1 Introduction

The fast growth of industrialization globally has made it difficult to find adequate land for secure construction, as suitable land has become scarce. Currently, finding firm ground for a building is a significant challenge. Consequently, due to the aforementioned reasons, the utilization of soft or weak soil masses with inadequate bearing capacity is now being executed after undergoing necessary modifications. Several studies have used a variety of approaches to increase the bearing capability of the soil when a footing is placed at the top of a weak soil stratum. The technique removes the soft soil already present up to a shallow depth and replaces it with granular soil with horizontal reinforcement layers. Additionally, the ground substituted with reinforced soil could be compacted at a higher density to gain the advantage of more frictional resistance. If the removed soil is very loose, it might be altered with well-graded soil before being strengthened and re-compacted. Under such circumstances where a non-homogenous/stratified soil layer supports the superstructure, the bearing capacity assessment is essential as there are variations in the soil constituents within a section of the earth strata (Gupta et al. 2021).

Prior research has conducted comprehensive investigations into the load-bearing capacity of foundations on homogeneous soil deposits (Terzaghi 1943; Meyerhof 1963; Lai et al. 2022a). Moreover, researchers have examined the behavior of footings lying above the reinforced earth, including the assessment of the bearing capacity ratio (BCR) (i.e., the ratio of reinforced soils to unreinforced soil’s ultimate bearing capacity) on shallow foundations (Meyerhof and Hanna 1978; Hanna and Meyerhof 1980; Akinmusuru and Akinbolade 1981; Fragaszy and Lawton 1984; Mandal and Sah 1992; Srinivasa et al. 1993; Jaiswal et al. 2021, Keawsawasvong et al. 2022a; Jaiswal et al. 2022a). A small-scale laboratory model test was conducted to compare and study the performance of granular fill overlays, with and without geogrid reinforcement, on a soft soil layer subjected to foundation load. The results of the test indicated a considerable enhancement in the ultimate bearing capacity ratio and a significant decrease in foundation settlement. Furthermore, Cicek and Guler (2015) calculated the ultimate carrying capacity of strip footings placed on geosynthetic reinforced sand soils by the limit equilibrium method as well as the finite element method. The majority of studies have reported an increase in the load-bearing capacity of the underlying soil due to the incorporation of horizontal reinforcement layers. Nevertheless, for in-situ installation of these reinforcement layers, the weak soil layer must be excavated to a shallow depth and then re-compacted after placing the reinforcement layers at the appropriate spacing.

The homogeneity of soil strata is an uncommon phenomenon in nature. The evaluation of multi-layered soil formations is carried out using a combination of experimental methods and analytical techniques, including limit equilibrium, limit analysis, and various numerical methods (Hanna 1987; Michalowski and Shi 1995; Dewaikar and Mohapatra 2003; Kumar and Sahoo 2013; Chakraborty and Kumar 2014a; Chakraborty and Kumar 2014b; Kumar and Chakraborty 2015; Ukritchon and Keawsawasvong 2020; Keawsawasvong et. al. 2022b; Rai et. al. 2022). Michalowski and Shi (1995) employed the kinematic approach of limit equilibrium analysis to assess the load-bearing capacity of footings supported on a two-layer soil system, with the results of the study being applicable only to a specific scenario where the footing was placed on a granular soil layer overlying a clay layer. Shiau et al. (2003) utilized finite element limit analysis to examine the load-bearing capacity of a sand layer placed on top of the clay layer, analyzing the impact of changes in the model's geometry and strength parameters. Ghazavi and Eghbali (2008) presented a simple analytical technique based on limit equilibrium to compute the load-bearing capacity of shallow footings on two-layer granular (sandy) soil formations. Despite previous studies on layered soil formations, a comprehensive understanding of the performance of structures constructed on such soil strata is still lacking. Thus, the objective of the current study is to examine the ultimate bearing capacity (UBC) of soil strata incorporating a weak, compressible clay layer, through the use of adaptive finite element limit analysis (AFELA). The layered soil strata are subjected to a gradually increasing uniformly distributed vertical load in the form of a footing. The numerical model is created by a finite element-based computational tool and limit analysis and multiplier elastoplastic analysis are performed to understand the variation in the UBC of the footing, the change in the failure patterns, and the load-settlements behavior of the foundation due to the presence of a compressible clay layer. The governing parameters for the computational analysis, namely the normalized depth of the compressible layer (H/B), internal angle of friction of cohesionless soil (ϕ), and undrained shear strength (Su), are varied between 0.5 to 7, 30º to 45°, and 12 kPa to 192 kPa, respectively (Ameratunga et al. 2016). A total of 210 numerical models are simulated to conduct a comprehensive examination of the ultimate bearing capacity (UBC) of the strip footing. The examination aims to determine the variation in the bearing capacity ratio (BCR), the potential failure mode of the footing, and the settlement of the footing. The nonlinearities and interactions between variables are identified using a data science technique called "Multivariate Adaptive Regression Spline" (MARS) and a proposed empirical equation is developed to estimate the UBC under the specified conditions. Furthermore, the impact of the input parameters (H/B, ϕ, Su) on UBC is examined by the sensitivity analysis in the MARS model.

