Abstract
Although there is a large body of previous studies on the cooling effect of green roofs on urban heat islands (UHIs), more empirical studies with an experimental setting measuring the role of green roof on mitigating urban heat should be considered. The purpose of this research is to determine the air temperature difference between green and bare roofs located on two buildings in the same local climate zone, and calculate the expected cooling effect extended from the green roof to the local climate. The study site consisted of an extensive green roof and a bare roof which were close to each other and were located in a highly built-up same area. During the three and a half clean days of testing in the middle of summer, air temperature data were collected from each roof using an air temperature logger and a local automatic weather station close to both roofs; these data were then converted to hourly data. The data were analyzed by the t test, ANOVA test, and a regression analysis to determine the heat mitigation effect of green roofs. As a result, the green roof’s air temperature showed much lower than the bare roof’s and followed the local station’s air temperature change during the day. At night the air temperature difference between the two roofs was only slight and the green roof’s air temperature kept lower than the local station’s. Thus, even extensive green roofs can reduce air temperature through their cooling effects from their vegetation and substrates against solar radiation. The established models reported that the green roof contributed to lowering air temperatures in a local climate zone, while the bare roof made such zones more heated. The findings of this study contribute to the existing literature by proving that green roofs can be expected to help cool down not only at the small scale with building units, but also at the broader scale of urban district area. The study also gives field-experimented values to be used as updated variables to local climate simulation models.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Urban heat islands (UHIs) have created a need for many heat-fighting countermeasures in urbanized areas. In cities, excessive heat in the air causes buildings to consume additional energy to keep their interiors cool and comfortable for residents (Zinzi and Agnoli 2012; Coutts et al. 2013; Jim 2014c). Meanwhile, waste heat originating from cooling machines and facilities including air-conditioning units increases the air temperature and subjects people outside of buildings to an increased risk of heat stress (Köhler et al. 2003; Harlan et al. 2006; Memon et al. 2008; Tan et al. 2010; Costanzo et al. 2016; Sun et al. 2016).
The modification of impervious urban areas into green spaces such as open spaces with trees, greenways, and parks has led to a reduction in UHIs, and the resulting cooling effects have been well documented (Loughner et al. 2012; Doick and Hutchings 2013; Kim et al. 2016; Park et al. 2017). Urban green spaces keep the air temperature cooler than in the surrounding areas, due to increased latent heat and shade (Kjelgren and Clark 1992; Akbari 2002; McPherson and Muchnick 2005; Napoli et al. 2016). Previous studies have shown that cities have reduced their UHIs by replacing impervious land cover with green spaces ranging in size from single patches of trees to entire neighborhoods (Kjelgren and Clark 1992; Saaroni et al. 2000; Shashua-Bar et al. 2011; Loughner et al. 2012).
Experimental UHI mitigation studies have primarily focused on urban green spaces on a street or at a ground level (Spronken-Smith and Oke 1998; Petralli et al. 2009; Hamada and Ohta 2010; Ren et al. 2013; Lehmann et al. 2014; Park et al. 2017). Meanwhile, existing research on green roofs' UHI reduction has experimented on the building scale; only a few simulation studies have considered the thermal benefits of green roofs on citywide or regional scales. Much work has used experiments to measure a green roof’s cooling effect on the inside of a building (Hamdi and Schayes 2008; Coutts et al. 2013; Jim 2014a, b; Karachaliou et al. 2016), as well as green roofs’ economic and visual benefits (Köhler et al. 2003; Yuen and Nyuk Hien 2005; Clark et al. 2008; Chen 2013; Jim 2014a; Santamouris 2014). Some previous studies have attempted to calculate green roofs’ cooling effects on UHIs throughout large and wide urban areas using computer-based simulation models (Köhler et al. 2003; Kumar and Kaushik 2005; Lazzarin et al. 2005; Rosenzweig et al. 2006; Castletona et al. 2010; Scherba et al. 2011; Zinzi and Agnoli 2012). However, even though some previous experimental studies on green roofs’ cooling influences on a local level has reported, most of the existing body of research has led to green roofs being considered for temperature countermeasures only when cooling on a building level; the result is that many Asian, North American, and European cities have limited green roof support programs (Blackhurst et al. 2010; Chen 2013; Doug et al. 2005; Dvorak and Volder 2010; Gaffin et al. 2009; Kleerekoper et al. 2012; Li et al. 2014; Middel et al. 2015; Mullen et al. 2013; Solecki et al. 2005; Vijayaraghavan 2016; Williams et al. 2010; Wong and Lau 2013).
