1 Introduction

Biomedical implants are used for reconstituting the functionality of damaged organs or tissues. There is a variety of biomedical implants based on metallic, ceramic, and polymeric materials. Metallic implants can be classified as steels, cobalt/cobalt alloys, and titanium/titanium alloys. Among them, titanium (Ti) and its alloys have been extensively used owing to their excellent biocompatibility and mechanical properties [1,2,3,4]. However, implants may fail because of (i) lack of integration with tissue and (ii) infections that are the consequence of bacterial attachment to the implant surface and the subsequent development of a biofilm. Implant-associated infection is a serious complication since it is not only resistant to natural host defense mechanisms, but also resistant to most antibiotics and antimicrobial treatment [5]. It has been reported that a very large proportion of implant-related infections are caused by Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis) [6]. In the last decades, S. epidermidis has been the most isolated bacteria from hospital and biomaterial-related infections [7, 8]. S. epidermidis also easily adheres and proliferates on Ti surfaces.

The approaches to reduce protein adsorption which contributes to bacterial attachment and biofilm formation include the modification of surfaces by hydrophilic chains, anticoagulant coatings, phosphorylcholine-modified polymer coatings, and poly(ethylene glycol) (PEG)-based coatings [9,10,11,12,13,14]. A method to inhibit bacterial attachment by means of highly hydrated biocompatible polymers such as PEG (or polyethylene oxide, PEO) has been a promising approach. The water layer covers the surface, introducing a high activation barrier for bacteria to adhere, and also for proteins to adsorb [12, 15, 16]. It has been reported that the adhesion of many types of bacteria was substantially reduced by immobilized PEG and oligo (ethylene glycol) at implant surfaces [17,18,19]. The common approaches to immobilize PEG to the material surfaces include the covalent coupling of PEG chains [20], physical adsorption of PEG, graft copolymers [21], and plasma deposition methods [22].

Electrospinning which uses electrical forces to generate polymeric fibers with nano-/micro-sized diameters is an effective, cost efficient, and easily applied technique [23, 24]. Electrospun fibers have been successfully used in drug delivery, tissue engineering, and other biomedical applications due to their highly porous structures, high surface area to volume ratio, potential biocompatibility, and high functionality [25,26,27]. In the literature, although there are limited studies based on coating of Ti implants with electrospun fibers, to the best of our knowledge, no investigation has been demonstrated for PEO nanofiber-coated implant surfaces in terms of cellular/bacterial adhesion. In a recent study, S. aureus adhesion has significantly reduced on the Ti surfaces modified by PEO/poly(lactide-co-glycolic acid) compared with the unmodified ones [28]. In another study, adhesion and proliferation of osteoblasts were studied on electrospun PLGA or PLGA/collagen fiber-coated Ti discs [4].

In this paper, unlike modifying implant surfaces by techniques requiring high temperatures and chemicals, Ti implants were modified in a very effective way by electrospun PEO nanofibers without the need for an antimicrobial agent or further modifications. The attachment and proliferation of MC3T3-E1preosteoblasts and S. epidermidis on the uncoated and PEO nanofiber-coated Ti surfaces were investigated and compared.

