Introduction

The petrochemical industry plays an essential role in the economic development of a country. Many important industries, such as energy, agriculture, and transportation, rely heavily on the petrochemical industry (Tian et al. 2020). However, petrochemical plants consume large quantities of water and subsequently generate wastewater (Wang et al. 2014). Petrochemical wastewater is characterized by high pollutant load, low biodegradability, high salinity, and toxicity (Kumar et al. 2013). Petrochemical wastewater comprises both organic pollutants like phenols, aldehydes, and benzenes, as well as inorganic pollutants such as heavy metals and fluoride. Given the severe health risks associated with these highly toxic pollutants (Gopalakrishnan and Bharathiraja. 2022), petrochemical wastewater must be treated before being safely released into the environment.

Based on the size of the pollutant particles, the PCW (petrochemical wastewater) pollutants are categorized into suspended, colloidal, and dissolved fractions. Although the suspended and colloidal traces can be simply removed by physicochemical treatment (Tong et al. 2016), the dissolved organic matter (DOM) contains many difficult-to-degrade compounds, such as benzene, aldehydes, phenols, polycyclic aromatic hydrocarbons (PAHs), naphthenic acids, petroleum hydrocarbons, and N/O/S-containing compounds. Such compounds require advanced and complex treatment strategies (Liu et al. 2014; Wang et al. 2021; Hayati et al. 2018).

Traditional methods for treating petrochemical wastewater involve adsorption or coagulation coupled with biological processes. However, these methods have limitations associated with process conditions. Hence, there is a growing need for alternative treatment approaches. Advanced oxidation processes (AOPs) emerge as a promising solution in this context. Various physical, chemical, and biological methods can treat petrochemical wastewater (Gopalakrishnan and Bharathiraja 2022). AOPs offer advantages such as the complete mineralization of organic matter, minimal residual material, and compatibility with biological systems (Fernandes et al. 2019, 2020). Among the various methods, the ozone-persulfate process is economically feasible and easy to implement.

AOPs involve chemicals that generate hydroxyl radicals to oxidize organic matter (Honarmandrad et al. 2022). The highly reactive hydroxyl radicals can convert impurities into water, inorganic ions, and carbon dioxide (Glaze et al. 1987) •OH and SO4• are potent oxidizing radicals with redox potentials (E◦) equal to 2.8 V and 2.5–3.1 V, respectively, which can rapidly and non-selectively oxidize and decompose most organic compounds in wastewater (Babuponnusami and Muthukumar 2014; Lee et al. 2020). These two radicals are the primary oxidants responsible for the excellent performance of AOPs compared to conventional treatments (Xiao et al. 2017). When ozone is dissolved in an aqueous persulfate solution, it leads to the generation of a substantial amount of hydroxyl radicals (•OH). The produced •OH activates the persulfate and generates SO4•; the two oxidizing agents act synergistically in the system, improving the treatment efficiency of the system (Amr et al. 2013). The high DOM in wastewater competes with PMS for O3 to produce •OH. Additionally, O3 exhibits excellent de-colorization and decomposition properties for challenging-to-degrade pollutants through both direct oxidation via O3 and indirect oxidation via free radicals (Wang et al. 2022); the O3-PMS process is attractive because of its good stability (Yang et al. 2015).

The application research of O3-PMS coupled catalytic oxidation process in petrochemical wastewater is still blank, and it is mostly used in domestic wastewater and degradation research of new pollutants, as shown in Table 1. This study investigated the efficiency of organic matter removal from petrochemical wastewater by the O3-PMS coupled catalytic oxidation process. The degradation pathway and degradation efficiency of soluble organic matter by advanced oxidation technology were investigated to provide a basis for its further application in practical industrial wastewater treatment. Furthermore, the reactive radicals involved were trapped and identified via quenching experiments to understand the mechanism of radical interactions in the O3-PMS system. Finally, the optimal reaction parameters for the O3-PMS coupled catalytic oxidation were identified for economic evaluation.

Table 1 Comparison of treatment effect of different wastewater by O3-PMS process

Materials and methods

Experimental setup

Triangular wash bottles filled with water samples were placed in a magnetic rotor under the action of the magnetic stirrer as shown in Fig. 1. The water sample to be treated was added to each of the three triangular washing bottles. PMS was added to the samples in wash bottles a and c, following which they were mixed thoroughly. Next, the ozone reactor fed ozone to the two triangular wash bottles b and c. The gaseous ozone is reduced to O2 upon entering the flasks by potassium iodide solution (see equation below).

