Keywords

1 Introduction

Appearance properties of objects are one of the most challenges of nowadays industries, to keep a place in a diversified market full of competition. To this commitment of quality was also added the necessity of recycling, especially for the plastics industry. In a commercial production process, it is important to get rid of waste product. These are usually recycled to improve cost performance. However, this recycling process often brings unfavorable effects, e.g., an increase in appearance properties. To achieve this compromise between recycling and good esthetic of produces, studies on the effect of recycling on the appearance properties of polymers are needed. The effect of recycling on optical properties of polymer films has been few analyzed in the literature [1, 2] but no study has been done on the effect of recycling on the appearance properties of injected parts. Among other plastics, polypropylene (PP) is a commodity polymer product and used in large quantities for many applications. The main reasons for the success of PP are its quite good price/performance ratio, its excellent mechanical properties, and suitable optical characteristics [3]. The huge consumption of this polymer makes its recycling strategically very important for the environmental policy of industry [4]. On the other hand, appearance properties of polymer products are mostly determined by the processing parameters. A low cavity surface temperature makes the polymer melt freeze prematurely and consequently a frozen layer will be formed during filling process at the interface between the hot polymer melt and the cold mould cavity, which leads to a series of defects of the final moulded parts, such as flow mark [5, 6] weld mark [7, 8], swirl mark [9], roughness [10], low gloss [11], and low replication accuracy [12]. Zhang et al [13] showed that surface quality of plastic parts can be improved significantly by increasing mold cavity temperature. The gloss of both ABS/PMMA and ABS/PMMA/nano-CaCO3 gradually increase with the increase of mold cavity temperature. The process conditions had a strong influence on the gloss development and on the color of pigmented PP. A better replication of the mold texture can be achieved at a lower melt viscosity at higher shear rates and higher mold temperatures. This gives a higher gloss in smooth regions. The gloss had a significant effect on the color: all the factors that contributed to an increase in gloss showed concomitant effects of increasing the color coordinate b* and of decreasing the lightness L*. Studies were published showing that the processing parameters may affect the gloss of injection molded parts [14], the mold temperature commonly being considered the more important parameter to be controlled. It was clearly shown that the mold temperature is the more relevant parameter and that a clear interaction exists between that parameter and the holding pressure.

From a physical point of view, the two quantitative descriptors of appearance (gloss and color) are the consequences of complex psychophysical phenomena of visual perception related to a situation in which the light reflected from the surface of an opaque sample is either predominantly in the specular direction (gloss) or diffuse in all directions (color) [15]. The four variables that primarily affect the gloss are the surface topography (or texture) [16], the wavelength and angle of the incident light and the refractive index of the material [17], whereas the color depends on the illumination conditions, the observation angle, the optical characteristics of the material, the amount of the colorant present, the surface topography [18], and the gloss [19]. Work on polymeric surfaces has shown a decrease in gloss with increased roughness [20].

In this paper, we mainly focus on the effect of process conditions (material temperature, mold temperature, injection rate) and recycling on the gloss and colorimetric properties of polypropylene containing 2 wt% of pigment using statistical approach.

2 Materials and Techniques

2.1 Materials

The PP homopolymer SABIC® PP 575P produced by SABIC Europe was used in the experiments. SABIC® PP 575P is an homopolymer for injection molding. A masterbatch supplied by Clariant was used to obtain a gray-beige complexion. The masterbatch was characterized with EDS analysis by scanning electron microscopy. The analyze show the presence of: CaCO3 (calcium carbonate), TiO2 (titanium dioxide) and Sb2O3 (Antimony trioxide). Blending of PP with 2 wt% of pigments (masterbatch) was performed in the PEP “plastics technical center” with a co-rotating intermeshing twin-screw extruder (Clextral EVOLUM HT 32, diameter 32 mm, centerline distance 21 mm) with a length to diameter ratio L/D 44. The screw profile is made of conveying and kneading elements, also using opposite pitch to ensure melting, mixing, shearing, and a good dispersion of the components. The extrusion process was carried out with a screw rotation speed of 350 rpm, at a temperature of 210 °C and a throughput of 30 kg h−1. The colored pellets were also injection-molded to obtain samples for study.

