Abstract
Background
Electrical isolation of pulmonary vein ostia is an established therapy for paroxysmal atrial fibrillation.
Aims
The purpose of this study is to evaluate the long-term efficacy and safety of cryoballoon catheter ablation in paroxysmal atrial fibrillation with normal anatomy of the left atrium.
Methods
Two hundred fifteen consecutive patients were included in the study (from November 2014 to November 2016). All the patients had symptoms of paroxysmal atrial fibrillation resistant to antiarrhythmic drugs and underwent pulmonary vein cryoisolation using second-generation cryoballoons. Standard “single-shot” cryoballoon exposures were used alternately for each of the four pulmonary veins. The endpoint of the ablation procedure was the electrical isolation of each pulmonary vein.
Results
Sixty-nine patients had stable atrial fibrillation recurrences and left atrial flutter with 30 of 69 patients having atrial fibrillation paroxysms during the first year after primary ablation. Repeated ablation was performed within 6–12 months after the first ablation. In 39 of 69 cases, arrhythmia recurrences were registered during the second and third year after the first ablation. These patients underwent repeated ablation within 12–36 months after the first ablation. In 98% of the patients, no disease progression with a transition to a persistent form of atrial fibrillation was observed. During the mean 5-year follow-up period, no disease progression with the transition to persistent forms of atrial fibrillation was observed.
Conclusions
It was concluded that in patients with paroxysmal atrial fibrillation, with normal left atrium anatomy and no risk factors, it can be controlled with single pulmonary vein isolation without additional atrial substrate modification.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
The relevance of this paper is due to the fact that atrial fibrillation (AF) is the most common cardiac arrhythmia, and paroxysmal AF naturally progresses to persistent AF with a risk of thromboembolic complications. In the late 90s, a concept of the elimination of AF triggering factors, the so-called ectopic foci in the pulmonary vein (PV) ostia, using radiofrequency ablation (RFA) was proposed which, together with new methods of linear RFA in the left atrium (LA), can treat paroxysmal and persistent forms of AF most effectively [1,2,3,4].
A large number of randomized trials demonstrated the advantages of catheter ablation compared with pharmacotherapy in maintaining sinus rhythm in AF, with no arrhythmia recurrences in 65–85% of patients [5, 6]. However, the use of RF energy may cause some undesirable consequences: thrombogenicity, formation of heterogeneous damages in the LA wall and PV ostia, high penetration of RF energy, LA wall perforation, post-ablative incisional tachycardia, atrioesophageal fistula, and PV stenosis [7]. Moreover, catheter RFA in the LA based on sequential, point-by-point applications to create a continuous lesion line is a complicated and time-consuming procedure [8, 9].
Over the last years, cryotechnologies using low temperatures for catheter ablation in cardiac arrhythmias have been actively implemented. Catheter ablation using a cryoballoon is one of them. Its purpose is to achieve electrical PV isolation using a single application. Due to the use of an inflated balloon, which is completely adjacent to the PV ostia, this technique simplifies the manipulations in the LA and allows a simultaneous, circular PV isolation [10]. This technique uses tissue freezing to create circular damage in the PV ostia. Intracellular ice formation with its subsequent thawing forms a reliable, and most importantly, safer damage compared with radio frequency exposure [11].
The purpose of this study is to evaluate the long-term efficacy and safety of cryoballoon catheter ablation in paroxysmal AF with normal anatomy of the left atrium.
Materials and methods
In the National Scientific Center of Surgery named after A.N. Syzganov, invasive electrophysiological studies (EPS) and 215 primary cryoballoon ablation procedures were performed in 215 consecutive patients with paroxysmal AF resistant to antiarrhythmic therapy (including cordarone) from November 2014 to November 2016. Patients’ age ranged from 29 to 78 years, mean 53.5 ± 24.5 years (Table 1). The patients with hyperthyroidism did not enroll in this study. AF was classified as paroxysmal if the episodes stopped spontaneously within less than 7 days, according to the HRS/EHRA/ECAS Consensus Statement of 2012 on AF catheter and surgical ablation [12]. All patients gave their written informed consent. All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The study design was approved by National Ethics Commission of the Ministry of Health of the Republic of Kazakhstan November 19, 2019, No O-9875-6.