Thus, the knowledge gap of those experimental studies on green roofs' UHI reduction lies on the facts that many field experiments have been limited to the building level and many simulation studies have taken unrealistic thermal conditions. Moreover, simulation studies can only offer a rough approximation of green roofs’ thermal performance in large modeled urban areas; field experiment studies on buildings have shown green roofs’ precise level of cooling performance, but the results from those studies have been restricted to the building scale. To experimentally evaluate green roofs’ cooling effects in a broader area, related studies should receive local UHI mitigation concepts such as the local climate zone, which is a theoretical climatic model to indicate identical urban settings that have similar boundary layer climates (Oke 1987; Stewart et al. 2014). In a same local climate zone, building roofs show the same microclimate when they share identical micro-climatic conditions, such as the same land use pattern, the same geographical location, and the same height of roofs (Stewart and Oke 2012; Stewart et al. 2014; Park et al. 2017). Thus, to compare cooling effects of bare roofs with those of green roofs having identical urban settings and field experimental methods in the same local climate zone lies on filling the knowledge gap.
Therefore, this study conducted the stationary survey on green and bare roofs, respectively, with identical settings and compared air temperature data from two roofs and weather stations. The purpose of this study was to determine air temperature difference among green and bare roofs and the weather station under the same local climate zone, find how large green roof’s cooling effects on a building and local level, and understand if the green roof’s cooling effect extended to the district within which the green roof was located.
Method
Study Site
The study site was in Gangnam-gu, Seoul, South Korea (37°31′2.68″N, 127°2′39.49″E). The site consisted of a green and a bare roof, and was located in the same highly built-up urban block within large areas of low-rise single houses and small high-rise residences (see Fig. 1). Two automatic weather stations are located nearby the project site (see Fig. 1). Except for the vegetation in the green roof, the two roofs had identical microclimate condition; the same roof height (20 m), the same geographical location (in a 48.2 m Euclidean distance away from each other) (see Fig. 1). The green roof was flat and bounded by parapet walls with their height of 1.2 m (see Fig. 1). The two roofs had tall residence buildings (60 m) on their west and south side. The size of the green roof was 2630.09 m2 and the roof consisted of an outdoor facilities area (829.36 m2, 31.5%), lawn space (1040.79 m2, 39.6%), and an extensive green roof (759.92 m2, 28.9%). The extensive green roof was comprised by vegetation areas, a narrow pathway and several resting places. The vegetation areas were covered with herbs, sedums, shrubs, and arbors above shallow substrates (20 cm in depth) (Getter et al. 2009; Jim and Peng 2012; Xiao et al. 2014). The bare roof (392.30 m2) had a light gray concrete coating on its surface bounded by parapet walls with the height of 1.2 m (see Fig. 1).
Two automatic weather stations represented the local climate zone surrounding the two roofs. One station (Station S), owned by the Seoul Metropolitan Government, was very close to both roofs selected (54 m from the bare roof and 30 m from the green roof); it only collected mean daily weather data with four-wire PT1000s (accuracy ± 0.3 °C and − 40 to + 60 °C). The other station (Station K), owned by the Korea Meteorological Administration, collected mean weather data every hour with four wire PT1000s (accuracy ± 0.3 °C and − 40 to + 60 °C). Station K was 464 m away from the two roofs (see Fig. 1).
Data Collection and Analysis
The air temperature measurements for the two roofs were obtained via a stationary survey with a Testo 174H (Testo, Germany). This device collected air temperature data with a thermistor and was mounted on a white shield to prevent self-heating (Erell et al. 2003; Oke 2004; Park et al. 2017). One of the measurement sets was obtained in the middle of the extensive green roof area on the green roof, and the other was in the middle of the bare roof (see Fig. 1). Both sets were 1.5 m above each roof’s ground surface to gather the air temperature data (Oke 2004) (see Fig. 1). The accuracy of the Testo 174H was ± 0.5 °C, and its measuring range was from − 20 to + 70 °C. Air temperatures were continuously recorded every minute from August 7 to August 11, 2012. During the measurement period, the weather in Gangnam-gu was clear, except for on August 10 when it rained in the daytime. The mean ambient temperature was 29.3 °C (min. 24.6 °C and max. 36.4 °C), and the mean relative humidity was 65.2% (min. 57.1% and max. 73.2%). The mean wind velocity was 1.12 m/s (max. 4.6 m/s) and the mean wind direction was northwesterly (degree direction 318). Moreover, during the daytime of the measurement days, the bare roof had received solar radiation avoiding shadows from surrounded taller buildings because the bare roof was too far away from those buildings and the lengths of shadows were not long enough to reach the roof. As for the green roof, surrounded tall buildings were on the west and south side of it in a ranged Euclidean distance away (52.6–81.1 m) (see Fig. 1). The shadows by those buildings met the green roof during sunrise (6–8 h) and sunset (17–19 h) when the air temperature was decreased. However, these shadows avoided completely the green roof during the hottest hours of the day (9–16 h).
