1 Introduction

Gravel or cobble mixtures are commonly encountered in geotechnical projects, such as slopes, foundations, and tunnels [1, 2]. For stability analysis, it is critical to determine the shear strength parameters of the materials, namely, cohesion and friction angle.

The direct shear test was first used by Coulomb in 1991 [3], and it has been widely used to estimate the strength parameters of soils. Although the direct shear test has limitations compared to the tri-axial test, it is still prevalent in practise [4,5,6,7]. This method has been included in test standards in almost every country [8, 9]. The scale of the shear box must be large enough compared to the size of the soil particles to obtain reliable shear behaviour [10]. The Department of Transport and Main Roads, Queensland, suggested that the shear box should be no less than 300 mm in width or ten times the maximum particle size for coarse-grained granular materials. After consolidation, the sample thickness should not be less than 120 mm or six times the maximum particle size [11]. The testing of coarse soils for shear strength could be problematic, particularly for cobbles with more than 20 larger sized particles because most laboratory testing equipment is used for small-sized samples (relative to the size of soil particles) [12]. Researchers have used a large shear box in the laboratory to study the interface shear strength of sub-ballast reinforced with different types of geomembranes and geogrids [13]. The remoulded frozen soil samples under frozen, transition, freeze–thaw conditions were analysed [14], and large-scale cyclic simple shear tests and post-cyclic monotonic simple shear tests were performed on the gravelly soils [15].

In many cases, it is not practical or possible to use such large nondisturbed samples in the laboratory for testing, especially for noncohesive materials [16]. An in situ direct shear test was performed by horizontally pulling a latticed shearing frame embedded in the ground under a constant vertical load on the sample [17]. The method has been used successfully for testing rockfills, sands, and clays. A case study used the simplified large in situ direct shear test to determine the shear strength of roller compacted rockfills. The shear strength of roller compacted rockfill could be derived directly using the Mohr–Coulomb criterion [18]. A large-scale direct shear test of a soil–rock mixture was performed, and a digital image process was used to obtain the proportion and distribution of the rock blocks [19]. The ratio of rock particles controlled the deformation and fracture mechanism of soil–rock mixtures.

During the construction of subways in Luoyang city, deep excavations were needed for the subway stations. Sandy gravels with cobbles were encountered during the process. Six large in situ direct shear tests were carried out at one of the sites to determine the shear strength parameters of the sandy gravel with cobble. The test method followed the recommended guidelines in the Chinese Code, and this method is also commonly used to measure in situ rock strength according to ASTM. Through the analysis of the test results, the friction angle obtained via shear tests was nearly half that obtained via empirical methods and reported in the literature. To explain why the in situ direct shear test underestimates the strength of the soil, a finite difference analysis was performed to simulate the in situ shear tests and a test on a rock sample from the literature for comparison. The comparison shows that the failure of the sandy gravel with cobbles used in the test method did not follow the failure mode indicated in the Chinese Code or that of rocks. Instead, the failure of the sandy gravel at the site was caused by bearing-capacity failure rather than direct shear failure. The Meyerhof bearing-capacity theory [20] was used to back analyse the friction angle of the soil.

2 Description of Site

The test site is located in Luoyang, which is approximately 50 km south of the Yellow River, as shown in Fig. 1. Alluvial-diluvial plains formed during historic flooding of the rivers, with a thick layer of alluvial materials. The terrain is relatively flat, and the natural ground surface is between 146.7 m and 148.2 m above sea level. As part of the Luoyang subway Line 1 project, one pit was excavated for the Control Centre Subway Station. The geological profile of the site is shown in Fig. 2. A thick (~ 20 m) layer of sandy gravel with cobble was found approximately 6 m below the ground surface. The pit was approximately 10 m deep below the ground surface. The base of the excavation was located in this layer. Therefore, the sandy gravel layer had a great impact on excavation performance. The water table at the site was approximately 22 m below the ground surface, which was well below the depth of concern.