Preparation for the intervention
Antiarrhythmic drugs (mean 3 ± 1.5 antiarrhythmic drugs per patient) were stopped 48–72 h before EPS (cordarone was stopped 45 days before the procedure). All patients underwent preoperative trans-esophageal echocardiography (TEE) to exclude blood clots in the left atrial appendage (LAA). Multispiral computed tomography (MSCT) was performed in 85% of the patients to study LA topographic anatomy and determine LA size (Fig. 1). All patients received anticoagulants (warfarin, Xarelto) with the international normalized ratio (INR) monitoring (2.0–3.0) for 4 weeks before surgery and 3 months thereafter. Using two-dimensional transthoracic echocardiography (2D-TTE), the degree of severity of valve regurgitation was differentiated from insignificant physiological in normal valvular anatomy and mobility of the valves to severe in the presence of a significant valvular defect.
Cryoballoon ablation procedure
In all patients subjected to ablation, the pulmonary veins were isolated during a single procedure. In 208 (97%) patients, 3 or more PVs were isolated, which was confirmed by the input and/or output block. All 4 main PVs were isolated in 198 (92%) patients, as well as 12 of 12 left common veins (collectors). All patients underwent cryoballoon ablation only, and it was sufficient for complete isolation; only 6 ± 2 applications were required for all PVs. Mean cryoballoon application time was 225 ± 15 s. Mean cryoablation temperature was −49.6 ± 4.2 °C. Four patients required additional ablation at one or more PV ostia; at 19 PV ostia, where isolation could not be achieved with one application, mean 2.2 cryoablations were performed. Twenty-eight-millimeter balloons were used in all patients. Mean duration of the procedure, including all repeated PV evaluations, was 141.1 ± 13.9 min; mean fluoroscopy time was 27.2 ± 9.6 min and mean total cryoablation time was 42.3 ± 9.9 min. Time data of procedures are indicated in Table 2. Ablation in the cavotricuspid isthmus was performed in 19 (38%) patients and bidirectional blockade was achieved in 17 (90%) cases.
During the ablation procedure, the patients received a single dose of heparin, calculated as 100 units per 1 kg of body weight, to achieve the activated coagulation time (ACT) > 300 s, then fractionally, to maintain this ACT level. Sedation and/or anesthesia and anticoagulant discontinuation were according to the standards of care. Before discharge, the patients after ablation underwent control x-ray examinations at inhalation and exhalation to detect the phrenic nerve palsy. Anticoagulant prophylaxis was carried out over the first 6 months after ablation. Subsequently, anticoagulants were replaced with aspirin if there were no indications according to the CHA2DS2-VASc risk stratification. During a 90-day “blanking” period, the patients also received 1 or 2 antiarrhythmic drugs as prophylaxis with its further discontinuation. One cardioversion and one ablation were allowed during this “blanking” period, as recommended.
Follow-up
The patients were followed-up with constant ECG monitoring in the hospital for 3 days after the procedure. The first visit to the clinic was 4 weeks after the procedure. Subsequent visits consisted of a clinical interview, ECG, and a 24-h Holter monitoring at 3, 6, 9, and 12 months in the clinic, in addition to a routine follow-up by an independent physician. The patients then visited the clinic every 6 months. An unscheduled 24-h ECG monitoring was performed if any symptoms occur. This study was conducted at each visit to the clinic. Antiarrhythmic drugs were not prescribed after the procedure but were allowed in the patients with symptoms of atrial extrasystoles and tachycardia. If any symptoms suggesting arrhythmia occurred, the patients were asked to visit the clinic, and a 12-lead ECG or 24-h Holter monitoring and/or event recording were performed for 1 month to determine the cause of the symptoms. All patients were personally informed of the follow-up. Anticoagulants were discontinued 3 months after the procedure if they were not indicated according to the CHA2DS2VASc. Success was defined, with or without antiarrhythmics, as the absence of all documented arrhythmias lasting more than 30 s or symptoms indicating arrhythmia recurrence. A repeat procedure was strongly recommended for the patients with documented recurrences of atrial tachyarrhythmias.
