Abstract
In the present paper, a statistical limit analysis was carried out to estimate the bearing capacity of the surface strip and the circular base resting on dense sand under the loose sand layer. The analysis was accompanied by a lower and upper bound limit analysis in combination with finite elements and second-order conic programming (SOCP). In this approach, the Mohr–Coulomb yield criterion was used to model soil behavior. Assuming an associated flow rule, rigorous lower and upper bounds on ultimate bearing capacity are obtained with the use of this technique. Comparisons were made with the available solutions from the literature wherever applicable.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
Estimation of bearing capacity and settlement of the foundation has been a significant topic of interest since time immemorial. Although many research studies have been published in the literatures on layered soil media (Meyerhof 1974; Meyerhof and Hanna 1978; Hanna 1981, 1982, 1987; Georgiadis and Michalopoulos 1985; Oda and Win 1990; Michalowski and Shi 1995; Burd and Frydman 1997; Kenny and Andrawes 1997; Okamura et al. 1998; Shiau et al. 2003; Farah 2004; Kumar et al. 2007; Shoaei et al. 2012; Kumar and Chakraborty 2015), nevertheless, there are few experimental studies conducted by scientists in layered sand media (Meyerhof and Hanna 1978; Hanna 1981, 1982; Farah 2004; Kumar et al. 2007). Meyerhof and Hanna (1978) determined the ultimate bearing capacity of the strip and the circular footing under inclined load using the limit equilibrium method. The results of the theoretical analyses were compared with small-scale model tests. Hanna (1981, 1982) developed design charts for estimating the bearing capacity of the strip and circular footing placed on layered sand media. That is a dense sand layer on loose sand strata and a loose sand layer on dense sand. Farah (2004) derived expressions for strip footing resting on layered soil. According to Farah (2004), the bearing capacity depends on the shear strength parameter of the upper and lower layers, the thickness of the upper layer and the width of the base to the depth ratio. Kumar et al. (2007) determined the carrying capacity of the dense sand layer overlying the loose sand deposit with and without geogrid on dense sand layer.
It is clear from the available literature that research has been carried out to determine the bearing capacity of layered sand media employing laboratory tests or the use of traditional approaches involving several simplified assumptions. Hardly any computational studies are available to determine the ultimate bearing capacity of layered sand media. This paper is trying to fill the gap. In the present paper, the bearing capacity of the strip and circular footing resting on layered sand media, that is, dense on loose sand is estimated using the lower and upper bound finite element limit analysis in conjunction with the second-order conic programming (SOCP). The analyses were conducted by varying the thickness of the upper dense layer and the angle of the internal friction of the two layers. The results are presented in a dimensionless manner and the comparisons are made with the available literature.
1.1 Problem Definition
A rigid rough strip and a circular footing are placed over a dense sand layer underneath the loose sand layer for analysis, as shown in Fig. 1. H is the thickness of the top densified sand layer and B is the width/diameter of the base. It is intended to determine the ultimate bearing capacity of the base with variation in the frictional angle of the upper and lower layers and the thickness of the top dense layer. ϕ1, ϕ2, and γ1, γ2 are the friction angles and unit weight of the top and bottom sand layers, respectively. Bowles (1977) provided the relationship between unit weight (γ) and friction angle (ϕ). These values were considered for analysis. The values are presented in Table 1. The soil is assumed to be completely plastic, comply with the associated flow rule and the Mohr–Coulomb failure criterion.
Problem domain and mesh details
The selected problem domain with associated boundary conditions is shown in Fig. 1. l and d are the length and depth of the chosen problem domain, respectively. Considering the corresponding stress and velocity conditions for the lower and upper bound analysis, one-half of the chosen domain on the x–y plane was used for analysis. At the base, at the bottom horizontal and the right vertical boundary (BC and CD), τ ≤ |σn tanϕ| was applied.