Fig. 1
figure 1

Experimental schematic diagram showing the experimental setup

$${{\text{O}}}_{3}+2{\text{KI}}+{{\text{H}}}_{2}{\text{O}}={{\text{O}}}_{2}+{{\text{I}}}_{2} +2{\text{KOH}}$$

Source of water samples

The experimental water samples were obtained from the catalyst workshop of Yueyang petrochemical plant in Hunan Province, China. This petrochemical plant primarily produces catalysts used in chemical processing and the production of petrochemicals. Consequently, the plant consumes a lot of water, generating substantial amounts of petrochemical wastewater. Petrochemical wastewater treatment process is shown in Fig. 2.

Fig. 2
figure 2

Petrochemical wastewater treatment process

Some indexes of water quality are shown in Table 2. The initial CODCr (chemical oxygen demand) of the experimental wastewater water samples was 75,000 ± 500 mg/L; the TOC (initial organic carbon) was 30,000 ± 300 mg/L, whereas the total nitrogen content (ammonia nitrogen, nitrite nitrogen) was 300 mg/L or less. The chemical composition was highly complex. Since the chemical components could not be entirely determined, CODCr was analyzed to determine the efficacy of the treatment. When the water samples were brought to the laboratory, the oil and large particles in the water were removed by vacuum filtration The filtered water samples were used for subsequent experiments.

Table 2 Initial water sample index

Test method for removal of soluble organic matter

Petrochemical wastewater (200 mL) at room temperature (20 ~ 25 °C) was taken for soluble organic matter degradation experiments. CODCr was used as the index of soluble organic matter removal rate. The wastewater water samples were filtered and added into a conical flask for ozone treatment in an ozone generator (CF-YG60, Shanmei Shumei, China). A gas flow meter monitored the reactor effluent’s ozone concentration. Catalytic degradation of soluble organic matter was initiated when ozone and PMS were added to the conical flask. A magnetic stirrer mixed the solution at a constant stirring speed (180 r/min). Samples were removed at specified times and set aside for 6 h to maintain stability under ambient conditions. After the samples were dissolved through a dissolution apparatus, a UV spectrophotometer (UV-3600Plus, Shimadzu, Japan) was used to measure its CODCr. The total organic carbon/total nitrogen analyzer (MULTIN/C2100, Jena, Germany) measured the TOC in the water samples. Parallel testing was conducted on multiple samples, and each degradation experiment was repeated three times to ensure reliability, with the average value being calculated.

Method for determination of ozone concentration

The ozone concentration was determined through iodimetry, wherein ozone, exhibiting strong oxidation properties, reacts with an aqueous solution of potassium iodide to produce iodine. Subsequently, the generated iodine is titrated with a standard solution of sodium thiosulfate to sodium iodide, with the endpoint being the complete fading of the solution (Kasprzyk-Hordern et al. 2003). The reaction formula is as follows:

$${{\text{O}}}_{3}+2{\text{KI}}+{{\text{H}}}_{2}{\text{O}}\to {{\text{O}}}_{2}+{{\text{I}}}_{2}\left({\text{coloured}}\right)+2{\text{KOH}}$$
$${{\text{I}}}_{2}+2{{\text{Na}}}_{2}{{\text{S}}}_{2}{{\text{O}}}_{3}\to 2{\text{NaI}}\left({\text{colourless}}\right)+{{\text{Na}}}_{2}{{\text{S}}}_{4}{{\text{O}}}_{6}$$

KI solution (20%, 20 mL) and deionized water (350 mL) were poured into a 500-mL iodine measuring bottle. After stable operation of the ozone generator, the gas flow is controlled at 0.4 L/min, and the gas is passed into a 500-mL iodine bottle containing 20% potassium iodide solution for 5 min. Then, 5-mL (1 + 5) sulfuric acid solution (pH 2) was added, and the bottle was plugged. After thorough mixing, it was left to stand for 5 min away from light. It was then titrated with 0.01 mol/L sodium thiosulfate standard solution until the solution was light yellow. Then, a few drops (about 1 mL) of 1% starch indicator were added and the titration was continued until the blue color just disappeared. The volume of sodium thiosulfate standard solution consumed was recorded. The ozone concentration can be calculated as follows:

$${C}_{{{\text{O}}}_{3}}\left({\text{mg}}/{\text{L}}\right)=\frac{2400\cdot {C}_{{\text{Na}}}\cdot {V}_{{\text{Na}}}}{{V}_{{{\text{O}}}_{3}}}$$

Formula:

CO3:

ozone concentration, mg/L;

VNa:

sodium thiosulfate solution volume used, mL;

CNa:

sodium thiosulfate solution concentration, mol/L;

VO3:

amount of incoming ozone gas, mL.