Results and discussion
The results of continuous variables are presented as arithmetic means ± standard deviation. The mean values were compared using the Mann-Whitney U test depending on the value distribution. Categorical variables were compared using the exact binomial or chi-square analysis. The long-term results were presented using the Kaplan-Meier curve, where the significance of differences was presented using a log-rank test. The differences between the groups were also identified using the proportional risk models. The primary efficacy endpoint was assessed using the double-sided Fisher’s exact test for binomial proportions. This test is useful for categorical data that result from classifying objects in two different ways. The Fisher’s test is used to examine the significance of the association (contingency) between the two kinds of classification. It is one of a class of exact tests because the significance of the deviation from a null hypothesis (P value) can be calculated exactly, rather than relying on an approximation that becomes exact in the limit as the sample size grows to infinity. Statistical analysis was performed using the IBM SPSS Statistics-19 software.
Ablation procedure
Data on cryoballoon ablation procedures for patients are shown in Table 3. The left common collector was identified in 17 patients (7.9%). Arrhythmogenic PVs were detected during the procedure in 145 patients (67%); LSPV in 40, LIPV in 33, left common collector in 5, right superior pulmonary vein (PV) in 35, right inferior PV in 5, and no PV in 15 patients. Cryoablation duration was 240 s; at the end of the application, the supply of the freezing agent was stopped, and the balloon was blown off. When the temperature exceeded –60°C, the freezing flow was stopped; the flow was resumed until the total time of 240 s in one vein was reached. The sequence of PV cryoablation was as follows: first, the left superior PV (LSPV), then the left inferior PV (LIPV). After the left PVs, the right PVs were treated. Ablation was started with the RIPV, after its complete isolation, the right superior PV (RSPV) was treated, as the phrenic nerve palsy (PNP), as many studies and personal experience have shown, mainly occurs with cryoablation of the RSPV. An example of LSPV cryoballoon ablation is shown in Fig. 2. Therefore, cryoapplication was carried out last in the RSPV. In our study, we observed it in 15 patients, and of them, only in one case the PNP occurred during cryoablation of the RIPV. During ablation of the right PVs, a 4-pole diagnostic electrode was guided from the right ventricle to the superior vena cava, and the right phrenic nerve was passed (12 mA, 2–3 ms) with a frequency of 15 pulses/min. After cryoablation of all PVs, an attempt was made to induce AF using frequent and super-frequent atrial pacing.
Arrhythmia recurrences were observed during the first year following the first ablation in 30 of 69 patients, and arrhythmias were recorded during the following years in the remaining 39 patients. The number of recurrences by year is shown in Fig. 3. The types of recurrent arrhythmias included AF and atrial flutter in 23 and 7 patients with early re-ablation, respectively. The following ablation procedures were performed in 27 patients with AF and in 12 patients with left atrial flutter. In 17 of 23 patients with AF, a restored PV conductivity was observed. Conductivity gaps were located along the right PVs in 6 patients and along the left PVs in the remaining 11 patients. In later re-ablation, PV reconnection in the right PVs was observed in 10 patients and the left PVs in 17 patients with AF.
In general, PV isolation was performed in 206 of 215 patients (95.8%). In 9 of 215 patients (4.2%), additional cryoballoon ablations were performed to relieve macro-recurrent atrial tachycardia. Bidirectional linear blocks in the CTI were created in 72 patients (33.5%). During the median follow-up period of 4.2 years (25–75th percentile, 3–5 years), 146 patients (68%) were free of arrhythmias. Sixty-three patients of 146 received antiarrhythmic drugs. In a univariate analysis, AF duration was significantly longer in the patients with arrhythmia recurrences compared with the patients without the latter procedure (P = 0.01). None of the patients showed progression with a transition to persistent AF after ablation.
Periprocedural complications
Among 284 procedures, the major complications occurred in 16 (5.6%) patients. Cardiac tamponade was observed in 1 patient (0.4%), who was treated using percutaneous pericardiocentesis without complications. Three patients (1.1%) developed hematomas at the groin site puncture. All complications were treated conditionally.
Phrenic nerve palsy was assessed using the chest x-ray during inspiration/expiration after all cryoablation procedures. PNP was recorded in 12 patients (5.6%), and all of them were asymptomatic; in 2 patients, PNP resolved by the end of the procedure; palsy persisted for 1 week in one patient. Full radiographic recovery of PNP in the fourth patient occurred after 4 months of follow-up. All cases of the PNP were recorded during RSPV ablation.
