Introduction

Formation of metal-vapor plasmas in a pulsed capillary discharge generates high-density electrothermal plasma from the ablation of the metallic liner material with typical number densities in the range of 1026–1027 m−3, and temperatures in the range 1–5 eV [1]. The saturated vapor pressure and the dynamic temperature of molten metal largely affect the formation of the metal vapor plasma and its distribution. Purity and bulk density of the plasma is dependent on the liner material and device dimensions. Inappropriate arc conditions, lack of arc control, contamination on the electrode surfaces or electrode sever erosion may lead to metal vapor contamination [26]. Even the clusters coming out of the ablated metal surface may lead to formation of dusty plasma as it is quite commonly found in plasmas with an electron temperature below 10 eV. In such a case the plasma is not fully ionized, and thus the ions tend to collide with neutral atoms as well as the clusters. In the experiments under consideration, where the screening length is typically less than a millimeter, and the plasma pressure is in hundreds of MPa, collisionality could be quite significant and hence the cluster formation is becoming eminent.

Unlike the case of insulating materials like Lexan or other non-conductive polycarbonate resins, a capillary discharge system with ablative metallic sleeve will have to be equipped with insulating ends to prevent short circuiting. A 1.0 cm long insulating guard in tubular shape is kept at each side of the metallic sleeve, which keeps the metallic sleeve floating and prevents short-circuiting the discharge current. The capillary in this configuration, as illustrated in Fig. 1, is connected to an expansion volume to simulate the flow into a fusion reactor vacuum vessel following a disruption event. The capillary source and the expansion chamber simulate the divertor and the vacuum vessel, respectively.

Fig. 1
figure 1

Schematic diagram of a capillary discharge with ablative metallic sleeve connected to an expansion chamber simulating the fusion vacuum vessel

To investigate the compressibility index in metal vapor plasma, in the simulation of fusion disruption, six metals were chosen as sleeve materials for their possible application in various plasma facing components; namely tungsten (W), molybdenum (Mo), iron (Fe), Chromium (Cr), Titanium (Ti) and aluminium (Al). The ETFLOW solver [7] has been run for multiple values of peak discharge current covering a range of 40–100 kA, for all selected metal liners. The ETFLOW calculates the temperature T (eV), pressure P (MPa), number density Np (particles/m3), bulk density ρ (kg/m3), plasma bulk velocity Vbulk (m/s) and the total ablated metal mass Mabl (mg) at each axial node. The peak values at the last node, the capillary exit, are taken as the values of interest in simulating the plasma flow and expansion into the vacuum vessel. Ionization of individual atoms, as well as the cluster formation and subsequent ionization in the ablated metal-vapor plasma bulk, have been taken into account. In the present case, the first and the second ionization have been considered for isolated atoms, as well as the smallest atomic cluster (as a dimer having a single positive charge). The effect of plasma bulk temperature and the effective atomic numbers on the metal-vapor plasma bulk flow parameters have been investigated. As well known in the compressible flow regime, the adiabatic compressibility index (γp) is an important aspect that significantly affects the supersonic flow patterns. In this work mathematical models for the adiabatic compressibility index of partially ionized metal vapor have been proposed, that include plasma bulk temperature, atomic ionization energies and corresponding effective atomic numbers, dimer ionization energy and some predictive parameters that account for associated non-linearity as well as non-ideality.

Temperature-Dependent Compressibility Index Models

The isolated atoms or the monomers and the dimers being considered as the main constituents of the partially ionized high density metal vapor bulk; assuming the non-interacting, ideal gas behaviour of the constituents in a mixture of monoatomic and diatomic gases, one would prefer a linear approximation approach in finding the adiabatic compressibility index of the system resulting in an approximate value of \(\gamma_{p} \approx \left( {\gamma_{Mono} + \gamma_{dia} } \right) / 2 \approx 1.53\). But partially ionized, very high density, high temperature, high pressure electrothermal plasmas exhibit highly non-linear behavior and the modeling of adiabatic compressibility index as a function of plasma bulk temperature becomes much more complicated. Two similar, yet different models for the adiabatic compressibility index (γp) have been proposed in this work. For each model four cases have been presented, which essentially make the formulae quite versatile and capable of explaining any irregular changes that might occur in the parameter profiles under different experimental conditions. The first model for γp is given below in Eq. (1).

