Skip to main content

Measurements of Indoor Air Quality

Science and Applications

  • Reference work entry
  • First Online:
Handbook of Metrology and Applications
  • 1189 Accesses

Abstract

Air quality in indoor environments is defined as the eminence of air in and nearby the house that directly affects human health. In the last few decades, the international scientific forum, environmental research, and political institutions have strived upon the improvement of the comfort, health, and well-being of building occupants. First and foremost, why is monitoring of IAQ necessary? This is due to indoor air pollution (IAP) which can have a serious and negative impact on both health and quality of life of inhabitants. In view of majority of time spend indoors by occupants, the subject of IAQ beholds a compelling approach for mitigation of air pollutant exposure specifically during current health crisis owing to COVID-19. Various research groups have used the latest equipment to manage the IAQ testing services that precisely test a range of parameters and concerned issues causing discomfort at the workplace. Thus, the aim of this chapter is to address the necessity and review the current knowledge of IAQ measurement in terms of different aspects, allied science, and its applications in order to show the strategy of translational research studies on IAQ. In addition, the different aspects of IAQ such as measurement techniques, characterization methods, source apportionment, and their effects on environment and human health are also parts of this chapter. Due to the rapidly changing technology, thermal ease parameters such as temperature, relative humidity (RH), and wind speed are known to play an important role in indoor air quality. This chapter is an attempt to discover how persons can live in surroundings of the environment with a good air quality and comfortable lifestyle.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 1,399.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 1,399.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  • Abdul-Wahab SA, En SCF, Elkamel A, Ahmadi L, Yetilmezsoy K (2015) A review of standards and guidelines set by international bodies for the parameters of indoor air quality. Atmos Pollut Res 6:751–767

    Article  Google Scholar 

  • Al-Hemoud A, Al-Awadi L, Al-Khayat A, Behbehani W (2018) Streamlining IAQ guidelines and investigating the effect of door opening/closing on concentrations of VOCs, formaldehyde and NO2 in office buildings. Build Environ 137:127–137

    Article  Google Scholar 

  • Arroyo P, Lozano J, Suárez JI (2018) Evolution of wireless sensor network for air quality measurements. Electronics 7(12):342

    Article  Google Scholar 

  • Arroyo P, Herrero JL, Suárez JI, Lozano J (2019) Wireless sensor network combined with cloud computing for air quality monitoring. Sensors 19:691

    Article  Google Scholar 

  • Avgelis A, Papadopoulos AM (2004) Indoor air quality guidelines and standards–A state of the art review. Int J Ventil 3:267–278

    Article  Google Scholar 

  • Axley JW (1988) Progress towards a general analytical method for predicting indoor air pollution in buildings: phase III report. Report Number NBSIR 88-3814, National Bureau of Standards, Gaithersburg

    Google Scholar 

  • Azimi P, Stephens B (2018) A framework for estimating the US mortality burden of fine particulate matter exposure attributable to indoor and outdoor microenvironments. J Expos Sci Environ Epidemiol 30:271–284

    Article  Google Scholar 

  • Badeke R, Matthias V, Grawe D (2021) Parameterizing the vertical downward dispersion of ship exhaust gas in the near field. Atmos Chem Phys 21:5935–5951

    Article  Google Scholar 

  • Bai L, Wang J, Ma X, Lu H (2018) Air pollution forecasts: an overview. Int J Environ Res Pub Health 15:780

    Article  Google Scholar 

  • Baklanov A, Zhang Y (2020) Advances in air quality modeling and forecasting. Global Transitions 2:261–270. https://doi.org/10.1016/j.glt.2020.11.001

    Article  Google Scholar 

  • Bag A, Lee N-E (2019) Gas sensing with heterostructures based on two-dimensional nanostructured materials: a review. J Mater Chem C 7:13367

    Article  Google Scholar 

  • Benammar M, Abdaoui A, Ahmad SHM, Touati F, Kadri A (2018) A modular IOT platform for real-time indoor air quality monitoring. Sensors 18:581

