Abstract
Water toxicity detection is of great significance to ensure the safety of water supply. With suspended electrochemically active bacteria (EAB) as the sensing element, a novel microbial electrochemical sensor (MES) has recently been reported for the real-time detection of water toxicity, but its practical applications need to further improve the sensitivity. Extracellular electron transfer (EET) is an important factor affecting MES performance. In the study, the EET of suspended EAB–based MES was optimized to further enhance the sensitivity. Firstly, by using a model EAB stain Shewanella oneidensis MR-1, it was revealed that the sensitivity was increased at most 2.7 times with inward EET (i.e., cathodic polarization). Then, a novel conjecture based on electron transfer and energy fluxes was proposed and testified to explain this phenomenon. Finally, three key operating parameters of inward EET were orthogonally optimized. The optimized parameters of inward EET included a potential of − 0.5 V, a cell density of 1.8 × 108 CFU/mL, and an electron acceptor concentration of 15 mM.
Graphical abstract
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Acute water pollution emerges largely worldwide with the rapid development of industry and agriculture. According to the announcement issued by the United Nations, 90% of the surface water is polluted, and 1/3 of water supply safety is threatened, resulting in the death of more than 600 children every day [1, 2]. The monitoring of water quality is the key to realize the early warning of water pollution. The traditional methods for water quality monitoring are mainly based on physical or chemical detection technologies, which are capable of accurately quantifying the toxic pollutants in water [3]. However, these methods rely on large and expensive equipment, which fail to reveal the bio-toxicity and comprehensive toxicity of water. An alternative way that employs bio-elements (e.g., tissue, cell, or protein) as the indicators directly detects water toxicity, which is based on biological responses to environmental changes [4]. A series of indicators, including fish, algae, and bacteria, were reported to realize water toxicity monitoring [5]. Among these indicators, electrochemically active bacteria (EAB) with the ability of extracellular electron transfer (EET) attracted lots of attention during recent years [6]. The metabolism activity of EAB is reflected by the EET rate (i.e., current), and the current is depressed once EAB are exposed to toxic pollutants. Based on the principle, water toxicity detection is realized by measuring currents directly [7]. Compared with other bioassays, EAB are capable of detecting water toxicity without external signal transducers and the detection is independent of water color and salinity of water, showing great prospects in the field of water quality monitoring [8].
Numerous studies have proved the feasibility of EAB–based water toxicity monitoring, and a series of toxic pollutants have been successfully detected [9,10,11,12]. In these studies, EAB biofilms were used as the sensing elements, which realized self-renewal and self-maintenance [13]. However, the complex components in the biofilm, such as protein, polysaccharide, and peptidoglycan, act as a natural barrier of EAB within the biofilm, which reduces the sensitivity of toxicity detection [14]. A novel water toxicity detection method based on suspended EAB was proposed to solve this problem, which successfully detected low-concentration pollutants without forming biofilm [12, 15]. Additionally, the enhancement of sensitivity by replacing EAB biofilms with suspended EAB was first quantified, and the results showed that the sensitivity of suspended EAB in water toxicity detection was 30 times higher than that of the biofilms [16]. Nonetheless, the reported detection limit of pollutants based on suspended EAB still exceeded standard values with the tightening of the water quality standard [17]. Therefore, more efforts are eagerly needed to enhance the sensitivity of suspended EAB–based water monitoring for practical applications.
