Abstract
The cross-sectional shape of the aortic root is cloverleaf, not circular, raising controversy regarding how best to measure its radiographic “diameter” for aortic event prediction. We mathematically extended the law of Laplace to estimate aortic wall stress within this cloverleaf region, simultaneously identifying a new metric of aortic root dimension that can be applied to clinical measurement of the aortic root and sinuses of Valsalva on clinical computerized tomographic scans. Enforcing equilibrium between blood pressure and wall stress, finite element computations were performed to evaluate the mathematical derivation. The resulting Laplace diameter was compared with existing methods of aortic root measurement across four patient groups: non-syndromic aneurysm, bicuspid aortic valve, Marfan syndrome, and non-dilated root patients (total 106 patients, 62 M, 44 F). (1) Wall stress: Mean wall stress at the depth of the sinuses followed this equation: Wall stress = BP × Circumscribing circle diameter/(2 × Aortic wall thickness). Therefore, the diameter of the circle enclosing the root cloverleaf, that is, twice the distance between the center, where the sinus-to-commissure lines coincide, and the depth of the sinuses, may replace diameter in the Laplace relation for a cloverleaf cross-section (or any shaped cross-section with two or more planes of symmetry). This mathematically derived result was verified by computational finite element analyses. (2) Diameters: CT scan measurements showed a significant difference between this new metric, the Laplace diameter, and the sinus-to-commissure, mid-sinus-to-mid-sinus, and coronal measurements in all four groups (p-value < 0.05). The average Laplace diameter measurements differed significantly from the other measurements in all patient groups. Among the various possible measurements within the aortic root, the diameter of the circumscribing circle, enclosing the cloverleaf, represents the diameter most closely related to wall stress. This diameter is larger than the other measurements, indicating an underestimation of wall stress by prior measurements, and otherwise provides an unbiased, convenient, consistent, physics-based measurement for clinical use.
Graphical abstract
“Diameter” applies to circles. Our mathematical derivation of an extension of the law of Laplace, from circular to cloverleaf cross-sectional geometries of the aortic root, has implications for measurement of aortic root “diameter.” The suggested method is as follows: (1) the “center” of the aortic root is identified by drawing three sinus-to-commissure lines. The intersection of these three lines identifies the “center” of the cloverleaf. (2) The largest radius from this center point to any of the sinuses is identified as the “radius” of the aortic root. (3) This radius is doubled to give the “diameter” of the aortic root. We find that this diameter best corresponds to maximal wall stress in the aortic root. Please note that this diameter defines the smallest circle that completely encloses the cloverleaf shape, touching the depths of all three sinuses.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
The ultimate fate of a compromised thoracic aorta—dilatation, dissection, and rupture—depends on the imposed hemodynamic loads and mechanical properties of the wall, that is, on the mechanics. Of particular importance is a measure of the intensity of the force within the aortic wall, often calculated as a mechanical stress. Assessing and understanding values of wall stress are important clinically and scientifically for two key reasons: the process of aneurysmal dilatation depends in part on mechanobiological responses of vascular cells to changes in wall stress, and dissection and rupture occur when wall stress exceeds wall strength [1, 2]. Advances in medical imaging and computational methods now enable detailed calculations of wall stress in the aorta [3,4,5], but these calculations require knowledge of patient-specific mechanical properties, which evolve as the disease progresses and vary from region-to-region even under normal conditions. Despite continued advances, it remains difficult to estimate the requisite (nonlinear, anisotropic) mechanical properties of the aorta.
For this reason, many rely on the classical law of Laplace, found prominently in engineering and medical textbooks alike. Although the simplicity of this relation, that wall stress is determined by blood pressure, inner diameter, and wall thickness, renders it attractive for use, this relation strictly holds only for an idealized cylindrical geometry. Another seldom appreciated advantage of this relation is its universality: it holds independently of the underlying mechanical properties of the material since it is derived from a force balance (equilibrium) alone. For this reason the law of Laplace always provides the correct mean (radially averaged) value of wall stress in the circumferential direction of a pressurized cylindrical tube [6]. Yet, the complex, non-cylindrical cross-sectional geometry of the aortic root necessitated a search for an extended law of Laplace.
