Abstract
Purpose
Self-expandable stents have enabled endovascular treatment of wide-necked aneurysms (ordinarily viewed as technically prohibitive), with favorable outcomes. However, the impact of stent type on occlusive stability has not been adequately investigated. In small-sized unruptured saccular aneurysms, we generated estimates of stent-assisted coil embolization outcomes during follow-up monitoring. Stent type and other risk factors linked to recanalization were analyzed.
Methods
A cohort of 286 patients harboring 312 small-sized unruptured aneurysms (< 10 mm) was subjected to mid-term and extended follow-up monitoring after stent-assisted coiling. Three types of stents (Enterprise, 192; Neuroform, 27; LVIS, 93) were deployed in this population; all medical records and radiologic data of which were reviewed. Mid-term recanalization rates and related risk factors were assessed using binary logistic regression analysis.
Results
A total of 49 aneurysms (15.7%) displayed recanalization at 6 months postembolization, with 34 and 15 instances of minor and major recanalization, respectively. Multivariate analysis indicated that wide-necked aneurysms (> 4 mm) (HR = 2.362; p = 0.017), incomplete occlusion at time of coiling (HR = 2.949; p = 0.002), and stent type (p = 0.048) were significant factors in mid-term recanalization, whereas hypertension (p = 0.095) and packing density ≤ 30% (p = 0.213) fell short of statistical significance. Compared with Enterprise (HR = 2.828) or Neuroform (HR = 4.206) stents, outcomes proved more favorable with use of LVIS.
Conclusions
Above findings demonstrate that in addition to occlusive status at time of coil embolization and neck size, stent type may affect follow-up outcomes of stent-assisted coil embolization in small-sized aneurysms. LVIS (vs Enterprise or Neuroform stents) performed best during follow-up monitoring in terms of limiting recanalization.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Since the landmark International Subarachnoid Aneurysm Trial (ISAT), endovascular coil embolization has assumed wide usage for treatment of intracranial aneurysms [1]. Although wide-necked aneurysms still pose a technical challenge for endovascular treatment [2], device improvements and advanced coiling techniques have made it possible to treat a large percentage of oddly configured aneurysms that ordinarily hamper endovascular coil embolization [3]. Stenting systems in particular have continued to evolve, broadening the scope of endovascular therapy considerably in this setting [2, 4]. Deployed stents provide mechanical support to prevent coil prolapse, enable dense packing of coil, and potentially divert blood flow around aneurysms, serving as a scaffold for endothelial growth and vessel healing [5,6,7,8]. Once the Neuroform stent (Stryker, Kalamazoo, MI, USA) debuted for treatment of aneurysms, others soon followed, each intended for specific aneurysmal configurations and parent arterial patterns [9]. The properties of each device stem from configurations or manufacturing methods (e.g., open or close-cell type, laser cut, or braided type), imparting behavioral differences relative to neck protection and flow diversion. Although stents used accordingly are believed protective, preventing progression to recanalization during follow-up periods, the impact of stent type on postcoiling occlusive status of aneurysms has not been adequately investigated. Given that recanalization generally develops within 6 months of coiling [10, 11], mid-term (6-month) and more extended monitoring of aneurysms was conducted after stent-assisted coil embolization to assess recanalization rates and factors impacting recanalization, including stent type.