EET is related to water toxicity and EAB metabolism, and regulating EET may be an efficient way to enhance sensitivity. Based on electron transfer direction, EET includes outward EET and inward EET. With outward EET, electrons are transferred from the respiratory chain to an electrode, and currents are generated with continuous electron flow. When outward EET is reversed, electrons are transferred from an electrode to the respiratory chain and terminal electron acceptors (e.g., nitrate, fumarate, and TMAO), and this process is inward EET [18]. Most previous studies utilized the outward EET and output current of EAB as the electrical signals to monitor water quality [19]. Jiang et al. firstly employed the inward EET and input current of EAB to detect water toxicity, which aimed to avoid the change in organic matters masking the effects of toxic pollutants on the electrical signals of outward EET. Compared with outward EET, EAB with inward EET exhibited a higher water toxicity detection sensitivity, and achieved the rapid detection of 0.0005% formaldehyde [20]. This phenomenon was further confirmed by the following studies. The sensitivity with inward EET was 1–9 times higher than that with outward EET by detecting Hg2+, Cr6+, and Pb2+ [21, 22]. However, although inward EET seemed to improve water toxicity detection, the underlying mechanism of improved sensitivity was still unclear [23]. The main reason is that these studies all used mixed-culture EAB biofilms, and the reversal of the EET direction may change EAB community structure and biofilm property simultaneously [24], which were proved to be the key parameters affecting water toxicity detection. Therefore, the direct effects of EET direction on water toxicity detection remained to be revealed.
A recent study has reported a novel microbial electrochemical sensor (MES) based on suspended Shewanella oneidensis MR-1 [25], and the bidirectional EET capacity of S. oneidensis MR-1 has been proved [12, 26]. In the study, MESs based on pure cultured and suspended S. oneidensis MR-1 were used to further investigate the direct effects of EET direction on water toxicity detection. Firstly, MESs with inward and outward EET were constructed. Then, two common pollutants were tested under different EET conditions, and the differences in the sensitivity were demonstrated. After that, the electrochemical responses of outward and inward EET to a toxic shock were compared with the identical sensing element. Based on these results, the underlying mechanism of differences in the sensitivity under different EET direction conditions was revealed. Finally, three key parameters affecting the current of suspended S. oneidensis MR-1 were orthogonally optimized by using the optimized EET direction.
Materials and methods
Microbial cultivation
S. oneidensis MR-1 (ATCC 700,550) was obtained from ATCC and refrigerated at − 80 °C. Before use, S. oneidensis MR-1 was activated in Luria–Bertani medium overnight, and the aerobic incubation conditions were set as follows: 0.5% of inoculum, 22 °C of culture temperature, and 180 r/min of shaker rotational speed. After cultivation, S. oneidensis MR-1 suspension (OD600 = 2.0) was reserved at 4 °C to construct MESs.
MES construction
Eight MESs (MESs 1–8) were constructed according to our previous study [27]. All MESs were identical, and each MES was composed of a piece of 2 cm × 2 cm carbon cloth as the working electrode, 1 cm × 1 cm Pt slide as the counter electrode, and Ag/AgCl (3 M KCl) electrode as the reference electrode. The carbon cloth was immersed in acetone and heated at a high temperature before use. All components were cleaned thoroughly with double-distilled water and sterilized before use. The sterilization referred to a previous study to avoid potential damages to Ag/AgCl electrodes.
After preparation, all the MESs were divided into three groups, including outward MESs (MESs 1–3), inward MESs (MESs 4–6), and abiotic control (MESs 7–8). Both outward MESs and inward MESs (MESs 1–6) used the same electrolyte, which aimed to reveal the direct effects of EET direction on water toxicity detection. The electrolyte in MESs 1–6 included 20 mL of S. oneidensis MR-1 suspension and 20 mL of defined medium (DM). Twenty milliliters of sterile Luria–Bertani medium and 20 mL of DM medium were added to MESs 7–8. Each liter of DM contained 1 g of NaHCO3, 0.13 g of KCl, 0.027 g of CaCl2 2H2O, 0.2 g of MgCl2 6H2O, 5.85 g of NaCl, 7.2 g of HEPES, and 10 mM of trimethylamine N-oxide (TMAO). TMAO is the electron acceptor of S. oneidensis MR-1 [28]. After that, outward MESs (MESs 1–3) were used to develop the outward EET of S. oneidensis MR-1 with a constant potential of 0.5 V, and inward MESs (MESs 4–6) were used to develop the inward EET of S. oneidensis MR-1 with a constant potential of − 0.5 V. MESs 7–8 were used as abiotic control, and the working potentials of MESs 7–8 were set at 0.5 V and − 0.5 V, respectively. Finally, all currents of MESs were measured continuously, and the MESs were ready for toxic tests once the currents became stable.