No horizontal velocity (u) along the base and line of symmetry was allowed during the upper bound analysis. The horizontal (u) and the vertical velocity (v) are kept to zero for the selected horizontal and vertical boundary. Only uniform vertical velocities were imposed along the footing base. The problem domain was selected by performing several trials so that patterns of failure lie within the domain without touching the horizontal bottom and the vertical boundaries right. l and d values of 7B and 5B, respectively, are sufficient to satisfy the conditions. Adaptive meshes for footing with H/B = 0.25, 0.75 and 1.25 for ϕ1 = 42° and ϕ2 = 32° are shown in Fig. 2. The meshes are continuously updated based on the shear dissipation of the domain.
2 Methodology
The numerical lower and upper bound finite element limit analyses were carried out using the lower and upper bound formulations given by Makrodimopoulos and Martin (2006, 2007) and Krabbenhoft et al. (2007, 2008), respectively. For the lower bound analysis, three-noded triangular elements with nodal stress σx, σy, τxy were used to represent the problem of the plane strain and the nodal stress σr, σz, σɵ and τrz were used to represent the problem of the axisymmetrical strain. Statically admissible stress discontinuities have been introduced along with the interfaces of all triangular elements so that there will be a change in normal stress and shear stress at the nodes, but the stress remains continuous along the interface path. The main objective of the lower bound analysis is to maximize the collapse load. Six-noded triangular elements with horizontal and vertical velocity (u and v) were considered for the upper bound analysis. The interfaces have introduced kinematically admissible velocity discontinuities. The main objective of the upper bound analysis is to minimize the collapse. Lower and upper bound values of bearing capacity were obtained for dense on loose sand by varying the top (ϕ1) and bottom friction angle (ϕ2) and changes in the values of H/B. The results thus obtained are compared with the available literature, wherever applicable.
The methodology of the lower and upper bound analysis is explained in Sloan (1988), Sloan and Kleeman (1995), Lyamin (1999), Lyamin and Sloan (2002a, b), Krabbenhoft et al. (2007), Krabbenhoft et al. (2008), Makrodimopoulos and Martin (2006), (2007); Kumar and Chakraborty (2014) and Kumar and Mohapatra (2017). In the present study, numerical computations were carried out using the Optum G2 computer program.
3 Results and Comparison
After the determination of collapse load (Qu), the ultimate bearing capacity (qu) for circular and strip footing was determined following Eqs. 1 and 2.
Before presenting the results for two-layered sand, it was thought of validating the model and software used for the present studies with the literatures for homogeneous
3.1 Footings on Homogeneous Sand
The analysis was performed for strip and circular base resting on a homogeneous sand layer. The angle of internal friction of sand varied from 30° to 45°. The ultimate bearing capacity was related to bearing factor Nγ (Eq. 3). The Nγ values are shown in Figs. 3 and 4 for strip and circular footing, respectively, following Terzaghi’s equations as
The Nγ values presented in Figs. 3 and 4 show that the present analysis is quite comparable with those reported by Kumar and Khatri (2008, 2011) by using the lower bound limit analysis and linear optimization. Further, the Nγ values given by Martin (2005) by using the method of stress characteristics were found to lie between the lower and upper bound values of the present analysis.
3.2 Footings on Layered Sand
After carrying out the analysis for homogeneous cases, the analysis was carried out for layered sand media. The friction angle of the top dense layer varied from 42° to 46° and the bottom loose layer varied from 32° to 36°. The H/B ratio also varied until the bearing capacity became constant. The bearing capacity was expressed in terms of the efficiency factor, which is defined as the ratio of bearing capacity of the layered sand media to the ratio of bearing capacity of the homogeneous sand layer. The friction angle of the top dense sand is ϕ1 and bottom loose sand is ϕ2. The efficiency factor was calculated by considering the average of lower and upper bound bearing capacity values.
3.3 Variation of Efficiency Factor with H/B
The variation of efficiency factor with H/B for different values of ϕ1 and ϕ2 is shown in Figs. 5 and 6 for strip and circular footings, respectively. From these figures, it can be observed that due to the inclusion of dense sand layer the efficiency factor increases with an increase in H/B and later it becomes constant with certain H/B values. It was also noticed that for the same values of H/B, ϕ1 and ϕ2, the efficiency factor was found to be greater for circular footing in comparison to strip footing. For example, for H/B = 2, ϕ1 and ϕ2 = 42° and 32°, the efficiency factor for circular and strip footings was found to be 8.41 and 3.95, respectively. It was also observed that the efficiency factor increased with the increase in ϕ1 and decrease in ϕ2. From Figs. 5 and 6, it was also observed that the efficiency factor increases with H/B value. Further, the efficiency factor continues for a higher H/B value for strip footing compared to the circular footing. A similar observation was revealed by Meyerhof and Hanna (1978).