1.1 Problem Statement

The current study intends to evaluate BCR for different combinations of (ϕ) and (Su) as shown in Fig. 1.

Fig. 1
figure 1

Flowchart describing various parameters considered for the present analysis

For the aforementioned, a two-dimensional finite element-based numerical computational tool, Optum G2 (2020), is used to model a strip footing, resting on a sand bed containing a compressible layer of clay. The normalized depth of the clay layer (H/B) is varied as H/B = 0.5, 1, 2, 3, 4, 5. Consequently, the study assesses the influence of H/B, ϕ and Su on the settlement of the foundation and the extent of the failure plane beneath it, in addition to the assessment of the BCR of the footing on the layered soil. With this large number of presented results and the MARS model, the findings shall be beneficial for the geotechnical engineers to design a safer structure resting on soil strata containing a weak clay layer.

2 Numerical Modeling

Figure 2 illustrates the typical arrangement of the layered soil strata for the numerical simulations considered in the present study. A detailed stratified soil system with geometrical configuration is shown in Fig. 2.

Fig. 2
figure 2

Geometrical representation of the layered soil strata considered in the present study with load and boundary conditions

Here, a weightless and rigid strip footing of width, B (1m) is placed on the layered soil system, which is subjected to a uniformly distributed load. A clay layer of 1m thickness is sandwiched in between the sand layers in the layered soil system. The distance between the clay layer from the bottom of the footing surface is represented by H. The abovementioned distance is normalized with the width of footing and represented as the normalized depth of the clay layer, H/B. The internal friction angle of the sand layer and the undrained shear strength of clay are represented by the ϕ and Su, respectively. The sand layer is assumed to follow the Mohr-Coulomb failure criterion, whereas the clay layer follows the Tresca failure criterion. To present the noted results, a dimensionless bearing capacity ratio (BCR) is evaluated, which is defined as the ratio of the ultimate bearing capacity of the layered soil to the ultimate bearing capacity of homogenous sand strata.

$$BCR = \frac{{Ultimate\,bearing\,capacity\,of\,layered\,soil}}{{Ultimate\,bearing\,capacity\,of\,homogenous\,sand\,strata}}$$
(1)

Figure 3 illustrates the finite element model of a compressible clay layer sandwiched between two sandy soil strata. The dimensions of the soil strata are 10m in depth and 15m in width. The normalized depth of the clay layer (H/B) is varied along with other engineering properties of sand and clay. The boundary conditions are established with standard fixities, where the bottom boundary is restrained from movement in all directions and the vertical boundaries are restrained horizontally (Jaiswal and Chauhan 2021a, b). The boundaries of the finite element model are positioned away from the predicted failure zones to minimize any impact on the shear failure patterns and settlement behavior of the sand and clay layers (Jaiswal and Chauhan 2021c, d).