Toxic tests
The spike tests were used to simulate acute toxic shocks. Each toxic test was conducted in the following three steps. First, MESs with suspended S. oneidensis MR-1 as the sensing elements were constructed, and the currents of MESs were measured. Then, a specific volume of pollutant concentrate was spiked into MESs when the currents became stable. The toxic exposure lasted for 30 min, and the currents were recorded continuously. Finally, the MESs were cleaned up, and a new piece of carbon cloth was used for the next toxic test. The response of S. oneidensis MR-1 to the toxic shock was calculated based on the inhibition ratio of the current, which was determined by using the following equation,
where I1 and I2 were the current values before and after the toxic exposure.
Bacterial viability analysis
Confocal laser scanning microscopy (CLSM) was used to analyze the viability of S. oneidensis MR-1. Before CLSM analysis, 100 μL of S. oneidensis MR-1 suspension was sampled from non-toxic inward MESs and outward MESs, respectively. After that, all MESs were shocked with 0.05 mg/L of Cd2+ for 30 min, and then the sampling was performed again. All samples were stained with a LIVE/DEAD BacLight Bacterial Viability Kit (7012, Invitrogen, USA) according to the manufacturer’s protocols and were observed with CLSM (TCS SP8, Leica, Germany). At least three locations were randomly selected for each sample. Viability was defined as the proportion of alive S. oneidensis MR-1, and it was analyzed based on the following equation,
where IntL and IntD referred to the optical intensity of alive and dead S. oneidensis MR-1, respectively.
Electrochemical measurements
Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to reveal the underlying mechanism of differences in the sensitivity between inward and outward MESs. Two MESs (randomly chosen from MESs 1–6) were refreshed and used to test the toxic shock of 0.05 mg/L Cd2+. As the MESs were capable of performing bidirectional EET, the electrochemical responses of outward and inward EET to a toxic shock were compared with the identical sensing element. CV was measured using a multi-channel potentiostat (CHI1030C, ChenHua, China), and the detailed measurement parameters were set as follows: the potential range of − 0.5 to 0.5 V and the scan rate of 1 mV/s. The currents with the potentials of 0.5 V and − 0.5 V referred to anodic limiting current and cathodic limiting current in the CV curves, which represented the electrochemical activity of anodic polarization and cathodic polarization, respectively [29]. EIS was obtained with an electrochemical station (Zennium E, Zahner, Germany) and measured with the following parameters: the frequency range of 50 mHz to 100 kHz and a small disturbance voltage of 5 mV. The obtained EIS data were analyzed with a classical electrochemical model by using Zman, which was briefly described by Rs − (Rct − W)|CPE. In this model, Rct is charge transfer resistance, which represents the electrochemical activity of S. onediensis MR-1, and Rs, W, and CPE represent ohmic resistance, diffusion resistance, and double layer capacitance, respectively.
Orthogonal optimization
Three key parameters, including cell density (representing catalyst concentration), electrode potential (representing electron donor concentration), and TMAO concentration (representing electron acceptor concentration), were optimized to improve the sensitivity of water toxicity detection based on suspended S. oneidensis MR-1 with inward EET. The orthogonal design was used to simplify experiments. Three levels of each parameter were selected, and a total of 9 experiments was designed based on normalized orthogonal table L9 (34). The detailed levels of each parameter are shown in Table 1. The range analysis was used to determine the sensitivity of factors to the experimental results according to the previous study.
Results and discussion
Current generation of S. oneidensis MR-1 with outward and inward EET
The previous studies demonstrated that suspended S. oneidensis MR-1 is capable of outward EET and inward EET, and S. oneidensis MR-1 performed outward EET and inward EET at different electrode potentials, respectively [30]. As shown in Fig. 1a, there were obvious output currents at a constant potential of 0.5 V (MESs 1–3), indicating that S. oneidensis MR-1 respired with organic matters as the electron donor and an electrode as the electron acceptor [16]. There was obvious current consumption when the electrode potential was set as − 0.5 V (MESs 4–6), which showed that S. oneidensis MR-1 respired with an electrode as the electron donor and TMAO as the electron acceptor (Fig. 1b). Additionally, both the outward and inward currents remained stable after the capacitive currents disappeared, which indicated that both outward EET and inward EET of S. oneidensis MR-1 were feasible for toxicity detection.