Materials and methods
Patient selection and data collection
A total of 1652 consecutive coil embolization procedures done at a single institution between September 2012 and June 2016 were accessed for this retrospective review. Of these, 463 entailed stent-assisted coiling. Non-saccular (n = 43), recanalized (n = 65), large-sized (≥ 10 mm; n = 26), ruptured (n = 3) aneurysms were excluded, leaving 326 saccular aneurysms eligible for study. Endpoints of this study were recanalization of coiled aneurysms in follow-up imaging at 6 months and beyond. Thus, lesions lacking 6-month follow-up monitoring (n = 14) were further excluded. Ultimately, 286 patients with 312 aneurysms were investigated (Fig. 1). During this period, three types of stents (Enterprise [Codman Neuro, Raynham, MA, USA], Neuroform [Stryker], and LVIS [MicroVention Inc., Tustin, CA, USA]) were utilized at our institution. Multiple patient variables were retrieved from medical records as follows: gender, age, and medical parameters (hypertension, diabetes, smoking, hyperlipidemia). Angiographic data were also collected, namely overall dimension and neck size, location (anterior vs posterior circulation) [12], and type (side-wall vs bifurcation) of aneurysm [13]; depth-to-neck ratio (D/N ratio); packing density; and use of bioactive coils (hydrogel-modified or polyglycolic acid/lactide copolymer-coated coils). Based on length of bioactive coil engaged (relative to total length of coil inserted), aneurysms were grouped as bare (≤ 50%) or bioactive (> 50%) coil. After the procedure, coil packing density was calculated as the ratio of the total coil volume to aneurysmal volume. The aneurysmal volume was measured based on the assumption that the aneurysm was ellipsoid. In addition, the volume of the coils deployed into the aneurysm was calculated by multiplying the length of the coil by the cross sectional area. This study was conducted with approval of our Institutional Review Board. The requirement to obtain written informed consent for study participation was waived.
Endovascular procedure and angiographic monitoring
Most endovascular procedures were conducted under general anesthesia. All patients with UIAs were given antiplatelet medication beforehand. As stipulated at our institution, dual antiplatelet agents (clopidogrel and aspirin) were administered if stent protection was anticipated [14]. In patients responding poorly to clopidogrel, based on the VerifyNow P2Y12 assay (Accriva Diagnostics, Edison, NJ, USA), cilostazol was added. A bolus of heparin (3000 IU) was administered after femoral arterial sheath placement, supplemented by hourly boluses (1000 IU), and activated clotting time was monitored hourly. Upon completing endovascular procedures, tirofiban or heparin infusion was maintained for up to 12 h in instances of procedural thromboembolism. Sustained antiplatelet medication was recommended after procedures, using dual agents for at least 3 months and a single agent for at least 1 year.
Follow-up radiologic examinations, performed at 6, 12, 24, and 36 months post-procedure, relied on time-of-flight magnetic resonance angiography (TOF-MRA). Three tesla (T) (n = 182) and 1.5 T (n = 130) MR scanners were used for the acquisition of 3D reconstruction and source images. If MRA was not feasible or if recanalization was suspected by MRA, conventional angiography was advised to determine the need for further treatment. Anatomic outcomes of complete occlusion or recanalization were gauged according to the Raymond-Roy occlusion classification (RROC) [10]. Recanalization was defined as RROC class II (minor) and RROC class III (major), regardless of immediate postembolization angiographic results. Follow-up diagnostics were randomly scheduled, with two experienced neurointerventionists (YDC, HSK) blinded to pertinent clinical and radiologic information independently reviewing all follow-up tests, including MRA (MIP images and source images) and conventional angiography. In event of disagreement, a consensus was established by a third interventional neuroradiologist (MHH).
Statistical analyses
Continuous data were expressed as mean ± standard deviation (SD). Chi-square and Fisher’s exact tests or unpaired t test were used to assess categorical or continuous variables, respectively. Univariate analysis of parameters impacting recanalization after coiling was conducted via binary logistic regression, using variables with p values < 0.10 in a multivariable model to determine risk factors. Average annual risk of recanalization was calculated as total of recanalized aneurysms divided by aneurysm-year total for the follow-up periods. Recanalization-free survival was estimated using the Kaplan-Meier method, and the survival rates were compared using the log-rank test. Statistical significance was set at p < 0.05, employing standard software (SPSS v19; SPSS Inc., Chicago, IL, USA) for all analytics.