2 Experimental studies

2.1 Coating of titanium implants with PEO nanofibers

Commercially pure (99.98%) titanium strips with 0.2-mm thickness were purchased from BAĞ-SAN Titanium Metal Corporation (Turkey). Some of the Ti strips were sandpapered with 180 grit SiC papers to compare the effect of surface roughness on fiber stability and cellular adhesion. The strips were then cleaned with ethanol using an ultrasonicator for 15 min. PEO (Mv:600,000 Da, Sigma-Aldrich) powder (0.4 g) was added into the 10-mL distilled water and the mixture was kept under vigorous magnetic stirring overnight at room temperature to obtain homogeneous PEO solution. After adding 10% (with respect to PEO wt) crosslinking agent pentaerythritol triacrylate (PETA, Sigma-Aldrich), the resultant solution was further stirred vigorously for 1 h under shading to disperse PETA. Then, the solution was loaded into 2.5-mL 21-gauge needle and it was placed to a syringe pump (NE 300, New Era Pump Systems) to obtain a steady flow at a flow rate of 0.4 mL h−1. A power of 18 kV was applied at a distance of 23 cm between the tip of the needle and the grounded collector. The PEO fibers were collected for 5 min on Ti samples (1 cm × 1 cm) fixed to a stationary collector. The coated Ti surfaces were kept at 37 °C for 8 days for complete drying of the PEO nanofibers. Then, the fiber-coated samples were placed under a high-intensity UV light source (a wavelength of 366 nm, GLT Gase-und Labortechnik Inc.) for crosslinking. The distance between Ti samples and the lamp head was 4 cm. The crosslinking process was realized for 50 min under room conditions. The coated implants were stored in a desiccator prior to further applications. Some of the crosslinked nanofiber-coated samples were kept in distilled water at 37 °C for 24 h and then, dried at room temperature to determine whether the fiber coatings were still on the surfaces or not. Ti samples used in the study and their abbreviations are listed in Table 1.

Table 1 Titanium samples used in the experimental studies and their abbreviations

2.2 Surface characterization

The surface analysis of the coated and uncoated Ti samples was done by a scanning electron microscope (SEM, Zeiss Evo 50) and atomic force microscope (AFM, Vecoo Multi Mode V-AS-12) operating at tapping mode. Prior to imaging, the samples were coated with gold layer. The average diameter of the fibers was determined from SEM images by using ImageJ software (NIH, Bethesda, MD). The diameters were presented as average ± standard deviation. The wettability of the samples was assessed by static water contact angle measurements with sessile drop method at room temperature (Kruss DSA 100). The surface roughness of uncoated samples was measured by a perthometer (Mahr, M2).

2.3 In vitro cell culture experiments

2.3.1 Cell seeding and culturing

Cell culture studies were conducted in sterile 24-well tissue culture polystyrene plates (TCPS, Orange Scientific) in stationary conditions. Prior to cell culture experiments, 24-well plates were coated with Parafilm. Then the coated plates were soaked in 96% ethanol and placed under UV light during 30 min for sterilization. Additionally, PEO-coated and uncoated titanium samples (1 cm × 1 cm) were sterilized under UV light for 30 min. Then, the samples were individually placed into single wells of a 24-well plate. The cell culture studies were carried out by using mouse preosteoblasts (MC3T3-E1, doubling time 33 h, No. RCB1126, Riken Cell Bank) at 37 °C in a humidified 5% CO2 atmosphere (Heraeus Instruments). At first, MC3T3-E1 cells were subcultured in flasks using α-Minimum Essential Medium (α-MEM, Hyclone) supplemented with 10% (v/v) fetal bovine serum (FBS) and 1% (v/v) penicillin-streptomycin (Biological Ind.). The cells maintained at 37 °C in a humidified CO2 (5%) atmosphere were dissociated with 0.01% (v/v) trypsin/10 mM EDTA (Sigma), centrifuged, and resuspended in the medium prior to cell seeding. Thereafter, 1 mL of cell suspension containing 5 × 104 cells in complete culture medium was added to each well having Ti samples. TCPS without Ti samples was used as control. The culture plates were incubated at 37 °C in a humidified 5% CO2 atmosphere.

2.3.2 Cell viability and microscopic imaging

The MC3T3-E1 cells on the Ti samples were quantitatively assessed with 3-[4, 5 dimethylthiazol-2-yl]-diphenyltetrazolium bromide (MTT, Sigma) at different culture periods. At selected time intervals (4th, 24th, and 48th hour), the culture medium was aspirated and washed with 600-μL phosphate buffer solution (PBS, pH:7.4). A total of 600 μL of serum-free culture medium supplemented with 60-μL MTT solution (2.5 mg mL−1 MTT dissolved in PBS) was added to each sample and the incubation was performed at 37 °C for 3 h. Then, the medium was removed from each well and Ti samples were transferred to another 24-well TCPS. A total of 400 μL of 0.04 M HCl in isopropanol solution was added to each well to dissolve formazan crystals. A supernatant of 200 μL was used for measuring optical density at 570 nm with reference to 690 nm using a microplate reader (Asys UVM 340). In addition, the stability of the PEO coatings was investigated for longer culture period, i.e., 28 days, by MTT measurements.