Notably, the baseline value of the inward current (− 105.7 μA) was obviously higher than that of the outward current (45.9 μA), and a similar phenomenon was also observed by using other EAB strains capable of bidirectional EET, which might be attributed to the fact that inward EET was more conducive to the completion of transmembrane electron transfer [31, 32]. The speculation was not suitable to explain the obtained results in this study, because S. oneidensis MR-1 was proved to utilize the same EET pathway to perform outward EET and inward EET [33]. In fact, considering the energy fluxes under different EET directions, outward EET only represented a small amount of electron transfer in the respiratory chain [34], while inward EET included all the electron transfer of the respiratory chain [35]. Therefore, an alternative explanation based on energy fluxes was more suitable; inward EET completely reflected bacterial energy metabolism, which resulted in the higher inward currents (Fig. 2). In addition, the working potentials were also different under the two EET conditions, and the higher currents might be due to the higher overpotential of inward EET. More efforts are still needed to further explain the higher currents of inward EET in future studies.
Water toxicity detection by using S. oneidensis MR-1 with outward and inward EET
Two types of MESs (outward MESs and inward MESs) were used to conduct toxic tests. The toxic pollutants tested included heavy metal (Cd2+) and organic pollutants (phenol), and the tested concentrations ranged from 0.05 to 0.5 mg/L. As shown in Fig. 3a, b, both currents of outward MESs and inward MESs decreased sharply with the addition of 0.05 mg/L Cd2+, which indicated the strong toxicity of Cd2+ for S. oneidensis MR-1 [36]. Compared with outward MESs, inward MESs exhibited a higher sensitivity. Specifically, the IR of inward MESs was 13.2% ± 1.8% under the same toxic shock of 0.05 mg/L Cd2+, while that of outward MESs was only 5.6% ± 1.4%. A similar phenomenon was also observed in the high-concentration Cd2+ detection; the IR with inward MESs was 19.8% ± 1.0%, 24.7% ± 1.4%, and 35.4% ± 1.3%, while that with outward MESs was 10.7% ± 0.8%, 18.6% ± 0.6%, and 28.7% ± 2%. In addition, the IR of inward MESs was at most 2.7 times higher than that of outward MESs for the detection of phenol, which further confirmed that inward MESs were more sensitive to the detection of toxic pollutants. Interestingly, the enhancement of toxicity detection sensitivity using inward EET instead of outward EET also varied with the concentration of pollutants. The enhancement of sensitivity became more evident with the decrease of pollutant concentration. For example, the sensitivity was increased by 2.3 times when detecting 0.05 mg/L Cd2+, while that was only increased 1.2 times for 0.5 mg/L Cd2+ detection, which indicated a unique advantage of S. oneidensis MR-1 with inward EET for detecting trace pollutants.
Viability analysis of S. oneidensis MR-1
The sensitivity differences between outward MESs and inward MESs were investigated by using variance analysis. The IR of inward MESs was significantly higher than that of outward MESs under all tested shocks, suggesting that S. oneidensis MR-1 with inward EET was more sensitive to water toxicity detection. Two possible reasons were proposed to explain the phenomenon. The first one was that inward MESs may exhibit a lower toxic resistance, and the higher sensitivity was probably due to the inactivation of more S. oneidensis MR-1 cells after toxic shocks under inward EET condition. The CLSM images of bacterial metabolism activity before and after 0.05 mg/L Cd2+ toxic shock were obtained to verify this speculation, and the viability changes after the toxic shock were calculated [16]. As shown in Fig. 4a and c, it was observed that S. oneidensis MR-1 with inward and outward EET possessed high viability before the toxic shock, reaching 95% under different EET conditions. After 30 min of 0.05 mg/L Cd2+ exposure, the viability of S. oneidensis MR-1 with both inward and outward EET decreased obviously, demonstrating the high bio-toxicity of Cd2+ [36]. However, it was interesting to reveal that the decline of viability was basically the same under different EET conditions. Specifically, the viability of S. oneidensis MR-1 decreased from 95.18% ± 2.14% to 89.66% ± 1.64% under the inward EET condition, while that decreased from 96.85% ± 2.27% to 89.51% ± 4.68% under the outward EET condition. Therefore, the first speculation cannot explain the observation that the sensitivity was enhanced by using inward EET, and there was another reason for the higher sensitivity of S. oneidensis MR-1 under the inward EET condition.