Currently, measurements of aortic diameter critically influence decisions on surgical aortic intervention. There is, however, a “dirty little secret” in radiographic imaging and measurement of the aorta: it is unclear how best to measure this most anatomically complex site within the aorta, the aortic root [7]. Measuring the simple diameter of the aorta at different positions—ascending, arch, descending, and abdominal—is reasonable only because the lumen is circular in cross-section. By contrast, the aortic root has a 3-lobed cloverleaf cross-sectional shape. There is no definition for the diameter of such a structure, hence rendering the classical law of Laplace inappropriate for use at the aortic root.
Absent societal guidelines, different imaging centers measure the aortic root differently (Fig. 1A). Many centers measure a “diameter” from the depth of a sinus to the opposing commissure; other centers measure a “diameter” from the depth of one sinus to the depth of the opposing sinus. Furthermore, for each of these methods, there are three potential measurements, one for each sinus. If all three sinuses are indeed measured, most centers would likely choose the largest of the three measurements for the representative diameter. Clearly, then, there can be substantial differences between measurements, with the sinus-to-sinus technique yielding larger measured dimensions. Without consistent techniques, accuracy of follow-up and precision of clinical care will suffer. Furthermore, without consistent techniques, research studies—especially those linking aortic size to adverse clinical outcomes—will also suffer.
One may wonder how echocardiography (ECHO) of the aortic root fits into this paradigm. As rightly taught by experts, the echocardiographer must ensure that both sinuses are full in the images selected for measurement. The plane of the image must be well selected to achieve this goal (Fig. 1B). Anatomically, this corresponds most closely to a sinus-to-sinus image on CT or MRI. Not achieving an ECHO image with full sinuses will underestimate the true sinus-to-sinus dimension [8].
With these many considerations in mind, we sought to explore from a bioengineering standpoint the question of what method of measurement of aortic root diameter is more closely related to wall stress and thus preferred for clinical assessment. This paper presents the product of these efforts. It includes (i) a mathematical extension and validation of the law of Laplace from a circular to a cloverleaf cross-sectional shape, and (ii) careful assessment of patient imaging studies to determine which method of aortic root measurement best represents wall stress by the extended Laplace formula. In this way, we identified a scientifically motivated definition for the diameter of the clover-leaf shaped cross-section of the aortic root.
Methods
This study was approved by the Human Investigations Committee of Yale University.
An extended Laplace relation for the clover leaf-shaped sinuses of Valsalva
We used a standard balance of forces (equilibrium) and the symmetrical properties of a prototypical aortic root to derive mathematically an extended law of Laplace for a cloverleaf shaped cross-section at the sinuses of Valsalva. Interpretation of this mathematical derivation is limited to the two-dimensional oblique plane of the root.
If we define the center of cloverleaf shaped cross-section as the point where the planes of symmetry, or the three depth-to-commissure lines, coincide (at Point O in Fig. 2), then the radially-averaged wall stress can be calculated as (see Supplementary Information for a description of the mathematical derivation)
which holds for any cross-sectional shape with two or more planes of reflective symmetry. Equation (1) thus reveals that maximum wall tension occurs at the depth of a sinus independent of the specific material properties. By considering the similarity of Eq. (1) to Laplace’s law for a circular section, the equivalent diameter in a cloverleaf shaped cross-section is defined as twice the distance from sinus depth to cloverleaf center, which equals the diameter of a circle that circumscribes the cloverleaf. Note that these dimensions emerged naturally from the mathematical derivation; they were not selected based on prior experience or hypothesis.
The validity of this extended law of Laplace, derived from first principles, was assessed by comparison to results from finite element analyses using two different computational programs (commercially available and open source), two different material models (linear and nonlinear), and different cross-sectional geometries and distending pressures (see Supplementary Information). It can also be seen that this relationship reduces to the classical law of Laplace for circular cross-sections, with 2 × distance to the center equal to the circle’s diameter, which provides additional validation.
Patients
We next considered clinical data with patients (n = 106) divided into four groups: those with non-dilated aortic roots (controls), non-syndromic root dilation, Marfan syndrome (MFS), and bicuspid aortic valve (BAV). We sampled male and female patients by a 1 to 1 ratio, where possible. We used a root index [11], defined as mean depth to commissure measurement/patient height2.7, to delineate patients in the non-dilated group from those in the non-syndromic dilated group, where patient height was in meters. A cut-off value of 8.5 mm/m2.7 was used to categorize roots as non-dilated versus dilated. Patient characteristics are listed in Table 1.