Fig. 1
figure 1

Location of in situ test

Fig. 2
figure 2

Ground profile of the site

Several large-scale direct shear tests and dynamic cone penetration (DCP) tests were performed at the site to determine the shear strength parameters of the sandy gravel at the base of the pit. Six in situ shear tests were performed in the sandy gravel layer, 10 m below the ground surface, at the base of the excavation, as shown in Fig. 2. The soil to be tested was brown and grey in colour. The in situ density of the soil was 2200 kg/m3, indicating that the soil was in a moderately dense to dense state. The cobbles were rounded and consisted mainly of limestone, sandstone, and quartzite, as shown in Fig. 3. The particle size distributions of the six sheared samples are shown in Fig. 4. Some variation could be observed in the particle grading of the samples. Most samples contained approximately 15 to 40% cobble. The grading parameters are listed in Table 1. The soil can be classified as sandy gravel with cobbles [21]. The moisture content of the soils at the test sites ranged from 3.04 to 5.78%, with an average value of 3.92%. DCP was performed at the site using a 74 mm diameter cone with a 60° cone tip, driven by a 120 kg hammer with a free fall height of 100 cm. The results showed that for 10 cm of penetration, the corrected number of drops was N120 = 22.9.

Fig. 3
figure 3

Exposure of in situ soil columns

Fig. 4
figure 4

Particle size distributions of the soil samples

Table 1 Grading properties of the soils at the shear test site

3 In Situ Direct Shear Test Procedure

In situ direct shear tests were performed per the specifications for field shear tests commonly used in China [22]. A diagram of the setup is shown in Fig. 5. Unlike normal shear box setups, which include a top and a bottom shear box, the setup in situ has only one shear box made of a 0.5 m cubic-shaped hollow steel column to provide confinement to the soil. The lower part of the soil is confined by the foundation soil, as shown in Fig. 5. A vertical load is applied on the top surface of the soil column confined in the steel column via a loading plate, and the column is sheared laterally to measure the resistance of the soil. This setup is similar to that used for in situ tests of rocks [23].

Fig. 5
figure 5

Diagram of the test setup

To form one soil sample, a 2.5 m long × 3 m wide × 0.8 m deep test pit was excavated at the base of the excavation to form a soil column (1 m long × 1 m wide × 0.8 m tall) at the centre of the test pit. The soil column was carefully shaped to fit into the steel column. The top surface of the soil column was flattened, and the voids were filled with fine sand to ensure the even distribution of loading from the load plate. Loading was applied via two square steel plates with a thickness of 3 cm and a width of 49 cm wide; these steel plates were placed on the soil surface, with eight roller steel bars (49 cm long, 3 cm diameter) sandwiched between the two plates.

A 2 m long × 0.5 m wide × 0.8 m high concrete beam was placed on one side of the pit as the reaction beam for horizontal loading. A 3 cm thick steel plate (70 cm × 50 cm) was fixed on the inner side of the beam as the footing of the lateral loading jack. Steel beams and concrete blocks were used to provide reaction forces for vertical loading. Four linear variable displacement transducers (LVDTs) were installed on the four corners of the loading plate, and four LVDTs were installed on the other side of the shear box to measure vertical and lateral movement, respectively. Figure 6 shows photos of the test system. The vertical and lateral loadings were applied using hydraulic jacks. The tests used six vertical loading levels: 12.5 kN, 25 kN, 50 kN, 75 kN, 100 kN, and 150 kN. The vertical and horizontal loadings were applied as per Chinese Standard recommendations [24].

Fig. 6
figure 6

Test setup for the in situ large-scale direct shear test

4 Test Results and Discussion

Figure 7 shows the load–displacement curves of the samples under shear. The positive displacements in Fig. 7b indicate downwards movement. The shear displacement curves of the samples show that the samples behave similarly to those of medium-density sand. The nearly linear relationship between the normal stress and shear stress at failure shown in Fig. 8 indicates that the friction angle (\(\phi\)) of the soil is approximately 26.7° (assuming that the cohesion is zero), as calculated using Eq. (1):

$$\tan \phi = \tau /\sigma = F/N$$
(1)

where σ is the normal stress, τ is the shear stress, N is the vertical load, and F is the horizontal load.

Fig. 7
figure 7

Shear displacement curve. a Horizontal displacement and b vertical displacement

Fig. 8
figure 8

Normal stress vs. shear stress curve

The strength parameters of the gravel can also be estimated based on the DCP results. N120 is used to calculate N63.5 (the number of drops for 63.5 kg of the hammer dropping from 76 cm high to penetrate 10 cm) [25, 26]:

$$N_{63.5} = 3N_{120} - 0.5$$
(2)

This gives N63.5 = 68.2 using N120 = 22.9. The friction angle of the material should be greater than 48°; this value is much greater than the value obtained based on in situ direct shear tests [27].