Another reason may be that the slight damages of cell metabolism cannot induce the reduction of outward EET current directly. The previous studies also reported that the output currents remained unchanged even if the metabolic activity of EAB was significantly inactivated [22, 37]. These phenomena demonstrated that the output currents of EAB failed to reflect bacterial activity accurately, which was probably because outward EET was only part of the electron transfer in the respiratory chain. Differently, inward EET included all the electron transfer of the respiratory chain, and it was reasonable that the slight inhibition of cell metabolism would decrease the input current directly. The results of toxic tests partly confirmed this conjecture, and the sensitivity enhancement with inward EET was more obvious when detecting low-concentration pollutants. Therefore, it was assumed that different energy fluxes under the two EET conditions were the main reason for the higher sensitivity with inward EET, which remained to be testified in the following studies.
Mechanism of the enhanced sensitivity with inward EET
CV curves of MESs capable of bidirectional EET before and after 30 min of 0.05 mg/L Cd2+ exposure were obtained to further testify the conjecture (Fig. 5a–c). Before the toxic test, CV curves exhibited obvious anodic and cathodic polarization with the applied potential of 0.5 V and − 0.5 V, which confirmed the bidirectional EET capacity of suspended S. oneidensis MR-1 [38]. The cathodic polarization decreased significantly after the toxic exposure, and the limiting current of cathodic polarization decreased 17.0% ± 4.5% (from − 147.3 to − 117.6 μA). However, the anodic polarization remained basically unchanged after the toxic exposure, and the limiting current of anodic polarization only slightly decreased 4.1% ± 1.0% (from 120.5 to 116.4 μA). The anodic and cathodic polarization reflected the electrochemical activity of outward EET and inward EET, respectively [39], and the results indicated that inward EET and input currents of EAB were more sensitive to toxic shocks. EIS data further confirmed this conclusion. As shown in Fig. 5e–g, the Rct of cathodic polarization increased 41.7% (from 586.3 Ω ± 3.5 Ω to 830.7 Ω ± 5.4 Ω) with a MES capable of bidirectional EET, while that of anodic polarization only increased 12.3%. Therefore, inward EET of EAB more efficiently reflected the changes of cell metabolism, resulting in the higher sensitivity for water toxicity detection in this study.
The previous studies also reported that mixed cultured EAB exhibited higher sensitivity for water toxicity detection after reversing outward EET to inward EET [19]. However, EAB community structure and biofilm properties vary with the direction of EET, and the mechanism of enhanced sensitivity with inward EET remained unclear. In the study, pure cultured and suspended S. oneidensis MR-1 was utilized, and all the MESs used the same electrolyte. In this way, the direct effects of EET direction on the sensitivity were revealed with a MES capable of bidirectional EET. In addition, this study first confirmed that the enhanced sensitivity was because inward EET reflected metabolism activity completely. Nonetheless, the coexistence of organic matters and TMAO may deteriorate cathodic polarization. Therefore, it is suggested using an electrode as the sole electron donor in practical applications.