Fig. 3
figure 3

Finite element model showing a strip footing resting on layered sand with the presence of a compressible clay layer

In numerical analysis, the size of the mesh element plays a vital role as the optimum average mesh size and the number of elements are evaluated to increase the accuracy of calculating stresses and minimize errors (Keawsawasvong and Ukritchon 2019; Ukritchon and Keawsawasvong 2019; Ukritchon et al. 2019; Keawsawasvong and Ukritchon 2020; Ukritchon et al. 2020; Keawsawasvong and Lai 2021; Yodsomjai et al. 2021; Lai et al. 2022b, 2022c; Keawsawasvong et al. 2022c). In the numerical analysis, the mesh element size is a crucial factor. To achieve an optimal average mesh size and the appropriate number of elements, the aim is to enhance the accuracy in the calculation of stresses while minimizing errors. The accuracy of the results is ensured by conducting a sensitivity analysis, in which the number of mesh elements is varied from 5000 to 20000 (Srivastava and Chauhan 2020; Chauhan et al. 2022). It is concluded that using more than 10,000 elements in the mesh ensures stability in the results with only negligible variations. Therefore, the optimum number of elements for the models used in the current study is determined to be 10,000 (Jaiswal et al. 2022b; Ojha et al. 2021; Banyong and Keawsawasvong 2022). Sloan (2013) stated that the stability analysis using the AFELA based on the limit analysis theory requires only the conventional strength parameters such as cohesion and friction angle but does not require the deformation parameters such as Poisson’s ratio and Young’s modulus. Therefore, FELA differs from the conventional displacement-based finite element analysis. However, for the parameters mentioned earlier, a multiplier elastoplastic analysis has also been performed in order to analyze the load-settlement behavior of the footing.

Fig. 4
figure 4

BCR vs ϕ at varied H/B for a compressible layer having different undrained shear strength and friction angle

3 Results and Discussion

This section provides a summary and discussion of the key findings obtained through numerical simulations. The results, depicted in graphical forms, assess the bearing capacity ratio (BCR) of the strip footing with variations in the governing parameters. Further analysis of the load-settlement curves and shear failure patterns of the various cases is conducted and discussed in subsequent sections.

3.1 Effect of H/B on BCR

Figure  shows the variation of BCR for varying H/B for the considered range of ϕ and Su. For a clay layer situated near the ground level, i.e., H/B = 0.5, the highest BCR is obtained at Su = 192 kPa and the lowest value of BCR is obtained at Su = 12 kPa. Throughout the variation of Su, the bearing capacity ratio of the footing decreases by 81.25% of its original value. Thus, it can be stated that the BCR of the strip footing is directly proportional to the Su when the compressible layer is situated close to the foundation. However, the effect of ϕ, is considerably different on the BCR. The greatest value of BCR is obtained when the clay layer is sandwiched in sandy soil having a lower friction angle, i.e., ϕ = 33º and the minimum when the sandy soil has a higher friction angle, i.e., ϕ = 45°. The BCR decreases by 62.5% as the value of ϕ is increased from 33° to 45°. Similarly for H/B = 1, the highest BCR is obtained at Su = 192 kPa and the lowest value of BCR is obtained at Su = 12 kPa with the bearing capacity ratio of the footing being decreased by 76% from the highest value. The highest value of BCR, in this case, is gained at ϕ = 33° and the lowest at ϕ = 45° where the BCR decreases by 28.57% as the value of ϕ is increased. For H/B = 2 and 3, it is observed that the highest magnitude of BCR is 1.0 in all the cases, which gets lower due to the effect of Su and ϕ. For H/B = 4 and 5, no effect of Su and ϕ is at all observed and the BCR is constant at 1.0 except for the lowermost value of Su (very soft clay) and the highest value of ϕ, considered in the study. Thus, apart from the cases of the extremum, the BCR is invariable, as if the presence of the clay layer does not affect the ultimate bearing capacity of the layered soil strata.