$$\left. {\begin{array}{*{20}l} {\frac{{\gamma_{p} }}{{\gamma_{p} - 1.53}}\, = \,1.1 + 0.25*\frac{{\left\{ {a_{1} \left( {\frac{{E_{I1} }}{{T_{p} }}} \right)^{{a_{2} }} + b_{1} \left( {\frac{{E_{I2} }}{{T_{p} }}} \right)^{{b_{2} }} + c_{1} \left( {\frac{{E_{Dim} }}{{T_{p} }}} \right)^{{c_{2} }} } \right\}}}{{\left( {1 + Z_{comb}^{*} } \right)^{d} }},} \hfill \\ {\left( {0.25 \le T_{p} (eV)\, \le\, 10} \right)} \hfill \\ {{\text{where}}, Z_{comb}^{*} = \left( {Z_{1}^{{k_{1} }} + Z_{2}^{{k_{2} }} } \right)^{{\frac{1}{{k_{1} + k_{2} }}}} } \hfill \\ {\gamma_{p} \left( {T_{p} < 0.25\, eV, Z_{comb}^{*} } \right) = \gamma_{p} \left( {T_{p} = 0.25\, eV, Z_{comb}^{*} } \right)} \hfill \\ {\gamma_{p} \left( {T_{p} > 10\, eV, Z_{comb}^{*} } \right) = \gamma_{p} \left( {T_{p} = 10\, eV, Z_{comb}^{*} } \right)} \hfill \\ \end{array} } \right\}$$
(1)

Here E I1 and E I2 are the ionization energies corresponding to the first and second ionizations respectively, for an isolated atom in the gaseous phase. E Dim is dimer ionization energy, T p is the plasma bulk temperature in eV, Z 1 and Z 2 are the effective atomic numbers in the first and second ionization of isolated atom, respectively. The parameters a 1, a 2, b 1, b 2, c 1, c 2, k 1, k 2 and d are chosen intuitively and they take into account non-ideal as well as non-linear effects associated with the system. Four specific cases defined by four sets of values of the above mentioned parameters were investigated. These cases will enable an insight into the effect of dynamically changing γp on the metal vapor plasma flow characteristics. Table 1 lists the selected values of the parameters for each case.

Table 1 Non-linearity parameters for Model 1

For all selected metals, the plots for γ(Tp) will follow a similar profile. The departure from one case to another will also be very similar, as a generic mathematical model has been used. The values of γ(Tp) as a function of Tp for tungsten using Model 1 are illustrated in Fig. 2. The adiabatic compressibility index increases with the increase in the plasma temperature for all cases with less increase for case 1, which appears to be more flat. Strong increase is obvious for cases 3 and 4, almost a factor of 2 higher at the highest temperature (10 eV) as compared to the lowest temperature of 0.25 eV.

Fig. 2
figure 2

γ(Tp) as a function of plasma temperature Tp for tungsten using Model 1

Model 2 is somewhat similar to Model 1, with a major difference in writing the parameter d as the exponent to a mathematical expression that contains the combined optimized orbital exponent \(Z_{comb}^{*}\) (as defined in Eq. 1), which includes the individual optimized orbital exponents Z 1 and Z 2, respectively. Essentially this means for higher values of d, the value of γ p will depend on a polynomial of \(Z_{comb}^{*}\) manifesting a higher extent of non-linearity. The effective nuclear charge increases with the increase in the cluster size [8]. Thus, by tuning the non-linearity parameters in the expression of adiabatic compressibility index to suitable values, such that \(Z_{comb}^{*}\) covers an adequately varied range of numerical values; the effect of the cluster formation and subsequent ionization on the bulk plasma flow characteristics can be computed. In case of Model 2, single power on each of the individual optimized orbital exponents has been used. Model 2 is given mathematically in Eq. (2):