Carter suggested that the friction angle of well-graded sand-gravel mixtures should be greater than 38° [28]. The friction angle of soils can be obtained using the following empirical formula [29]:

$$\phi = 36 + \phi_{1} + \phi_{2} + \phi_{3} + \phi_{4}$$
(3)

where \(\phi_{1}\), \(\phi_{2}\), \(\phi_{3}\), and \(\phi_{4}\) are empirical parameters affected by the soil type, relative density, soil gradation, and particle shape, respectively. Based on the characteristics of the soil tested at the site, 1° (gravel + sand), 6°( very dense, 0°( medium), and − 3° (subrounded) were used for \(\phi_{1}\), \(\phi_{2}\), \(\phi_{3}\), and \(\phi_{4}\), respectively, in the test soil [29]. According to this method, the friction angle of the soil at the site should be 40°; this value is also much greater than that obtained from Fig. 8.

5 Failure Mechanism Analysis Using the Finite Difference Method

The above discussion indicates that the applicability of the in situ direct shear test can be problematic in certain scenarios. For some in situ tests, the shear force location may generate momentum along the shear surface [17, 30,31,32]. Additionally, due to the lack of a bottom shear box, the shear surface may not follow the predefined conditions at the interface of the upper and lower shear boxes used in normal shear tests. However, Eq. (1) is used in practise, as recommended in the Chinese Code [24].

Finite difference analyses were performed using a finite difference method in FLAC3D (FLAC3D, 2018) to study the discrepancy between the friction angles obtained from the empirical methods and the direct shear test results. Considering the symmetrical nature of the shear box, a half model was built for the numerical analysis, as shown in Fig. 9. In the figure, L is the width of the shear box, which is 0.5 m, and H is the height of the shear box. The ground is surrounded by horizontal constraints on three sides except for the right face for the symmetry boundary, whilst the shear box experiences vertical constraints at its base. The size of the shear box was 0.5 m × 0.5 m × 0.35 m, and the box was modelled as rigid walls. A total of 122,040 elements were generated in the model. A friction angle of 48° was assumed for the soil with a cohesion of 1 kPa to avoid numerical instability. Four in situ direct shear tests were simulated with the finite difference model, except for the case with 200 kPa of normal loading, where the horizontal load–displacement behaviour was clearly abnormal. The Young's modulus of the soil was calculated using E = 25(p/pa)0.5 MPa as recommended by Jiang et al. [33] and Oztoprak and Bolton [34]; here, p is the normal loading applied and pa is the atmospheric pressure of 100 kPa. The dilation angle was assumed to be 19° and calculated using the method recommended by Bolton [35] for sand with a postulated critical state friction angle of 33°.

Fig. 9
figure 9

Finite difference model (half model) of the in situ shear tests

For comparison, a test on a rock sample [36] was also simulated to compare the applicability of in situ rock test methods [23] to rock samples. Considering the symmetry of the model, to enhance computational efficiency, only half of the model was constructed and analysed, with a symmetry boundary set at the centre of the model. The ground was 10 L (L is the length of the sample) in length and 5 L in width and depth. The ground was surrounded by horizontal constraints on three sides except for the right face for the symmetry boundary, and the ground experienced vertical constraints at its base. A test under a normal load of 433 kPa was modelled. The cohesion and friction angle of the rock obtained from the shear tests were 423 kPa and 52°, respectively [36]. The values were used in the numerical modelling with an assumed Young's modulus of 600 MPa and a Poisson's ratio of 0.25. Mohr–Coulomb failure criteria were used for both the soil and the rock in the analyses.

Figures 10 and 11 compare the shear displacement curves of the soil and the rock obtained from in situ tests with those from the numerical analyses. With the assumed soil friction angle, which is almost twice that of the value calculated with Eq. (1), the results from the numerical analysis compare quite well with the in situ test results. This indicates that Eq. (1) cannot be used to obtain soil shear strength parameters with the test method used at the site but is suitable for the rock tested [36].

Fig. 10
figure 10

Shear displacement curve of sandy gravel with cobbles obtained via in situ tests and numerical modelling

Fig. 11
figure 11

Shear displacement curve of the rock specimens tested by Xing et al. [36]

To further explain the discrepancy between the performance of the test on rock and soil, the failure plane observed in the numerical simulations is presented in Fig. 12. For the rock sample, the shear plane is along the base of the shear box (Fig. 12b). For the soil sample, the shear failure (Fig. 12a) occurs deep in the ground rather than along the base of the shear box. The shear surface in the soil is similar to that of bearing-capacity failures of shallow foundations [37]; this type of failure is different from the shear failure mechanism observed in soil cracking box direct shear tests and rock in situ shear tests [23]. Therefore, the friction angle obtained using Eq. (1) would be lower than expected since the incorrect failure mechanism was used.