4 Comparisons
To compare the results of the present analysis with those available in the literature, the magnitude of bearing capacity was expressed in non-dimensional manner by dividing with (g1B). The analysis was carried out by considering ϕ1 = 47.7°, ϕ2 = 34°, γ1 = 16.33 KN/m3 and γ2 = 13.78 KN/m3. Table 2 shows a comparison of the present lower and upper bound results for strip footings with the corresponding experimental results of Hanna (1981) and Farah (2004). From Table 2 it can be noticed that the bearing capacity reported by Hanna (1981) and Farah (2004) was found to be either higher or close to the present results for H/B values up to 1. However, for values of H/B greater than 1, bearing capacity of the present analysis was found to be greater than those reported in the literature. Similar trends were also observed for circular footings. Table 3 shows the comparisons of the present analysis for circular footings with the corresponding experimental results of Hanna (1981).
5 Conclusions
The bearing capacity of the strip and circular base on dense sand, overlaid by loose sand strata, was numerically determined using lower and upper bound finite element limit analysis with conic optimization. The results are presented in terms of non-dimensional efficiency factors. The study concludes with the following conclusions:
-
1.
For a given friction angle of top dense layer and bottom loose layer, the efficiency factor increases with an increase in the thickness of the top dense layer.
-
2.
The increase in efficiency factor with the inclusion of a dense layer of specific thickness becomes more significant for a circular base than for a strip. That is to say, for the same thickness of the top dense layer, the circular base has more bearing capacity than the strip foot.
-
3.
The increase in efficiency factor with the inclusion of a dense layer of specific thickness becomes more significant for the circular base compared to the strip foot, that is, for the same thickness of the top dense layer circular footing has more bearing capacity than the strip footing.
The generated adaptive mesh shows the variation of the bearing capacity with the thickness of the top dense layer.
The results of the present study suggest that with the inclusion of a thin, dense layer just below the footing resting on layered sand strata, the bearing capacity can be improved.
References
Bowles JE (1977) Foundation analysis and design. McGraw-Hill, New York
Burd HJ, Frydman S (1997) Bearing capacity of plane-strain footings on layered soils. Can Geotech J 34(2):241–253
Farah CA (2004) Ultimate bearing capacity of shallow foundations on layered soils. MSc thesis, Civil and Environmental Engineering, Concordia Univ., Quebec
Georgiadis M, Michalopoulos A (1985) Bearing capacity of gravity bases on layered soil. J Geotech Eng https://doi.org/10.1061/(ASCE)0733-9410(1985)111:6(712), 712–729 (1985)
Hanna AM (1981) Foundations on strong sand overlying weak sand. J Geotech Engrg Div 107(7):915–927
Hanna AM (1982) Bearing capacity of foundations on a weak sand layer overlying a strong deposit. Can Geotech J 19(3):392–396
Hanna AM (1987) Finite element analysis of footings on layered soils. Math Modell 9(11):813–819
Kenny MJ, Andrawes KZ (1997) The bearing capacity of footings on a sand layer overlying soft clay. Geotechnique 47(2):339–346
Krabbenhøft K, Lyamin AV, Sloan SW (2007) Formulation and solution of some plasticity problems as conic programs. Int J Solids Struct 44(5):1533–1549
Krabbenhøft K, Lyamin AV, Sloan SW (2008) Three-dimensional Mohr-Coulomb limit analysis using semidefinite programming. Int J Numer Methods Eng 24(11):1107–1119
Kumar A, Ohri ML, Bansal RK (2007) Bearing capacity tests of strip footings on reinforced layered soil. Geotech Geol Eng 25(2):139–150
