Abstract
As 3D-printed concrete is more time efficient and environmentally friendly than conventional concrete, its development has accelerated over the past couple of years. The concrete is poured layer by layer in this system until the required dimensions are achieved. As studies related to 3D-printed concrete are limited, it is imperative to study its fire performance. In this research, using Finite Element Analysis (FEM) software, 3D-printed concrete walls with different openings have been analyzed to find the most effective wall configuration against high temperatures under the loaded condition. The results would show the most optimal wall opening when the load bearing 3D-printed concrete (3DPC) walls are exposed to high temperatures. In this study, 16 different models were analyzed and studied. It was found that the solid wall with no opening showed superior results against temperature when compared to the other walls, and the BR1 wall with a rectangular opening showed better results when compared to the other walls with openings. The displacement and stresses of each of the 3D-printed concrete wall models were also obtained.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
Concrete is one of the most widely used modern building materials. Three-dimensional-printed concrete is a relatively new concept that has been getting more attention in recent times. The concrete mixture used here consists of water, cement, and aggregates, which is designed to be easily extruded through the nozzle of the 3D-printing equipment. The structures are built with the concept of layering where a layer will be deposited on a previously poured layer repeatedly until the required structure is formed. Firstly, a model will be created, and then, the co-ordinates will be converted into code and that will be fed into the 3D printer. Using 3D-printed concrete is cost-effective as it eliminates the need for casting concrete into molds or framework. The need for intensive labor is avoided in this process, and complex geometric structures can be easily created within a tight schedule with minimal chances of human error. It also helps in reducing construction waste, which makes it environmentally friendly. Three-dimensional-printed concrete can achieve a curing time as short as three days, allowing for the rapid construction of entire structures within hours, making it time efficient. These factors help us to understand that the 3D-printed concrete is a relatively quicker and cheaper alternative to conventional concrete. Paul et al. [1] talked about the advantages of the 3D-printed concrete and the materials that are used. One of the major advantages is that it is easier to design even the complex geometries rapidly. Fine particles are used significantly in 3DPC, but the coarse aggregates are not generally used. The most commonly used materials are cement, sand, water, fly ash, silica fume, super plasticizer, and fiber particles additionally to improve the tensile strength and toughness of 3DPC. Lyu et al. [2] explained the basic principles and process of concrete 3D-printing technology and also give detailed review of the material properties. The mechanical properties of the 3D-printed concrete are in research and development stage, and hence, it can be used for low-rise buildings but cannot be used for high-rise buildings in one print, but the parts can be printed separately and later assemble it, like pre-fabricated buildings. Only high strength concrete can be used in 3DPC for more strength, ordinary cement which cannot meet the requirements for the performance of the building. Adding fiber to the 3DPC will help in increasing the tensile strength and the toughness. A numerical model was developed by Wolfs et al. [3] to analyze the behavior of 3D-printed concrete. The model focused on studying the linear stress–strain relationship of the material until failure occurred. In order to obtain the necessary material properties, compression tests and direct shear tests were conducted. The findings revealed that as the fresh concrete ages, there is a linear increase in both Young’s modulus and cohesion. However, the Poisson’s ratio remained constant at 0.3, which was determined from the lateral deformations observed during the compression test, while the angle of internal friction also remained unchanged. In a study conducted by Suntharalingam et al. [4], the performance of different types of 3D-printed concrete walls, including solid, cavity, and composite walls, was examined in relation to their behavior under fire. The findings indicated that when exposed to standard fire conditions, non-load-bearing cavity walls made of 3D-printed concrete did not exhibit as good performance as solid 3D-printed concrete walls. EN 1992-1-2 [5] provides details about the thermal properties of concrete that incorporates siliceous and calcareous aggregates at elevated temperatures. This includes information on thermal conductivity, specific heat, and density. Marais et al. [6] analyzed the performance of high strength concrete and lightweight foam concrete under high temperatures. The results showed that the materials with high thermal conductivity perform well as 3DPC wall and the ones with lower thermal conductivity perform better as normal solid wall, and 3D-HSC wall performs better than HSC solid wall, whereas LWFC solid wall performs better than 3D-LWFC wall. Suntharalingam et al. [7] studied the fire performance of 20 different 3DPC wall configurations using finite element models, specifically evaluating their response under standard fire conditions. The study’s results highlighted that 3D-printed concrete (3DPC) non-load-bearing cavity walls show considerable resistance when exposed to standard fire loads. Notably, there was a noteworthy enhancement in fire performance by increasing the thickness of the walls arranged in parallel rows. These non-load-bearing cavity walls exhibited impressive resistance for a duration of four hours under standard fire load conditions.