Long-term outcomes
The primary efficacy endpoint was evaluated using the analysis of the time to the first event, after a 90-day “blanking” period (during which arrhythmia recurrence was not taken into account according to the primary endpoint) of the following failure events: (1) documented episodes of AF for more than 30 s, atrial tachycardia or atrial flutter; (2) administration of antiarrhythmic drugs to restore sinus rhythm; and (3) repeated catheter ablation. When assessing primary efficacy during the median follow-up period of 4.2 years (25–75th percentile, 3–5 years), 146 patients (68%) were free of arrhythmias (Fig. 4). The absolute number of patients who reached the primary safety endpoint was 16 (5.6%) patients.
Atrial flutter or atrial tachycardia after cryoballoon ablation in AF was recorded, and it is assumed that they were created (partially) by incomplete damages or gaps in the AF ablation lines, which turn into a new substrate for the reentry mechanism. For this reason, the occurrence of atrial flutter and atrial tachycardia were also included as severe adverse events.
At the end of 12 months, only 33.5% of the patients received antiarrhythmic drugs; 56% of the patients received warfarin, and 54% received Xarelto 20 mg at admission, and only 24% of the patients continued this treatment after 12 months of follow-up. The CHA2DS2-VASc score did not differ between those who stopped and those who continued anticoagulants. The rate of AF clinical symptoms decreased from 100% at the beginning of the study to 19.0% over 36 months. The symptoms associated with arrhythmia were dramatically reduced after 12 months of follow-up: AF symptoms (from 100 to 20%), dizziness (from 48 to 9%), palpitations (from 86 to 12%), and fatigue (from 76 to 13%). These clinical improvements were confirmed by an increase in the quality of life according to the SF-36.
This data shows that (1) the vast majority of drug-resistant symptomatic paroxysmal AFs can be controlled with cryoballoon isolation of the PV ostia without additional atrial substrate modification during the mean follow-up of 5 years, and (2) a stable recurrence rate of atrial tachycardia paroxysms is observed, but there is no progression with a transition to a stable form of AF during a long-term follow-up after cryoballoon ablation.
According to the results of large studies with the largest number of patients included, a complete absence of persistent atrial rhythm disorders is observed in 59–77% of cases [13, 14]. Significant variations in the efficacy of cryoablation in these studies may be due to the differences in ablation protocols, different balloon diameters, differences in the methods used to detect arrhythmia recurrences, presence or absence of a “blanking” 3-month follow-up period after ablation, and differences in the evaluation of antiarrhythmic therapy in ablation efficacy.
Recent studies, like “Fire and Ice,” compared the efficacy of cryoballoon PV isolation and radiofrequency catheter PV isolation. In this large-scale randomized study, which included 769 patients from 16 medical centers throughout Europe, there were no statistically significant differences in ablation outcomes (no arrhythmias in 88 and 92% after 1.2 procedures with a follow-up of 33 months) [15]. During the study, the primary efficacy endpoint was achieved—it was proven that the Arctic Front cryoballoon ablation catheters without three-dimensional mapping technology are not inferior to the ThermoCool radiofrequency ablation catheters with three-dimensional mapping technology (p = 0.0004) in terms of the reduction of arrhythmia recurrence rates or the need in antiarrhythmic pharmacotherapy and/or repeated ablation. The primary safety endpoint was also achieved, i.e., time to the first death for any reason, stroke or TIA (transient ischemic attack) for any reason, or to serious adverse events associated with treatment (p = 0.24). Both technologies showed comparable low complication rates.
According to the results of the study, cryoballoon ablation technology provides a shorter duration of the procedure (mean time = 124 min) compared with radiofrequency ablation (mean time = 141 min; p = 0.0001). The studies showed that the restoration of electrical conductivity from the PV to the LA is the main factor in AF recurrences following catheter ablation [16]. Thirty minutes after cryoablation, 97.2% of the PVs remain electrically isolated [17], 56–84 days after, 88% of the PVs and 144 days after 46% of the PVs. Most often, the restoration of electrical conductivity is observed in the lower PV segments and between the PV ostia and the left PV. Damage during cryoablation, in contrast to traditional radiofrequency exposure, is characterized by a clearly defined line of necrosis, homogeneity of the necrosis area, preservation of the endocardial layer, and the absence of thrombosis at the site of exposure [18, 19].