Methods of analysis of organic substances

The changes in major organic pollutants in water were characterized using a fluorescence spectrophotometer (F-7100, Hitachi, Japan). The changes in total organic carbon (TOC) in water were measured using a total organic carbon/total nitrogen (TOC/TN) analyzer. The non-polar and weakly polar DOM were detected using a 7890-B gas chromatograph 5977 B mass spectrometer (Agilent, Santa Clara, USA) equipped with an HP-5 column (30 m × 250 μm × 0.25 μm, Agilent, Santa Clara, USA). DOM was detected by liquid–liquid extraction (LLE) method using dichloromethane (DCM, HPLC grade) (Ge et al. 2022). The extract was dehydrated by anhydrous sodium sulfate. The temperature of the GC oven was set to 60 °C for 1 min, then increased to 290 °C at a rate of 8 °C/min, and held for 5 min. The temperature was rapidly increased to 320 °C at a rate of 2 °C/min and held for 7 min. The operational parameters of the mass spectrometer aligned with the methodology employed by Ye et al. (2021). Quenching experiments were carried out to confirm the role of free radicals and identify the optimal conditions for the determination of CODcr in the coupled O3-PMS catalytic oxidation system.

Results and discussion

Investigation of the effect of O3-PMS coupled catalytic oxidation on organic matter removal

TOC and CODCr removal effect analysis

The wastewater was oxidized by ozone (ozone concentration was 25 mg/L), persulfate oxidation (persulfate dosage was 0.01 mol/L), and O3-PMS oxidation (ozone concentration was 25 mg/L, and persulfate dosage was 0.01 mol/L), respectively. The plot of CODCr removal rate in wastewater versus time (Fig. 3b) revealed that the O3-PMS had the best removal effect. The TOC removal plot also demonstrated the same result.

Fig. 3
figure 3

Comparison of a TOC and b CODCr removal efficiency by three oxidation methods

From the experimental results, it can be seen that O3-PMS oxidation can attain 60% and 40% removal of TOC and CODCr, respectively, indicating that they have a higher efficiency of wastewater treatment than ozone oxidation and persulfate oxidation methods. This increase in efficiency can be attributed to the synergistic effect of •OH and SO4• in solution.

Comparative analysis of three-dimensional fluorescence

Three-dimensional fluorescence data was collected by fluorescence photometry on the initially connected water samples, water samples oxidized by ozone (ozone concentration was 25 mg/L), water samples oxidized by peroxodisulfate (peroxodisulfate dosage was 0.01 mol/L), and water samples oxidized by O3-PMS (ozone concentration was 25 mg/L; peroxodisulfate dosage was 0.01 mol/L).

Three fluorescent components (C1–C3) were identified from the three-dimensional fluorescence spectra. C1, with Ex (excitation wavelength)/Em (emission wavelength) maxima at 230/330 nm, indicated the presence of aromatic hydrocarbons with bicyclic and tricyclic rings (Maqbool et al. 2020); C2, with Ex/Em maxima at 245/350 nm, corresponded to biodegradable compounds and bio-derivatives with complex structures (i.e., three and four aromatic rings) (Li et al. 2008; Yu et al. 2020; Zito et al. 2020); and C3, with Ex/Em maxima at 210/325 nm, showed two peaks representing phenolic compounds and/or naphthenic acids with one ring (Ge et al.2022; Remolina et al.2022).