The cells attached onto the Ti samples were observed by SEM. This is why Ti samples were removed from the culture medium at the end of 4 h of incubation and they were gently washed with PBS and then, the cells were fixed with 2.5% (v/v) glutaraldehyde in 0.1 M Dulbecco’s PBS (DPBS) for 30 min. Subsequently, the materials were dehydrated in ethanol series (i.e., 30, 50, 70, 90, and 100%, respectively) and rinsed with hexamethyldisilazane (HMDS, Sigma). After being completely dried, the samples were mounted on aluminum stubs and coated with gold before morphological observation.

Statistical analysis was performed with Graph-Pad InStat statistic program (GraphPad Software). A Tukey–Kramer multiple comparisons test was applied to determine the significant differences among the groups at p < 0.05.

2.4 Bacteria culture

Bacterial adhesion on Ti surfaces was performed by using S. epidermidis (+) ATCC (American Type Culture Collection®) 12228™* (biofilm-forming strain) and S. epidermidis (−) ATCC® 35984™* (not biofilm-forming strain) that were purchased from KWIK-STIK Microbiologics. Bacteria strains were inoculated at 37 °C in Sheep Blood Agar overnight. On the next day, the produced colonies were inoculated as a single colony in Petri dishes containing Mueller–Hinton agar (Becton Dickinson) at 37 °C overnight. Then, the bacteria suspensions were prepared from the single colony and were additionally inoculated overnight at 37 °C so that they reached to logarithmic growth phase. At next step, bacteria suspension (equivalent to a 0.5 McFarland standard) with absorbance value of 0.1 at 600 nm was prepared in Mueller–Hinton broth. The final inoculum to 5 × 105 CFU/mL was accomplished by diluting the 0.5 McFarland suspensions 1:150, and subsequent 1:2.

Ti samples were sterilized by 70% ethanol and subsequently UV irradiation for 30 min and then, placed into 24-well TCPS. A bacteria suspension of 1 mL (5 × 105 CFU/mL) was added on each Ti surface for 2 h of incubation at 37 °C. At the end of the incubation period, nonadherent bacteria were removed from the surfaces by gently washing with sterile normal saline (0.9% w/v) three times. Ti strips with adherent bacteria were put into 1 mL of sterile normal saline and stirred in vortex additionally to dismount adherent bacteria from the surfaces. After serial dilution, 100 μL of the bacterial solution was taken out and plated onto Mueller-Hinton agar. The plates containing bacteria were incubated in an aerobic atmosphere at 37 °C for 24 h, and then the numbers of the surviving colonies were counted.

The bacterial attachment on Ti surfaces (Ti-b, Ti-b-crPEO) was investigated by using S. epidermidis (+) for SEM observation. Ti samples were sterilized by UV irradiation for 30 min and then placed into 24-well TCPS. A total of 50 μL of bacteria suspension (1 × 106 cfu mL−1) in tryptic soy broth (Merck) was cultured on the Ti surfaces for 24 h at 37 °C. At the end of the incubation period, nonadherent bacteria were removed from the surfaces by gently washing with PBS (pH 7.4) three times and the adherent bacteria were fixed with 2.5% (v/v) glutaraldehyde in 0.1 M DPBS for 20 min, dehydrated in ethanol series, and rinsed with HMDS for SEM analysis.

3 Results

The results of PEO coating, characterization, and cellular responses of Ti surfaces were given below.