3.2 Effect of S u on BCR

From Fig. 5, it can be observed that the magnitude of the BCR is highly dependent on the undrained shear strength of the soil. BCR is observed to be less than one for all positions and sandy soils when Su < 96 kPa. It is observed that when the position of the clay layer is closer to the footing, the BCR varies concavely upwards when the magnitude of Su is higher. However, this variation is quite minuscule when the internal friction is relatively low. A diverse trend is further noticed, where the BCR becomes greater than unity at lower H/B ratios at smaller angles of internal friction, i.e., for Su ≥ 96 kPa. This observed behavior can be attributed to the fact that the influence of the clay layer with a higher undrained shear strength dominates over the sand layer with a smaller angle of internal friction. The presence of a clay layer with a higher undrained shear strength provides additional strength to the soil strata.

Fig. 5
figure 5

BCR vs H/B at varied ϕ for different soil strata at different H/B ratios

For Su = 192 kPa, the highest BCR is obtained at H/B = 1 and the lowest value of BCR is obtained at Su = 12 kPa. Throughout the variation of Su, the bearing capacity ratio of the footing decreases by 37.5 % of its original value when H/B varies between 0.5 to 1 for the sand with internal friction angle, ϕ = 33°. At the higher ratios of H/B, the value of BCR is invariable at 1.0, irrespective of the Su and ϕ. This supports the notion that beyond a specific depth, the impact of weak clay strata becomes insignificant, and the strength of the strata is not influenced by it. It is worth noting that the internal friction angle plays a distinct role, as it has been observed that a lower friction angle of the sand layer leads to a higher BCR for all Su and ϕ variations. The BCR decreases by 75% from its maximum value with the variation of ϕ.

3.3 Effect of ϕ on BCR

Figure 6 shows the variation of BCR for varying ϕ for the considered range of H/B and Su. For a constant value of the angle of internal friction ϕ, at particular Su, the BCR increases with an increase in H/B ratio and tends to achieve unity at a certain H/B ratio. If the clay layer having a greater undrained shear strength is taken into consideration, then the BCR decreases with an increase in the H/B ratio and tends to reach unity. On increasing the dry density of sand i.e., increasing ϕ, the curve representing the magnitude of the BCR changes its course from an upward trend to a downward trend. At the lowest magnitude of ϕ, the BCR is constant except for the H/B ≤ 2. However, as the ϕ increases, more deviation from the constant value of BCR are noted at different H/B ratios and Su as depicted in Fig. 5. For loose to medium dense sand strata, i.e., ϕ ≤ 36°, BCR is noted to be higher than unity when the clay layer having is Su ≥ 96 kPa is located H/B ≤ 1. Additionally, when the internal friction angle of soil strata increases (i.e., ϕ ≥ 39°), the BCR is consistently less than unity with the presence of a clay layer, regardless of its location or the undrained shear strength of the clay layer. This observation highlights the fact that the inclusion of clay between a medium-dense sand layer reduces the bearing capacity of the foundation relative to soil strata without clay, regardless of the clay layer’s location or undrained shear strength.

3.4 Load-Settlement Behaviour

This section discusses a few typical load settlement curves obtained from the elastoplastic analysis to assist in analyzing the load-carrying capacity and the consequent settlement of the strip footing.

Fig. 6
figure 6

BCR vs H/B at varied Su for particular soil strata

To study the effect of the variation of the position of a clay layer on bearing capacity, the variation of the load-settlement curve for Su = 48 kPa and ϕ = 36° is shown in Fig. 7. It has been observed that when soil strata consist solely of sand, the settlement of the footing is substantial, and its bearing capacity is correspondingly high. However, when a clay layer is interposed in the soil strata, the behavior of the load-settlement curve undergoes a significant change when H/B values are equal to 0.5 and 0.1, with the footing experiencing failure at a significantly lower load compared to the scenario of sand-only soil strata. The observed behavior is a result of the presence of a compressible clay layer at shallow depth, leading to failure at a comparatively lower load-carrying capacity (approximately 30–60% lower than the case with no clay). As H/B increases, the load-settlement behavior takes on a shape similar to the case soil strata consisting solely of sand. Interestingly, the ultimate load of the footing with H/B = 2.0 was found to be slightly higher than the case with no clay. However, a further increase in the distance of the clay layer from the footing results in a decrease in the ultimate failure load. Based on this observed behavior, it can be deduced that there is a critical depth at which the presence of a clay layer with a specific undrained shear strength may enhance the load-bearing capacity of the footing compared to soil strata consisting solely of sand. The location of this critical depth, however, depends on the interaction between sand and clay strengths.