The three-dimensional fluorescence diagram reveals that the original water sample (b) has a high C1, C2, and C3 content. The original water sample contains several components, such as aromatic hydrocarbons, biodegradable compounds, cyclic compounds, and other soluble organic compositions. The complex composition of the water renders the treatment difficult. When the water sample undergoes ozone treatment alone, as depicted in Fig. 4b, a significant reduction in impurities, including aromatic hydrocarbons, biodegradable compounds, cyclic compounds, and other soluble organic components, is observed compared to the original water samples. However, despite the evident removal effect with ozone treatment, a small portion of other organic components is generated, possibly resulting from the degradation of large organic molecules into smaller ones under ozone oxidation. Persulfate oxidation occurred when only persulfate was added to the water samples (see Fig. 4c). Compared with the original water samples, part of the soluble organic matter in the water samples was also removed. However, the removal effect was still not obvious as other organic components were also produced. Given that peroxodisulfate oxidation involves large organic molecules, the organic matter is degraded into smaller molecules. When the water samples were treated with ozone and persulfate (Fig. 4d), most of the soluble organic matter in the water samples was removed compared with the original water samples. In comparison to ozone oxidation and peroxodisulfate oxidation, the O3-PMS oxidation system demonstrates more significant removal of soluble organic matter. It generates fewer additional small organic molecules, indicating a synergistic effect between the O3-PMS oxidation system, ozone, and peroxodisulfate. Persulfate exhibits a mutually synergistic effect, consistent with the study of Amr et al. (2013).

Fig. 4
figure 4

Three-dimensional fluorescence comparison of a initial water sample; b ozone oxidation; c persulfate oxidation; d O3-PMS coupled catalytic oxidation experiment

Transition metal ion selection

The organic matter degrading efficiency of the O3-PMS system was further improved by adding transition metal ions. The metal ions catalyzed the system by activating the persulfate.

When the ozone concentration was 25 mg/L and persulfate dosing was 0.01 mol/L, transition metal ion compounds were added. The dosage of transition metal ion compounds (FeSO4, CuSO4, MnSO4, and ZnSO4) was 0.05 mol/L. The metal compounds were added to the coupled system to reduce the cost of the process.

As obvious from the experimental results, the catalytic efficiency of Fe2+ and Cu2+ compounds were the best. In the homogeneous system, the catalytic ability of mixed metal ions was greater than that of a single metal. The best transition metal ion combination for the two-two mixing was determined by the following experiment: the ozone concentration was maintained at 25 mg/L, the persulfate dosage was 0.01 mol/L, and the dosage of multiple transition metals was 0.05 mol/L. Figure 5 b shows the experimental results. Fe2+ and Cu2+ metal ion compounds were selected for the best catalytic effect. Due to the addition of persulfate, the solution is acidic. However, it was not necessary to control the pH as a previous study (De Oliveira et al.2017) pointed out that the metal ion dissolution was higher at lower pH. Additionally, the TOC removal rate showed a positive correlation with the presence of metal ions, indicating a greater transformation from a non-homogeneous to a homogeneous reaction system, thereby enhancing pollutant removal. Moreover, the coupled system outperformed ozone alone, overcoming the limitation of ozone catalytic oxidation’s weak oxidation ability at low pH. Consequently, the impact of pH on the O3-PMS coupled catalytic oxidation system was not investigated.

Fig. 5
figure 5

Role of transition metal ions on the coupled O3-PMS coupled catalytic oxidation system: a effect of single transition metal ion on O3-PMS system; b effect of multiple transition metal ions on O3-PMS system

Study of the O3-PMS coupled catalytic oxidation system

O3-PMS coupled catalytic oxidation of free radicals

O3-PMS coupled catalytic oxidation systems, usually involving ·OH and SO4•, were subjected to free radical quenching experiments to elucidate the role of free radicals. TBA (thiobarbituric acid) is usually used as a ·OH quenching agent only, and EtOH (ethanol) can quench ·OH and SO4• (Kong et al.2019; Yu et al.2019). The addition of TBA to the O3-PMS coupled catalytic oxidation system resulted in a decrease in the degradation efficiency of organic matter. Similarly, the inclusion of EtOH also lowered the degradation efficiency, affirming the significant roles of ·OH and SO4• in the reaction system. The potential effect of superoxide radicals (•O2) must also be considered in the O3-PMS coupled catalytic oxidation system. Experiments with Nitrotetrazolium Blue Chloride NBT showed that there was no change in absorbance at 530 nm, indicating that NBT did not react with superoxide radicals (•O2) during the reaction (Bielski et al.1980; Zheng et al.2022). The results suggest that •O2 radicals may not be present in the O3-PMS coupled catalytic oxidation system. Benzoquinone (BQ) was added as a selective quenching agent for •O2 (Fan et al.2019; Zhang et al.2018; Zheng et al.2022). However, it showed only minimal inhibition of the degradation of soluble organic matter when its concentration was increased to 20 mM. The above findings exclude the effect of •O2 in the coupled O3-PMS catalytic oxidation system.

