1 Intoduction

Environmental protection has become a concern around the world in recent years. The hazardous toxic environmental pollutants arising from industrial wastes and man-made activities threaten the lives of all living things [1]. One of such toxic pollutants is aromatic 2-amino phenols containing hydroxyl and amino groups on benzene ring, which have own benefits (such as amphoteric nature, good reducing agents, chemically reactive) and harms (such as easy dermal and cell membrane penetration leading to genotoxicity, mutagenicity and hepatotoxicity as well as deoxyribonucleic acid (DNA) damage induced by present metal ions) [2]. Harmful impacts are the results of extensive application of these compounds as raw materials in various industries, petroleum additives, chemical inhibitors and synthetic intermediates [3]. Accordingly, it is essential to determine the concentration of 2-aminophenol in various media using an effective analytical technique. Bisphenol A is a raw material extensively applied for the construction of epoxy resins and polycarbonate plastics, as well as thermal receipts, medical equipment, nursing bottles, canned beverage containers and pediatric toys. Limited amounts of bisphenol A can enter the human body by penetrating the packaging of food and beverage products [4,5,6,7]. This compound can disrupt the endocrine glands, thereby influencing the reproduction of aquatics and inducing various human health problems [8]. Accordingly, it is vital to develop an effective method to rapidly and sensitively determine the concentration of bisphenol A in various media. In this regard, there have been various analytical techniques to detect the presence of highly toxic and low degradable bisphenol A and 2-aminophenol, including spectrophotometry [9], chromatography [10], and also electrochemical approaches [11, 12].

It should be mentioned that the electrochemical methods have been special in this context owing to merits like inexpensiveness, rapid response, facile facilities and easy to use [13,14,15,16,17,18,19,20,21,22]. Electrochemical sensing is continuously growing area in the electrochemical fields. When comparing with conventional electrodes, chemically modified electrodes (CMEs) have impressive reduction/oxidation potential, rapid kinetics of electron transfer, admirable electro-optical properties and stable electrode surfaces in electro analysis [23,24,25,26,27,28,29,30,31,32]. Nanotechnology has led to great advances in various fields [33,34,35]. Nanomaterials provided promising ground for the development of various potent analytical approaches like electrochemical sensors for sensitively and selectivity monitoring [36,37,38,39,40,41,42].

Graphene is a two-dimensional monolayer of sp2-hybridized carbon atoms spiked in a honeycomb lattice, which attracted further attention of many investigations owing to features like excellent electronic conductivity, affordability, and superior mechanical and chemical stability [43]. These are probably due to interlayer distance, specific surface area, doping and porous nature. In this regard, there are numerous advances including graphene foam formation [44], template-assisted assembly [45], graphene and carbon nanotube recombination [46] and heteroatom integration with graphene [47]. Among these, the electrochemical sensing activity of graphene-based electrodes has been reinforced following nitrogen (N) doping [48, 49], probably due to induction of more active sites via doping, and enlargement of specific surface area. Reduced graphene oxide (rGO)-anchored semiconductors exhibited greater catalytic performance when comparing with other materials [50, 51]. The copper oxide (CuO) as an intrinsically p-type semi-conductor, with a band gap of about 1.2 eV, excellent electrocatalytic and electrochemical properties and high availability, has been widely applied to fabricate electrochemical sensors [52,53,54].

Ionic liquids (ILs) are organic compounds that composed of organic cations with different anions, which are often found as liquid at ambient temperature. They have been extensively applied in electrochemical sensors because of specific physicochemical properties, some of which are fairly great ionic conductivity, poor vapor pressure, admirable chemical stability, impressive biocompatibility and stable electrochemical windows [55, 56].