One study showed that the diameter of cryothermal damage is directly proportional to the size of the ablation electrode; however, the depth of damage remains unchanged [20, 21]. The only frequent complication of PV cryoablation is the right phrenic nerve palsy (PNP), which develops in 1.7–12% of patients [22,23,24,25]. This complication is associated with the close attachment of the right phrenic nerve to the anterior wall of the right superior PV. When a deeper placement of the balloon in the PV, the risk of the phrenic nerve palsy increases. Practice shows that the use of a larger diameter balloon (28 mm) and control of diaphragm contractions during ablation (pacing from the superior vena cava) can reduce the risk of this complication. Nerve function is restored in 1–12 months in all patients. In this study, we observed PN palsy in 12 (5.6%) of 215 patients. PN function in 8 patients recovered within 3 days to 1 month, in 3 patients within 3–6 months of follow-up, and one patient recovered after 12 months only. Such complications associated with traditional radiofrequency PV ablation, such as PV stenosis, damage to the esophageal wall and the formation of the atrioesophageal fistula, incisional tachycardia due to the areas of delayed conduction around the treated area [26, 27], are almost absent in cryoballoon ablation [28, 29].
Conclusions
The results of the study clearly emphasize the importance of a close long-term follow-up after catheter ablation to detect very late arrhythmia recurrences. This study shows that the vast majority of AFs can be controlled by creating a long-term reliable electrical isolation of the antral PV segments and eliminating the non-PV triggers. However, even after several procedures, some patients had no arrhythmias. In some patients, it was not difficult to identify the AF trigger using various cryoballoon maneuvers and eliminate all of the multiple AF triggers during the procedure. The development of a new technology may be necessary to improve clinical outcomes in these patients. In patients with a paroxysmal form of atrial fibrillation, with normal anatomy of the left atrium in the absence of risk factors, the control is possible using a single isolation of the PV ostia without additional modification of the atrial substrate.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Change history
12 July 2023
This article has been retracted. Please see the Retraction Notice for more detail: https://doi.org/10.1007/s11845-023-03458-8
References
Miyasaka Y, Barnes ME, Gersh BJ et al (2006) Secular trends in incidence of atrial fibrillation in Olmsted County, Minnesota, 1980 to 2000, and implications on the projections for future prevalence. Circul 114(2):119–125
Saksena S, Hettrick DA, Koehler JL et al (2007) Progression of paroxysmal atrial fibrillation to persistent atrial fibrillation in patients with bradyarrhythmias. Americ Heart J 154:884–892
Haïssaguerre M, Jaïs P, Shah DC (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. New Eng J of Med 339:659–666
Haissaguerre M, Jais P, Shah D et al (2000) Electrophysiological endpoint for catheter ablation of AF initiated from multiple pulmonary venous foci. Circul 101:1409–1417
Revishvili A, Rzaev F, Sopov O, Labazanova AL (2012) Long-term results of interventional treatment of atrial fibrillation. J of Arrhyth 68:5–13
Katritsis DG, Pokushalov E, Romanov A et al (2013) Autonomic denervation added to pulmonary vein isolation for paroxysmal atrial fibrillation: a randomized clinical trial. J of the Americ Coll of Cardiol 62:2318–2325
Verma A, Jiang C, Betts TR (2015) Approaches to catheter ablation for persistent atrial fibrillation. New Eng J of Med 372:1812–1822
Wu L, Yao Y, Zheng L et al (2014) Long-term follow-up of pure linear ablation for persistent atrial fibrillation without circumferential pulmonary vein isolation. J of Cardiovasc Electroph 25:471–476
Ouyang F, Tilz R, Chun J (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circul 122:2368–2377
Su W, Aryana A, Passman R et al (2018) Cryoballoon best practices II: practical guide to procedural monitoring and dosing during atrial fibrillation ablation from the perspective of experienced users. Heart Rhyth 15:1348–1355