In the O3-PMS coupled catalytic oxidation system, the •OH and SO4• act synergistically, as seen in Fig. 6. •OH activates PMS, which induces PMS to produce SO4• in solution. Furthermore, when ozone is dissolved in an aqueous PMS solution, more •OH is produced (Eq. 3).

Fig. 6
figure 6

Interaction between •OH and SO4

$$\bullet {\text{OH}}+{{\text{H}}}^{+}+{{\text{e}}}^{-}\to {{\text{H}}}_{2}{\text{O}}$$
(1)
$$\mathrm{SO}_4^-\bullet+\mathrm H^++\mathrm e^-\rightarrow{\mathrm{HSO}}_4^-\bullet$$
(2)
$${{\text{SO}}}_{4}^{-}\bullet +{{\text{OH}}}^{-}\to {{\text{SO}}}_{4}^{2-}+\bullet {\text{OH}}$$
(3)

Investigation of the effect of transition metal ions in O3-PMS coupled catalytic oxidation systems

Removing soluble organic matter by the O3-PMS coupled catalytic oxidation system was not obvious without the addition of any metal ions. However, the addition of four different ions had varying impacts on the removal efficiency of the O3-PMS coupled catalytic oxidation system for soluble organic matter. When the four ions were mixed two at a time, the combination of Fe2+ and Cu2+ exhibited the most effective synergistic effect.

During the metal ion catalysis process, most of HSO5 can react with metal ions to produce a large amount of SO4•:

$$\mathrm M^{\mathrm n+}+{\mathrm{HSO}}_5^-\rightarrow\mathrm M^{\mathrm n+1}+\mathrm{OH}^-+{\mathrm{SO}}_4^-\bullet$$
(4)
$$\mathrm M^{\mathrm n+1}+{\mathrm{HSO}}_5^-\rightarrow\mathrm{Mn}^++{\mathrm{SO}}_5^-+\mathrm{OH}^+$$
(5)

High concentrations of metal ions generate large amounts of oxidants and free radicals in PMS to facilitate the degradation of soluble organic matter. However, the degradation efficiency of soluble organic matter exhibited a gradual increase with higher metal ion concentrations, primarily limited by the concentration of PMS (Zhao et al. 2017).

Study of optimal reaction conditions for O3-PMS coupled catalytic oxidation

Orthogonal experimental design

A certain amount (0.05–0.15 mol/L) of transition metal ion (Fe2+ and Cu2+) mixture was added to the O3-PMS coupled system. Orthogonal experiments were conducted as shown in Table 3, and the data were analyzed for four factors: ozone concentration (5 ~ 25 mg/L), persulfate dosage (0.01 ~ 0.05 mol/L), transition metal ion dosage ratio (0:0, 0:1, 1:0, 2:1, 1:2), and reaction time (0 ~ 2 h), with five levels set (Fig. 7). This orthogonal analysis method was implemented following a previous study (Shang et al.2022). The range analysis of the O3-PMS coupled catalytic oxidation system via orthogonal experiments has been shown in Table 4.

Table 3 Orthogonal experiment on reaction conditions of O3-PMS coupled catalytic oxidation system
Fig. 7
figure 7

Orthogonal experimental effects of the O3-PMS coupled catalytic oxidation system

Table 4 Range analysis table of O3-PMS coupled catalytic oxidation system via orthogonal experiments

Calculation of polar deviation:

$${K}_{i}=\sum_{i=1}^{n}{x}_{i}$$
$${k}_{i}=\frac{{K}_{i}}{n}$$
$$R={K}_{max}-{K}_{min}$$

wherein

Ki:

the sum of the results of the five trials corresponding to the ith level of the factor in the column; i is the number of levels under each factor.

ki:

mean value of Ki;

n:

number of levels under each factor;

Kmax:

maximum value of the column ki;

Kmin:

The minimum value of the column ki.

The polar analysis results show that the order of factors is as follows: reaction time > peroxysulfate dosage > ozone concentration > transition metal ion dosage ratio.