Results
Characteristics of coiled aneurysms with stent
A total of 286 patients subjected to stent-assisted coiling of 312 small-sized unruptured aneurysms (< 10 mm) were monitored at 6 months postembolization. Subjects were predominantly female (232/312, 74.4%), with mean age of 58.7 ± 9.5 years. Most lesions involved anterior (284/312, 91.0%) rather than posterior (28/312, 9.0%) circulation. Aneurysms of anterior circulation were distributed as follows: internal carotid artery, 105; anterior communicating and anterior cerebral arteries, 72; middle cerebral artery, 77; and posterior communicating artery, 30. Side-wall and bifurcation aneurysms totaled 142 (45.5%) and 170 (54.5%), respectively. Mean estimated size of aneurysms was 5.3 ± 1.8 mm, and 150 lesions (48.1%) were ≤ 5 mm. Aneurysmal neck measured > 4 mm in 151 aneurysms (48.4%), and in 53 aneurysms (17.0%), D/N ratio was > 1.5. Mean packing density of coil was 34.1 ± 8.6%, with bioactive coil > 50% in 33 aneurysms (10.6%). Enterprise stent was applied in 192 aneurysms, Neuroform stent was in 27, and LVIS was in 93. Successful occlusion was achieved immediately after coil embolization in 181 aneurysms (58.0%). Characteristics of aneurysms studied are detailed in a Supplemental Table.
Recanalization of coiled aneurysms at 6 months
A total of 49 aneurysms (15.7%) showed recanalization (minor 34; major 15) at 6-month follow-up monitoring. In the follow-up occlusion result, interobserver agreement was found to be excellent (k = 0.818, range 0.774 to 0.862). Baseline characteristics were as follows: female, 39/49 (79.6%); mean age, 59.6 ± 10.2 years; hypertension, 30/49 (63.3%); anterior location, 45/49 (91.8%); bifurcation aneurysm, 23/49 (46.9%), mean size, 6.0 ± 1.7 mm; packing density, 30.9 ± 9.0%; bioactive coil > 50%, 5/49 (10.2%); and D/N ratio > 1.5, 6/49 (12.2%). In decreasing order, Enterprise, 35/49 (71.4%); Neuroform, 8/49 (16.3%); and LVIS, 6/49 (12.2%) stents were used (Figs. 2, 3, and 4). Univariate analysis indicated that hypertension, aneurysmal neck size, packing density, incomplete occlusion immediately postembolization, and stent type were associated with recanalization (Table 1). Other variables, such as female gender, age, aneurysmal location, diabetes, smoking, hyperlipidemia, bifurcation aneurysm, D/N ratio, aneurysmal size, and bioactive coil usage, did not impact recanalization significantly. In multivariate analysis, wide-necked aneurysms (> 4 mm) (HR = 2.362; p = 0.017), incomplete occlusion immediately postembolization (HR = 2.949; p = 0.002), and stent type (p = 0.048) were identified as significant risk factors for mid-term recanalization, whereas hypertension (p = 0.095) and packing density ≤ 30% (p = 0.213) fell short of statistical significance (Table 2). Outcomes of aneurysms bearing LVIS stents were more favorable by comparison (Enterprise, HR = 2.828; Neuroform, HR = 4.206).
Extended monitoring of coiled aneurysms completely occluded or showing minor recanalization at 6 months
Of 263 aneurysms showing complete occlusion at 6 months, 173 were further evaluated (≥ 12 months). The other 90 lesions were either recently treated (< 12 months prior; n = 53) or had been followed for 6 months only (n = 37). Eight aneurysms (Enterprise, 5; LVIS, 3) developed recanalization (minor, 6; major, 2) during 381.5 aneurysm-years of monitoring (mean follow-up period, 26.1 ± 10.1 months; median, 18 months). Overall recanalization rate of coiled aneurysms completely occluded at 6 months was 2.1% per aneurysm-year. Of 34 aneurysms showing minor recanalization at 6 months, 27 aneurysms were monitored further (mean follow-up period, 27.6 ± 0.4 months; median, 30 months). Three aneurysms (all Enterprise stents) progressed to major recanalization during 62.1 aneurysm-years. The overall annual rate of major recanalization in coiled aneurysms with minor recanalization at 6 months was 4.8% per aneurysm-year. Kaplan-Meier estimates of cumulative survival without recanalization are presented in Fig. 5. Overall recanalization-free survival rate at 24 months was 83.2% (Neuroform, 70.4%; Enterprise, 80.0%; LVIS, 92.5%; p = 0.043).