2 Modeling
The dimension considered for the 3D-printed models has been provided in Table 1.
3 Finite Element Analysis
The finite element modeling for multiple 3D-printed concrete walls with and without openings was modeled using ABAQUS. The software was used to analyze the loaded 3D-printed concrete walls at high temperature, and the displacement and stresses were also studied by exposing the model to fire conditions.
3.1 Properties and Specimen Details
The dimensions of the 3DPC wall are 1000 mm length, 500 mm width, and 100 mm depth. The 3D-printed concrete wall has 50 layers with each layer having the 10 mm layer thickness. Properties such as conductivity, specific heat, Young’s modulus, and mass density are given in Table 1 as per the EN 1992-1-2 [5] which provides the thermal properties at elevated temperature. The properties obtained were slightly modified as per Suntharalingam [7]. Totally, 16 sets of 3DPC walls are there with square, circular, rectangular, triangular, and hexagonal openings. The material and thermal properties are provided in Table 2, and the specimen details are provided in Table 3.
The top surface of the various types of 3D-printed concrete wall models is shown in Figs. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 and 16.
3.2 Modeling and Meshing
The part was created and then assembled using the method of layering with 50 layers and layer thickness of 10 mm. Tie interaction and film coefficient were provided using EN ISO 6946 [8]. The model was analyzed for the time period of 2 h or 7200 s. Pressure was created on the top surface of the wall, and the surface heat flux was applied on the front surface of the wall as per ISO-834-10:2014 [9]. The bottom side of the 3DPC wall is fixed. In the fixed boundary condition, the displacement and the rotation in the x, y, and z directions (U1, U2, U3, UR1, UR2, UR3) are zero. The film coefficient was applied as per EN ISO 6946:2017 [8]. Here, coupled temperature–displacement analysis has been carried out in the transient state. By implementing the convergence study, optimum mesh size of 25 mm was determined and applied to all the models as shown in Fig. 2. Eight-node brick element has been used as it can yield more precise outcomes and handle irregular shapes with minimal compromise in accuracy (Figs. 17 and 18).
4 Results and Discussion
4.1 Results
The results of the finite element study on loaded 3D-printed concrete wall are provided below, and multiple graphs are were modeled to study the behavior of the 3DPC wall under pressure and surface heat flux. The results obtained are provided in Table 4.
4.2 Discussion
The time versus temperature curve for 3DPC concrete wall is given in Fig. 19. This graph showcases the plotted values against time (minutes) and temperature (°C), following the ISO-834 [9] standard. The surface temperature and core temperature are plotted with respect to time (Fig. 20).
The temperature vs. displacement graph has been plotted based on the point at which the failure occurs, in order to understand the effect of the pressure and surface heat flux applied over the 3D-printed concrete walls (Fig. 21).
The temperature variance graph has been plotted to understand the behavior of various 3D-printed concrete walls with and without the openings when exposed to high temperatures (Fig. 22).
The displacement graph has been plotted to understand the displacement occurring on various 3D-printed concrete walls (Fig. 23).
The shear stress graph has been plotted to understand the shear stress occurring on various 3D-printed concrete walls (Fig. 24).