$$\left. {\begin{array}{*{20}l} {\frac{{\gamma_{p} }}{{\gamma_{p} - 1.53}} = 1.2 + 0.15* \frac{{\left\{ {a_{1}^{\prime } \left( {\frac{{E_{I1} }}{{T_{p} }}} \right)^{{a_{2}^{\prime } }} \,+\, b_{1}^{'} \left( {\frac{{E_{I2} }}{{T_{p} }}} \right)^{{b_{2}^{\prime } }} \,+\, c_{1}^{'} \left( {\frac{{E_{Dim} }}{{T_{p} }}} \right)^{{c_{2}^{\prime } }} } \right\}}}{{\left( {r_{1}^{\prime } Z_{1}^{{s_{1}^{\prime } }} + r_{2}^{\prime } Z_{2}^{{s_{2}^{\prime } }} } \right)}};} \hfill \\ {\left( {0.25\, \le \,T_{p} \left( {eV} \right) \,\le\, 10} \right)} \hfill \\ {\gamma_{p} \left( {T_{p} < 0.25\, eV, Z_{1} ,Z_{2} } \right) = \gamma_{p} \left( {T_{p} = 0.25\, eV, Z_{1} ,Z_{2} } \right)} \hfill \\ {\gamma_{p} \left( {T_{p} > 10\, eV, Z_{1} ,Z_{2} } \right) = \gamma_{p} \left( {T_{p} = 10\, eV, Z_{1} ,Z_{2} } \right)} \hfill \\ \end{array} } \right\}$$
(2)

where, E I1, E I2, E Dim , T p , Z 1 and Z 2 bear the same meaning as in Model 1. \(a_{1}^{'}\), \(a_{2}^{\prime }\), \(b_{1}^{\prime } ,\;b_{2}^{\prime } ,\;c_{1}^{\prime } ,\;c_{2}^{\prime } ,\;r_{1}^{\prime } ,\;r_{2}^{\prime } ,\;s_{1}^{\prime } \;{\text{and }}s_{2}^{\prime }\) are the parameters that incorporates non-linearity and non-ideal effects. By using these models for γ p, unexpected bulk irregularities and sudden variation in bulk flow characteristics can be explained, which may arise in various experimental scenarios. Table 2 lists the selected values of the parameters for each case.

Table 2 Non-linearity parameters for Model 2

The values of γ(Tp) as a function of Tp for tungsten using Model 2 are illustrated in Fig. 3. Again, the adiabatic compressibility index increases with the increase in the plasma temperature for all cases as was previously shown when using Model 1. However, the rate of increase is not as high as that of Model 1.

Fig. 3
figure 3

γ(Tp) as a function of plasma temperature Tp for tungsten using Model 2

The ionization energies for the single isolated metal atoms as well as the dimers have been taken from available well-known literature [912]. Some of the thermodynamic properties for specific metals were obtained from the published work of Desai [13]. The effective atomic numbers or the optimized orbital exponents were obtained using information available in published literature [14, 15]. Table 3 lists the ionization energies and the optimized orbital exponents of the selected metals. By incorporating these models for γ into the temperature sensitive supersonic flow equations as well as the shock models, as described in one of our previous work [18], it was shown that variation in bulk flow parameters of the metal vapor plasma is caused by non-linear changes in adiabatic compressibility index under isentropic conditions of the expanding plasma bulk.

Table 3 Ionization energies and optimized orbital exponents

Result and Discussion

Capillary exit parameters of interest have been tabulated in Tables 4, 5, 6 and 7 for four different peak discharge current values of 40, 50, 60 and 80 kA, respectively, which covers a reasonably wide range. The exit parameters were calculated using the 1-D ETFLOW code [7]. The exit parameters in Tables 4, 5, 6 and 7 are the plasma temperature T (eV), pressure P (MPa), number density Np (#/m3), density ρ (kg/m3), plasma exit velocity Vbulk (m/s) and total ablated mass Mabl (mg). Tables 4, 5, 6 and 7 clearly show that the peak magnitude of all plasma exit parameters increases with the increase of the peak discharge current. However this increment in flow parameter is not linear with the increment in the peak discharge current. The capillary exit data obtained here are the bulk parameter values with which the metal vapor from ablation leaves the micro-nozzle and enters the converging section of the transition region [ 1618 ].

Table 4 Capillary exit parameters for peak discharge current I = 40 kA
Table 5 Capillary exit parameters for peak discharge current I = 50 kA
Table 6 Capillary exit parameters for peak discharge current I = 60 kA
Table 7 Capillary exit parameters for peak discharge current I = 80 kA

Figures 4 and 5 display the Mach number profile along the axial direction into the transition region (Fig. 4) and the expansion chamber (Fig. 5) showing that the Mach number is almost the same for all metals, which was previously discussed in our work on flow patterns and scaling of the flow bulk parameters [16, 17]. However, the minor deviations that arise are solely due to the changes in the adiabatic compressibility index, which has been modeled as a function of plasma bulk temperature as well as metal properties.