3.1 Coating of Ti implants with PEO nanofibers

In this study, electrospinning was used for the modification of Ti surfaces by the PEO nanofibers. PEO having a wide range of molecular weight is nontoxic, hydrophilic, and biocompatible polymer. In this study, we used PEO at 600,000 Da molecular weight. Since PEO is highly soluble in water, it is necessary to crosslink it for obtaining insoluble nanofiber mats. Here, we chose UV-induced crosslinking in the presence of pentaerythritol triacrylate (PETA) [29]. In our previous study, electrospinning and crosslinking conditions were optimized in order to obtain continuous, bead-free, and insoluble nanofibers [23]. In this study, the PEO coating was performed on Ti samples according the previous results (Table 2).

Table 2 Optimized electrospinning and crosslinking conditions for the preparation of PEO-coated Ti surfaces

3.2 Surface characterization

In order to investigate surface topographies of Ti samples, SEM and AFM analyses were done. Figure 1 shows the topographies of bare Ti surfaces (Ti-b) and sandpapered Ti surfaces (Ti-p). When comparing with Ti-b (Fig. 1a, b), rougher surface texture of Ti-p drew the attention (Fig. 1c, d). Perthometer analysis also revealed that the surface roughness increased from 0.18 μm on Ti-b to 0.28 μm on Ti-p surfaces.

Fig. 1
figure 1

AFM images of (a, b) Ti-b and (c, d) Ti-p surfaces. a and c show 2D images, b and d show 3D images

To determine the effect of PETA on the fiber morphology and diameter, PEO nanofibers not including PETA were also collected on Ti-b surfaces. Figure 2 shows the SEM images of uncrosslinked and crosslinked PEO nanofibers on Ti strips. The images reveal that the fibers exhibited similar morphology in all samples. While the uncrosslinked PEO nanofibers on Ti-b had a diameter of 167 ± 29 nm (Fig. 2a), the crosslinked fibers on Ti-b and Ti-p had diameters of 184 ± 48 nm and 175 ± 50 nm, respectively (Fig. 2b, c). The results exhibited that the presence of PETA in the electrospinning solution did not cause any significant effect on the fiber diameter and morphology. However, the nanofibers exhibited narrower diameter distribution in the absence of PETA (Fig. 2a). The AFM images of crosslinked-PEO nanofiber coated Ti-b (Ti-b-crPEO) (Fig. 3a, b) and Ti-p (Ti-p-crPEO) (Fig. 3c, d) surfaces also disclosed that there was no significant difference between fiber morphologies on both surfaces. Nevertheless, the wavy structures observed in the fiber arrangement on Ti-p-crPEO indicated that the fiber morphology was affected by increased surface roughness (Fig. 3d).

Fig. 2
figure 2

SEM images of a Ti-b-PEO, b Ti-b-crPEO, c Ti-p-crPEO and their diameter distributions (2 KX, upper right images: 10KX)

Fig. 3
figure 3

AFM images of (a, b) Ti-b-crPEO and (c, d) Ti-p-crPEO (upper right images show higher magnifications); SEM and AFM images of (e, f) Ti-b-crPEO and (g, h) Ti-p-crPEO surfaces after treating with distilled water. Left column shows 2D images, right column shows 3D images

Some of the Ti-b-crPEO and Ti-p-crPEO samples were immersed into distilled water (37 °C) for 24 h and dried at room temperature in order to determine whether stable coating was available or not. After drying period, fibers fused with each other by generating membrane-like form on the Ti surfaces (Fig. 3e–h). This is important since such a coating provided an isolated environment that would inhibit/reduce interactions of the cells and the bacteria with the implant surfaces. The fiber coating on Ti-p (Fig. 3g, h) was more stable than that of Ti-b (Fig. 3e, f). Since Ti-p had higher number of attachment points due to its rougher surface, the fibers exhibited better attachment onto Ti-p surfaces.

The water contact angles of coated and uncoated surfaces were measured by sessile drop method immediately after deionized water drop contacted with the surfaces. The contact angle increased from 49° (Ti-b) to 65° (Ti-p) with increasing surface roughness and decreased significantly to 12° and 20° after coating with PEO nanofibers, respectively (Table 3).