    Article  Google Scholar 

  • Blondeau P, Iordache V, Poupard O, Genin D, Allard F (2005) Relationship between outdoor and indoor air quality in eight French schools. Indoor Air 1980:2–12

    Article  Google Scholar 

  • Bluyssen PM (2009) Towards an integrative approach of improving indoor air quality. Build Environ 44:1980–1989

    Article  Google Scholar 

  • Borro M, Di Girolamo P, Gentile G, De Luca O, Preissner R, Marcolongo A et al (2020) Evidence-based considerations exploring relations between sars-cov-2 pandemic and air pollution: involvement of pm2.5-mediated up-regulation of the viral receptor ace-2. Int J Environ Res Pub Health 17:1–13

    Article  Google Scholar 

  • Brohus H (1997) Personal exposure to contaminant sources in ventilated rooms, Ph.D. dissertation, Aalborg University, Aalborg

    Google Scholar 

  • Challoner A, Gill L (2014) Indoor or outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2. J Build Environ 80:159–173

    Article  Google Scholar 

  • Carter EM, Katz LE, Speitel GE, Ramirez D (2011) Gas-phase formaldehyde adsorption isotherm studies on activated carbon: correlations of adsorption capacity to surface functional group density. Environ Sci Technol 45:6498–6503

    Article  Google Scholar 

  • Chen Q, Glicksman L (2003) System performance evaluation and design guidelines for displacement ventilation. ASHRAE, Atlanta

    Google Scholar 

  • Chen W, Gao Z, Zhang JS (2006) Laboratory testing of air cleaners for removing indoor contaminants. Proceedings of International Specialty Conference: Indoor Environmental Quality—Problems, Research and Solutions, Durham, July 17–19, 2006

    Google Scholar 

  • Chen K, Gao W, Emaminejad S, Kiriya D, Ota H, Nyein HYY, Takei K, Javey A (2016) Printed carbon nanotube electronics and sensor systems. Adv Meteorol 28:4397–4414

    Article  Google Scholar 

  • Chenari B, Carrilho JD, Silva MG (2016) Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: a review. Sustain Energy Rev 59:1426–1447

    Article  Google Scholar 

  • Chiesa G, Cesari S, Garcia M, Issa M, Li S (2019) Multisensor IOT platform for optimising IAQ levels in buildings through a smart ventilation system. Sustainability 11:5777

    Article  Google Scholar 

  • Cheng Y, Li X, Li Z, Jiang S, Li Y, Jia J et al (2014) Air Cloud: a cloud-based air quality monitoring system for everyone. In: 12th ACM conference on embedded network sensor systems, pp 251–214

    Chapter  Google Scholar 

  • Chojer H, Branco PTBS, Martins FG et al (2020) Development of low-cost indoor air quality monitoring devices: recent advancements. Sci Total Environ 727:138385

    Article  Google Scholar 

  • Cole MA, Ozgen C, Strobl E (2020) Air pollution exposure and COVID-19. Discussion paper series. IZA DP No. 13367:31

    Google Scholar 

  • Dai H, Zhao B (2020) Association of the infection probability of COVID-19 with ventilation rates in confined spaces. Build Simulation. https://doi.org/10.1007/s12273-020-0703-5

  • Dubey S, Rohra H, Taneja A (2021) Assessing effectiveness of air purifiers (HEPA) for controlling indoor particulate pollution. Heliyon 7(9):07976

    Article  Google Scholar 

  • Dygert RK, Dang TQ (2012) Experimental validation of local exhaust strategies for improved IAQ in aircraft cabins. Build Environ 47:76–88

    Article  Google Scholar 

  • European Environment Agency (2019) EEA Report No 10/2019. Copenhagen. https://doi.org/10.1016/S0306-3747(19)30103-4