The time period graph has been plotted to understand the time required by various 3D-printed concrete walls with and without the openings to fail due to the pressure and surface heat flux applied over it.
5 Conclusion
With the results obtained from performing finite element research on the study of three-dimensionally printed concrete walls under high temperatures, a comprehensive analysis was conducted on 16 wall models, including variations with and without openings of different shapes. Based on these analyses, the following conclusions can be drawn:
-
It can be observed that the maximum displacement of 6.20 mm was found in the 3DPC solid wall which has no openings. When the openings are provided in the wall, a maximum displacement of 5.78 mm can be observed in the BS1 wall which has been provided with five square-shaped openings.
-
It can be observed that the minimum displacement of 4.33 mm was found in the BHT1 wall with 28 hexagonal and triangular openings.
-
It can be observed that the 3DPC solid wall which has no openings can withstand the highest temperature of 922 °C when compared to the other walls. When the openings are provided in the wall, it can be observed in the BR1 with five rectangular openings which can withstand the highest temperature of 909 °C when compared to the other walls with openings.
-
It can be observed that the BT2 wall with ten triangular openings withstands the lowest temperature of 759 °C when compared to the other walls with openings.
-
It can be observed that the 3DPC solid wall displays the most shear stress of 1.80 N/mm2 along with the BT3 wall with ten mini-triangular openings.
-
It can be observed that the BR1 wall with five rectangular openings displays the lowest shear stress of 0.92 N/mm2 when compared to the other walls.
References
Paul S, van Zijl G, Tan MJ, Gibson I (2018) A review of 3D concrete printing systems and materials properties: current status and future research prospects. Rapid Prototyp J. 24:784–798. https://doi.org/10.1108/RPJ-09-2016-0154
Lyu F, Zhao D, Hou X, Sun L, Zhang Q (2021) Overview of the development of 3D-printing concrete: a review. Appl Sci 11:9822
Wolfs RJM, Bos FP, Salet TAM (2018) Early age mechanical behaviour of 3D printed concrete: numerical modelling and experimental testing. Cement Concr Res 106:103–116
Suntharalingam T, Gatheeshgar P, Upasiri I, Keerthan P, Nagaratnam B, Corradi M, Perera D (2021) Fire performance of innovative 3D printed concrete composite wall panels—a numerical study. Case Stud Constr Mater 15. https://doi.org/10.1016/j.cscm.2021.e00586
Eurocode 2: Design of concrete structures—Part 1–2: general rules—structural fire design (EN 1992-1-2)
Marais H, Christen H, Cho S, De Villiers W, van Zijl G (2021) Computational assessment of thermal performance of 3D printed concrete wall structures with cavities. J Build Eng 41:102431. https://doi.org/10.1016/j.jobe.2021.102431
Suntharalingam T, Gatheeshgar P, Upasiri I, Keerthan P, Nagaratnam B, Rajanayagam H, Navaratnam S (2021) Numerical study of fire and energy performance of innovative light-weight 3D printed concrete wall configurations in modular building system. Sustainability 13:21. https://doi.org/10.3390/su13042314
EN ISO 6946:2017. Building components and building elements—thermal resistance and thermal transmittance—calculation methods
ISO 834-10:2014 Fire resistance tests—elements of building construction—part 10: specific requirements to determine the contribution of applied fire protection materials to structural elements
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Vignesh, B., Parthasarathi, N. (2024). Analytical Study on 3D-Printed Concrete Wall with Different Wall Configurations When Exposed to High Temperature. In: Gencel, O., Balasubramanian, M., Palanisamy, T. (eds) Sustainable Innovations in Construction Management. ICC IDEA 2023. Lecture Notes in Civil Engineering, vol 388. Springer, Singapore. https://doi.org/10.1007/978-981-99-6233-4_46
Download citation
DOI: https://doi.org/10.1007/978-981-99-6233-4_46
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-99-6232-7
Online ISBN: 978-981-99-6233-4
eBook Packages: EngineeringEngineering (R0)