Statistical tests
Statistical tests were performed using GraphPad Prism (version 9, GraphPad Software Inc, San Diego, California). The Anderson–Darling test was performed to assess data normality. T-test and Mann–Whitney test were performed to compare two groups of measurements. One-way ANOVA test with Geisser-Greenhouse correction followed by Dunnett multiple comparisons test as well as Friedman tests with Dunn’s multiple comparisons test were performed to compare multiple groups. Differences with p-values < 0.05 were considered significant.
Area measurements
The area of the cloverleaves was measured in the oblique plane using ImageJ (National Institutes of Health, Bethesda, Maryland; Ref. 12). An arbitrary measurement was marked on Visage (Visage Imaging, San Diego, California) that was then used for setting the image scale in ImageJ. The periphery of the cloverleaf shaped cross-section was subsequently marked by a polygonal selection, whose area was computed by ImageJ.
Results
Validation of the mathematical derivation by finite element computations
The extended Laplace relation was derived mathematically using a force balance and a fluid–solid free body diagram. This derivation was validated by comparing results with those obtained using finite element computational methods. The wall tension values, perpendicular to radii tracing outward from the center, computed by the finite element model equaled those from the extended Laplace relation (Eq. 1) with high precision in all tested cases (to within 0.01 of a percent), including that for an idealized epitrochoid shape of the aortic root (Fig. 3B). The agreement between the two methods, around the perimeter of the cross-section, was independent of the applied pressures over the range 80 to 150 mmHg. Moreover, the independence of the calculated wall stress from a material model and associated parameters in the finite element computations confirmed the universality of the extended Laplace relation (Eq. 1).
Comparison of different measurements in the four patient groups
We quantified the dimensions of aortic roots at the sinuses of Valsalva using previously employed metrics and the new proposed metric, the Laplace diameter (Fig. 4E). Measurements and associated comparisons across all patients are shown for each of the four groups (Fig. 5). Although the aortic roots were different in size across the four groups, the Laplace diameter was significantly different than each of the other metrics within each group (p-value < 0.05). The Marfan group exhibited the largest measured Laplace diameters within this cohort, followed by the non-syndromic dilated and then bicuspid aortic valve groups.
Correlation of Laplace diameter with the area of the cloverleaf and patient height
We next assessed possible correlations between the Laplace diameter and two readily measured patient-specific metrics: the area of the cloverleaf shaped cross-section at the root and patient height. Cloverleaf area was found to scale with Laplace diameter via a power-law with an exponent between 1 and 2 (Fig. 6). An exponent equal to 1 would indicate a linear correlation, whereas 2 would correspond to a uniform expansion of the cloverleaf with no change in shape. Observation of an exponent smaller than 2 agrees with the clinically observed change in shape of the cloverleaf shaped cross-section in more dilated roots. The linear correlations between the Laplace diameter and patient height were stronger in the non-dilated group (R2 = 0.62) than in the non-syndromic dilated, Marfan, and bicuspid groups (R2 = 0.37, 0.21, and 0.23, respectively).
Effect of asymmetry of the sinuses in the bicuspid patients
The derivation of the extended Laplace relation relies on the existence of two or more planes of symmetry within the cloverleaf shaped cross-section of the aortic root. These shapes were not all symmetric, however. For example, the symmetry condition was absent in roots where the cusps were not of the same size. Especially in the case of the bicuspid aortic valves, we visually observed a relatively larger number of asymmetrically dilated roots (Fig. 7). We thus quantified the asymmetric dilatation of the roots via a two-step approach. First, we found the mean value of the three sinus-to-commissure dimensions in a single root; second, we found the relative deviation of each measurement from the mean. The calculated relative deviations were significantly higher in the bicuspid group compared with baseline, the non-dilated group (p-value < 0.05), as seen in Fig. 7E. We point out that the assessed roots were only mildly asymmetric, and in these cases we expect the extended law of Laplace to reasonably estimate wall stress. Moreover, in case of an asymmetrically dilated root, a conservative estimate may be made using twice the distance between the center of the cloverleaf and the depth of the most dilated sinus as the diameter.
