Abstract
Nonspecific staining in ELISpot assay is a major obstacle in accurate quantification of experimental data. The appearance of nonspecific spots may be caused by different factors including cell- and immunoassay-related issues. In our study, we have shown that nonspecific spots can result from either cells or their debris sticking to the membranes in ELISpot plates, as well as by impurities in wash buffers and precipitation of aggregated detection antibodies. Although there is a growing interest in using Fluorospot assays allowing for simultaneous detection of multiple cell-secreted proteins, it appears that these fluorescence assays are more susceptible to developing nonspecific profiles resembling specific spots. In this chapter, we outline necessary ELISpot controls that need to be employed to tell the difference between bona fide spots vs. stained artifacts.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Sedgwick JD, Holt PG (1983) A solid-phase immunoenzymatic technique for the enumeration of specific antibody-secreting cells. J Immunol Methods 57(1–3):301–309
Czerkinsky CC, Nilsson LA, Nygren H et al (1983) A solid-phase enzyme-linked immunospot (ELISPOT) assay for enumeration of specific antibody-secreting cells. J Immunol Methods 65(1–2):109–121
Kalyuzhny AE (2005) Chemistry and biology of the ELISPOT assay. Methods Mol Biol 302:15–31
Kalyuzhny AE (2009) ELISPOT assay on membrane microplates. Methods Mol Biol 536:355–365
Czerkinsky C, Moldoveanu Z, Mestecky J, Nilsson LA, Ouchterlony O (1988) A novel two colour ELISPOT assay. I. Simultaneous detection of distinct types of antibody-secreting cells. J Immunol Methods 115(1):31–37
Kemeny DM (1997) Enzyme-linked immunoassays. In: Johnstone AP, Turner MW (eds) Immunochemistry 1. Oxford University Press, Oxford, pp 147–175
Kalyuzhny AE (2015) Membrane microplates for one- and two-color ELISPOT and FLUOROSPOT assays. Methods Mol Biol 1312:435–437
Gazagne A, Claret E, Wijdenes J et al (2003) A FluoroSpot assay to detect single T lymphocytes simultaneously producing multiple cytokines. J Immunol Methods 283(1–2):91–98
Gazagne A, Malkusch W, Vingert B et al (2005) FluoroSpot assay: methodological analysis. Methods Mol Biol 302:289–296
Rebhahn JA, Bishop C, Divekar AA et al (2008) Automated analysis of two- and three-color fluorescent ELISpot (FluoroSpot) assays for cytokine secretion. Comput Methods Prog Biomed 92(1):54–65
Ahlborg N, Axelsson B (2012) Dual- and triple-color FluoroSpot. Methods Mol Biol 792:77–85
Grant A, Palzer S, Hartnett C et al (2005) A cell-detachment solution can reduce background staining in the ELISPOT assay. Methods Mol Biol 302:87–94
Kalyuzhny A, Stark S (2001) A simple method to reduce the background and improve well-to-well reproducibility of staining in ELISPOT assays. J Immunol Methods 257:93–97
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Science+Business Media, LLC, part of Springer Nature
About this protocol
Cite this protocol
Hagen, J., Kalyuzhny, A.E. (2018). Essential Controls for ELISpot Assay. In: Kalyuzhny, A. (eds) Handbook of ELISPOT . Methods in Molecular Biology, vol 1808. Humana Press, New York, NY. https://doi.org/10.1007/978-1-4939-8567-8_3
Download citation
DOI: https://doi.org/10.1007/978-1-4939-8567-8_3
Published:
Publisher Name: Humana Press, New York, NY
Print ISBN: 978-1-4939-8566-1
Online ISBN: 978-1-4939-8567-8
eBook Packages: Springer Protocols