Fig. 7
figure 7

Load-settlement curve for ϕ =36° and Su= 48 kPa

3.4.1 For H/B = 4 and ϕ = 36

In order to study the effect of the undrained shear strength on the bearing capacity of the footing, the variation of the load-settlement curve for H/B = 4 and ϕ = 36° is shown in Fig. 8. The load settlement curve is not affected by the clay's stiffness, represented by its undrained shear strength, except for very soft clay with a low undrained shear strength of 12 kPa. However, the maximum load-bearing capacity and the settlement at failure are almost the same for all the clays (Su) considered in the present study. Therefore, for H/B = 4, it can be concluded that parameters like ϕ and Su have no noticeable impact on settlement and load-bearing capacity. This is likely due to the dominance of sand over clay, which negates the effect.

Fig. 8
figure 8

Load-settlement curve for ϕ = 36° and H/B = 4

3.4.2 For H/B= 4 and S u =48 kPa

To study the effect of the internal friction of angle on the behavior of the load-settlement curve, a variation of load-settlement for Su = 48 kPa and H/B = 4 for ϕ ranging from 30° to 45° is shown in Fig. 9. The results of the analysis indicate that an increase in the value of ϕ leads to an improvement in the soil strata's load-bearing capacity, even when a clay layer is present. This behavior is likely due to the presence of the clay layer at a depth of H/B = 4, which does not significantly impact the footing's settlement behavior under increasing loads. However, it should be noted that the differences in settlement values at failure are not substantial.

Fig. 9
figure 9

Load-settlement curve for Su = 48 kPa and H/B = 4

The results show that as ϕ increases, the footing's settlement ratio increases by 9.6% from its initial value (lowest ϕ). This is likely due to the high H/B ratio, which reduces the impact of the clay layer. Additionally, as the internal friction angle increases, there is a distinct change in the load-bearing capacity at the yield point.

3.5 Progression of the Failure Planes

The variation of the failure pattern of the strip footing on the layered soil strata with respect to the changing values of Su is shown in Fig. 10. The extent of the failure plane reaches up to the mid of the clay layer when Su is lower in magnitude. The formation of a high-stress zone is noted at the boundary of the footing which follows a symmetrical pattern at each end. The failure path follows a triangular wedge at both ends that coincide in the center at the clay layer and extends upwards again towards the sand layer. However, with an increment in the values of Su, it is noted that the extent of the failure plane below the footing is reduced. An interesting fact is also noteworthy that the extent of the failure plane surrounding the footing depends on the undrained shear strength of the clay layer, i.e., the widest failure plane is observed at lowest Su = 12 kPa and the smallest failure plane is obtained when a clay layer has a maximum magnitude of the undrained strength, i.e., Su = 192 kPa.

Fig. 10
figure 10

Failure pattern of soil strata (ϕ = 36°) having a clay layer at H/B = 0.5 with varying undrained shear strength; (a) Su = 12 kPa; (b) Su = 48 kPa; (c) Su = 96 kPa; (d) Su = 144 kPa; and (e) Su = 192 kPa

Figure 11 illustrates the failure path observed at H/B = 0.5 and Su = 48 kPa, where the clay layer is closest to the footing among the simulations conducted in this study. The variation in ϕ has a significant impact on the failure plane's path. As the ϕ increases, the extent and depth of the failure plane also increase, encompassing a larger area below the footing. A higher stress zone is noted below the ends of the footing, with the intensity of the stress zone becoming stronger as ϕ increases. The largest failure plane is observed when ϕ = 45°, and the lowest magnitude is seen when ϕ = 30°.