  • Fanger PO (2006) What is IAQ? Indoor Air 16(5):328–334

    Article  Google Scholar 

  • Fanti G, Borghi F, Spinazzè A et al (2021) Features and practicability of the next- generation sensors and monitors for exposure assessment to airborne pollutants: a systematic review. Sensors 21:4513

    Article  Google Scholar 

  • Fishbain B, Lerner U, Castell N et al (2017) An evaluation tool kit of air quality micro643 sensing units. Sci Total Environ 575:639–648

    Article  Google Scholar 

  • Forouzanfar LT, Afshin MH, Alexander A, Anderson HR, Bhutta ZA, Biryukov S et al (2015) Global, regional, and national comparative risk assessment of 79 behavioural, environmental and occupational, and metabolic risks or clusters of risks, 1990–2015: a systematic analysis for the global burden of disease study 2015. The Lancet 388:1659–1724

    Article  Google Scholar 

  • Franklin PJ (2007) Indoor air quality and respiratory health of children. Paediatric Resp Rev 8:281–286

    Article  Google Scholar 

  • Freund MS, Lewis NS (1995) A chemically diverse conducting polymer-based “electronic nose”. Proc Natl Acad Sci USA 92:2652–2656

    Article  Google Scholar 

  • Furtaw EJ, Pandian MD, Behar JV (1994) An indoor personal air exposure model enhancement to account for proximity to emission sources. Presented at ISEE/ISEA Joint Conference: Research Triangle Park, 1994

    Google Scholar 

  • Gorai AK, Tuluri F, Tchounwou PB (2014) A GIS based approach for assessing the association between air pollution and asthma in New York state, USA. Int J Environ Res Pub Health 11:4845–4869

    Article  Google Scholar 

  • Goyal R, Khare M (2011) Indoor air quality modeling for PM10, PM2.5 and PM1.0 in naturally ventilated classrooms of an urban Indian school building. J Environ Mon Assess 176(1–4):501–516

    Article  Google Scholar 

  • Gramotnev G, Ristovski Z (2004) Experimental investigation of ultra-fine particle size distribution near a busy road. Atmos Environ 38:1767–1776

    Article  Google Scholar 

  • Graudenz GS, Oliveira CH, Tribess A, Mendes C, Latorre MRDO, Kalil J (2005) Association of air-conditioning with respiratory symptoms in office workers in tropical climate. Indoor Air 15:62–66

    Article  Google Scholar 

  • Guo P, Yokoyama K, Piao F, Sakai K, Khalequzzaman M, Kamijima M, Nakajima T, Kitamura F (2013) Sick building syndrome by indoor air pollution in Dalian, China. Int J Environ Res Pub Health 10:1489–1504

    Article  Google Scholar 

  • Habil M, Massey DD, Taneja A (2013) Exposure of children studying in schools of India to PM levels and metal contamination: sources and their identification. Air Qual Atmos Health 6(3):575–587

    Article  Google Scholar 

  • Haghighat F, Lee C-S, Pant B, Bolourani G, Lakdawala N, Bastani A (2008) Evaluation of various activated carbons for air cleaning–Towards design of immune and sustainable buildings. Atmos Environ 42:8176–8184

    Article  Google Scholar 

  • Han Y, Li X, Zhu T et al (2016) Characteristics and relationships between indoor and outdoor PM2.5 in Beijing: a residential apartment case study. Aerosol Air Qual Res 16:2386–2395

    Article  Google Scholar 

  • Hayes SR (1989) Estimating the effect of being indoors on total personal exposure to outdoor air pollution. J Air Poll Control Assoc 39(11):1453–1461

    Google Scholar 

  • Hayes SR (1991) Use of an indoor air quality model (IAQM) to estimate indoor ozone levels. J Air Waste Manage Assoc 41(2):161–170

    Article  Google Scholar 

  • He J, Xue W, Yan L, Shi X, Wang Y, Lei Y, Zhang Y (2022) Multi-dimensional sources apportionment of PM2.5 in Zhongyuan urban agglomeration based on the CAMx mode. Aerosol Air Qual Res 22:210254

