Abstract
The increasing demands of highly precise industrial products lead to continuous seeking for the improvements in cabapility of manufacturing machines, i.e., machine tools. Machine tools include different types of manufacturing machines, i.e., turning, lathe, drilling, and milling machines whatever computerized numerical control (CNC) type or manual type. The cabaplity improvement in machine tools requires a real understanding of their productivity, accuracy, and operating parameters, i.e., their geometrical errors. These errors can be accurately identified through measurements with highly accurate measuring instruments. These machine errors have different error sources. The angular errors, horizontal and vertical straightness errors, paralleism errors, and squarness errors are clear examples for these sources. In this work, a comparative study for the determination of machine tools errors is carried out. Two main instruments of laser interferometer system and autocollimator system are used. The geometric errors are identified, measured, and analyzed.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
The field of machine tool metrology has a strong contribution in industrial production. The family of machine tools includes different types of production machines, i.e., turning, lathe, drilling and milling machines with computerized numerical control (CNC) type or manual type. Understanding of geometrical errors of these machines is very important to improve their performance and capabilities which reflects on the accuracy of their products. Errors of machine tools error can be identified as the differences between the actual tool position and the programmed one [1]. These differences can be due to the errors in the machine tool itself, control, and measuring system errors and errors arising from the process of manufacturing or the environment. The machine tool errors can be divided into two main types; systematic and random errors. Systematic errors can be compensated with an accuracy depending mainly on their identification precision. Random errors may be due to the fluctuation in environmental temperature. Random errors need to be adapted and controlled [2]. In general, the sources of errors can be mainly due to one of three kinds of errors: (I) thermal errors due to temperature variation of the machine tool’s subassemblies caused by their work. (II) Thermal stability on the floor shop and the accumulation of heat in the machine tool’s closed spaces affect its precision. A change in ambient temperature by a few degrees celsius may result in spindle displacement by as many as tens of micrometers. (III) Geometrical errors that describe the machine tool precision. For I and II error kinds, their effects can be reduced to minimum effect through controlling of the environmental temperature and temperature rising during the production process. For III error kind, the errors should be well identified, measured, and compensated through the CNC control system [3]. The geometrical errors of machine tools are not straightforward to be simply determined. Types of geometrical error components depend on the machine tool design, mainly on the number of controlled linear and rotational axes, Fig. 1. The number of geometrical errors differs from machine tool type to another [4, 5]. For three-axes machine type, there are 21 component errors, 9 of angular errors (pitch, yaw and roll) in X, Y, and Z axes, 3 linear positioning errors, 3 horizontal straightness, 3 vertical straightness, and 3 squareness errors in the three axes.
The measuring instruments and methods that used to identify these geometrical errors can be indirect and direct methods [2, 6, 7]. Indirect methods may be double ball bars (DBB) and optical cross grids. The accurate standards are used as quick identification the machine tool’s accuracy and its errors. The ball bar specifications can be as follows: accuracy of ± 1.25 mm, resolution of 0.1 mm, and maximum sampling rate of 1000 per second. The cross-grid method serves mainly the purpose of evaluating static and dynamic machine tool errors.
Direct methods [5,6,7,8,9] include optical and electronic measuring instruments, i.e., autocollimators, 1D laser interferometer system, laser ball bars, 3D LBB instrument, and tracking lasers with/without active target, which are examples of such methods [10,11,12,13]. The autocollimators and 1D laser interferometer system comes in the first as the most versatile and more precise instruments among all instruments that used in geometrical error determination and accuracy identification of machine tools [14, 15].
Although, there are previous research work in geometrical error determination of machine tools. The new issue in this work is that most of the errors are determined in one solid work. The most important thing also is the application of geometrical error determination for a CNC machine that used for the manufacturing of aircrafts parts. The manufacturing and re-machining processes of such parts require using high accurate CNC machine tools.
In this work, the geometrical errors of computerized numerical controlled (CNC) machine of vertical turning centering (VTC) type are comparatively determined, Fig. 2. The machine is composed of moving carriage in X and Z axes with multi-level (6 latches or positions) in Z direction, and rotary base. These geometrical errors are yaw, pitch, straightness, squareness, parallelism of carriage and spindle, and flatness of rotary base.