Discussion
The use of self-expandable stents has contributed to advancement of endovascular techniques used for intracranial aneurysms [4, 15,16,17]. It became possible to treat difficult aneurysms, particularly those with complex morphologies, wide necks, or lower dome-to-neck ratios, by preventing protrusion or migration of coils and enabling dense coil packing [17, 18]. Outcomes of coil embolization also have proved more favorable with (vs without) stent assistance [4, 17, 19,20,21]. As reported by Cho et al. [17], recanalization rates in coiled aneurysms with (vs without) stents deployed were significantly lower at 6 months after coil embolization (1.9 vs 10.2%, respectively) or at last follow-up (8.3 vs 18.5%, respectively). In one meta-analysis [18], recurrence was more than halved by stent-assisted coil embolization (12%), compared with coiling-only (27.9%). These data suggest that stents divert saccular flow, inducing stasis and progressive thrombosis [6, 19, 22, 23]. They may well provide scaffolding for endothelialization of aneurysmal necks, severing them from parent arteries [15, 24]. On this basis, we analyzed various factors (including stent type) with a potential to influence mid-term anatomic outcomes of small aneurysms subjected to stent-assisted coiling.
Incomplete initial occlusion, large lesion size, low packing density, and rupture have been previously identified as factors in recanalization [4, 10, 19, 25,26,27]. Raymond et al. [10] found significantly lower risk of recurrence in instances of complete initial occlusion, whereas wide-necked aneurysms showed significantly greater risk of recurrence in long-term angiographic monitoring. In multivariate analysis of stent-assisted coiling, Chalouhi et al. [28] further demonstrated that incomplete aneurysmal occlusion at time of treatment is predictive of recanalization. In our series, multivariate analysis indicated that wide-necked aneurysms (> 4 mm), incomplete initial occlusion (at coil embolization), and stent type were significant factors in mid-term recanalization. Hence, stent type does have bearing on outcomes of stent-assisted coil embolization in follow-up monitoring of small-sized unruptured aneurysms.
A variety of self-expanding neurovascular stents (Neuroform, Leo, Enterprise, Solitaire, and LVIS) is currently available for stent-assisted coil embolization. At our facility, Enterprise, Neuroform, and LVIS devices are used preferentially for endovascular treatments. The Neuroform stent (Stryker) was the first self-expandable laser-cut stent designed to treat cerebral aneurysms. Its reputed limitations include low radial force, difficulty of deployment, saccular cell dislocation, and lack of retractability [15, 29,30,31,32]. The Enterprise device (Codman Neuro [DePuy Synthes]) was the second laser-cut, closed-cell stent to be marketed, and the Low-profile Visualized Intraluminal Support device (LVIS; MicroVention [Terumo]) is a novel, self-expandable braided stent with closed-cell design. Its helical strands (for whole dimension visualization) aid in full deployment and appropriate wall apposition.
There are notable differences in these three stents. By design, they are either open-cell (Neuroform) or closed-cell (Enterprise, LVIS) type. It is conceded that open-cell stents are superior to closed-cell counterparts in terms of wall apposition, although saccular protrusion and low radial force may be problematic [30, 32]. Both LVIS and Enterprise stents are capable of being partially deployed, recaptured, and redeployed. However, an important advantage of the LVIS stent is its metal coverage of aneurysmal neck, which is significantly greater than the others afford. In clinical practice, it is difficult to appreciate exactly how these differences might affect outcomes of endovascular treatment.
Many studies have reported angiographic follow-up monitoring of occluded aneurysms by stent type. In terms of occlusion rates, LVIS stents [9, 33,34,35,36,37] (68–92.6%) have fared better than Enterprise (42.7–74.2%) [38,39,40,41] and Neuroform (46–74.19%) stents [41,42,43,44], and earlier studies have shown slightly better outcomes in follow-up monitoring of LVIS usage. Still, there are some limitations. A mean follow-up period of only 6–7.52 months is cited in the literature on LVIS stents, compared with much longer mean durations for Enterprise (5.8–20.6 months) or Neuroform (12.0–37.1 months) stents. Extended monitoring increases detection of eventual recanalization and may explain the comparatively poorer outcomes of the latter two devices [4, 10]. Furthermore, classifying of intracranial aneurysmal occlusion (as in previous studies) is a subjective process likely to vary from one neurointerventionist to the next. Although rates of occlusion clearly seem lower in follow-up assessments of LVIS (vs Enterprise or Neuroform) stents, direct comparison by standard means is needed for validation.