    Article  Google Scholar 

  • Hesterberg TW, Bunn WB, McClellan RO, Hamade AK, Long CM, Valberg PA (2009) Critical review of the human data on short-term nitrogen dioxide (NO2) exposures: evidence for NO2 NO-effect levels. Critical Rev Toxicol 39:743–781

    Article  Google Scholar 

  • Höfner S, Andreas S (2021) Air quality measurements and education: improving environmental awareness of high school students. Front Sens 1. https://doi.org/10.3389/fsens.2021.657920

  • Howard J, Murashov V, Cauda E et al (2022) Advanced sensor technologies and the future of work. Am J Indus Med 65:3–11

    Article  Google Scholar 

  • Huang Y, Ho SSH, Lu Y, Niu R, Xu L, Cao J, Lee S (2016) Removal of indoor volatile organic compounds via photocatalytic oxidation: a short review and prospect. Molecules 21:56

    Article  Google Scholar 

  • Idrees Z, Zou Z, Zheng LR (2018) Edge computing based IoT architecture for low cost air pollution monitoring systems: a comprehensive system analysis, design considerations & development. Sens Basel 18:3021

    Article  Google Scholar 

  • Jan R, Roy R, Yadav S, Satsangi PG (2017) Exposure assessment of children to particulate matter and gaseous species in school environments of Pune, India. Build Environ 111:207–217

    Article  Google Scholar 

  • Jo J, Jo B, Kim J, Kim S, Han W (2020) Development of an IoT-based indoor air quality monitoring platform. J Sens

    Google Scholar 

  • Joshi SM (2008) The sick building syndrome. Ind J Occup Environ Med 12:61–64

    Article  Google Scholar 

  • Kang J, Hwang KI (2016) A comprehensive real-time indoor air-quality level indicator. Sustain-Basel 8:881

    Article  Google Scholar 

  • Kang K, Kim T, Kim H (2021) Effect of indoor and outdoor sources on indoor particle concentrations in South Korean residential buildings. J Hazard Mat 416:125852

    Google Scholar 

  • Kang I, McCreery A, Azimi P et al (2022) Indoor air quality impacts of residential mechanical ventilation system retrofits in existing homes in Chicago, IL. Sci Total Environ 804:150129

    Article  Google Scholar 

  • Kim B-Y, Ahn JH, Yoon J-W, Lee C-S, Kang YC, Abdel-Hady F, Wazzan AA, Lee J-H (2016) Highly selective xylene sensor based on nio/nimoo4 nanocomposite hierarchical spheres for indoor air monitoring. ACS Appl Mater Interfaces 8:34603–34611

    Article  Google Scholar 

  • Koontz MD, Natarajan S, Nagda NL, Nagda SN (1999) Initial surveys on depressurization-induced backdrafting and spillage: volume I – Washington, DC, and Omaha, NE. Report No. GRI-99/0186. Gas Research Institute, Chicago

    Google Scholar 

  • Koontz MD, Nagda NL (1991) A multichamber model for assessing inhalation exposure. Indoor Air 1(4):593–605

    Article  Google Scholar 

  • Kraakman NJR, González-Martín J, Pérez C, Lebrero R, Muñoz R (2021) Recent advances in biological systems for improving indoor air quality. Reviews in Environ Sci Bio/Technology 20(2):363–387

    Google Scholar 

  • Kreiss K (1989) The epidemiology of building-related complaints and illness. Occup Med 4:575–592

    Google Scholar 

  • Kumar P, Martani C, Morawska L et al (2016a) Indoor air quality and energy management through real-time sensing in commercial buildings. Energy Build 111:145–153

    Article  Google Scholar 

  • Kumar P, Skouloudis AN, Bell M et al (2016b) Real-time sensors for indoor air monitoring and challenges ahead in deploying them to urban buildings. Sci Total Environ 560–561:150–159