Fig. 11
figure 11

Failure pattern of a footing resting over cohesionless soil strata with the presence of a clay layer (Su = 48 kPa) at H/B = 0.5 for different internal friction angle (ϕ) of (a) ϕ = 30°; (b) ϕ = 33°; (c) ϕ = 36°; (d) ϕ = 39° (e) ϕ = 42°; and (f) ϕ = 45°

Figure 12 depicts the variation in the failure planes as the H/B ratio is changed from 0.5 to 7. The position of the clay layer can be seen to affect the formation of the failure plane beneath the strip footing. When the clay layer is positioned at H/B = 0.5, the formation of the failure plane begins below the footing with high-stress zones towards the end, but it is small and somewhat obstructed by the presence of the clay layer. As the H/B ratio increases up to 7, the magnitude of the failure increases, becoming more pronounced. The high-stress zones are also extended, and two similar wedges converge at the center. It can be concluded that the clay layer does not facilitate the full development of the failure zone.

Fig. 12
figure 12

Failure pattern of cohesionless soil (ϕ = 30°) with a presence of clay layer (Su = 48 kPa) at a normalized depth of (a) H/B = 0 (NO CLAY); (b) H/B = 0.5; (c) H/B = 1; (d) H/B = 2; (e) H/B = 3 (f) H/B = 4; (g) H/B = 5; (h) H/B = 6; (i) H/B = 7

Figure 13 represents the variation of the failure plane due to varied H/B ratios at constant ϕ = 45° and Su = 48 kPa. As the maximum value of ϕ (very dense) is considered in the present study, hence this particular configuration displays some interesting insights. When there is no clay layer in the considered soil strata, high-stress zones occur beneath the strip footings, proceed in the form of wedges, and further coincide with each other. At this high value of ϕ and clay layer at H/B = 2 to 4, the failure planes are not obstructed due to the presence of the clay layer instead they proceed into it. Although the presence of the clay layer is at a certain vertical distance yet it is noticed that the lower stress zones extend up to a higher depth and a similar coinciding of identical wedge formation happens. For H/B = 5 and 6, the clay layer does not affect the failure plane, and a similar pattern as mentioned before for the progression and coinciding is observed.

Fig. 13
figure 13

Failure pattern for varied H/B ratios at ϕ = 45° and Su = 48 kPa with the presence of clay layer at a normalized depth of (a) H/B = 0 (NO CLAY); (b) H/B = 0.5; (c) H/B =1; (d) H/B = 2; (e) H/B = 3 (f) H/B = 4; (g) H/B = 5; (h) H/B = 6; and (i) H/B =7

4 Sensitivity Analysis, Empirical Formula, and Relative Importance Index from MARS Model

Each input parameter in the initial design of the numerical model is significant since it can be applied in further design optimization of the model. Furthermore, using the empirical equation instead of the numerical model can reduce the cost and time for practical engineering. Hence, the Multivariate Adaptive Regression Spline (MARS) model is adopted in this study for sensitivity analysis and to establish an empirical equation.

MARS model is also identified as an auto mesh regression model. It transfers the complex non-linear regression to a multiple linear regression model, as shown in Fig. 14. MARS progress contains two main steps. Firstly, they procedure a number of linear regression models which are mathematically presented by linear basic functions as shown in Equation (2). Two regression lines are connected by Knot. The position of Knot is determined using the adaptive regression algorithm. In the later step, MARS deletes the least effective linear regression models by using a pruning algorithm based on Generalized Cross validation (GCV) (Shiau and Keawsawasvong 2022). The value of GCV can be determined by Equation (3)

$$BF = \max \;(0,\;x - t) = \left\{ \begin{gathered} x - t\;\;\;{\text{if}}\;x \ge \;t \hfill \\ 0\;\;\;\;\;\;\;{\text{otherwise}} \hfill \\ \end{gathered} \right.$$
(2)

where t is a Knot value and x is an input variable

$$GCV = \frac{RMSE}{{\left[ {1 - {{\left( {N - hN} \right)} \mathord{\left/ {\vphantom {{\left( {N - hN} \right)} R}} \right. \kern-0pt} R}} \right]^{2} }}$$
(3)

where RMSE is the root mean square error for the training dataset, h is the penalty factor, and R is the number of data points.