Orthogonal optimization to enhance the sensitivity with inward EET
Cell density, electrode potential, and electron acceptor concentration are three key parameters determining the input currents of EAB, which affect the sensitivity of water toxicity detection. The detailed effects of these three parameters on the IR of suspended S. oneidensis MR-1 were investigated by orthogonal optimization. As shown in Table 2, three parameters had significant effects on IR. Specifically, the k value of cell density increased from 20.1 to 22.8 with the decrease of cell density, indicating that the decrease of cell density was suitable for water toxicity detection, which was also consistent with the results in the recent study [12]. Higher IR was obtained with a lower-potential electrode and higher-concentration TMAO, which suggested that the efficient electron donor and acceptor benefited the detection of water toxicity. However, different results were reported in the previous study, which revealed that the decrease of organic matters enhanced the sensitivity of water toxicity detection when using EAB with outward EET as the sensing element [40]. Compared with the previous studies, the obvious difference indicated that the substrate concentration had completely different effects on the sensitivity with different EET directions. Notably, the baseline current of EAB was positively associated with the substrate concentration; only the sensitivity and baseline current of EAB with inward EET was capable of being enhanced simultaneously. By using range analysis, the order of effects of the three parameters on IR was as follows: electrode potential > TMAO concentration > cell density. Additionally, the highest sensitivity was obtained with a cell density of 1.8 × 108 CFU/mL, an electrode potential of − 0.5 V, and a TMAO concentration of 15 mM.
Conclusion
The study revealed the effects of EET direction on the sensitivity of water toxicity detection based on suspended S. oneidensis MR-1, and further investigated the underlying mechanism. Compared with outward EET, inward EET improved the detection of low-concentration pollutants, and the sensitivity was enhanced at most 2.7 times. This was because inward EET includes all the electron transfer of the respiratory chain, and is capable of more effectively reflecting bacterial viability. The three key parameters of inward EET were optimized to further improve water toxicity detection. The highest sensitivity was obtained with a potential of − 0.5 V, a cell density of 1.8 × 108 CFU/mL, and an electron acceptor concentration of 15 mM, which provides a guide for practical applications.
References
Gamage SD, Ambrose M, Kralovic SM, Roselle GA. Water safety and health care: preventing infections caused by opportunistic premise plumbing pathogens. Infect Dis Clin North Am. 2021;35(3):667–95.
Wang H, Xi H, Xu LL, Jin MK, Zhao WL, Liu HJ. Ecotoxicological effects, environmental fate and risks of pharmaceutical and personal care products in the water environment: a review. Sci Total Environ. 2021;788:147819.
Gupta N, Renugopalakrishnan V, Liepmann D, Paulmurugan R, Malhotra BD. Cell-based biosensors: recent trends, challenges and future perspectives. Biosens Bioelectron. 2019;141:111435.
Hassan SHA, Gurung A, Kang WC, Shin BS, Rahimnejad M, Jeon BH, Kim JR, Oh SE. Real-time monitoring of water quality of stream water using sulfur-oxidizing bacteria as bio-indicator. Chemosphere. 2019;223:58–63.
Moraskie M, Roshid MHO, O’Connor G, Dikici E, Zingg JM, Deo S, Daunert S. Microbial whole-cell biosensors: current applications, challenges, and future perspectives. Biosens Bioelectron. 2021;191:113359.
Do MH, Ngo HH, Guo WS, Chang SW, Nguyen DD, Liu YW, Varjani S, Kumar M. Microbial fuel cell-based biosensor for online monitoring wastewater quality: a critical review. Sci Total Environ. 2020;712:135612.
Qi X, Wang SY, Jiang Y, Liu PP, Li QC, Hao W, Han JB, Zhou YX, Huang X, Liang P. Artificial electrochemically active biofilm for improved sensing performance and quickly devising of water quality early warning biosensors. Water Res. 2021;198:117164.
Fang DY, Gao GY, Yang YJ, Wang Y, Gao LJ, Zhi JF. Redox mediator-based microbial biosensors for acute water toxicity assessment: a critical review. ChemElectroChem. 2020;7(12):2513–26.
Nakamura H. Current status of water environment and their microbial biosensor techniques - Part II: recent trends in microbial biosensor development. Anal Bioanal Chem. 2018;410(17):3967–89.
Lazzarini Behrmann IC, Grattieri M, Minteer SD, Ramirez SA, Vullo DL. Online self-powered Cr(VI) monitoring with autochthonous Pseudomonas and a bio-inspired redox polymer. Anal Bioanal Chem. 2020;412(24):6449–57.
Pasco NF, Weld RJ, Hay JM, Gooneratne R. Development and applications of whole cell biosensors for ecotoxicity testing. Anal Bioanal Chem. 2011;400(4):931–45.