2 Methods and procedure
In this paper, two techniques of laser interferometer system and autocollimator system are used in determination of geometrical errors of machine tool. The laser interferometer system is a heterodyne type with 10 nm resolution, 5529A model and manufactured by Agilent — USA. The autocollimator system is of high-resolution type with 0.05 arc resolution, Elcomat 3000 model, and manufactured by Moeller-Wedel — Germany. There are some hand tools; precision dial gauges and long straight edge are also used.
2.1 Laser interferometer system
The laser interferometer system that was used in this study is working based on principle of displacement measurements using optical interference. It has in simply way one laser beam with two frequencies f1 and f2 splitted by the beam splitter into two; one beam (f1) is moving arm “moveable cube corner reflector” and the other (f2) is fixed arm “fixed cube corner reflector,” Fig. 3 [14, 15].
As the moving arm moves, a number of fringes are constructed. By multiplying the fringe number by half of the wave length of laser beam, the path difference between the two beams is calculated. This path difference represents the linear distance that the moveable arm is moved. This optical setup is used for linear measurements. For other measurement types, the types of optics and their setup are changed according to each experimental measurement application. In general, all measurements that can be done by laser interferometer system is based the determination of path difference between the two beams f1 and f2, Fig. 4. These measurements are angular measurements (yaw and pitch), straightness, squareness, parallelism, and flatness measurements.
Practical setups for measurements of angular errors (yaw and pitch), straightness, squareness, and flatness measurements are shown in Figs. 5, 6, 7, and 8 respectively.
2.2 Autocollimator system
The autocollimator is an optical instrument which measures angular displacements of a mirror or other suitable reflecting surfaces. It is mainly designed to measure small angles [16]. The image of an illuminated object, located in the rear focal plane of the collimator lens, is projected to infinity and reflected via a mirror, as in Fig. 9.
The image is picked up by a light sensitive receiver. A slight alteration of the angle between the optical axis of the autocollimator and the mirror causes a deviation which can be determined very precisely. The electronic autocollimator type provides measurement of smallest deviation of inclination in two orthogonal axes in fractions of arc seconds. This optical design of autocollimator can be used for measurements of angular errors (yaw and pitch), straightness, squareness, parallelism and flatness, Figs. 10, 11, and 12.
2.3 Hand tools
Some simple tools and standards are used in determination of errors of the machine. These are dial indicator and straight edge. The straight edge is used in the determination of straightness, parallelism, and squareness of the machine as shown in Fig. 10. The dial is inserted in the tool position and touches the edge along its length in different orientation.
3 Experimental results
Five types of geometrical errors of the VTC CNC machine are measured. These errors are angular errors, straightness, squareness, parallelism, and flatness errors.
3.1 Angular errors
The angular errors of pitch and yaw errors are measured for moving range of machine. One setup of autocollimator system is used to measure pitch and yaw errors in the same time. The laser interferometer system measures these two error types individually where the optical elements are oriented one time in horizontal position and once more in vertical position. The angular errors are measured in arc second (arcs) unit for both axes X and Z. The results for angular measurements are presented in Tables 1 and 2 and Figs. 13, 14, 15, and 16.
3.2 Straightness measurements
The out of straightness for moving spindle is measured. This geometric property is measured for horizontal and vertical straightness. Also, one setup of autocollimator system is used to measure straightness errors in the same time. The laser interferometer system measures these error types individually where the optical elements are oriented, one time is horizontal position, and once more in vertical position. The horizontal and vertical straightness errors are measured for both axes X and Z. The results for straightness measurements are presented in Tables 3 and 4 and Figs. 17, 18, 19, and 20.
3.3 Squareness measurements
The out of squareness for moving spindle is measured. This geometric property is measured between X axis and Z axis. The autocollimator system is used to measure straightness in X axis and then the straightness is measured in Z axis. The laser interferometer system measures these error type individually where the optical elements are oriented one time in horizontal position and once more in vertical position. The squareness errors are measured by both instruments in addition to straight edge. The results for squareness measurements are presented in Table 5 and Fig. 21.
3.4 Parallelism measurements
The out of parallelism for moving spindle is measured. This geometric property is measured for both of X axis and Z axis. The laser interferometer system and Autocollimator System are used to measure straightness in X axis and then the straightness is measured in X′ axis. The same measurements are repeated for Z axis. From two straightness measurements at each axis, the out of parallelism is determined. The parallelism errors are measured by both instruments in addition to straight edge. The results for parallelism measurements are presented in Table 6 and Figs. 22 and 23.