Kuck KH, Brugada J, Furnkranz A (2016) Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. New Eng J of Med 374:2235–2245
Calkins H, Kuck KH, Cappato R (2012) 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Heart Rhyth 9:632–696
Baimbetov A, Bizhanov K, Bairamov B et al (2018) Immediate results of pulmonary veins cryoablation in patients with atrial fibrillation. Zeitsch für Gefäß 12(1):64–71
Pokushalov E, Romanov A, Artyomenko S et al (2013) Cryoballoon versus radiofrequency for pulmonary vein re-isolation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation. J of Cardiovasc Electrophys 24:274–279
Kuck KH, Fürnkranz A, Chun KR (2016) Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trial. Europ Heart J 7(37(38)):2858–2865
Lellouche N, Jais P, Nault I et al (2008) Early recurrences after atrial fibrillation ablation: prognostic value and effect of early reablation. J of Cardiovasc Electrophys 19:599–605
Narayan SM, Krummen DE, Donsky A (2013) Treatment of paroxysmal atrial fibrillation by targeted elimination of stable rotors and focal sources without pulmonary vein isolation: the precise rotor elimination without concomitant pulmonary vein isolation for subsequent elimination of PAF (PRECISE). Heart Rhyth 10:LB10
Heeger CH, Wissner E, Knöll M (2017) Three- year clinical outcome after 2nd-generation cryoballoon-based pulmonary vein isolation for the treatment of paroxysmal and persistent atrial fibrillation: a 2-center experience. Circulat J 81:974–980
Miller JM, Kalra V, Das MK et al (2017) Clinical benefit of ablating localized sources for human atrial fibrillation: The Indiana University FIRM Registry. J of the Americ Coll of Cardiol 69:1247–1256
Chun KRJ, Perrotta L, Bordignon S et al (2017) Complications in catheter ablation of atrial fibrillation in 3.000 consecutive procedures: balloon versus radiofrequency current ablation. J of the Americ Coll of Cardiol 3:154–161
Kuck KH, Albenque JP, Chun JK (2019) Repeat ablation for atrial fibrillation recurrence post cryoablation or radiofrequency ablation in the FIRE AND ICE trial. Circul: Arrhyth and Electrophys 12(6):e007247
Evonich R, Nori D, Haines D (2007) A randomized trial comparing effects of radiofrequency and cryoablation on the structural integrity of esophageal tissue. J of Cardiovasc Electrophys 19:77–83
Aryana A, Singh SM, Mugnai G et al (2016) Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis. J of Intervent Card Electrophys 47:341–348
Garvanski I, Simova I, Angelkov L (2019) Predictors of recurrence of AF in patients after radiofrequency ablation. Europ Cardiol Rev 14(3):165–168
Mujovic N, Marinkovic M, Markovic N (2017) Prediction of very late arrhythmia recurrence after radiofrequency catheter ablation of atrial fibrillation: The MB-LATER clinical score. Scient Rep 7:408–428
Martínez Urabayen U, Caballeros M, Soriano I et al (2020) Anatomic characteristics of the left atrium in subjects undergoing radiofrequency ablation for atrial fibrillation. Radiolog. https://doi.org/10.1016/j.rx.2020.03.003
Jia Z, Du X, Lu S et al (2019) Effect of mental health status on arrhythmia recurrence after catheter ablation of atrial fibrillation. Canad J of Cardiol 35(7):831–839. https://doi.org/10.1016/j.cjca.2019.02.007
Mugazov M, Turgunov Y, Kaliyeva D et al (2019) The role of presepsin in patients with acute surgical diseases. Open Acc Macedon J of Med Scien 7(8):1282–1286.
Zhanaidarova G, Arystan L, Nauryzov N et al (2020) The effect of ethanol on the fetal heart muscle. J of Glob Pharm Technol 12(6):501–510.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflicts of interest.
Additional information
This article has been retracted. Please see the retraction notice for more detail: https://doi.org/10.1007/s11845-023-03458-8"
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Baimbetov, A.K., Abzaliev, K.B., Jukenova, A.M. et al. RETRACTED ARTICLE: The efficacy and safety of cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation. Ir J Med Sci 191, 187–193 (2022). https://doi.org/10.1007/s11845-021-02560-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11845-021-02560-z