Fig. 4
figure 4

Mach number along the axial length in the transition region for I = 40 kA peak current for Case 1 (Model 1)

Fig. 5
figure 5

Mach number along the axial length in the expansion chamber for Case 1 (Model 1)

Figures 6, 7, 8, 9, 10, 11, 12 and 13 show the flow bulk parameters along the axial direction for Ipeak = 40 kA for Case 1 (Model 1). Figure 6 shows the plasma temperature along the axial length in the transition region immediately after the ET source exit (0–0.007 m) for I = 40 kA, Case 1 (Model 1). The temperature drops quickly inside this region for all tested metals. The temperature into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber is shown in Fig. 7, where the temperature rises and stays almost constant through the length of the chamber.

Fig. 6
figure 6

Plasma temperature along the axial length in the transition region immediately after the ET source exit

Fig. 7
figure 7

Plasma temperature into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber

Fig. 8
figure 8

Plasma pressure along the axial length in the transition region immediately after the ET source exit

Fig. 9
figure 9

Plasma pressure into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber

Fig. 10
figure 10

Plasma bulk velocity along the axial length in the transition region immediately after the ET source exit

Fig. 11
figure 11

Plasma bulk velocity into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber

Fig. 12
figure 12

Plasma bulk density along the axial length in the transition region immediately after the ET source exit

Fig. 13
figure 13

Plasma bulk density into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber

Figure 8 shows the plasma pressure along the axial length in the transition region immediately after the ET source exit (0–0.007 m) for I = 40 kA, Case 1 (Model 1). The pressure drops quickly inside this region for all tested metals, and has a similar profile of that of the temperature. The pressure into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber is shown in Fig. 9, where the pressure rises and stays almost constant through the length of the chamber; a pattern similar to that of the temperature.

Figure 10 shows the plasma bulk velocity along the axial length in the transition region immediately after the ET source exit. The bulk velocity increases inside this region for all tested metals and remains at a constant value after 0.007 m into the transition. The velocity into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber is shown in Fig. 11, where the velocity slightly drops and stays almost constant through the length of the chamber.

Figure 12 shows the plasma bulk density along the axial length in the transition region immediately after the ET source exit. The bulk density decreases inside this region for all tested metals and remains at a constant value after 0.007 m into the transition. Of interest is the higher drop rate in the density of tungsten as compared to all other tested metals. The density into the expansion chamber immediately after exiting the transition region and through the axial direction of the chamber is shown in Fig. 13, where the density increases and stays almost constant through the length of the chamber, with tungsten density rises higher than all other metals.

Table 8 shows that as the bulk plasma flow becomes sub-sonic inside the expansion chamber of uniform area cross-section, some of the steady-state flow parameters for the metal vapor plasmas differ in magnitude by quite a significant amount, whereas the other parameters do not vary that much. For example the steady state plasma bulk temperature for tungsten has been found to be 2.005 eV, which is the maximum value; whereas the lowest bulk temperature was found to be 1.505 eV in case of chromium vapor plasma. The steady-state plasma pressure is the maximum in case of iron ablated plasma and was found to be 137.67 MPa, while the minimum pressure has been estimated to be 124.05 MPa in the case where titanium sleeve was used. Looking at the above two flow parameters one does not see much difference between the maximum and the minimum steady-state values. But there is a significant change in case of the plasma bulk density. The maximum bulk density in the steady-state subsonic conditions has been estimated to be 149.64 kg/m3, for the tungsten vapor plasma, which is about 7 times larger than that found as the minimum of all others, a considerably low 20.07 kg/m3 for aluminium vapor plasma. For the plasma bulk velocity the trend is opposite. The maximum steady-state bulk speed of 4704.17 m/s occurs in case of aluminium vapor plasma and it is almost a factor of 3 higher than that of the minimum bulk velocity 1678.86 m/s in the case of tungsten.

Table 8 Bulk flow parameter values at steady-state subsonic Condition inside the chamber

In order to calculate the erosion thickness \(\left( {\Delta x} \right)\) of the metallic sleeves used in the simulation experiment to predict the extent of damage on the plasma facing surfaces prior to the supersonic expansion of the arc-ablated partially ionized aerosol mass, a new mathematical formula based on simple mass balance has been introduced:

$$M_{abl} = 2\pi \left( {r_{c} + \frac{{\Delta x}}{2}} \right) \Delta x L \rho_{Metal}$$
(3)

where, r c is the inner radius of the capillary sleeve; \(\Delta x\) is the erosion thickness, L is the effective length of the capillary that is exposed to the radiant heat flux, ρ Metal is the density of the metal used in the ablative sleeve and M abl is the ablated mass as predicted by the ETFLOW plasma code [7]. Equation 3 leads to the following quadratic equation, which gives the erosion thickness for a particular metal exposed to radiant heat flux at a certain peak discharge current:

$$\frac{{\left( {\Delta x} \right)^{2} }}{2} + r_{c} \Delta x - \frac{{M_{abl} }}{{\left( {2\pi L \rho_{Metal} } \right)}} = 0$$
(4)