Therefore, in this work, the CuO/N-rGO nanocomposite and IL modified CPE was used as electrochemical sensor to detect 2-aminophenol. A series of electrochemical tests like differential pulse voltammetry (DPV), cyclic voltammetry (CV), and chronoamperometry (CHA) have shown that N-rGO/CuO/ILCPE exhibited better electrochemical performance for 2-aminophenol through the synergistic effects of prepared N-rGO/CuO nanocomposite and IL. In addition, we investigated the performance of the N-rGO/CuO/ILCPE for simultaneous detection of 2-aminophenol and bisphenol A. Moreover, to evaluate the developed electrode, the identification of 2-aminophenol and bisphenol A in the real specimens was performed and the obtained results were satisfying.

2 Experimental section

2.1 Apparatus and chemicals

PGSTAT-302 N Autolab potentiostat/galvanostat (Eco Chemie, Netherlands) was a device to perform all electrochemical tests whose data were analyzed by General Purpose Electrochemical System (GPES) software. The electrochemical tests were performed in an electrochemical cell with three-electrode setup, containing N-rGO/CuO/ILCPE (working electrode (WR)), a platinum wire (counter electrode (CE)), and an Ag/AgCl (3.0 M KCl) (reference electrode (RE)). The pH values were measured by a digital pH meter (Metrohm type 713) equipped with a combined glass electrode in all solutions. Panalytical X’Pert Pro X-ray diffractometer equipped with Cu/Kα radiation (λ = 1.5418 nm) was employed to obtain X-ray diffraction (XRD) spectra to characterize the nanoparticles for crystal structures. Field emission-scanning electron microscopy FE-SEM images (MIRA3 scanning electron microscope; Tescan, Czech Republic) were analyzed to explore the N-rGO/CuO morphology. The as-fabricated products were examined for the chemical compositions using EDX plus FE-SEM. Bruker Tensor II spectrometer (Germany) was used to record the FT-IR patterns.

All materials used in this work had analytical grade. GO and Cu(II) acetate were bought from Sigma-Aldrich (Germany). 2-aminophenol, bisphenol A and other chemicals were bought from the Merck (Germany).

2.2 Preparation of N-rGO/CuO nanocomposite

In a facile preparation process of N-rGO/CuO nanocomposite, the GO (20 mg) was dissolved in deionized water (20 ml) under ultrasonic conditions, which results in the production of clear suspension. Then, the suspension was appended with 1.6 g of copper(II) acetate (Cu(OAc)2) while stirring vigorously for 50 min, followed by adding NH3·H2O (wt 25%) as dropwise while stirring continuously. The obtained mixture was placed in a Teflon Lined autoclave at a temperature of 180 °C for 12 h, followed by cooling down at an ambient temperature, washing with distilled water for several times. The result was N-rGO/CuO nanocomposite that was dried in an oven at 60 °C for 12 h.

2.3 Preparation of N-rGO/CuO/ILCPE

The N-rGO/CuO/ILCPE was prepared by grounding N-rGO/CuO nanocomposite and graphite powder (10:90 wt/wt%), followed by hand mixing with paraffin oil and IL (1-butyl-3-methylimidazolium hexafluorophosphate) (70:30 v/v%) in a mortar and pestle for at least 40 min until a homogenous wetted paste was obtained. The modified electrode was assembled by tightly pressing the resulting paste in the end-cavity of a substrate (glass tube). Then, the electrical contact was made by a Cu wire. Before each test, the surface of modified CPE was refreshed by pushing out a small portion of prepared paste and polishing it on a soft paper.

3 Results and discussion

3.1 Characterizations of the N-rGO/CuO nanocomposite

The FT-IR spectra of the GO and N-rGO/CuO nanocomposite is presented in Fig. 1. In the characteristic spectrum of GO, various functional groups in the structure include the vibration modes of O–H (3428 cm− 1), C=C (1577 cm− 1), C=O (1720 cm− 1) and epoxy C–O–C (1038 cm− 1) and phenolic C–O (1381 cm− 1). The characteristic peaks were related to a plenty of oxygen groups like carbonyl, carboxyl and hydroxyl groups on the GO surface. In the spectrum of N-rGO/CuO nanocomposite, the decline in the intensity of the characteristic bands in GO emphasized the reduction of GO into rGO. Moreover, the peak of absorption at 503 cm− 1 attributed to Cu–O stretching vibrations which emphasized that CuO was decorated on rGO sheets. The doping of N is further indicated by the appearance of a new peak in the vicinity of 1384 cm− 1, which was due to C–N stretching.