    Article  Google Scholar 

  • Lee SC (1997) Comparison of indoor and outdoor air quality at two staff quarters in Hongkong. J Environ Int 23(97):791–797

    Article  Google Scholar 

  • Lewis AC, Lee JD, Edwards PM, Shaw MD, Evans MJ, Moller SJ, Smith KR, Buckley JW, Ellis M, Gillot SR et al (2016) Evaluating the performance of low cost chemical sensors for air pollution research. Faraday Discuss 189:85–103

    Article  Google Scholar 

  • Ligotski R, Sager U, Schneiderwind U, Asbach C, Schmidt F (2019) Prediction of voc adsorption performance for estimation of service life of activated carbon based filter media for indoor air purification. Build Environ 149:146–156

    Article  Google Scholar 

  • Lin LY, Chuang HC, Liu IJ, Chen HW, Chuang KJ (2013) Reducing indoor air pollution by air conditioning is associated with improvements in cardiovascular health among the general population. Sci Total Environ 463–464:176–181

    Article  Google Scholar 

  • Liu D, Zhang Q, Jiang J, Chen DR (2017) Performance calibration of low-cost and portable particular matter (PM) sensors. J Aerosol Sci 112:1–10

    Article  Google Scholar 

  • Liu Z, Ye W, Little JC (2013) Predicting emissions of volatile and semivolatile organic compounds from building materials: a review. Build Environ 64:7–25

    Article  Google Scholar 

  • Massey D, Kulshrestha A, Masih J, Taneja ABEJ (2012) Seasonal trends of PM10, PM5.0, PM2.5 & PM1.0 in indoor and outdoor environments of residential homes located in North-Central India. J Build Environ 47:223–231

    Article  Google Scholar 

  • Mead MI, Popoola OAM, Stewart GB, Landshoff P, Calleja M, Hayes M, Baldovi JJ, McLeod MW, Hodgson TF, Dicks J et al (2013) The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks. Atmos Environ 70:186–203

    Article  Google Scholar 

  • Mandin C, Bonvallot N, Kirchner S, Keirsbulck M, Alary R, Cabanes PA, Dor F, Moullec YL, Mullot J-U, Peel AE et al (2009) Development of French indoor air quality guidelines. Clean Soil Air Water 37:494–499

    Article  Google Scholar 

  • Marmot AF, Eley J, Stafford M, Stansfeld SA, Warwick E, Marmot MG (2006) Building health: an epidemiological study of “sick building syndrome” in the Whitehall II study. Occup Environ Med 63(4):283–289

    Article  Google Scholar 

  • Milton B, Cleveland E, Bennet-Gates D (1995) Changing perceptions of nature, self, and others: a report on a park/school program. J Environ Educat 26:32–39

    Article  Google Scholar 

  • Miskell G, Salmond J, Williams DE (2017) Low-cost sensors and crowd-sourced data: observations of siting impacts on a network of air-quality instruments. Sci Total Environ 575:1119–1129

    Article  Google Scholar 

  • Missaoui R, Joumaa H, Ploix S, Bacha S (2014) Managing energy smart homes according to energy prices: analysis of a building energy management system. Energy Build 71:155–167

    Article  Google Scholar 

  • Moreno-Rangel A, Sharpe T, Musau F, McGill G (2018) Field evaluation of a low-cost indoor air quality monitor to quantify exposure to pollutants in residential environments. J Sens Sensor Syst 7:373–388

    Article  Google Scholar 

  • Morawska L, Thai PK, Liu X et al (2018) Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: how far have they gone? Environ Int 116:286–299

    Article  Google Scholar 

  • Nolte H, Backer V, Porsbjerg C (2001) Environmental factors as a cause for the increase in allergic disease. Annals Allergy Asthma Immunol 87:7–11

    Article  Google Scholar 

  • Oosthuizen DN, Motaung DE, Swart HC (2019) Selective detection of co at room temperature with cuo nanoplatelets sensor for indoor air quality monitoring manifested by crystallinity. Appl Surf Sci 466:545–553