Table 3 Water contact angles and surface roughness (measured by perthometer) of titanium samples

3.3 Adhesion of MC3T3-E1 preosteoblasts and S. epidermidis onto the Ti surfaces

In this study, the cellular attachment on bare, sandpapered, and PEO nanofiber-coated Ti surfaces were investigated and compared. SEM images belonging to the 4th hour of cell culture were taken to visualize the initial adhesion of preosteoblasts on the surfaces (Fig. 4a, b). It was obvious that both of the uncoated surfaces (Ti-b and Ti-p) supported cell attachment and the cells began to spread at the end of the 4 h of incubation on the surfaces by using their cytoplasmic extensions. However, there were less number of the cells with spherical morphology on the Ti-p surfaces (Fig. 4b) when compared with Ti-b surfaces (Fig. 4a).

Fig. 4
figure 4

SEM images of MC3T3-E1 preosteoblasts on a Ti-b, b Ti-p, c Ti-b-crPEO, and d Ti-p-crPEO (× 250, bottom right images: × 500) at the end of the 4 h of incubation (yellow arrows show the cells with spreaded morphology)

SEM images of MC3T3-E1 cells on Ti-b-crPEO and Ti-p-crPEO revealed that the number of the attached cells substantially reduced when compared with the uncoated ones (Fig. 4c, d). At the end of the 4 h of cell culture, the presence of a few cells with spherical morphology showed that the cell attachment requiring for cell-material was not achieved. This result shows the PEO directly affected and significantly inhibited the attachment of the preosteoblastic cells.

Figure 5 a shows the MTT results of the cells cultured on Ti-b, Ti-p, Ti-b-crPEO, Ti-p-crPEO, and TCPS for 48-h culture period. Mitochondrial activities of the cells on the Ti-p surfaces were higher than that of the cells on Ti-b. The highest activity was observed for the cells on TCPS. The MTT absorbance values decreased on PEO-coated surfaces depending upon decreasing cellular activity. Figure 5 b shows that the effect of PEO coating sustained for the long term (28 days).

Fig. 5
figure 5

Mitochondrial activities of MC3T3-E1 cells proliferated on a) Ti-b, Ti-p, Ti-b-crPEO, Ti-p-crPEO, and TCPS for 48 h (statistically significant differences, n = 3 *p < 0.005, **p < 0.01, ***p < 0.001—Ti-b is control; +p < 0.005, ++p < 0.01, +++p < 0.001—Ti-p is control; op < 0.005, oop < 0.01, ooop < 0.001—Ti-b-crPEO is control; and p < 0.005, ••p < 0.01, •••p < 0.001—Ti-p-crPEO is control); b) Ti-b and Ti-b-crPEO for 28 days (statistically significant differences, n = 3 ***p < 0.001; Ti-b is control)

In the following part of the study, S. epidermidis was used for assessing the bacterial attachment and colonization on the Ti-b and Ti-b-crPEO surfaces. Figure 6 a shows the SEM images of S. epidermidis (+) on Ti-b and Ti-b-crPEO after 24 h of incubation. According to the images, the bacteria attached and proliferated intensively and colonized on the uncoated samples. On the contrary, Ti-b-crPEO surface reduced bacterial attachment significantly due to the repellent effect of PEO’s polymer chains. Figure 6 b also supported that for both of the bacteria.

Fig. 6
figure 6

a SEM images of S. epidermidis colonies on Ti-b (× 500, bottom right image; 15 KX) and Ti-b-crPEO (1 KX) at the end of the 24 h of incubation. b Comparison of attachment behaviors of S. epidermidis (−) and S. epidermidis (+) on Ti surfaces

4 Discussion

Infection remains a major obstacle to the long-term performance of many implanted devices. The initial stage in the pathogenesis of the infection to the implanted device is the bacterial adhesion. It is known that a variety of factors affect bacterial adhesion, i.e., the presence of adhesive molecules, dissolved proteins, and surface properties of both the bacteria and the implant material [4, 30]. Among them, the properties of an implant such as its chemical composition, roughness, wettability, and steric hindrance are all thought to be important in the initial bacterial response to a material surface [31]. The same properties also affect the mammalian cell response, i.e., adhesion and proliferation behavior in the similar manner. As indicated firstly by Gristina [31], there is a race for the implant surface between bacteria and tissue cells. If the race is won by bacteria, tissue cells will not be able to establish themselves on implant surface. Furthermore, bacterial attachment and subsequent colonization lead to biofilm formation that results infection [3].