Some researchers have compared stent-assisted coiling by Enterprise and Neuroform devices, analyzing outcomes in follow-up monitoring. One particular analysis, addressing 4238 aneurysms in 4039 patients, revealed higher reported rates of complete occlusion for coil embolizations using Enterprise (vs Neuroform) stents (74.7 vs 61.1%, respectively), and the recanalization rate was higher when deploying Neuroform stents [41]. Durst et al. [45] likewise reported slightly higher recanalization and retreatment rates for Neuroform (vs Enterprise) stents. In still other studies, the Neuroform (as opposed to Enterprise) stent emerged as a statistically significant independent factor in recanalization and retreatment of aneurysms [28, 45].
Our data were aligned with the above, showing a lower recanalization rate at the 6-month follow-up mark for coiling of aneurysms using an Enterprise (35/195, 17.9%) vs Neuroform (8/27, 29.6%) stent. On the other hand, there are few studies comparing the LVIS device with these other stents. We have identified only one published report of direct LVIS and Enterprise stent comparison in clinical practice. Ge et al. [46] documented progressive thrombotic occlusion during follow-up monitoring in 33% of patients subjected to LVIS stenting, compared with 14.3% of those receiving Enterprise stents. Although not statistically significant, recurrence rates for LVIS and Enterprise stent deployment did diverge (2.8 and 10.7%, respectively). In our series, the LVIS stent proved superior, showing a significantly lower recanalization rate (6/93, 6.5%; p = 0.048) by comparison. In multivariate analysis, outcomes of treated aneurysms involving LVIS stents were more favorable in follow-up monitoring than those involving Enterprise (HR = 2.828) or Neuroform (HR = 4.206) stents.
Self-expanding neurovascular stents were originally designed as scaffolding to bridge aneurysmal necks and protect against coil protrusion or migration. Subsequently, flow diversion effect and the potential for progressive postembolization thrombosis gained considerable attention. Dholakia et al. [47] discovered better flow reduction in LVIS and Enterprise stents (vs Neuroform stents) during computational simulations of fluid dynamics (82 vs 65% reduction in kinetic energy). Thus, they contended that the open-cell design of Neuroform stents may confer aneurysmal neck coverage and flow resistance to the least extent, whereas closed cell LVIS and Enterprise stents perhaps alter hemodynamic parameters, promoting saccular thrombosis and endothelialization of aneurysmal necks [28].
The LVIS stent offers a high degree of metal coverage (~ 23%), much denser than that incorporated in more conventional Enterprise and Neuroform (8–11%) stents [48]. The porosity of a neurovascular stent is also important for control of circulatory hemodynamics. Interwire spacing dictates resistance to blood flow, allowing for stasis in aneurysms and thrombotic facilitation [7, 49, 50]. Indeed, blood flow velocity and wall shear stress are proportional to metal stent coverage [51]. The superior flow reduction effect of the LVIS stent has been confirmed by Wang et al. [48], who demonstrated that a single LVIS stent surpassed even double Enterprise stenting in reducing intra-aneurysmal velocity and wall shear stress. Even double LVIS stent showed more reduction in wall shear stress and velocity compared with a single Pipeline. Excessive wall shear stress and high blood flow velocity at necks of treated aneurysms are considered contributory factors in eventual recanalization [52, 53]. Although this particular study relied on computational fluid dynamics and therefore is of limited value in a clinical setting (given the host of complexities), its relevance in follow-up monitoring of occlusion rates after stent-assisted coil embolization of aneurysms may be considerable.