    Article  Google Scholar 

  • Ott WR (1984) Exposure estimates based on computer generated activities patterns. J Toxicol Clin Toxicol 21:97–128

    Article  Google Scholar 

  • Patil K, Laad M, Kamble A, Laad S (2019) A consumer-based smart home with indoor air quality monitoring system. IETE J Res 65:758–770

    Article  Google Scholar 

  • Paetz A-G, Dütschke E, Fichtner W (2012) Smart homes as a means to sustainable energy consumption: a study of consumer perceptions. J Cons Pol 35:23–41

    Article  Google Scholar 

  • Persaud K, Dodd G (1982) Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose. Nature 299:352–355

    Article  Google Scholar 

  • Pipal AS, Kumar A, Jan R, Taneja A (2012) Role of plants in removing indoor air pollutants. In: Chemistry of phytopotentials: health, energy and environmental perspectives, pp 319–321

    Chapter  Google Scholar 

  • Pipal AS, Rohra H, Tiwari R, Taneja A (2021) Particle size distribution, morphometric study and mixing structure of accumulation and ultrafine aerosols emitted from indoor activities in different socioeconomic micro-environment. Atmos Poll Res 12(4):101–111

    Article  Google Scholar 

  • Pitarma R, Marques G, Caetano F (2016) Monitoring indoor air quality to improve occupational health. Springer, Basel

    Book  Google Scholar 

  • Pitarma R, Marques G, Ferreira BR (2017) Monitoring indoor air quality for enhanced occupational health. J Med Syst 41:23

    Article  Google Scholar 

  • Rai AC, Kumar P, Pilla F, Skouloudis AN, Di Sabatino S, Ratti C, Yasar A, Rickerby D (2017) End-user perspective of low-cost sensors for outdoor air pollution monitoring. Scie Total Environ 607:691–705

    Google Scholar 

  • Redlich CA, Sparer J, Cullen MR (1997) Sick-building syndrome. Lancet 349:1013–1016

    Article  Google Scholar 

  • Rohra H, Pipal AS, Tiwari R, Vats P, Masih M, Khare P, Taneja A (2020) Particle size dynamics and risk implication of atmospheric aerosols in South-Asian subcontinent. Chemosphere 249:126–140

    Article  Google Scholar 

  • Rohra H, Tiwari R, Khare P, Taneja A (2018) Indoor-outdoor association of PM and bounded elemental composition within coarse, quasi-accumulation and quasiultrafine ranges in residential areas of Northern India. Sci Total Environ 631–632:1389–1397

    Google Scholar 

  • Rohr AC, Weschler CJ, Koutrakis P, Spengler JD (2003) Generation and quantification of ultrafine particles through terpene/ozone reaction in a chamber setting. Aerosol Sci Technol 37:65–78

    Article  Google Scholar 

  • Saini J, Dutta M, Marques G (2020) A comprehensive review on indoor air quality monitoring systems for enhanced public health. Sustain Environ Res 30:6

    Article  Google Scholar 

  • Satsangi PG, Yadav S, Pipal AS, Kumbhar N (2014) Characteristics of trace metals in fine (PM2.5) and inhalable (PM10) particles and its health risk assessment along with in-silico approach in indoor environment of India. Atmos Environ 92:384–393

    Article  Google Scholar 

  • Schieweck A, Uhde E, Salthammer T, Salthammer LC, Morawska L, Mazaheri M, Kumar P (2018) Smart homes and the control of indoor air quality. Renew Sustain Energy Rev 94:705–718

    Article  Google Scholar 

  • Schneider P, Castell N, Vogt M, Dauge FR, Lahoz WA, Bartonova A (2017) Mapping urban air quality in near real-time using observations from low-cost sensors and model information. Environ Int 106:234–247

    Article  Google Scholar 

  • Spinelle L, Gerboles M, Villani MG, Aleixandre M, Bonavitacola F (2017) Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring Part B. Sensors Actuat B: Chem J 238:706–715