Yang Y, Wang YZ, Fang Z, Yu YY, Yong YC. Bioelectrochemical biosensor for water toxicity detection: generation of dual signals for electrochemical assay confirmation. Anal Bioanal Chem. 2018;410(4):1231–6.
Qi X, Wang SY, Li T, Wang X, Jiang Y, Zhou YX, Zhou XH, Huang X, Liang P. An electroactive biofilm-based biosensor for water safety: pollutants detection and early-warning. Biosens Bioelectron. 2021;173:112822.
Flemming HC, Wingender J, Szewzyk U, Steinberg P, Rice SA, Kjelleberg S. Biofilms: an emergent form of bacterial life. Nat Rev Micro. 2016;14(9):563–75.
Yang Y, Fang Z, Yu YY, Wang YZ, Naraginti S, Yong YC. A mediator-free whole-cell electrochemical biosensing system for sensitive assessment of heavy metal toxicity in water. Water Sci Technol. 2019;79(6):1071–80.
Zang YX, Zhao T, Xie BZ, Feng Y, Yi Y, Liu H. A bio-electrochemical sensor based on suspended Shewanella oneidensis MR-1 for the sensitive assessment of water biotoxicity. Sensors Actuat B-Chem. 2021;341:130004.
Jiang Y, Yang XF, Liang P, Liu PP, Huang X. Microbial fuel cell sensors for water quality early warning systems: fundamentals, signal resolution, optimization and future challenges. Renew Sust Energy Rev. 2018;81:292–305.
Zhao JT, Li F, Cao YX, Zhang XB, Chen T, Song H, Wang ZW. Microbial extracellular electron transfer and strategies for engineering electroactive microorganisms. Biotechnol Adv. 2021;53:107682.
Chu N, Liang QJ, Hao W, Jiang Y, Liang P, Zeng RJ. Microbial electrochemical sensor for water biotoxicity monitoring. Chem Eng J. 2021;404.
Jiang Y, Liang P, Liu PP, Wang DL, Miao B, Huang X. A novel microbial fuel cell sensor with biocathode sensing element. Biosens Bioelectron. 2017;94:344–50.
Prevoteau A, Clauwaert P, Kerckhof FM, Rabaey K. Oxygen-reducing microbial cathodes monitoring toxic shocks in tap water. Biosens Bioelectron. 2019;132:115–21.
Zhao T, Xie BZ, Yi Y, Liu H. Sequential flowing membrane-less microbial fuel cell using bioanode and biocathode as sensing elements for toxicity monitoring. Bioresource Technol. 2019;276:276–80.
Chu N, Liang QJ, Hao W, Jiang Y, Zeng RJ. Micro-microbial electrochemical sensor equipped with combined bioanode and biocathode for water biotoxicity monitoring. Bioresource Technol. 2021;326:124743.
Liao CM, Wu JL, Zhou L, Li T, Du Q, An JK, Li N, Wang X. Optimal set of electrode potential enhances the toxicity response of biocathode to formaldehyde. Sci Total Environ. 2018;644:1485–92.
Rowe AR, Rajeev P, Jain A, Pirbadian S, Okamoto A, Gralnick JA, El-Naggar MY, Nealson KH. Tracking electron uptake from a cathode into Shewanella cells: implications for energy acquisition from solid-substrate electron donors. MBio. 2018;9:e02203-e2217.
Si RW, Zhai DD, Liao ZH, Gao L, Yong YC. A whole-cell electrochemical biosensing system based on bacterial inward electron flow for fumarate quantification. Biosens Bioelectron. 2015;68:34–40.
Yi Y, Zhao T, Zang YX, Xie BZ, Liu H. Different mechanisms for riboflavin to improve the outward and inward extracellular electron transfer of Shewanella loihica. Electrochem Commun. 2021;124:106966.
Lemaire ON, Honore FA, Jourlin-Castelli C, Mejean V, Fons M, Iobbi-Nivol C. Efficient respiration on TMAO requires TorD and TorE auxiliary proteins in Shewanella oneidensis. Res Microbiol. 2016;167(8):630–7.