Fig. 1
figure 1

FT-IR spectrum of GO, and N-rGO/CuO nanocomposite

The morphology of as prepared N-rGO/CuO nanocomposites was analyzed by FE-SEM (Fig. 2). It is clearly can be seen in Fig. 2, the planar sheets of rGO with waved and wrinkled surface due to the nitrogen doping in rGO. Furthermore, the CuO NPs with an almost spherical morphology and a diameter between of 15 and 50 nm are homogeneously distributed on the surface of the N-rGO.

Fig. 2
figure 2

FE-SEM images of N-rGO/CuO nanocomposite at different magnifications

The EDX cleared the elemental or chemical formula of the synthesized N-rGO/CuO nanocomposite (Fig. 3), the results of which verified the existence of elements (C, N, Cu and O) in N-rGO/CuO nanocomposite.

Fig. 3
figure 3

The EDX spectum of N-rGO/CuO nanocomposite

The phase structure of N-rGO/CuO was identified by XRD. The XRD diffraction peaks of GO and N-rGO/CuO are shown in Fig. 4. GO displayed a diffraction peak (001) at 11.5° and a small peak (101) at 42.8°. The peaks at 2θ = 32.49°, 35.54°, 38.76°, 48.77°, 53.72°, 58.23°, 61.58°, 66.22°, 68.06°, 72.40°, and 75.187° as shown in Fig. 4 (N-rGO/CuO nanocomposite) corresponded to the planes (-110), (002), (111), (-202), (020), (202), (-113), (-311), (-220), (311) and (-222) related to CuO (JCPDS 00-045-0937), respectively. Considering these results, the CuO crystallization and nuclearization are evident within production. No peak of GO diffraction confirmed the GO reduction within hydrothermal reaction. No peak of graphene diffraction highlighted rGO rare restacking. Potent interfacial bonding of CuO NPs with N-rGO surface possessed a positive impact on preventing rGO restacking and preserving N-rGO structure [57]. The crystallite size (D) of CuO nanoparticles have been calculated from XRD by Debye Sheerer Equation:

$$D=K\lambda /\beta \cos \theta.$$

It was found that the average crystallite size of the CuO nanoparticles was determined by XRD spectrum about 17.7 nm.

Fig. 4
figure 4

XRD pattern of GO and N-rGO/CuO nanocomposite

3.2 Electrochemical behavior of 2-aminophenol at the N-rGO/CuO/ILCPE

The DPV method was recruited to study the effect pH value of electrolyte solution (0.1 M PBS) in different pH values (2–9) in the presence of 200.0 µM of 2-aminophenol on the N-rGO/CuO/ILCPE surface. The best catalytic performance occurred at pH 7. Therefore, pH 7 was selected as the optimum pH in the 2-aminophenol detection.

Figure 5 display CVs of electrochemical oxidation of 200.0 µM of 2-aminophenol on the bare CPE (curve a), N-rGO/CuO/CPE (curve b), ILCPE (curve c) and N-rGO/CuO/ILCPE (curve d). In accordance with results (Fig. 5), the 2-aminophenol oxidation was very poor on the bare CPE surface. However, at the surface of the N-rGO/CuO/ILCPE, the oxidation peak of 2-aminophenol occurred at lower potentials and had a higher anodic current compared to other CPEs. This result is probably due to synergistic impact of N-rGO/CuO nanocomposite and IL.