Our study has several limitations, one being the retrospective collection of data at a single center. Thus, there is a potential for bias in choice of stent. For instance, Enterprise and Neuroform (rather than LVIS) stents were more often selected for aneurysms of internal carotid artery, and the aneurysms in which they were deployed tended to be a bit larger. Choice of stent was weighed in each instance, based on merits and drawbacks, but only large-scale prospective studies will provide needed clarification. In addition, three types of stents became available at different times for a certain period, and level of coiling technique might be different in each stent. Another limitation is that TOF-MRA was used routinely for follow-up monitoring (per institutional protocol), without performing baseline MRA studies immediately postembolization. Despite the utility of TOF-MRA in gauging extent of recanalization, the stent artifacts encountered may obscure minor features [54,55,56,57], and the size of the residual flow in coiled aneurysms with stent may be underestimated, in particular in small-sized aneurysms. In our cohort, rates for aneurysms of posterior circulation (28/312, 9.0%) and of bioactive coils > 50% (33/312, 10.6%) were low. Therefore, coiled aneurysms of posterior circulation or aneurysms of bioactive coils > 50% may not be represented well in this sampling.
Conclusions
In stent-assisted coil embolization of small-sized (< 10 mm) aneurysms, stent type, as well as occlusive status at time of coiling and aneurysmal neck size, may impact outcomes during follow-up monitoring. LVIS stents seem beneficial for reducing recanalization rates in this setting, more so than Enterprise or Neuroform stents.
Change history
07 May 2018
The original version of this article contained a mistake in Fig. 4: Fig. 4a and d were interchanged. The correct figure is shown below. The original article has been corrected.
References
Lee SJ, Cho YD, Kang HS, Kim JE, Han MH (2013) Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: a single-center experience of 289 consecutive aneurysms. Clin Radiol 68:256–263
Cho YD, Kang HS, Kim JE, Cho WS, Kwon HJ, Koh HS, Han MH (2014) Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms. Neuroradiology 56:851–857
Cho YD, Kang HS, Lee WJ et al (2103) Stent-assisted coil embolization of wide-necked posterior inferior cerebellar artery aneurysms. Neuroradiology 55:877–882
Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115
Spiotta AM, Miranpuri A, Chaudry MI et al (2013) Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms. J Neurointerv Surg 5(Suppl 3):iii79–iii82
Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998
Aenis M, Stancampiano AP, Wakhloo AK, Lieber BB (1997) Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 119:206–212
Phatouros CC, Sasaki TY, Higashida RT et al (2000) Stent-supported coil embolization: the treatment of fusiform and wide-neck aneurysms and pseudoaneurysms. Neurosurgery 47:107–113
Cho YD, Sohn CH, Kang HS, Kim JE, Cho WS, Hwang G, Kwon OK, Ko MS, Park NM, Han MH (2014) Coil embolization of intracranial saccular aneurysms using the low-profile visualized intraluminal support (LVIS™) device. Neuroradiology 56:543–551
Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403
Jeon JP, Cho YD, Rhim JK, Yoo DH, Kang HS, Kim JE, Cho WS, Han MH (2016) Extended monitoring of coiled aneurysms completely occluded at 6-month follow-up: late recanalization rate and related risk factors. Eur Radiol 26:3319–3326
Cho YD, Jeon JP, Rhim JK, Park JJ, Yoo RE, Kang HS, Kim JE, Cho WS, Han MH (2015) Progressive thrombosis of small saccular aneurysms filled with contrast immediately after coil embolization: analysis of related factors and long-term follow-up. Neuroradiology 57:615–623
Gao B, Baharoglu MI, Cohen AD, Malek AM (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649–654
Cho YD, Lee WJ, Kim KM, Kang HS, Kim JE, Han MH (2013) Stent-assisted coil embolization of posterior communicating artery aneurysms. AJNR Am J Neuroradiol 34:2171–2176
Fiorella D, Albuquerque FC, Han P et al (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16
Higashida RT, Halbach VV, Dowd CF, Juravsky L, Meagher S (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756