Fig. 14
figure 14

The idea of the MARS model

To build the empirical equation describing the relationship between the input and output parameters, the MARS model merges all linear basic functions (BFs). The form of nth equation is shown in Eq. (4), where a0 is a constant, N is the number of BFs, gn is the nth BF, an is the nth coefficient of gn. Note that increasing the number of data sections, in other words, the number of basic functions, can increase the accuracy of the MARS model (Yodsomjai et al. 2022; Jearsiripongkul et al. 2022; Sirimontree et al. 2022).

$$f(x) = a_{o} + \sum\limits_{n = 1}^{N} {a_{n} g_{n} } (X)$$
(4)

In this study, all numerical results are used as the training data for MARS model. In detail, the data set includes 210 UBC values from numerical analysis corresponding with 210 datasets of input dimensionless parameters (H/B, ϕ, Su). The optimal model is selected by considering the variation of two classical statistical standards, i.e., Root Mean Squared Error (RMSE) and coefficient of determination (R2) due to the changing of the number of basic functions. In that, the R2 is in the range of 0 to 1. The R2 close to 1 indicates that the exact agreement between prediction from MARS model and the target value is obtained while R2 close to 0 is inverse meaning. RMSE is used to determine errors between prediction and target value. RMSE value is smaller which shows a model with higher accuracy.

As results shown in Fig. 15, it can be seen that the RMSE and R2 are changed due to the variation of the number of basic functions. RMSE reduces while R2 is closed to 1 when the number of basic functions rises. The variations of RMSE and R2 become stable when the number of basic functions is 50. So, MARS model with 50 basic functions is used for the next analysis. The basic functions of the optimal MARS model are shown in Table 1.

Fig. 15
figure 15

Influence of variation of BF on the accuracy of MARS models

Table 1 Basic functions from the optimal model

Figure 16 shows the comparison between UBC determined from the proposed empirical equation and numerical results. It can be seen that UBC values from the proposed equation are in well agreement with those from numerical results with a high R2 of 99.42%. This means that the proposed equation can be a useful tool for practical engineering to predict the UBC as well as the bearing capacity of layered soil with an interbedded weak clay layer. The proposed empirical equation is shown in Eq. 5.

$$\begin{gathered} {\text{UBC }} = { 279}.{251 } + { 41}.{6155 } \times {\text{ BF3 }} + { 251}.{365 } \times {\text{ BF4 }} + \, 0.{753529 } \times \hfill \\ {\text{BF5 }} - \, 0.{78}0{422 } \times {\text{ BF6 }} - \, 0.{6}0{8465 } \times {\text{ BF7 }} - \, 0.{264262 } \times {\text{ BF8 }} - { 83}.{7718 } \times \hfill \\ {\text{BF9 }} - \, 0.{619}0{37 } \times {\text{ BF11 }} + { 1}.0{1617 } \times {\text{ BF12 }} + \, 0.{897852 } \times {\text{ BF13 }} - \, 0.{5}0{5}0{36 } \times \hfill \\ {\text{BF14 }} + { 1}00.{665 } \times {\text{ BF15}} - {6}.{56242 } \times {\text{ BF18 }} + { 429}.{443 } \times {\text{ BF19 }} + { 12}.{9417 } \times \hfill \\ {\text{BF21 }} + { 3}.{48765 } \times {\text{ BF23 }} - { 5}.{95136 } \times {\text{ BF24 }} - { 1}.{16}0{95 } \times {\text{ BF25 }} - { 5}.{77517 } \times \hfill \\ {\text{BF26 }} + { 1}.{38747 } \times {\text{ BF27 }} - { 72}.{9691 } \times {\text{ BF29 }} - { 21}.{3214 } \times {\text{ BF31 }} + \, 0.{912378 } \times \hfill \\ {\text{BF33 }} - \, 0.{36}0{997 } \times {\text{ BF35}} 0.{243619 } \times {\text{ BF37 }} + { 1}.0{4753 } \times {\text{ BF38 }} + { 1}0.{8786 } \times \hfill \\ {\text{BF39 }} + { 22}.0{313 } \times {\text{ BF4}}0 \, + \, 0.{32}0{371 } \times {\text{ BF42 }} + { 71}.{312 } \times {\text{ BF43 }} - \, 0.{5}0{9995 } \times \hfill \\ {\text{BF45 }} + \, 0.0{7}0{1428 } \times {\text{ BF46 }} + { 178}.{711 } \times {\text{ BF48}} \hfill \\ \end{gathered}$$
(5)
Fig. 16
figure 16