    Article  Google Scholar 

  • Scott SM, James D, Ali Z (2007) Data analysis for electronic nose systems. Microchimica Acta 156:183–207

    Article  Google Scholar 

  • Seltzer JM (1994) Building-related illnesses. J Allergy Clin Immunol 94:351–361

    Article  Google Scholar 

  • Sivasankari B, Prabha CA, Dharini S, Haripriya R (2017) IoT based indoor air pollution monitoring using raspberry pi. Int J Innovat Eng Technol 9:16–21

    Google Scholar 

  • Shrestha PM, Humphrey JL, Carlton EJ et al (2019) Impact of outdoor air pollution on indoor air quality in low-income homes during wildfire seasons. Int J Environ Res Public Health 16:3535

    Article  Google Scholar 

  • Soreanu G, Dixon M, Darlington A (2013) Botanical biofiltration of indoor gaseous pollutants–A mini review. Chem Eng J 229:585–594

    Article  Google Scholar 

  • Sparks LE, Tichenor BA, Chang J, Guo Z (1996) Gas Phase mass transfer model for predicting volatile organic compounds (VOC) emission rates from indoor pollutants sources. Indoor Air 6:31–40

    Article  Google Scholar 

  • Steinemann A, Wargocki P, Rismanchi B (2017) Ten questions concerning green buildings and indoor air quality. Build Environ 112:351–358

    Article  Google Scholar 

  • Sung WT, Hsiao SJ (2021) Building an indoor air quality monitoring system based on the architecture of the Internet of Things. EURASIP J Wireless Commun Network 1:1–41

    Google Scholar 

  • Szagun G, Mesenholl E, Jelen M (1994) Umweltbewusstseinbei Jugendlichen. Emotionale, hand lungs bezogene und ethische Aspekte. Lang Verlag, Frankfurt

    Google Scholar 

  • Tastan M, Gökozan H (2019) Real-time monitoring of indoor air quality with internet of things-based e-nose. Appl Sci 9:3435

    Article  Google Scholar 

  • Thomas S, Morawska L (2002) Size-selected particles in an urban atmosphere of Brisbane, Australia. Atmos Environ 36:4277–4288

    Article  Google Scholar 

  • Tofful L, Canepari S, Sargolini T et al (2021) Indoor air quality in a domestic environment: combined contribution of indoor and outdoor PM sources. Build Environ 202:108050

    Article  Google Scholar 

  • UN SDGs (2015), Sustainable Development Goals. United Nations, 2015. https://sustainabledevelopment.un.org/

  • USEPA (2020) Fundamentals of indoor air quality in buildings. Available online: https://www.epa.gov/indoorair-quality-iaq/fundamentals-indoor-air-quality-buildings. Accessed 28 Jan 2020

  • USEPA (1991) Sick building syndrome, vol 4. United States Environmental Protection Agency, Washington, DC

    Google Scholar 

  • Vardoulakis S, Giagloglou E, Steinle S, Davis A, Sleeuwenhoek A, Galea KS, Crawford JO (2020) Indoor exposure to selected air pollutants in the home environment: a systematic review. Int J Environ Res Pub health 17(23):8972

    Google Scholar 

  • WHO (2010) WHO guidelines for indoor air quality: selected pollutants. World Health Organization, Regional office in Europe, European Series, Copenhagen

    Google Scholar 

  • WHO, Coronavirus disease (COVID-19), Ventilation and Air Conditioning, World Heal. Organ. (2020). https://www.who.int/news-room/q-a-detail/coronavirus-disease-covid-19-ventilation-and-air-conditioning. Accessed 3 Dec 2020

  • Wainman T, Zhang JF, Weschler CJ, Lioy PJ (2000) Ozone and limonene in indoor air: a source of submicron particle exposure. Environ Health Perspect 108:1139–1145

    Article  Google Scholar 

  • Wang Z, Bai Z, Yu H, Zhang J, Zhu T (2004) Regulatory standards related to building energy conservation and indoor-air-quality during rapid urbanization in China. Energy Build 36:1299–1308