Cho WS, Hong HS, Kang HS, Kim JE, Cho YD, Kwon OK, Bang JS, Hwang G, Son YJ, Oh CW, Han MH (2015) Stability of cerebral aneurysms after stent-assisted coil embolization: a propensity score-matched analysis. Neurosurgery 77:208–216
Phan K, Huo YR, Jia F, Phan S, Rao PJ, Mobbs RJ, Mortimer AM (2016) Meta-analysis of stent-assisted coiling versus coiling-only for the treatment of intracranial aneurysms. J Clin Neurosci 31:15–22
Cho YD, Lee JY, Seo JH, Lee SJ, Kang HS, Kim JE, Son YJ, Jung KH, Kwon OK, Han MH (2012) Does stent implantation improve the result of repeat embolization in recanalized aneurysms? Neurosurgery 71:ons253–ons259
Kim DJ, Suh SH, Lee JW, Kim BM, Lee JW, Huh SK, Kim DI (2010) Influences of stents on the outcome of coil embolized intracranial aneurysms: comparison between a stent-remodeled and non-remodeled treatment. Acta Neurochir 152:423–429
Izar B, Rai A, Raghuram K, Rotruck J, Carpenter J (2011) Comparison of devices used for stent-assisted coiling of intracranial aneurysms. PLoS One 6:e24875
Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN (2006) Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 27:1861–1865
Tateshima S, Tanishita K, Hakata Y, Tanoue SY, Viñuela F (2009) Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation. J Neurosurg 111:22–27
Vanninen R, Manninen H, Ronkainen A (2003) Broad-based intracranial aneurysms: thrombosis induced by stent placement. AJNR Am J Neuroradiol 24:263–266
Molyneux AJ, Kerr RS, Yu LM, Clarke M, Sneade M, Yarnold JA, Sandercock P, International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2005) International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 366:809–817
Ferns SP, Sprengers ME, van Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529
Ries T, Siemonsen S, Thomalla G, Grzyska U, Zeumer H, Fiehler J (2007) Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment. AJNR Am J Neuroradiol 28:1755–1761
Chalouhi N, Jabbour P, Singhal S, Drueding R, Starke RM, Dalyai RT, Tjoumakaris S, Gonzalez LF, Dumont AS, Rosenwasser R, Randazzo CG (2013) Stent-assisted coiling of intracranial aneurysms: predictors of complications, recanalization, and outcome in 508 cases. Stroke 44:1348–1353
McLaughlin N, McArthur DL, Martin NA (2013) Use of stent-assisted coil embolization for the treatment of wide-necked aneurysms: a systematic review. Surg Neurol Int 4:43
Kim BM, Kim DJ, Kim DI (2011) Stent application for the treatment of cerebral aneurysms. Neurointervention 6:53–70
Handa A, Abdo G, Yilmaz H, Lovblad KO, Lylyk P, Rüfenacht DA (2004) Efficacy and limitations of the neuroform stent system for intracranial aneurysms. Interv Neuroradiol 10(Suppl 2):62–68
Fiorella D, Albuquerque FC, Woo H, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34–42
Mohlenbruch M, Herweh C, Behrens L et al (2014) The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy. Neuroradiology 56:389–395
Poncyljusz W, Bilinski P, Safranow K et al (2015) The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registry. J Neurointerv Surg 7:524–529
Shankar JJ, Quateen A, Weill A et al (2017) Canadian Registry of LVIS Jr for treatment of intracranial aneurysms (CaRLA). J Neurointerv Surg 9:849–853
Fiorella D, Arthur A, Boulos A, Diaz O, Jabbour P, Pride L, Turk AS, Woo HH, Derdeyn C, Millar J, Clifton A (2016) Final results of the US humanitarian device exemption study of the low-profile visualized intraluminal support (LVIS) device. J Neurointerv Surg 8:894–897
Feng Z, Fang Y, Xu Y, Hong B, Zhao W, Liu J, Huang Q (2016) The safety and efficacy of low profile visualized intraluminal support (LVIS) stents in assisting coil embolization of intracranial saccular aneurysms: a single center experience. J Neurointerv Surg 8:1192–1196
Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Jankowitz BT, Liebma N KM, Rai AT, Rodriguez-Mercado R, Siddiqui AH, Veznedaroglu E, Hopkins LN, Levy EI (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39
Fargen KM, Hoh BL, Welch BG, Pride GL, Lanzino G, Boulos AS, Carpenter JS, Rai A, Veznedaroglu E, Ringer A, Rodriguez-Mercado R, Kan P, Siddiqui A, Levy EI, Mocco J (2012) Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery 71:239–244