Effect of the less protruded shape of the root in the Marfan syndrome patients
The derivation of the extended law of Laplace suggested that the most dramatic differences between the Laplace diameter and sinus-to-commissure measurements should emerge in aortic roots with more protruded sinuses. Various degrees of protrusion presented in the set of assessed roots. For instance, in the Marfan group, roots frequently exhibited more round / circle-like shapes, with less protruded sinuses, compared with the non-dilated group, which included more protruded sinuses (Fig. 8). We quantified the differences in the protrusion of sinuses in these two groups by calculating acircularity of the cloverleaf shaped cross-sections at the root. Acircularity was measured by the relative difference in the diameters of the circles enclosed by and enclosing the cloverleaf shape (Fig. 8E, inset). A significant difference was observed in the relative acircularity of the non-dilated versus the Marfan roots (p-value < 0.05). That is to say, with the more severe deformity of the root in Marfan patients, the normal distinct sinus configuration (with normal, substantial protrusion of the sinuses) gave way to a more circular root shape.
Real world clinical application
In order to assess clinical applicability and intra- and inter-observer reliability, we applied the Laplace measurement technique to the most recent 24 consecutive, unselected patients seen in consultation (office of JAE) who had high quality CT scans available for analysis (official radiology reports with aortic root measurements were available for 18 of the 24 patients).
Comparative diameters by various techniques
In this group of patients, aortic root diameter by the Laplace technique ranged from 30.4 mm to 59.5 mm, with a mean of 41.6 mm. These Laplace diameters were larger than the root diameters measured in the standard radiology reports (range 27 mm to 47 mm, mean 37.3 mm). The conventional coronal aortic root measurements were larger than root diameters provided in radiology reports in 17 of the 18 patents (mean difference of 2.5 mm, range 0 to 4.1 mm). The Laplace diameters (above) were larger even than the coronal root diameters measured conventionally by our team (range 26.3 mm to 50.0 mm, mean 38.3 mm). Diameter of the aortic root in coronal views was measured by scrolling anteriorly and posteriorly and selecting the image with the largest diameter. Hence: Standard measurements < Coronal measurements < Laplace measurements.
Intra-observer variability
Two observers (JAE and BAZ) independently measured the aortic roots by the Laplace technique on two separate occasions, one week apart. The absolute aortic root diameter differences between the two measurement sessions ranged from 0.2 mm to 2.4 mm, mean 0.9 mm for one observer (JAE) and between 0 and 2.2 mm, mean 0.6 for the other observer. The intra-observer variability, analyzed by the Intra-class Correlation Coefficient (ICC) [13] was 0.96 (JAE) and 0.97 (BAZ).
Inter-observer variability
A second experienced reader (BAZ) read the Laplace diameters independently (of JAE). The absolute aortic root radius differences between the average of two measurements obtained by the two observers ranged from 0.2 to 2.9 mm (mean 1.6) (Table 2). The inter-observer variability ICC index was 0.89. Values of the Intra-class Correlation Coefficient (used in this analysis for inter- and intra-observer variability calculations) between 0.75 and 0.9 show good reliability, and any value above 0.9 indicates excellent reliability [13].
Discussion
Thoracic aortic aneurysm and dissection (TAAD) is responsible for significant morbidity and mortality, with conservative estimates ranging up to 15,000 deaths/year in the USA alone [14]. Advances in genetics and medical screening continue to increase the number of TAADs diagnosed each year, which suggests that many prior dissection or rupture related deaths may have been falsely ascribed to other causes, including heart attack. In fact, among patients suffering out-of-hospital cardiac arrest undergoing peri-mortem diagnostic CT scan, a staggering 8.07% had succumbed to undiagnosed aortic dissection [15]. Even more troublesome is that thoracic aortic dissections are the cause of death in over 5% of all young people suffering sudden cardiac death [16]; that is, these lethal conditions affect young and old alike. There is clearly a pressing need for increased understanding.
Notwithstanding concerns with aortic diameter as a reliable metric of risk for acute aortic syndromes [17,18,19], this easily measured quantity yet continues to play a critical role in clinical decisions [20]. Because the aorta dissects or ruptures only when the mechanical stress exceeds the strength of the wall, many authorities also continue to suggest a similar need to calculate and compare values of wall stress [21,22,23]. For reasons noted above, however, there has been considerable variation in the measurement of aortic root diameter and no truly reliable method to estimate wall stress. We believe that in the future, with the advancement of methods for determining material stiffness and strength properties, having finite element computations in the decision loop will potentially provide a promising aid to clinical patient evaluation. However, in the absence of material parameters and image-based finite element computations in everyday practice, the presented enhanced Laplace method addresses a pressing need for mechanistic tools that inform decisions related to the Sinuses of Valsalva.
