Abstract
Capillary electrophoresis–mass spectrometry (CE-MS) employing a sheathless porous tip interface has become a strong analytical tool for the efficient profiling of highly polar and charged metabolites in volume/material-restricted biological samples. As more and more metabolomics studies are (intrinsically) dealing with low numbers of mammalian cells, it would be important to use an additional performance metric to effectively evaluate the sampling and sample preparation procedure, in particular quenching. An established parameter to assess the sampling and sample preparation quality when working with cell cultures is the adenylate energy charge (AEC), which represents an index of the energy state of a cell. In this protocol, a CE-MS strategy is proposed for the reliable determination of the adenylate energy charge (AEC) in metabolomics studies dealing with low numbers of mammalian cells.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Ataullakhanov FI, Vitvitsky VM (2002) What determines the intracellular ATP concentration. Biosci Rep 22(5–6):501–511. https://doi.org/10.1023/a:1022069718709
Atkinson DE (1968) The energy charge of the adenylate pool as a regulatory parameter. Interaction with feedback modifiers. Biochemistry 7(11):4030–4034. https://doi.org/10.1021/bi00851a033
Tredwell GD, Edwards-Jones B, Leak DJ, Bundy JG (2011) The development of metabolomic sampling procedures for Pichia pastoris, and baseline metabolome data. PLoS One 6(1):e16286. https://doi.org/10.1371/journal.pone.0016286
Meyer H, Weidmann H, Lalk M (2013) Methodological approaches to help unravel the intracellular metabolome of Bacillus subtilis. Microb Cell Factories 12:69. https://doi.org/10.1186/1475-2859-12-69
Fu X, Deja S, Kucejova B, Duarte JAG, McDonald JG, Burgess SC (2019) Targeted determination of tissue energy status by LC-MS/MS. Anal Chem 91(9):5881–5887. https://doi.org/10.1021/acs.analchem.9b00217
Zhang W, Guled F, Hankemeier T, Ramautar R (2020) Profiling nucleotides in low numbers of mammalian cells by sheathless CE-MS in positive ion mode: circumventing corona discharge. Electrophoresis 41(5–6):360–369
Zhang W, Hankemeier T, Ramautar R (2019) Capillary electrophoresis-mass spectrometry for metabolic profiling of biomass-limited samples. Methods Mol Biol 1972:165–172. https://doi.org/10.1007/978-1-4939-9213-3_11
Zhang W, Gulersonmez MC, Hankemeier T, Ramautar R (2016) Sheathless capillary electrophoresis-mass spectrometry for metabolic profiling of biological samples. J Vis Exp 116:10.3791/54535
Acknowledgments
Dr. Rawi Ramautar would like to acknowledge the financial support of the Vidi grant scheme of the Netherlands Organization for Scientific Research (NOW Vidi 723.016.003).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 Springer Science+Business Media, LLC, part of Springer Nature
About this protocol
Cite this protocol
Zhang, W., Ramautar, R. (2022). Assessing the Energy Status of Low Numbers of Mammalian Cells by Capillary Electrophoresis–Mass Spectrometry. In: Neusüß, C., Jooß, K. (eds) Capillary Electrophoresis-Mass Spectrometry . Methods in Molecular Biology, vol 2531. Humana, New York, NY. https://doi.org/10.1007/978-1-0716-2493-7_13
Download citation
DOI: https://doi.org/10.1007/978-1-0716-2493-7_13
Published:
Publisher Name: Humana, New York, NY
Print ISBN: 978-1-0716-2492-0
Online ISBN: 978-1-0716-2493-7
eBook Packages: Springer Protocols