Fig. 12
figure 12

Shear strain contours on the plane of symmetry for direct shear tests on (a) sandy gravel with cobbles sample and (b) rock reported in Xing et al.

6 Back Analysis Using the Meyerhof Equation

Based on the previous numerical analysis, the shear box enclosed soil can be considered a shallow foundation under an inclined load. Therefore, the failure of the shear tests performed at the site is a bearing-capacity failure rather than a direct shear failure. There are many methods available for calculating the bearing capacity of shallow foundations under inclined loads [20, 38, 39], and the following equation is used to back analyse the friction of the soil tested at the site:

$$q_{{{\text{ult}}}} = cN_{c} d_{c} i_{c} + \overline{q}N_{q} d_{q} i_{q} + 0.5\gamma B^{\prime}N_{\gamma } d_{\gamma } i_{\gamma }$$
(4)

where the following terms are defined as follows:

$$N_{q} = e^{\pi \tan \phi } \tan^{2} \left( {45 + \frac{\phi }{2}} \right)$$
(5)
$$N_{c} = \left( {N_{q} - 1} \right)\cot \phi$$
(6)
$$N_{\gamma } = \left( {N_{q} - 1} \right)\tan \left( {1.4\phi } \right)$$
(7)

As the shear box is square shaped and sitting on the ground surface, the shape factors (sc, sq, sγ), depth factors (dc, dq, dγ), and inclination factors (ic, iq, iγ) can be derived using the following [20, 40]:

$$s_{c} = 1 + 0.2\tan^{2} \left( {45 + \phi /2} \right)$$
(8)
$$s_{q} = s_{\gamma } = 1 + 0.1\tan^{2} \left( {45 + \phi /2} \right){\text{ for }}\phi { > 10}^{{\text{o}}}$$
(9)
$$d_{c} = d_{q} = d_{\gamma } = 1$$
(10)
$$i_{c} = i_{q} = \left( {1 - \frac{{\theta^{{\text{o}}} }}{{90^{{\text{o}}} }}} \right)^{2} ;\;\quad i_{\gamma } = \left( {1 - \frac{{\theta^{{\text{o}}} }}{{\phi^{{\text{o}}} }}} \right)^{2}$$
(11)

where \(\theta\) is the angle between vertical and horizontal loading and B is the footing width and is considered to be 0.5 m. Under inclined loading, the effective footing width B′ can be derived as follows [40]:

$$B^{\prime} = B - 2\frac{F \cdot h}{N}$$
(12)

In this test, the shear force is applied at 0.1 m above the ground, and h = 0.1 m; hence, the following is obtained:

$$B^{\prime} = B - 0.2\frac{F}{N}{ = }B - 0.2\tan \left( \theta \right)$$
(13)

In the back analysis for this in situ test, the cohesion c and foundation depth were set to zero, the width and length of the plate were both 0.5 m, and the weight of the sandy gravel with cobbles was 22 kN/m3. The variation in F/N with N for different soil friction angles is plotted in Fig. 13, along with the in situ shear test results. Based on the bearing-capacity theory, the friction angle of the soil was within the range of 42° to 47.5°, which was close to the values obtained from the empirical methods, DCP tests, and the value used in the finite difference analysis discussed earlier. This again confirmed that the test results obtained from the shear tests could not be analysed directly using the direct shear theory described in Eq. 1. Therefore, back analysis is recommended using the bearing-capacity theory of shallow foundations to obtain the shear strength of the soil.

Fig. 13
figure 13

F/N vs. normal stress obtained from Meyerhof bearing-capacity theory

7 Conclusion

A set of large-scale single box (50 cm cubic shear box) direct shear tests were performed on sandy gravel with cobbles at the base of an excavation at a metro station. The main conclusions were as follows:

Because the bottom boundary condition was not fixed during the in situ test, the friction angle of sandy gravel with cobbles obtained (26.9°) through the in situ direct shear test was much lower than the values (> 40°) obtained through empirical equations and the value (48°) derived from in situ DCPs and finite difference analysis.

Compared with the rock direct shear test, the failure of the sandy gravel with cobbles during the in situ direct shear test did not occur along the base of the shear box, as observed in the rock sample, but it did occur at the bottom of the sample due to the bearing-capacity failure.

The test results were back-analysed using the Meyerhof bearing-capacity equation. The analysis indicated that the direct shear test results obtained at the site could not be analysed using the direct shear failure mechanism without a fixed bottom. Therefore, back analysis using bearing-capacity theory is recommended for obtaining the soil strength parameters when a single box large shear test is performed on this type of soil.