Herein, we suggest an extended law of Laplace that provides a simple, universal estimate of wall stress in the aortic root that overcomes challenges with both the inappropriate use of the classical law of Laplace and insufficient information on patient-specific material properties needed for image-based finite element calculations. Moreover, this simple derivation revealed a reliable, easily measured, metric—the Laplace diameter—that promises to help delineate risk across different classes of aneurysms based on medical images of the aortic root. The intra-observer and inter-observer variabilities for our Laplace technique of aortic root measurement fall well within the ranges usually found for traditional measurements of aortic diameter, where “Variations in AAA measurement of 0.5 cm or more are not uncommon…” [24,25,26].
As illustrative results, we found that this Laplace diameter was significantly larger than three other commonly used measures of aortic root dimensions, suggesting further that the prior measurements of diameter led to underestimating wall stress. Importantly, the Laplace diameter did not correlate strongly with patient height in the three aneurysmal groups considered–non-syndromic, bicuspid, and Marfan. Rather, the Laplace diameter correlated well with the cross-sectional area at the aortic root, consistent with it being primarily a measure of size (R2 = 0.96, non-dilated group). As expected, the other measurements are also related to the size of the root and correlate rather well with cross-sectional area (R2 = 0.95 for depth-to-depth and depth-to-commissure measurements, and R2 = 0.93 for coronal measurements within the non-dilated group). With practice, determining the Laplace diameter becomes a simple method to quantify aortic size, providing an appropriate indicator of severity of wall stress (see accompanying video, demonstrating application of the Laplace measurement technique). These Laplace metrics, however, depend on the existence of certain symmetries within the aortic root. Of the cases considered, the aortic root in patients with bicuspid aortic valve exhibited a lack of root symmetry, thus necessitating careful evaluation of root shape, not just size, and warranting caution in the use of these metrics in these cases. In cases of symmetry, however, the extended law of Laplace and the Laplace diameter upon which it is based provides quick, straightforward assessments. It is suggested that these metrics can be added to others to increase risk stratification in regression-based predictive models [27]. Finally, we hope that the proposed method would complement previous efforts in measurements of the aortic root structure [28, 29] and contribute to more uniform analysis of the root dimensions.
Conclusion
In this study, we addressed head-on issues with discrepant methods of measurement of the aortic root—issues originating from its non-circular, cloverleaf shaped cross-section. Using fundamental mathematical calculations, we extended the classical law of Laplace specific for the cloverleaf shaped cross-section at the aortic root. This work exploits basic force balances and particular symmetries in geometry; it was thus not an experimentally determined modification of the law of Laplace, but rather a purely mathematical derivation. Like the classical law of Laplace, this extended law is universal, thus determining radially-averaged circumferential wall stress in aortic roots having two or more planes of symmetry, independent of specific material properties. We then confirmed the validity of the mathematical derivation using computational finite element analyses with an idealized root geometry defined by an epitrochoid and other symmetric geometries such as ellipses, triangles, and diamonds and various values of material parameters for both linear and nonlinear material descriptions. The wall stresses calculated from the finite element computations and the extended law of Laplace (Eq. 1) agreed with high precision. In the cloverleaf cross-sectional geometry of the Sinuses of Valsalva, the extended law of Laplace introduces the diameter of the circumscribed circle as the primary dimension related to wall stress. The Laplace diameter was larger than the sinus-to-commissure, the mid-sinus-to-mid-sinus, and the diameter in the coronal plane, suggesting that the other measurements would underestimate the wall stress. Regardless, this Laplace diameter offers a new, theoretically motivated approach to measure and compare aortic root dimensions uniformly across centers.
Perspectives/clinical competencies
This manuscript analyzes in detail multiple factors involved in achieving well motivated and consistent measurements of the aortic root. The root portion of the aorta is anatomically complex and is quantification has been problematic in terms of intra- and inter-institutional methodology, subject to high variability and little uniformity. The geometric analyses herein should be of use to clinicians of all levels of experience. The derivation of an extended law of Laplace in this manuscript applies basic geometric and mechanical principles and more accurately represents maximal wall stress. This extension of Laplace has implications in terms of optimal methods of measuring the “diameter” of a cloverleaf shaped cross-section. We hope that this analysis and these recommendations may encourage standardization of measurements of the aortic root in a geometrically justified fashion.