Kumar J, Chakraborty M (2014) Upper bound axisymmetric limit analysis using Mohr-Coulomb yield criterion, finite elements and linear optimization. J Eng Mech, https://doi.org/10.1061/(ASCE)EM.1943-7889.0000820, 06014012
Kumar J, Chakraborty M (2015) Bearing capacity of a circular foundation on layered sand–clay media. Soils Found 55(5):1058–1068
Kumar J, Khatri VN (2008) Effect of footing roughness on lower bound Nγ values. Int J Geomech, 176–187, https://doi.org/10.1061/(ASCE)1532-3641(2008)8:3(176)
Kumar J, Khatri VN (2011) Bearing capacity factors of circular foundations for a general c-ϕ soil using lower bound finite elements limit analysis. Int J Numer Anal Methods Geomech 35(3):393–405, Wiley
Kumar J, Mohapatra D (2017) Lower-bound finite elements limit analysis for Hoek-Brown materials using semidefinite programming. J Eng Mech, 04017077 https://doi.org/10.1061/(ASCE)EM.1943-7889.0001296
Lyamin AV (1999) Three-dimensional lower bound limit analysis using nonlinear programming. PhD thesis, Univ. of Newcastle, Callaghan, Australia
Lyamin AV, Sloan SW (2002a) Lower bound limit analysis using non-linear programming. Int J Numer Methods Eng 55(5):573–611
Lyamin AV, Sloan SW (2002b) Upper bound limit analysis using linear finite elements and non-linear programming. Int J Numer Anal Methods Geomech 26(2):181–216
Makrodimopoulos A, Martin CM (2006) Lower bound limit analysis of cohesive frictional materials using second-order cone programming. Int J Numer Methods Eng 66(4):604–634
Makrodimopoulos A, Martin CM (2007) “Upper bound limit analysis using simplex strain elements and second-order cone programming. Int J Numer Anal Methods Geomech 31(6):835–865
Martin CM (2005) Exact bearing capacity calculations using the method of characteristics. In: Proceedings 11th Conference of IACMAG, Vol 4, International Association for Computer Methods and Advances in Geomechanics, 441–450
Meyerhof GG (1974) Ultimate bearing capacity of footings on sand layer overlying clay. Can Geotech J 11(2):223–229
Meyerhof GG, Hanna AM (1978) Ultimate bearing capacity of foundations on layered soils under inclined load. Can Geotech J 15(4):565–572
Michalowski RL, Shi L (1995) Bearing capacity of footings over two-layer foundation soil. J Geotech Engrg, 421–428, https://doi.org/10.1061/(ASCE)0733-9410(1995)121:5(421)
Oda M, Win S (1990) Ultimate bearing-capacity tests on sand with clay layer. J Geotech Eng, 1902–1906
Okamura M, Takemura J, Kimura T (1998) Bearing capacity predictions of sand overlying clay based on limit equilibrium methods. Soils Found 38(1):181–194
Optum G2 [Computer software]. Optum Computational Engineering, Copenhagen, Denmark
Shiau JS, Lyamin AV, Sloan SW (2003) Bearing capacity of a sand layer on clay by finite element limit analysis. Can Geotech J 40(5):900–915
Shoaei MD, Alkarni A, Noorzaei J, Jaafar MS, Huat BBK (2012) Review of available approaches for ultimate bearing capacity of two-layered soils. J Civ Eng Manage 18(4):469–482
Sloan SW (1988) Lower bound limit analysis using finite elements and linear programming. Int J Numer Anal Methods Geomech 12(1):61–77
Sloan SW, Kleeman PW (1995) Upper bound limit analysis using discontinuous velocity fields. Comput Methods Appl Mech Eng 127(1):293–314
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Das, P.P., Khatri, V.N. (2020). Bearing Capacity Estimation of Shallow Foundations on Dense Sand Underlain by Loose Sand Strata Using Finite Elements Limit Analysis. In: Latha Gali, M., Raghuveer Rao, P. (eds) Construction in Geotechnical Engineering. Lecture Notes in Civil Engineering, vol 84. Springer, Singapore. https://doi.org/10.1007/978-981-15-6090-3_14
Download citation
DOI: https://doi.org/10.1007/978-981-15-6090-3_14
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-6089-7
Online ISBN: 978-981-15-6090-3
eBook Packages: EngineeringEngineering (R0)