    Article  Google Scholar 

  • Wu YC, Shiledar A, Li YC, Wong J, Feng S, Chen X et al (2017) Air quality monitoring using mobile microscopy and machine learning. Light Sci 6:17046

    Article  Google Scholar 

  • Yang X, Chen Q, Zhang JS, An Y, Zeng J, Shaw CY (2001) A mass transfer model for simulating VOC sorption on building materials. Atmos Environ 35:1291–1299

    Article  Google Scholar 

  • Yu BF, Hu ZB, Liu M, Yang HL, Kong QX, Liu YH (2009) Review of research on air conditioning systems and indoor air quality control for human health. Int J Refrigeration 32:3–20

    Article  Google Scholar 

  • Yu TC, Lin CC (2015) An intelligent wireless sensing and control system to improve indoor air quality: monitoring, prediction, and preaction. Int J Distribut Sensor Networks 2015:140978

    Article  Google Scholar 

  • Zampolli S, Elmi I, Ahmed F, Passini M, Cardinali GC, Nicoletti S et al (2004) An electronic nose based on solid state sensor arrays for low-cost indoor air quality monitoring applications. Sensor Actuators B: Chem J 101:39–46

    Article  Google Scholar 

  • Zhang Y, Bocquet M, Mallet V, Seigneur C, Baklanov A (2012) Real-time air quality forecasting, part I: history, techniques, and current status. Atmos Environ 60:632–655

    Article  Google Scholar 

  • Zhang X, Cai H, Hu J, Lian J, Gu J, Zhang S, Yang Y (2020) Epidemiological, clinical characteristics of cases of SARS-CoV-2 infection with abnormal imaging findings. Int J Infectious Diseases 94:81–87

    Google Scholar 

  • Zang R, Castro MFG, McCune BT, Zeng Q, Rothlauf PW, Sonnek NM, Ding S (2020) TMPRSS2 and TMPRSS4 promote SARS-CoV-2 infection of human small intestinal enterocytes. Science Immunology 5(47):eabc3582

    Google Scholar 

  • Zhang J (2020) Integrating IAQ control strategies to reduce the risk of asymptomatic SARS CoV-2 infections in classrooms and open plan offices. Sci Technol Built Environ 26(8):1013–1018

    Google Scholar 

  • Zhao M, Liao L, Xiao W, Yu X, Wang H, Wang Q, Lin YL, Kilinc-Balci FS, Price A, Chu L et al (2020) Household materials selection for homemade cloth faces coverings and their filtration efficiency enhancement with triboelectric charging. Nano Letters 20(7):5544–5552

    Article  Google Scholar 

  • Zhao P, Siegel JA, Corsi RL (2007) Ozone removal by HVAC filters. Atmos Environ 41:3151–3160

    Article  Google Scholar 

  • Zheng T, Bergin MH, Johnson KK, Tripathi SN, Shirodkar S, Landis MS, Sutaria R, Carlson DE (2018) Field evaluation of low-cost particulate matter sensors in high-and low-concentration environments. Atmos Meas Tech 11:4823–4846

    Article  Google Scholar 

  • Zhou B, Li W, Chan KW, Cao Y, Kuang Y, Liu X, Wang X (2016) Smart home energy management systems: concept, configurations, and scheduling strategies. Renew Sustain Energy Rev 61:30–40

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Section Editor information

Rights and permissions

Reprints and permissions

Copyright information

© 2023 Springer Nature Singapore Pte Ltd.

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Pipal, A.S., Taneja, A. (2023). Measurements of Indoor Air Quality. In: Aswal, D.K., Yadav, S., Takatsuji, T., Rachakonda, P., Kumar, H. (eds) Handbook of Metrology and Applications. Springer, Singapore. https://doi.org/10.1007/978-981-99-2074-7_90

Download citation

Publish with us

Policies and ethics