Several surface modifications have been developed for the purpose of discouraging microbial adhesion on the implant surfaces. In general, this can be achieved by either repelling or killing the approaching cells. The repelling of bacteria was performed with hydrogel coatings mostly based on immobilized PEO [12,13,14,15]. In this study, unlike these methods, stable PEO nanofibers are successfully coated onto Ti surfaces by applying sequential electrospinning and crosslinking processes. For this approach, the water solution of PEO and PETA was electrospun and then, crosslinking process was realized under UV irradiation. We carried out optimization and characterization studies for UV-crosslinked PEO nanofibers in our previous study [23], so we did not perform further characterizations in the presented study. Here, we modified the procedure reported by Zhou et al. for the preparation of UV-crosslinked electrospun PEO fibers [29]. During the electrospinning process, PETA was not excluded as reported before. PETA took a hydrogen atom from PEO when it was excited by UV light, and PEO and PETA radicals formed. PEO radicals attacked to the C=C bond of PETA to initiate the polymerization of PETA. Termination occurred by radical coupling and crosslinks formed between PEO and PETA. As a result, we obtained stable and permanent PEO coating on both bare and sandpapered Ti strips. Prior to coating, we did not apply any etching procedure with chemicals.

The anticellular characteristics of PEO coatings were investigated by using MC3T3-E1 preosteoblasts in fibroblastic morphology as a model tissue cell and S. epidermidis strain as a model of pathogenic bacteria. The higher number of spreaded preosteoblasts on Ti-p surfaces indicated that the cell attachment was enhanced on Ti-p surfaces. It could also be concluded that the cells adapted more easily to the Ti-p surfaces and their metabolic activities were enhanced in favor of surface roughness. Since the surface roughness of Ti-p implants increased, protein absorption was improved more accordingly on the rougher surface. Thus, the number of focal adhesion points became higher level and this led to increased cellular attachment and mitochondrial activity. Many studies have shown the higher adhesion ability of osteoblasts on rough Ti and Ti-6Al-4V compared with smooth Ti and Ti-6Al-4V surfaces [32, 33]. Neoh et al. [3] reported that Ti surfaces having various surface roughness had a different impact on osteoblast adhesion and the cell attachment was improved with increasing surface roughness. In contrast, Jayaraman et al. [34] compared a sandblasted, an acid-etched, and a grooved surface through in vitro systems. The grooved surface supported better osteoblastic cell adhesion and proliferation than that of the rough surfaces.

As expected, the cellular and bacterial attachment significantly reduced on both Ti-b-crPEO and Ti-p-crPEO due to the presence of PEO fibers. This result can be attributed to the steric barrier, excluded volume effect, and osmotic repulsion exerted by highly hydrated and flexible PEO chains.

5 Conclusion

The focus of this study was to propose a simple and effective anticellular coating method for metallic implants. This is why a two-step process including electrospinning and crosslinking was employed. At first, titanium surfaces were effectively coated with smooth and uniform PEO nanofibers. Then, stable PEO coating was obtained by crosslinking PEO nanofibers with PETA in the presence of UV irradiation. The comparative adhesion behavior of the mammalian cells and the bacteria on the different Ti surfaces, i.e., bare, sandpapered, and PEO nanofiber-coated surfaces, was investigated. PEO-coated Ti surfaces substantially reduced the cellular attachment without the need for further modifications. However, as shown in the study, such hydrophilic surfaces also prevented the adhesion of preosteoblastic cells which is necessary for the implant-tissue integration (osteointegration). Hence, in order to obtain successful implants which will inhibit bacterial adhesion and encourage osteointegration at the same time, further modifications are required. We will focus on this challenge in our following studies by modifying PEO with osteoblast-specific biosignal molecules.