Based on the extreme difference analysis, the effect curve is depicted in Fig. 8. The orthogonal experimental effect plot indicates that the oxidation efficiency was poorest at an ozone concentration of 15 mg/L, resulting in the lowest average CODCr removal efficiency. The best reaction was achieved when the ozone concentration was 10 mg/L. Normally, the degradation rate of target pollutants by ozone in wastewater is influenced by the mass transfer of ozone. This, in turn, is connected to the decomposition kinetics of ozone in water, as well as the quantity and size of ozone bubbles generated (Chu et al.2007; Mitani et al.2005). At an ozone concentration of 10 to 15 mg/L, the CODCr removal efficiency decreased because as the ozone concentration increased, the volume of bubbles in the reactor increased, affecting the mass transfer efficiency of ozone. On the contrary, at lower concentrations, the rapid generation of small bubbles during rupture expedited the indirect oxidation process of ozone, leading to the production of numerous hydroxyl radicals. This acceleration contributed to the degradation of organic pollutants and resulted in the degradation of organic pollutants from large molecular pollutants to small molecular pollutants or even complete degradation to CO2 and H2O (Chu et al.2007; Hernández et al. 2022; Alimoradi and Stohr 2020). When the ozone concentration was 15 to 25 mg/L, the CODCr removal rate continued to increase with the ozone concentration due to the synergistic effect of ozone and persulfate in this coupled system.

Fig. 8
figure 8

Reaction kinetics analysis: a CODCr removal; b TOC removal; c CODCr/TOC removal rate; d zero-order reaction kinetics; e first-order reaction kinetics; f second-order reaction kinetics

The least effective CODCr removal was observed at a persulfate dosage of 0.04 mol/L, while the most efficient CODCr removal occurred at a persulfate dosage of 0.02 mol/L. This disparity in removal efficiency can be mainly attributed to the constraint resulting from persulfate concentration. The highest and lowest average CODCr removal efficiencies were attained at transition metal ion dosing ratios of 1:2 and 0:1, respectively. The oxidation efficiency was optimum when the reaction time was 2.0 h (Table 5). Thus, the CODCr removal efficiency positively correlated with the reaction time. These orthogonal experimental results showed that the optimal removal conditions of CODcr were as follows: ozone concentration of 10 mg/L, persulfate dosage of 0.02 mol/L, Fe2+: Cu2+ ion dosage ratio of 1:2, and a reaction time of 2 h.

Table 5 Correlation analysis of fitted curves for O3-PMS coupled catalytic oxidation process

The water quality indices of the O3-PMS coupled catalytic oxidation system treated under optimal removal conditions of CODCr are shown in Table 6. Post O3-PMS treatment under the optimal reaction conditions, the CODCr and TOC removal rates reached 70% and 79.3%, respectively. Furthermore, the TN and NH3-N levels could be reduced to less than 30 mg/L. These rates were achieved under the optimal reaction conditions of O3-PMS, resulting in a TOC removal rate of 79.3%.

Table 6 Water quality indices of O3-PMS coupled catalytic oxidation system treated under optimal reaction conditions

Kinetic analysis of O3-PMS coupled catalytic oxidation reaction

The experimental results are modeled using the COD removal rate as the index and fit into kinetic equations (Ahmadi et al.2016). Typically, the simulated degradation process is described by zero-order, first-order, and second-order kinetic equations. In the process of O3-PMS coupled catalytic oxidation treatment of petrochemical wastewater, samples were taken at 0, 15, 30, 45, 60, 75, 90, 105, and 120 min. Zero-order, first-order, and second-order reaction kinetics equations were adopted, with C0-Ct, ln (C0/Ct), 1/Ct-1/C0 as the ordinate and time t as the abscissa, respectively. Reaction kinetics fitting was performed. The linear expression equations are as follows:

$${C}_{0}-{C}_{t}={k}_{0}t$$
$${\text{ln}}\left(\frac{{C}_{0}}{{C}_{t}}\right)={k}_{1}t$$
$$\frac{1}{{C}_{t}}={k}_{2}t+\frac{1}{{C}_{0}}$$

wherein

C0:

CODCr concentration at the initiation of ozone-persulfate coupled catalytic oxidation reaction, mg/L.

Ct:

COD concentration at time t in ozone-persulfate coupling catalytic oxidation reaction, mg/L.

K0:

zero-order rate constant of O3-PMS coupled catalytic oxidation reaction.