Kim SW, Sung SO, Chae KS, Park HS, Lee SH (2015) Clinical and angiographic outcomes of aneurysms treated with two self-expanding stent-assisted coiling systems: a comparison of solitaire AB and Enterprise VRD stents. J Cerebrovasc Endovasc Neurosurg 17:149–156
King B, Vaziri S, Singla A, Fargen KM, Mocco J (2015) Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature. J Neurointerv Surg 7:905–909
Gentric JC, Biondi A, Piotin M, Mounayer C, Lobotesis K, Bonafé A, Costalat V, French SENAT Investigators (2013) Safety and efficacy of neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study. AJNR Am J Neuroradiol 34:1203–1208
Kulcsar Z, Goricke SL, Gizewski ER et al (2013) Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates. Neuroradiology 55:459–465
Maldonado IL, Machi P, Costalat V, Mura T, Bonafé A (2011) Neuroform stent-assisted coiling of unruptured intracranial aneurysms: short- and midterm results from a single-center experience with 68 patients. AJNR Am J Neuroradiol 32:131–136
Durst CR, Khan P, Gaughen J, Patrie J, Starke RM, Conant P, Liu KC, Jensen ME, Evans AJ (2014) Direct comparison of Neuroform and Enterprise stents in the treatment of wide-necked intracranial aneurysms. Clin Radiol 69:e471–e476
Ge H, Lv X, Yang X, He H, Jin H, Li Y (2016) LVIS stent versus Enterprise stent for the treatment of unruptured intracranial aneurysms. World Neurosurg 91:365–370
Dholakia R, Sadasivan C, Fiorella DJ, Woo HH, Lieber BB (2017) Hemodynamics of flow diverters. J Biomech Eng 139:021002
Wang C, Tian Z, Liu J, Jing L, Paliwal N, Wang S, Zhang Y, Xiang J, Siddiqui AH, Meng H, Yang X (2016) Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the pipeline device. J Transl Med 14:199
Palmaz JC (1993) Intravascular stents: tissue-stent interactions and design considerations. AJR Am J Roentgenol 160:613–618
Seshadhri S, Janiga G, Beuing O et al (2011) Impact of stents and flow diverters on hemodynamics in idealized aneurysm models. J Biomech Eng 133:071005
Kojima M, Irie K, Fukuda T, Hirose Y, Negoro M, Arai F (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165
Li C, Wang S, Chen J, Yu H, Zhang Y, Jiang F, Mu S, Li H, Yang X (2012) Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: a patient-specific computational fluid dynamic simulation study. J Neurosurg 117:276–283
Luo B, Yang X, Wang S, Li H, Chen J, Yu H, Zhang Y, Zhang Y, Mu S, Liu Z, Ding G (2011) High shear stress and flow velocity in partially occluded aneurysms prone to recanalization. Stroke 42:745–753
Jeon JP, Cho YD, Rhim JK, Park JJ, Cho WS, Kang HS, Kim JE, Han MH (2016) Effect of stenting on progressive occlusion of small unruptured saccular intracranial aneurysms with residual sac immediately after coil embolization: a propensity score analysis. J Neurointerv Surg 8:1025–1029
Cho YD, Kim KM, Lee WJ, Sohn CH, Kang HS, Kim JE, Han MH (2014) Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images. Korean J Radiol 15:161–168
Choi JW, Roh HG, Moon WJ, Chun YI, Kang CH (2011) Optimization of MR parameters of 3D TOF-MRA for various intracranial stents at 3.0T MRI. Neurointervention 6:71–77
van Amerongen MJ, Boogaarts HD, de Vries J, Verbeek ALM, Meijer FJA, Prokop M, Bartels RHMA (2014) MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis. AJNR Am J Neuroradiol 35:1655–1661
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Funding
No funding was received for this study.
Conflict of interest
We declare that we have no conflict of interest.
Ethical approval
All procedures performed in the studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Patient consent
For this type of study formal consent is not required.
Additional information
The original version of this article was revised: The original version of this article contained a mistake in Figure 4: Figure 4a and d were interchanged.
Electronic supplementary material
ESM 1
(DOCX 15 kb)
Rights and permissions
About this article
Cite this article
Lee, J., Cho, Y.D., Yoo, D.H. et al. Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?. Neuroradiology 60, 747–756 (2018). https://doi.org/10.1007/s00234-018-2022-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00234-018-2022-4