All the lengths are in meter, density is in kgm−3, ablated mass is in kg. The data presented in Tables 4, 5, 6 and 7 have been used in tandem with Eq. 4 to calculate the erosion thickness of the metals of interest for the listed peak current values and are tabulated in Table 9 and plotted in Fig. 14.

Table 9 Erosion thicknesses of tested metals as a function of discharge current
Fig. 14
figure 14

Erosion thickness (µm) versus peak discharge current (kA)

As seen from Table 9, and Fig. 14, the ablated mass increases with the increase in the peak discharge current. The removal thickness is the largest in case of aluminium followed by titanium, chromium, iron, molybdenum and tungsten, respectively. Lesser removal thickness of a metal indicates a lesser extent of surface damage, which intuitively makes it a suitable candidate for being used as a plasma facing component under such high heat-flux conditions. The computational results obtained in this current work are in agreement with recent published experimental and computational research work on erosion of plasma-facing components that suggests tungsten and molybdenum to be good materials among the potentially durable metals which can be used in practical fusion reactors [1922]. These results demonstrate the extent of disruption for each of the selected metals, which enables selection of the right metal for a particular plasma-facing component in future fusion reactors, as well as other applications in which metallic components are exposed to high heat flux deposition. As shown in Fig. 14, it appears that the erosion is close to linear increase with the increase in the magnitude of the peak discharge current.

Effect of Non-linearity on Tungsten Vapor Plasma: A Specific Case

The choice of a capillary running a peak discharge current of 60 kA is an attempt to run at higher current in order to look into non-ideal and non-linear behavior in the flow parameters associated with the adiabatic compressibility index. Tungsten is selected as a case study due to its importance as a potential plasma facing material in the divertor of fusion reactors. It is a material selected in recent research as the armor for the divertor upper vertical target, dome and cassette liner, as well as for lower baffle because of its unique resistance to ion and charge-exchange particle erosion in comparison with other materials [21]. Tungsten coated surfaces now represent a fraction of 65 % of all plasma facing components (~25 m2). The only two other major components that are not yet coated are the strike-point region of the lower divertor as well as the limiters at the low field side [21, 22].

Nonlinearity parameters from Tables 1 and 2, representing Models 1 and 2, respectively, are considered for this specific case of tungsten. Figure 15 shows the Mach number along the axial length for the peak current of 60 kA for Model 1, where it is obvious that the Mach number, being a very strong function of the cross-sectional area, hardly depends on the non-linearities associated with the adiabatic compressibility index and remains almost the same for all the cases, irrespective of the used γ model, typical to the behavior previously reported in Ref. [1618].

Fig. 15
figure 15

Mach number along the axial length for a peak discharge current of 60 kA (Model 1)

The results of the tungsten case study will be illustrated for the axial length up to 0.3 meters. Figure 16 shows the plasma bulk density along the axial length for I = 60 kA using Model 1, where it is obvious that non-linearity and non-ideal effects can considerably affect the supersonic flow of the metal vapor bulk plasma. The plasma bulk density drops fast in the converging nozzle then rises in the conversing section and reaches steady state in the expansion chamber. The same behavior is also typical when using Model 2 as illustrated in Fig. 17.

Fig. 16
figure 16

Plasma bulk density along the axial length for I = 60 kA (Model 1)

Fig. 17
figure 17

Plasma bulk density along the axial length for I = 60 kA (Model 2)

Similar behavior is also seen in the pressure profiles along the axial direction when using Model 1 (Fig. 18) and Model 2 (Fig. 19). The pressure drops fast in the transition section, rises at entry to the chamber and remains at a steady state through the expansion volume. However, this is not the case for the plasma bulk velocity as it increases in the transition section then drops to a steady state value into the expansion volume, as seen in Fig. 20 (Model 1) and Fig. 21 (Model 2).