K1:

first-order kinetic rate constant of O3-PMS coupled catalytic oxidation reaction;

K2:

second-order rate constant O3-PMS coupled catalytic oxidation reaction;

According to the fitting results (Fig. 8; Table 5), the linear correlation coefficients (R2) obtained by linear fitting of zero-order, first-order, and second-order kinetics are 0.97434, 0.93783, and 0.93108, respectively. It can be seen that the CODCr removal efficiency of O3-PMS coupled catalytic oxidation process basically conforms to the zero-order kinetic law.

Gas chromatography-mass spectrometry (GC–MS) analysis

The petroleum hydrocarbons in wastewater were analyzed by gas chromatography-mass spectrometry (GC–MS). The GC–MS analysis indicated the presence of hydrocarbon and aromatic compounds in the water, as detailed in Tables 7 and 8. The application of the O3-PMS coupled catalytic oxidation method led to the removal or degradation of these identified compounds, providing additional confirmation of the effectiveness of the O3-PMS coupled catalytic oxidation process.

Table 7 Organic content in before processing wastewater water samples
Table 8 Organic content in after processing wastewater water samples

The GC–MS analysis of organic matter in water samples before and after the reaction, combined with three-dimensional fluorescence data (Fig. 4) was used to investigate the degradation mechanism of organic matter. The study inferred potential intermediate products and analyzed types of organic matter resistant to the O3-PMS coupled catalytic oxidation process. This analysis serves as a foundational step for further research. As shown in Figs. 9 and 10, the O3-PMS coupled catalytic oxidation can effectively degrade organic compounds such as tryptophan (C12H15N2O2) and tyrosine (C9H11NO3), as well as some aromatic compounds and hydrocarbons. It is however not successful in degrading organic compounds such as C8H16O2, C7H12O2, and C8H16O2, necessitating further treatment.

Fig. 9
figure 9

Initial water sample GC–MS processing diagram: a initial water sample GC–MS mass spectrometry; b GC–MS mass spectrum of water treated by O3-PMS coupled oxidation catalysis

Fig. 10
figure 10

Degradation pathway of soluble organic matter

Cost evaluation of wastewater treatment

The CODCr removal efficiency was used to calculate the cost of wastewater treatment which was compared with those reported in previous studies (Wang et al. 2020; Cako et al. 2020). The O3-PMS coupled catalytic oxidation system required specific energy inputs, including an ozone reactor, and persulfate and transition metal ions. The ozone reactors consumed 6 kW of electricity per hour, the PMS was priced at $0.036 per gram, and the added metal cost was $0.010 per gram. The wastewater treatment cost details are presented in Table 9.

Table 9 Cost assessment

The findings from this study suggest that O3-PMS coupled catalytic oxidation is a cost-effective technology for the treatment of petrochemical wastewater. Typically, it is applied upstream of the bioreactor to facilitate the breakdown of macromolecules into smaller ones, promoting absorption by microorganisms.

Conclusions

In this study, O3-PMS exhibited significant advantages in the deep treatment of petrochemical wastewater. The optimal parameters, degradation mechanism, and economic evaluation of the catalytic process were investigated in this study. The best CODCr removal was achieved at an ozone concentration of 20 mg/L, a persulfate dosage of 0.02 mol/L, a Fe2+: Cu2+ dosage ratio of 1:2, and a reaction time of 2 h. The results of quenching experiments demonstrated that hydroxyl radicals and persulfate radicals had a critical role in the mixed system. In the presence of reactive species, complex molecules in challenging-to-degrade pollutants underwent fragmentation into smaller molecules, leading to their removal. O3-PMS coupled catalytic oxidation can effectively degrade aromatic and hydrocarbon compounds. Using the coupled O3-PMS catalytic oxidation system, the total cost of treating 1 m3 of wastewater to achieve CODCr ≤ 20,000 mg/L (CODCr treatment rate of 70%) was calculated to be US$0.322.

Overall, the O3-PMS coupled catalytic oxidation process is a cost-effective technology for advanced industrial wastewater treatment. In future research, the connection of multiple O3-PMS coupled catalytic oxidation reaction systems in series or parallel configurations could enhance treatment capacity and efficiency. Integrating additional O3-PMS coupled catalytic oxidation systems is anticipated to further enhance the CODCr removal rate, ultimately meeting recommended wastewater discharge standards.