2.2 Techniques

  • Material processing: The mold was supplied by CFO company specialized on “Manufacturing Design Tools”. The mold design was realized in C2MA to obtain samples of 100 mm × 100 mm with a thickness of 2 mm. the samples show two different faces, a polished mirror surface and a rough surface. All specimens were prepared on a Krauss Maffei KM50-180CX injection molding machine. The maximum clamping force is 50 tons. During experiment, corresponding to each set of experimental parameters, the 5 first injected samples are thrown away to ensure that the process was stable. PP was injected from zero to five steps of recycling. Samples are grinding with a Cutting Mill SM 300 to be reinjected.

  • Colorimetry: In a uniform color scale, the differences between points plotted in the color space correspond to visual differences between the colors plotted. The L* axis is the light-dark axis, and thus gives a measure of the relative brightness of the sample ranging from total black (L* = 0) to the white (L* = 100). The a* axis is the red-green axis (positive a* = red, negative a* = green), and the b* axis is the blue-yellow axis (positive b* = yellow, negative b* = blue) [21] (Fig. 1).

    Fig. 1
    figure 1

    (L*, a*, b*) representing color space

  • Brightness: In terms of physical measurements, especially in the industrial field, gloss of materials is considered only at specular angles using a glossmeter [22]. Glossmeters are built to afford three specular geometries (Fig. 2). The geometry is chosen based on the gloss level observed, selecting the 20 specular reflection for high-gloss materials and 85 for quasi-matt samples, while 60 is used for samples with an intermediate, satin-like appearance.

    Fig. 2
    figure 2

    Graphic representation of the difference in weight of the factors on total effect for the gloss response a R20, b R60, c R85

  • Statistical approach: In a purpose of understanding the effect of injection parameters and recycling on the appearance properties of polymers, several injection parameters and cycles numbers must be tested. One main limit for this kind of study is the large number of experiments that requires longtime and significant investments. The idea is to vary three injection parameters temperature of material (Tmaterial), Temperature of the mold (Tmold) and the injection rate for five injection cycles. The work material selected for the study was polypropylene because of its large use and the need to recycle it with the maintaining of good aspect properties.

The effects of four factors known to influence injection conditions, material temperature, mold temperature, injection flow and number of injection cycles were studied using a statistical approach. The three variables (materiel temperature, mold temperature and injection flow) were investigated at three industrial used levels (materiel temperature: 220, 240, 260 °C, mold temperature: 30, 50, 80 °C and injection flow: 10, 20, 40 cm3/s). The number of recycling varies from cycle 0 to cycle 4 at five levels. The complete matrix for screening was designed using D-optimal quadratic design. The experimental design was generated with the statistical software MODDE 10.1-Umetrics. A set of 45 experiments was carried out to determine the influence of injection parameters and recycling on the appearance properties of samples. The statistical software package Nemrodw® version 2007, LPRAI (Marseille, France) was used to analyze the experimental design.

The response approach involving a D-optimal quadratic design was adopted for studied the effect of injection parameters and recycling on the final response (colorimetric and gloss). In fact, A D-optimal quadratic design is a computer aided design which contains the best subset of all possible experiments. Depending on a selected criterion and a given number of design runs, the best design is created by a selection process.

Each variable (material temperature, mold temperature, injection rate) was studied at three different levels (1, 2, and 3). The four recycling cycles was studied with four levels (1, 2, 3, and 4). All variables were taken at a central coded value of zero. The set of levels of the variables is summarized in Table 1.

Table 1 D-optimal plan variables used in the area of interest (Design of Experiments—DOE)

Each variable was coded between −1 and 1 according to Eq. (1):

$$ X_{i} = 2\frac{{P_{i} - \frac{{P_{i\hbox{max} } + P_{i\hbox{min} } }}{2}}}{{P_{i\hbox{max} } - P_{i\hbox{min} } }} = 2\frac{{P_{i} - \overline{{P_{i} }} }}{{\Delta P_{i} }} $$
(1)

with Pi, the variable to be coded between Pimin and Pimax respectively corresponding to the minimum and maximum of the experimental variables. The use of reduced centered variables has the advantage of being able to generalize the theory of the experiments plans whatever the factors or the fields of studies retained.

The responses have been adapted in order to know the final evolution of the colorimetric and brightness parameters according to the quadratic D-optimal model described above and corresponding to Eq. (2).

