept” universal adhesives. Int J Dent Sci 2022;24:58–66.
Kibe K, Hatayama T, Shimada Y. In vitro performance of an autocured universal adhesive system in bonding to dentin. BMC Oral Health. 2023;23:933–45.
Donner A, Zou GY. Methods for the statistical analysis of binary data in split‐mouth designs with baseline measurements. Stat Med. 2007;26:3476–86.
Smaïl-Faugeron V, Fron-Chabouis H, Courson F, Durieux P. Comparison of intervention effects in split-mouth and parallel-arm randomized controlled trials: a meta-epidemiological study. BMC Med Res Methodol. 2014;14:64.
Perdigão J, Kose C, Mena-Serrano AP, De Paula EA, Tay LY, Reis AL, Loguercio AD. A new universal simplified adhesive: 18-month clinical evaluation. Oper Dent. 2014;39:113–27.
García VD, Freire Y, Fernández SD, Murillo BT, Sánchez MG. Application of the intraoral scanner in the diagnosis of dental wear: an in vivo study of tooth wear analysis. IJERPH. 2022;19:4481–5.
Sun X, Ban J, Sha X, Wang W, Jiao Y, Wang W, et al. Effect of Er, Cr: YSGG laser at different output powers on the micromorphology and the bond property of non-carious sclerotic dentin to resin composites. PLoS One. 2015;10:e0142311.
Goodacre CJ, Eugene Roberts W, Munoz CA. Noncarious cervical lesions: Morphology and progression, prevalence, etiology, pathophysiology, and clinical guidelines for restoration. J Prosthodont. 2023;32:e1–8.
Carvalho CN, Lanza MD, Dourado LG, Carvalho EM, Bauer J. Impact of solvent evaporation and curing protocol on degree of conversion of etch-and-rinse and multimode adhesives systems. Int J Dent. 2019;2019:5496784.
Nair VS, Sainudeen S, Padmanabhan P, Vijayashankar LV, Sujathan U, Pillai R. Three-dimensional evaluation of surface roughness of resin composites after finishing and polishing. J Conserv Dent. 2016;19:91–95.
Setty A, Nagesh J, Marigowda J, Shivanna A, Paluvary S, Ashwathappa G. Comparative evaluation of surface roughness of novel resin composite Cention N with Filtek Z350 XT: In vitro study. Int J Oral Care Res. 2019;7:15–17.
Hickel R, Peschke A, Tyas M, Mjör I, Bayne S, Peters M, et al. FDI World Dental Federation: clinical criteria for the evaluation of direct and indirect restorations—update and clinical examples. Clin Oral Investig. 2010;14:349–66.
Donmez SB, Uysal S, Dolgun A, Turgut MD. Clinical performance of aesthetic restorative materials in primary teeth according to the FDI criteria. Eur J Paediatr Dent. 2016;17(Mar):202–12.
Perdigão J. Current perspectives on dental adhesion:(1) Dentin adhesion–not there yet. Jpn Dent Sci Rev. 2020;56:190–207.
Ahmed AA, Hassan MM, Abdalla AI. Microshear bond strength of universal adhesives to dentin used in total-etch and self-etch modes. Tanta Dent J. 2018;15:91–98.
Doshi K, Nivedhitha MS, Solete P, Balasubramaniam A, Jacob B, Siddique R. Effect of adhesive strategy of universal adhesives in noncarious cervical lesions–an updated systematic review and meta-analysis. BDJ Open. 2023;9:6.
Zanatta RF, Silva TM, Esper MA, Bresciani E, Goncalves SE, Caneppele TM. Bonding performance of simplified adhesive systems in noncarious cervical lesions at 2-year follow-up: a double-blind randomized clinical trial. Oper Dent. 2019;44:476–87.
De Paris Matos T, Perdigao J, De Paula E, Coppla F, Hass V, Scheffer RF, et al. Five-year clinical evaluation of a universal adhesive: A randomized double-blind trial. Dent Mat. 2020;36:1474–85.
Follak AC, Ilha BD, Oling J, Savian T, de Oliveira Rocha R, Soares FZ. Clinical behavior of universal adhesives in non-carious cervical lesions: A randomized clinical trial. J Dent. 2021;113:103747.
Mahmoud SS, Anwar MN, Ghallab OH, Ibrahim MN. The effect of auto-polymerizing, photo-polymerizing and dual-polymerizing self-etching adhesive systems on shear bond strength and nano-leakage of two direct resin composite core materials: an in-vitro study. Egypt Dent J. 2020;66:1–9.
Xu X, Sandras DA, Burgess JO. Shear bond strength with increasing light‐guide distance from dentin. Restor. 2006;18:19–28.
Madrigal EL, Tichy A, Hosaka K, Ikeda M, Nakajima M, Tagami J. The effect of curing mode of dual-cure resin cements on bonding performance of universal adhesives to enamel, dentin and various restorative materials. Dent Mater J. 2021;40:446–54.
Ruschel VC, Shibata S, Stolf SC, Chung Y, Baratieri LN, Heymann HO, et al. Eighteen-month clinical study of universal adhesives in noncarious cervical lesions. Oper Dent. 2018;43:241–9.
Acknowledgements
To Dr. Omar Shaalan Associate professor at faculty of dentistry Cairo university- for his quick response in performing the needed statistical analysis and without any charges. The current clinical study was performed using the protocol described by the Consolidated Standards of Reporting Trials (CONSORT) and conducted according to the ethical principles outlined in the World Medical Association Declaration of Helsinki. This two-parallel armed randomized control clinical trial was held in the outpatient clinic of the Conservative Dentistry Department, Faculty of Dentistry, Cairo University, after registration at www.clinicaltrials.gov by ID number NCT04572386 and ethical approval number 11.9.20, from October 2020 to April 2023 with equal allocation ratio of 1:1. Patients were enrolled after signing an informed consent for ethical and legal issues.
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).
Author information
Authors and Affiliations
Contributions
AGAH: main Operator, data entry and writing manuscript RHAE: Revising main script, auditing and assessor AAY: Revising main script, assessor, and auditing.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ashour, A.G., Abd ElAziz, R.H. & Yassen, A.A. Performance of self-cured versus light-cured universal adhesive in patients with non-carious cervical lesions: 18-month randomized clinical trial. BDJ Open 10, 25 (2024). https://doi.org/10.1038/s41405-024-00204-9
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41405-024-00204-9
- Springer Nature Limited