Pous N, Carmona-Martinez AA, Vilajeliu-Pons A, Fiset E, Baneras L, Trably E, Balaguer MD, Colprim J, Bernet N, Puig S. Bidirectional microbial electron transfer: switching an acetate oxidizing biofilm to nitrate reducing conditions. Biosens Bioelectron. 2016;75:352–8.
Kracke F, Vassilev I, Kroemer JO. Microbial electron transport and energy conservation - the foundation for optimizing bioelectrochemical systems. Front Microbiol. 2015;6:575.
Yu LP, Yuan Y, Rensing C, Zhou SG. Combined spectroelectrochemical and proteomic characterizations of bidirectional Alcaligenes faecalis-electrode electron transfer. Biosens Bioelectron. 2018;106:21–8.
Yu YY, Wu YC, Cao B, Gao YG, Yan XL. Adjustable bidirectional extracellular electron transfer between Comamonas testosteroni biofilms and electrode via distinct electron mediators. Electrochem Commun. 2015;59:43–7.
Ross DE, Flynn JM, Baron DB, Gralnick JA, Bond DR. Towards electrosynthesis in Shewanella: energetics of reversing the Mtr pathway for reductive metabolism. Plos One. 2011;6(2):e16649.
Logan BE. Exoelectrogenic bacteria that power microbial fuel cells. Nat Rev Microbiol. 2009;7(5):375–81.
Zheng TW, Li J, Ji YL, Zhang WM, Fang Y, Xin FX, Dong WL, Wei P, Ma JF, Jiang M. Progress and prospects of bioelectrochemical systems: electron transfer and its applications in the microbial metabolism. Front Bioeng Biotech. 2020;8:10.
Yang YJ, Fang DY, Liu YR, Liu RZ, Wang XS, Yu Y, Zhi JF. Problems analysis and new fabrication strategies of mediated electrochemical biosensors for wastewater toxicity assessment. Biosens Bioelectron. 2018;108:82–8.
Yi Y, Xie BZ, Zhao T, Qian ZN, Liu H. Effect of control mode on the sensitivity of a microbial fuel cell biosensor with Shewanella loihica PV-4 and the underlying bioelectrochemical mechanism. Bioelectrochemistry. 2019;128:109–17.
Yi Y, Zhao T, Xie BZ, Zang YX, Liu H. Dual detection of biochemical oxygen demand and nitrate in water based on bidirectional Shewanella loihica electron transfer. Bioresour Technol. 2020;309:123402.
Liang DD, He WH, Li C, Yu YL, Zhang ZH, Ren NQ, Feng YJ. Bidirectional electron transfer biofilm assisted complete bioelectrochemical denitrification process. Chem Eng J. 2019;375:121960.
Jiang Y, Liang P, Liu PP, Bian YH, Miao B, Sun XL, Zhang HL, Huang X. Enhancing signal output and avoiding BOD/toxicity combined shock interference by operating a microbial fuel cell sensor with an optimized background concentration of organic matter. Int J Mol Sci. 2016;17(9):1392.
Acknowledgements
This work was financially supported by grants from the National Natural Science Foundation of China [31770135], Beijing Institute of Technology Research Fund Program for Young Scholars [3160011182123], and the Fundamental Research Funds for the Central Universities.
Author information
Authors and Affiliations
Contributions
Yuxuan Zang: methodology, investigation, validation, data curation, visualization, and writing—original draft. Hongyu Zhao: formal analysis. Bo Cao: writing—review and editing. Beizhen Xie: investigation and funding acquisition. Yue Yi: investigation, conceptualization, methodology, writing—original draft, writing—review and editing, and funding acquisition. Hong Liu: supervision and funding acquisition.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Zang, Y., Zhao, H., Cao, B. et al. Enhancing the sensitivity of water toxicity detection based on suspended Shewanella oneidensis MR-1 by reversing extracellular electron transfer direction. Anal Bioanal Chem 414, 3057–3066 (2022). https://doi.org/10.1007/s00216-022-03919-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-022-03919-6