The minimum and maximum range of variables investigated and the full experimental plan with respect to their actual and coded forms. The analysis of the data was carried out to obtain an empirical model defining the response Y (Eq 1), which is the value of colorimetric (L*, a*, b*) or gloss (R20, R60, R85).

$$ \begin{aligned} {\text{Y}} & = {\text{b}}_{0} + {\text{b}}_{{1{\text{A}}}} .{\text{X}}_{{1{\text{A}}}} + {\text{ b}}_{{1{\text{B}}}} .{\text{X}}_{{1{\text{B}}}} + {\text{ b}}_{{2{\text{A}}}} .{\text{X}}_{{2{\text{A}}}} + {\text{ b}}_{{2{\text{B}}}} .{\text{X}}_{{2{\text{B}}}} + {\text{ b}}_{{3{\text{A}}}} .{\text{X}}_{{3{\text{A}}}} \\ & \quad + {\text{ b}}_{{3{\text{B}}}} .{\text{X}}_{{3{\text{B}}}} + {\text{ b}}_{{4{\text{A}}}} .{\text{X}}_{{4{\text{A}}}} + {\text{ b}}_{{4{\text{B}}}} .{\text{X}}_{{4{\text{B}}}} + {\text{ b}}_{{ 4 {\text{C}}}} .{\text{X}}_{{ 4 {\text{C}}}} + {\text{ b}}_{{ 4 {\text{D}}}} .{\text{X}}_{{ 4 {\text{D}}}} \\ \end{aligned} $$
(2)

Yi was the responses in terms of colorimetry and brightness. This result was of three separate tests and reflect the colorimetry values L*, a*, b* and brightness respectively at angles R20, R60, and R85.

3 Results and Discussion

Results in terms of gloss and colorimetric responses are analyzed with the statistical software package Nemrodw-version 2007, LPRAI (Marseille, France) and shown respectively in Figs. 2 and 3. The reference is taken on the value of the highest level (black bar). The influence of the injection temperature (220, 240 and 260 °C), the mold temperature (30, 50 and 80 °C), the injection rate (10, 20 and 40 cm3/s) and the number of injection cycle (cycle 0 to cycle 5) on the gloss of different PP samples with smooth surface is shown in Fig. 2.

Fig. 3
figure 3

Graphic representation of the difference in weight of the factors on total effect for the colorimetric response a L*, b a*, c b*

Figure 3 shows the effect of varying injection parameters and number of cycles on gloss (R20, R60, and R85). It can be observed that the recycling number change the gloss properties by varying R20, R60 and R85. These variations are not in the same way because of recycling lead to a decrease in R20 and an increase in R60 and R85. The effect of material temperature is observed only for R20 (Fig. 2a) for which the increase in material temperature lead to a decrease in R20. The modification of the mold temperature leads to variations in R20 and R60. The increase in mold temperature leads to an increase in R20 and R60. The interaction between the effect of material temperature and mold temperature lead to the increase of R20 at 80 °C of mold temperature. The injection rate does not significantly affect the gloss properties. In general, the number of injection cycles and the mold temperature has the greatest effect on the gloss level. For colorimetric response (Fig. 3) we have the same important effect of the recycling and the material temperature on (L*, a*, b*) that increases with increasing the number of cycles and the material temperature. The effect of mold temperature and injection rate is opposite and leads to a decrease in (L*, a*, b*).

We can note that colorimetric and a gloss property depends on changes in injection conditions and number of recycling cycles. The recycling and material temperature have the most important effect on colorimetric. The variations of gloss are obtained by changing the number of cycles, the material temperature and the mold temperature. Table 2 illustrate the pareto effect of all parameters. So, we notice that the numbers in bold highlighted the most important effect on gloss measurements. The studies of the appearance properties of the injection molded samples revealed that changes in injection parameters and number of cycles had a significant influence on colorimetric and gloss. Generally, appearance properties are related to the surface roughness. The differences in optical and appearance properties between samples were presumed to arise from the variation in the surface topography in according to the literature.

Table 2 The effect of injection parameters and number of cycles on the colorimetric and specular gloss measurements (Pareto individual effect from response analyses with Nemrodw)

4 Conclusion

The optical properties of recycled parts can be maintained during numerous internal recycling. The variations of properties are in the same range that is observed by changing processing parameters. The recycling and the material temperature are the most important factors changing the colorimetric properties of the material. The mold temperature affects only the gloss and there is no change in properties by varying the injecting flow. Also, aspect properties of recycled parts can be maintained during numerous internal recycling up to three cycles.