Fig. 5
figure 5

CVs of 200.0 µM 2-aminophenol at (a) bare CPE, (b) N-rGO/CuO/CPE, (c) ILCPE and (d) N-rGO/CuO/ILCPE in 0.1 M PBS of pH 7.0

3.3 Effect of the scan rate (υ) on the results

The CV method was used to explore the influence of scan rate on the oxidation of 2-aminophenol (400.0 µM) in 0.1 M PBS, as shown in Fig. 6. An elevation in the scan rate (10–600 mV/s) enhanced the oxidation peak current of 2-aminophenol, in addition to gradually shifting the anodic potentials to more positive values. Figure 6 (inset) emphasizes the proportionality of the anodic response current linearly to the scan rate square root, which shows controlled-diffusion processes for the electrocatalytic oxidation of 2-aminophenol on N-rGO/CuO /ILCPE.

Fig. 6
figure 6

Cyclic voltammetric responses of 400.0 µM 2-aminophenol in 0.1 M PBS (pH 7.0) at various scan rates (a: 10, b: 30, c: 70, d: 100, e: 300, and f: 600 mV/s) at N-rGO/CuO/ILCPE. Inset: Plot of the square root of the scan rate vs. the oxidation peak currents of 2-aminophenol

3.4 Chronoamperometric analyse

Chronoamperometry was considered for the investigation of 2-aminophenol electro-oxidation at the potential of 210 mV and various analyte concentrations in 0.1 M PBS (pH 7.0), as seen in Fig. 7. The current response of electroactive 2-aminophenol was described under a diffusion-limited electrocatalytic process using Cottrell’s equation [58]:

$$I = nFA{D^{1/2}}{C_{\text{b}}}{\pi ^{ - 1/2}}{t^{ - 1/2}}.$$

In this equation, n stands for the number of electron transfer exchanged per reactant molecule, F for the Faraday constant, Cb for 2-aminophenol concentration (mol/cm3), and D for diffusion coefficient (cm2/s). The plot of I versus t− 1/2 provided various linear curves for different 2-aminophenol contents of 0.1–2.0 mM (Fig. 7, inset A). The slope of each straight line against the 2-aminophenol content eventually made it possible to calculate the overall slope of the best-fit line (Fig. 7, inset B). At last, the overall slope in the Cottrell’s equation was utilized to estimate the mean D value, which was 4.2 × 10− 5 cm2/s.

Fig. 7
figure 7

The chronoamperograms obtained at N-rGO/CuO/ILCPE in 0.1 M PBS at pH of 7.0 for different concentrations of 2-aminophenol (a: 0.1, b: 0.5, c: 1.0, d: 1.5, and e: 2.0 mM of 2-aminophenol. Insets (A): plots of I against t− 1/2 (from chronoamperograms for the 2-aminophenol content of 0.1–2.0 mM); (B) plot of slope from straight lines against various 2-aminophenol contents

3.5 Calibration curve

The calibration curve for 2-aminophenol detection was achieved by DPVs for the oxidation of various 2-aminophenol concentrations in PBS (0.1 M, pH 7.0). Figure 8 illustrates the DPVs for the N-rGO/CuO/ILCPE toward various 2-aminophenol concentrations. Based on Fig. 8(inset), there was a linear elevation in the peak currents of 2-aminophenol oxidation by increasing its concentration. The results revealed the linear dynamic range from 0.1 µM to 700.0 µM, with a narrow limit of detection (LOD, S/N = 3) of 0.025 µM. Moreover, the Table 1 presented that the N-rGO/CuO/ILCPE was successfully used to determinate 2-aminophenol comparing with other sensors.

Fig. 8
figure 8

DPV response of 2-aminophenol at N-rGO/CuO/ILCPE in the concentration range 0.1–60.0 µM in 0.1 M PBS of pH 7.0 (a–h refers to 0.1, 0.5, 1.0, 5.0, 10.0, 20.0, 40.0, and 60.0 µM). Insets: A DPV response of 2-aminophenol in the concentration range 80.0–700.0 µM (i–p refers to 80.0, 100.0, 200.0, 300.0, 400.0, 500.0, 600.0, and 800.0 µM); B The calibration curve of DPV peaks against [2-aminophenol]