Comparison between proposed empirical equation and numerical results

The MARS model employs the relative important index (RII) to assess the significance of each parameter. RII is computed based on the difference in the generalized cross-validation (GCV) values between the pruned and over-fitted versions of the model (as described in Gan et al. 2014 and Steinberg et al. 1999). The score relative importance index (RII) is determined by Eq. 6:

$$RII(i) = \frac{\Delta g(i)}{{\max \left\{ {\Delta g(i),\Delta g(2),\Delta g(3),....,\Delta g(n)} \right\}}}$$
(6)

where Δg is the increase in GCV when ith parameter is deleted. The higher the GCV rises, the more significant the deleted parameter.

The results of the sensitivity analysis are obtained in Fig. 17. It is noted that RII of 100% means that the corresponding parameters in the most important ones. As a result, ϕ is the most important parameter while H/B and Su are scored later with RII values of 57.9% and 26.91%, respectively. These results signify that the three investigated dimensionless parameters are highly essential and cannot be neglected in determining the bearing capacity of layered soil with an interbedded weak clay layer.

Fig. 17
figure 17

Relative important index of the dimensionless parameters

5 Conclusions

The present study aims to investigate the impact of a compressible clay layer situated within soil strata on the ultimate bearing capacity of a strip footing. The depth of the compressible layer (H/B) and the internal angle of friction of sand (ϕ) as well as the undrained shear strength of the clay layer (Su) are varied. A finite element analysis is carried out to assess the bearing capacity ratio (BCR). The numerical model underwent limit and elastoplastic analysis and the shear failure patterns beneath the footing are analyzed. The Multivariate Adaptive Regression Spline (MARS) model is employed to develop a correlation equation that portrays the non-linearities and interactions between variables. The results are compared to numerical and empirical data, and the RII of the parameters is evaluated.

  1. 1.

    The outcomes from the study shows that when the compressible clay layer is located close to the footing (H/B = 0.5), the BCR is proportional to the undrained shear strength of the clay layer. The highest BCR is obtained at Su = 192 kPa and the lowest BCR is obtained at Su = 12 kPa. The BCR is also proportional to Su when the compressible layer is close to the foundation. The highest BCR is obtained when the clay layer is situated between sandy soil with a lower friction angle (ϕ = 33º) and the minimum is obtained when the sandy soil had a higher friction angle (ϕ = 45º). However, for higher H/B = 4 and 5, no effect of undrained shear strength and internal friction angle is observed, and the BCR is noted to be constant at 1.0.

  2. 2.

    The study also found that the magnitude of the BCR is highly dependent on the undrained shear strength of the soil. The BCR became greater than unity at lower H/B ratios and lower internal friction angles, which might be due to the clay layer with a higher undrained shear strength overpowering the sand layer with a smaller internal friction angle. The impact of the horizontal clay layer on the load-carrying capacity diminished as the H/B ratio increased.

  3. 3.

    The study concluded that the development of the failure envelope below the footing was governed by the location of the clay layer and the relative stiffness between the sand and clay layer.

  4. 4.

    The MARS model is used to propose an empirical equation for determining the bearing capacity of layered soil with an interbedded weak clay layer, with an R2 value of 99.42. The internal friction angle (ϕ) is found to be the most important input parameter with RII = 100, while H/B and Su have RII values of 57.9% and 26.91%, respectively.

6 Declaration