Fig. 18
figure 18

Plasma pressure along the axial length for I = 60 kA (Model 1)

Fig. 19
figure 19

Plasma pressure along the axial length for I = 60 kA (Model 2)

Fig. 20
figure 20

Plasma bulk velocity along the axial length for I = 60 kA (Model 1)

Fig. 21
figure 21

Plasma pressure along the axial length for I = 60 kA (Model 2)

Plasma temperature, as seen in Fig. 22 (Model 1) and Fig. 23 (Model 2), follows the same behavior of density and pressure, it drops fast in the transition section, rises at entry to the chamber and remains at a steady state through the expansion volume. This behavior is expected due to the fact that the plasma kinetic pressure is dependent on both density and temperature. Tables 10 and 11 summarize the results of the parameters for each of the four cases when using Model 1 (Table 10) and Model 2 (Table 11).

Fig. 22
figure 22

Plasma temperature along the axial length for I = 60 kA (Model 1)

Fig. 23
figure 23

Plasma temperature along the axial length for I = 60 kA (Model 2)

Table 10 Bulk flow parameter at steady-state subsonic condition inside the chamber for γ Model 1 using capillary exit data corresponding to Ipeak = 60 kA
Table 11 Bulk flow parameter at steady-state subsonic condition inside the chamber for γ Model 2 using capillary exit data corresponding to Ipeak = 60 kA

As has been seen in Figs. 16, 17, 18, 19, 20, 21, 22 and 23 it is obvious that non-linearity and non-ideal effects can affect the supersonic flow. All the bulk flow parameters exhibit significant changes, however plasma bulk temperature has been found to be least affected by the non-linear changes in the adiabatic compressibility index (γ) of the bulk plasma. In case of Model 1, extreme cases may see a swing in steady-state plasma bulk temperature by as much as 7.36 %, whereas in case of Model 2 this swing has been observed to increase up to 28.982 % with respect to the lower end value, the actual differences being not too large. Plasma bulk density and plasma pressure have been observed to get affected by a large amount due to the non-linear effects. Steady-state plasma bulk density has been observed to differ by a significant amount; about a factor of 4.27 in case of Model 1, and by a factor of 4.10 in case of Model 2, the lowest bound being the reference point of the respective computational instances. Plasma pressure in the expansion chamber has been observed to differ by a factor of 2.38 in case of Model 1, and by a factor of 2.54 in case of Model 2, in each of the instances the lowest pressure being the reference point. Plasma bulk velocity, however exhibits a much lower sensitivity towards these non-ideal and non-linear effects. In case of Model 1, extreme case values differ by 9.92 % and the difference goes up to 20.62 % in case of Model 2. As the bulk velocity (V) is dictated by the sonic speed (a) at a certain temperature (T), pressure (P), and density (ρ); thus it depends also on the value of γ. The Mach number is = V/a, where a = (γP/ρ)1/2.

In the present set-up, the steady-state subsonic flow inside the expansion chamber is characterized by a constant Mach number (Ma ≈ 0.6–0.7). irrespective of the various cases demonstrated in this work. Thus clearly it can be seen that for our purpose—\(V \propto \left( {\gamma P/\rho } \right)^{1/2 }\). From the models of adiabatic compressibility index, it can be seen that \(\left( \gamma \right)^{1/2 }\) does not differ much in the various cases of interest, even if the extreme limits are considered. Thus steady–state plasma velocity is dictated by the ratio of the plasma bulk pressure to the plasma bulk density. The higher the value \(\left( {P/\rho } \right)\). ratio the greater is the steady-state bulk velocity. Lower values of ρ in some cases indicate that there may be higher rate of recombination, cluster formation, or agglomeration in occasional instances resulting in an unexpected drop in the plasma bulk density, which results in a proportional decrease in the plasma pressure. These are the form of in-system physical hindrances which essentially slows down the steady state plasma flow. The minor changes in plasma bulk temperature indicate that the processes are energetically sble and consistent. Nevertheless, the non-linear effects help in determining the safety factor in designing the active volume as it should be able to hold the plasma with a sufficiently high bulk pressure.

Conclusion

In this work the effect of temperature-dependent adiabatic compressibility index on the supersonic plasma jet generated from arc-ablated metal sleeves has been investigated. Looking at the disruptive nature, one can decide upon proper metals for the plasma-facing components. Additionally added safety can also be ensured as nonlinearities have been taken into account to some extent. The observed deviation is attributed to the added parameters but helped to have an insight towards 1-D expansion behavior of moderate-temperate metal vapor plasmas.