Table 1  A comparison between the obtained linear range and limit of detection of 2-aminophenol sensor in the present work and the other reported works

3.6 Detection of 2-aminophenol and bisphenol A simultaneously on N-rGO/CuO/ILCPE

The DPVs for detection of 2-aminophenol and bisphenol A simultaneously via N-rGO/CuO/ILCPE are shown in Fig. 9. The peaks at 160 and 480 V were related to the oxidation of 2-aminophenol and bisphenol A, respectively. The voltammetric peak currents of these analytes increased linearly with increasing their concentrations. Figure 9(inset A and inset B) show the corresponding calibration curves for 2-aminophenol and bisphenol A, respectively. The slope of 2-aminophenol calibration curve (0.2675 µA/µM) was almost equal to that without bisphenol A (0.2681 µA/µM, see previous section), indicating the applicability of N-rGO/CuO/ILCPE for detection the concentrations of 2-aminophenol in the presence of bisphenol A.

Fig. 9
figure 9

The DPVs of the N-rGO/CuO/ILCPE in 0.1 M PBS at pH equal to 7.0 containing different concentrations of 2-aminophenol and bisphenol A. Notably, ak corresponded to 0.1 + 0.1, 5.0 + 5.0, 20.0 + 20.0, 60.0 + 60.0, 100.0 + 100.0, 200.0 + 200.0, 300.0 + 300.0, 400.0 + 400.0, 500.0 + 500.0, 600.0 + 600.0 and 700.0 + 700.0 µM of 2-aminophenol and bisphenol A, respectively. Inset A The Ip plot vs. 2-aminophenol concentration. Inset B The Ip plot vs. bisphenol A concentration

3.7 Interference study

The influence of numerous substances on the determination of 2-aminophenol was investigated in 0.1 M PBS (pH 7.0) containing 30.0 µM 2-aminophenol in the presence of possible interfering substances. The results show that 600-fold K+, Ca2+, Mg2+, Al3+, NH4+, Cl, Br and SO42−, 25-fold phenol, P-nitrophenol, O-nitrophenol and O-phenylenediamine, 10-fold hydroquinone, catechol, and resorcinol did not show any significant change in the peak current of 2-aminophenol. These results demonstrated that the N-rGO/CuO/ILCPE provides a selective sensor toward the determination of 2-aminophenol.

3.8 Analytical application

The 2-aminophenol and bisphenol A detection in the water samples was performed using N-rGO/CuO/ILCPE sensor. The determination of these analytes was carried out according to the standard addition method for five times in each concentration. Attained findings are summarized in Table 2, the recovery is between 96.9 and 103.6%, and the relative standard deviations (RSDs) are all less than or equal to 3.6%. According to Table 2, the acceptable resultsd confirm good performance ability of N-rGO/CuO/ILCPE for the determination of 2-aminophenol and bisphenol A in water samples.

Table 2 Applicability of N-rGO/CuO/ILCPE for sensing different concentrations (µM) of 2-aminophenol and bisphenol A spiked in real specimens (n = 5)

4 Conclusions

In this work, the N-rGO/CuO nanocomposite was synthesized through a simple hydrothermal method and characterized by various techniques, for example, FT-IR, FE-SEM, EDX, and XRD. Then, the prepared N-rGO/CuO/ILCPE was successfully used for 2-aminophenol detection. The proposed sensor displayed excellent electrocatalytic activity toward the electrochemical detection of 2-aminophenol by reducing the overvoltage and increasing the signal. The linear calibration curve was seen by drawing a plot of peak currents versus different 2-aminophenol levels (0.1–700.0 µM), presenting a low limit of detection (0.025 µM). Two clear and well-separated voltammetric peaks along with the remarkably increased electro-oxidation currents of 2-aminophenol and bisphenol A were obtained on the modified electrode (N-rGO/CuO/ILCPE) in DPV measurements. Furthermore, the concentration of 2-aminophenol and bisphenol A were assayed in water samples, the recoveries were from 96.9 to 103.6%.