References
Elefteriades JA (2008) Thoracic aortic aneurysm: reading the enemy’s playbook. Curr Probl Cardiol 33(5):203–277. https://doi.org/10.1016/j.cpcardiol.2008.01.004
Humphrey JD, Milewicz DM, Tellides G, Schwartz MA (2014) Dysfunctional mechanosensing in aneurysms. Science. https://doi.org/10.1126/science.1253026
Vorp DA, Schiro BJ, Ehrlich MP, Juvonen TS, Ergin MA, Griffith BP (2003) Effect of aneurysm on the tensile strength and biomechanical behavior of the ascending thoracic aorta. Ann Thorac Surg 75(4):1210–1214. https://doi.org/10.1016/S0003-4975(02)04711-2
Pasta S, Rinaudo A, Luca A et al (2013) Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve. J Biomech 46(10):1729–1738. https://doi.org/10.1016/j.jbiomech.2013.03.029
Wang Z, Flores N, Lum M et al (2021) Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm. J Thorac Cardiovasc Surg 162(5):1452–1459. https://doi.org/10.1016/j.jtcvs.2020.02.046
Humphrey JD, O’Rourke SL (2015) Equilibrium, universal solutions, and inflation. An introduction to biomechanics: solids and fluids, analysis and design. Springer, New York, pp 109–62
Elefteriades JA, Mukherjee SK, Mojibian H (2020) Discrepancies in measurement of the thoracic aorta: JACC review topic of the week. J Am Coll Cardiol 76(2):201–217. https://doi.org/10.1016/j.jacc.2020.03.084
Upadhyaya K, Ugonabo I, Satam K, Hull SC (2021) Echocardiographic evaluation of the thoracic aorta: tips and pitfalls. Aorta (Stamford) 09(1):1–8. https://doi.org/10.1055/s-0041-1724005
Alnæs M, Blechta J, Hake J et al (2015) The FEniCS project version 15 archive of numerical software. https://doi.org/10.11588/ans.2015.100.20553
Hibbett K (1998) Sorensen. ABAQUS/standard: user’s manual. vol. 1. Hibbitt, Karlsson & Sorensen
Pham MHC, Ballegaard C, de Knegt MC et al (2019) Normal values of aortic dimensions assessed by multidetector computed tomography in the Copenhagen General Population Study. Eur Heart J Cardiovasc Imaging 20(8):939–48. https://doi.org/10.1093/ehjci/jez012
Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9(7):671–675. https://doi.org/10.1038/nmeth.2089
Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15(2):155–163. https://doi.org/10.1016/j.jcm.2016.02.012
Milewicz DM, Guo D-C, Tran-Fadulu V et al (2008) Genetic basis of thoracic aortic aneurysms and dissections: focus on smooth muscle cell contractile dysfunction. Annu Rev Genomics Hum Genet 9(1):283–302. https://doi.org/10.1146/annurev.genom.8.080706.092303
Moriwaki Y, Tahara Y, Kosuge T, Suzuki N (2013) Etiology of out-of-hospital cardiac arrest diagnosed via detailed examinations including perimortem computed tomography. J Emerg Trauma Shock 6(2):87–94. https://doi.org/10.4103/0974-2700.110752
Jain D, Dietz HC, Oswald GL, Maleszewski JJ, Halushka MK (2011) Causes and histopathology of ascending aortic disease in children and young adults. Cardiovasc Pathol 20(1):15–25. https://doi.org/10.1016/j.carpath.2009.09.008
Chau KH, Elefteriades JA (2013) Natural history of thoracic aortic aneurysms: size matters, plus moving beyond size. Prog Cardiovasc Dis 56(1):74–80. https://doi.org/10.1016/j.pcad.2013.05.007
Adriaans BP, Wildberger JE, Westenberg JJM, Lamb HJ, Schalla S (2019) Predictive imaging for thoracic aortic dissection and rupture: moving beyond diameters. Eur Radiol 29(12):6396–7404. https://doi.org/10.1007/s00330-019-06320-7
Pape LA, Tsai TT, Isselbacher EM et al (2007) Aortic diameter ≥5.5 cm is not a good predictor of type A aortic dissection. Circulation 116(10):1120–7. https://doi.org/10.1161/CIRCULATIONAHA.107.702720.