3.5 Flatness measurements
The rotary base plate is calibrated for its out of flatness based on Union-Jack method, Fig. 24. Eight generators (lines) are used as guides for measurement of heights at spaced-points by 100 mm (4 inches). The plate is calibrated by both laser and autocollimator systems, Table 7 and Fig. 25.
4 Discussion
4.1 Angular errors
The measurements of angular errors in X axis are ranged from 26.6 to 29.56 arcs for pitch measurements and 10.4 to 32.56 arcs for yaw measurements. It appears a difference between laser interferometer and autocollimator for pitch measurements ~ 3 arcs and ~ 22 arcs for yaw measurements. As in Fig. 26a, the measurement results give a difference about 3 arcs between laser interferometer and autocollimator which represent ~ 10% difference less for autocollimator. In Fig. 26b, the results by autocollimator are about the third value of the results by laser interferometer. In some cases, the complicated optical setup of laser system allows the reasons for rising errors in measurements for the machine under test.
For Z axis, the measurements of angular errors are ranged from 0.8 to 4.21 arcs for pitch measurements and 1.2 to 2.26 arcs for yaw measurements. As in Fig. 27 a and b, the measurement results by autocollimator represent about 20% and 50% of the measurement results by laser interferometer for pitch and yaw measurements respectively. This shows an advantage for using of autocollimator in comparison to laser interferometer in this kind of measurements.
4.2 Straightness errors
The measurements of straightness errors resulted in lower values by autocollimator in comparison to either laser interferometer or straight edge.
For X axis, the measurement results for horizontal straightness are 10.91 µm by autocollimator, 40.52 µm by laser interferometer, and 181 µm by straight edge. The measured straightness errors by autocollimator are about 25% and 5% of that by laser interferometer and straight edge respectively. The vertical straightness measurements in X axis resulted in straightness errors of 29.39 µm by autocollimator, 161.61 µm by laser interferometer and 164 µm by straight edge, Fig. 28 a and b. The measured straightness errors by autocollimator are about 20% of that by either laser interferometer or straight edge.
For Z axis, the horizontal straightness measurements give straightness errors of 1.06 µm by autocollimator, 11.9 µm by laser interferometer, and 28 µm by straight edge. The measured straightness errors by autocollimator are about 5% and 10% of that by laser interferometer and straight edge respectively. The straightness errors for vertical straightness measurements are 0.58 µm by autocollimator, 7.76 µm by laser interferometer, and 26 µm by straight edge, Fig. 29. The measured straightness errors by autocollimator are about 2% and 8% of that by laser interferometer and straight edge respectively.
4.3 Squareness errors
The measurements of squareness errors resulted in lower values by laser interferometer in comparison to either autocollimator or straight edge. It is − 0.003 arcs by laser interferometer, − 8.28 arcs by autocollimator, and 2.4 arcs by straight edge, Fig. 30. The measured squareness errors by laser interferometer are about 0.05% and 0.2% of that by autocollimator and straight edge respectively. The laser interferometer has especially at this type of measurements one fixed setup for the laser head and beam splitter; this may improve the squareness measurements by laser interferometer.
4.4 Parallelism errors
The measurements of parallelism errors resulted in lower values by autocollimator in comparison to either laser interferometer or straight edge. It is 0.5 arcs by autocollimator, − 166.415 arcs by laser interferometer, and 3.1 arcs by straight edge in X axis. For Z axis, it is − 0.32 arcs for autocollimator, − 21.582 arcs by laser interferometer, and 0.66 arcs by straight edge, Fig. 31. This shows an advantage for using of autocollimator in comparison to laser interferometer and straight edge in this kind of measurements.
4.5 Flatness errors
The measurements of flatness deviations of machine rotary base resulted in lower values by autocollimator in comparison to laser interferometer about 10% less. It is 100.14 µm by autocollimator, 112.38 µm by laser interferometer, Fig. 32. This difference may be due to foot spacer distance for the mirror carriage of reflected mirror for autocollimator (100 mm). For laser interferometer, it is 4 inches (101.4 mm). This 1.4 mm may cause in this 10% difference in results.