Davies RR, Gallo A, Coady MA et al (2006) Novel measurement of relative aortic size predicts rupture of thoracic aortic aneurysms. Ann Thorac Surg 81(1):169–177. https://doi.org/10.1016/j.athoracsur.2005.06.026
Nathan DP, Xu C, Plappert T et al (2011) Increased ascending aortic wall stress in patients with bicuspid aortic valves. Ann Thorac Surg 92(4):1384–1389. https://doi.org/10.1016/j.athoracsur.2011.04.118
Gomez A, Wang Z, Xuan Y et al (2021) Regional wall stress differences on tricuspid aortic valve-associated ascending aortic aneurysms. Interact CardioVasc Thorac Surg. https://doi.org/10.1093/icvts/ivab269
Vignali E, Gasparotti E, Celi S, Avril S (2021) Fully-coupled FSI computational analyses in the ascending thoracic aorta using patient-specific conditions and anisotropic material properties. Front Physiol 12:732561. https://doi.org/10.3389/fphys.2021.732561
Lederle FA, Wilson SE, Johnson GR et al (1995) Variability in measurement of abdominal aortic aneurysms. J Vasc Surg 21(6):945–952. https://doi.org/10.1016/S0741-5214(95)70222-9
Rudarakanchana N, Bicknell CD, Cheshire NJ et al (2014) Variation in maximum diameter measurements of descending thoracic aortic aneurysms using unformatted planes versus images corrected to aortic centerline. Eur J Vasc Endovasc Surg 47(1):19–26. https://doi.org/10.1016/j.ejvs.2013.09.026
Rueckel J, Reidler P, Fink N et al (2021) Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up. Eur J Radiol. https://doi.org/10.1016/j.ejrad.2020.109424
Mori M, Gan G, Deng Y et al (2021) Development and validation of a predictive model to identify patients with an ascending thoracic aortic aneurysm. J Am Heart Assoc 10(22):e022102. https://doi.org/10.1161/JAHA.121.022102
Tretter JT, Mori S (2019) Two-dimensional imaging of a complex three-dimensional structure: measurements of aortic root dimensions. J Am Soc Echocardiogr 32(6):792–794
Mori S, Anderson RH, Tahara N, Izawa Y, Toba T, Fujiwara S et al (2017). The differences between bisecting and off‐center cuts of the aortic root: the three‐dimensional anatomy of the aortic root reconstructed from the living heart. Echocardiogr 34(3):453–461
Funding
There was no specific funding for this study.
Author information
Authors and Affiliations
Contributions
This study was approved by the Yale University Human Investigation Committee. All authors contributed substantially to this work. The concept was originated by JAE and JDH. The mathematical/engineering concepts were fashioned by EB, RK, ABR, and PDK. MAZ, HE, and BAZ analyzed clinical data. The Laplace CT scan reads were done by BAZ and JAE. The first draft was written by EB (engineering) and JAE (clinical) and reviewed, edited, and revised by all authors.
Corresponding author
Ethics declarations
Competing interests
Disclosures: Drs. Ban, Kalogerakos, Khosravi, Ziganshin, Ellauzi, Ramachandra, and Zafar have no disclosures. J.D. Humphrey: Member of the Scientific Advisory Board who also receives consulting fees from HeartFlow, Inc., a company using computational modeling to assess coronary artery disease. J.A. Elefteriades: Principal, CoolSpine. CoolSpine has no clinical products.
Conflict of interest
Drs. Ban, Kalogerakos, Khosravi, Ziganshin, Ellauzi, Ramachandra, and Zafar have no disclosures. J.D. Humphrey: Member of the Scientific Advisory Board who also receives consulting fees from HeartFlow, Inc., a company using computational modeling to assess coronary artery disease. J.A. Elefteriades: Principal, CoolSpine. CoolSpine has no clinical products.
Ethical approval
This study was approved by the Yale University Human Investigation Committee.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Supplementary Video S1. Application of the new Laplace diameter measurement technique to patient CT scans. (MP4 101211 KB)
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ban, E., Kalogerakos, PD., Khosravi, R. et al. Extended law of laplace for measurement of the cloverleaf anatomy of the aortic root. Int J Cardiovasc Imaging 39, 1345–1356 (2023). https://doi.org/10.1007/s10554-023-02847-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-023-02847-5