5 Conclusions
The geometric errors of angular errors (pitch and yaw), horizontal straightness, vertical straightness, squareness, parallelism, and flatness deviations are measured. The measuring instruments of autocollimator and laser interferometer are used in all measurement types. A standard straight edge is used in some measurements, straightness, squareness, and parallelism. The measurements by autocollimator resulted in clear difference of the measured errors in comparison to laser interferometer in all types except at squareness measurements. The complicated optics setup for laser interferometer in some measurement types may add some additional errors sources that propagate the measured errors. Even though, laser interferometer is still powerful and precise measuring instrument in calibration of CNC machines. The straight edge is capable to be used in straightness, squareness, and parallelism measurements. It gives an easy portable tool in quick assessment of machine tools.
Abbreviations
- CNC machine:
-
Computerized numerical controlled machine
- CCD camera:
-
Charged-coupled device camera
- VTC machine:
-
Vertical turning-center machine
- arcs:
-
Arc second
References
Xing K, Achiche S, Esmaeili S, Mayer JRR (2018) Comparison of direct and indirect methods for five-axis machine tools geometric error measurement. Procedia CIRP 78:231–236
Soori M, Arezoo B, Habibi M (2013) Dimensional and geometrical errors of three-axis CNC milling machines in a virtual machining system. Comput Aided Des 45:1306–1313
Chen B, Zhang E, Yan L, Li C, Tang W, Feng Q (2009) A laser interferometer for measuring straightness and its position based on heterodyne interferometry. Rev Sci Instrum 80:115113
Postlethwaite SR, Ford DG, Morton D (1997) Dynamic calibration of CNC machine tools. J Mach Tools Manufact 37(3):287–294
Yu TX et al (2022) Improved closed-loop tracking interferometer measurement for a five-axis machine tool with a bi-rotary milling head. Sci China Technol Sci 65(5):1127–1136
Raksiri C, Parnichkun M (2004) Geometric and force errors compensation in a 3-axis CNC milling machine. Int J Mach Tools Manuf 44:1283–1291
Lou Y, Yan L, Chen B, Zhang S (2017) Laser homodyne straightness interferometer with simultaneous measurement of six degrees of freedom motion errors for precision linear stage metrology. Opt Express 25(6):6805–6821
Budzyn G, Rzepka J, Kaluza P (2021) Laser interferometer-based instrument for 3D dynamic measurements of CNC machines geometry. Opt Lasers Eng 142:106594
Acostaa D, Velázqueza J, Albajeza JA, Yagüea JA, Lope MA (2013) Machine tool verification according to machine configuration. Procedia Engineering 63:700–709
Usop Z, Sarhan AAD, Mardi NA, Wahab MNA (2015) Measuring of positioning, circularity and static errors of a CNC vertical machining centre for validating the machining. Measurement 61:39–50
Chen J-R, Ho B-L, Lee H-W, Pan S-P, Hsieh T-H (2018) Research on geometric errors measurement of machine tools using auto-tracking laser interferometer. World J Eng Technol 6:631–636
ISO 230–1 (2012)Test code for machine tools— Part 1: geometric accuracy of machines operating under no-load or quasi-static conditions
Soori M, Arezoo B, Habibi M (2014) Virtual machining considering dimensional, geometrical and tooldeflection errors in three-axis CNC milling machines. J Manuf Syst 33:498–507
Zahwi S, Amer M, Abdou MA, and Elmelegy A (2010) Calibration of surface plates using autocollimator, laser systems and coordinate measuring machines (CMMs)”, 10th International Symposium on Measurement and Quality Control (ISMQC), pp.144–147
Wuerz LJ and Quenelle RC (1983) Laser interferometer system for metrology and machine tool applications Precision Eng 5(3)
Zahwi S, Amer M, Abdou MA, Elmelegy A (2013) On the calibration of surface plates”. Measurement 46:1019–1028
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).
Author information
Authors and Affiliations
Contributions
The corresponding author “Ahmed Elmelegy” takes part in and contributes in all steps in research, preparation, experimental design, measurements, data collection, analysis, paper preparation, and writing and put it in final shape. Author “Sarwat Zahwi” contributes in data analysis and paper revision.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Elmelegy, A., Zahwi, S. Comparative study of error determination of machine tools. Int J Adv Manuf Technol 124, 4575–4602 (2023). https://doi.org/10.1007/s00170-022-10358-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00170-022-10358-1