For 3 days and 12 h, 10,080 data points were collected from the each roof, respectively; these were comprised of 5040 air temperature data points and 5040 relative humidity data points, which were measured every minute. All of the air temperature data were converted from 5040 data points to 84 data points, to imply hourly data.
With regards to the air temperature of the local climate, we used the hourly air temperature data collected by Station K (TK) because its data amount matched the amount of each roof’s data. At the first glance, the Station S seemed to represent the local climate regarding the distance from each roof. (30 m from the green roof and 54 m from the bare roof) than Station K did (464 m away). However, the air temperature data from Station S (TS) included only four data during the whole measurement days (April 7, 8, 9, and 11) because the Station S produced one daily mean data per day. The number of data from Station S (N = 4) was not enough to make an accurate comparison with the data collected from the two roofs (N = 84 each). Station K offered hourly data, which matched the amount collected from each roof (N = 84). To verify the reliability in using the data from Station K as our reference data representing the local climate for our study area, an independent samples t test was conducted on both stations’ daily data through SPSS (99% confidence interval of the difference) after converting Station K’s hourly data to daily data. The result showed that the mean TS and mean TK were not significantly different (t = − 0.467 < 2.58 and p = 0.657 > 0.01). Consequently, TK could be compared to the two roofs’ data.
Then, a paired samples t test through SPSS was conducted to compare the mean air temperature data of the bare roof (TB) to that of the green roof (TG). This test showed the difference between TB and TG (ΔTB–G) both during the day and at night. An independent samples through SPSS t test was conducted to find the difference between diurnal TG and nocturnal TG, as well as the difference between diurnal TB and nocturnal TB. After TK was statistically approved, an one-way analysis of variance (ANOVA) was performed to determine the differences among TK, TG, and TB through SPSS. Six regression models using SPSS were created to identify the relationships between TG and TK, and TB and TK.
Results
Air Temperature Difference Between T G and T B
During the day and night when the measurements were made, TG was 6.1 °C lower than TB (see Table 1). The difference between TB and TG (ΔTB–G) was greater during the daytime than at night. During the day, ΔTB–G ranged from 22.6 to 4.1 °C, and the mean value was 10.8 °C. The maximum TG value was 42.1 °C during the daytime and 33.3 °C at night, while the minimum TG value was 27.3 °C during the daytime and 23.7 °C at night (see Fig. 2). The maximum TB value was 64.7 °C during the daytime and 35.2 °C at night, while the minimum TB value was 31.4 °C during the daytime and 24.5 °C at night (see Fig. 2). Throughout the day and night, TG fluctuated less (7.97 °C) than did TB (17.78 °C). The mean ΔTB–G was 10.8 °C during the daytime and 1.0 °C at night (see Table 1).
Differences Among T K, T G, and T B
From the results of the ANOVA test, it was determined that throughout the test period, TK, TG, and TB were significantly different; the value for ΔTB–K was 7.97 °C and for ΔTG–K was 1.89 °C (see Table 1). Specifically, the diurnal ΔTB–K was 15.6 °C, and the diurnal ΔTG–K was 4.8 °C, while the nocturnal ΔTB–K was − 0.1 °C, and the nocturnal ΔTG–K was − 1.12 °C (see Table 1). Overall of the results from the three groups, TB had the highest value, followed by TG and TK. The drop in ΔTB–K was far larger than in ΔTG–K. This consequence matched Duncan’s homogeneous subsets, resulting in TK and TG belonging to one subset and TB belonging to another.
Mitigation Effect of Green Roofs on UHIs in a Local Climate Zone
As a result of the regression analysis, six logarithmic functions were finalized (see Table 2). Through all of the functions, as TK increased, either TG or TB increased along a positive logarithmic line. However, the models had different R2 values to indicate the models’ goodness of fit. The two nocturnal models (E3 and E4) were the most fitted to the regression line, more so than the overall or diurnal models. Furthermore, at night the cooling of the green and bare roofs showed little difference from one another. During the daytime, the fitness of the regression lines decreased, but E1 was far more fitted than E2. E1 in the diurnal models had similar R2 value to that of E5 in the overall models. Moreover, as diurnal TK increased, diurnal TG increased smaller than diurnal TB. Likewise, as overall TK increased, overall TG increased much smaller than overall TB. From E1 and E2 to E5 and E6 the difference of the slopes between E1 and E5 was small but the difference between E2 and E6 was large. Thus, diurnal air temperature fluctuation of each roof mainly influenced each overall air temperature fluctuation because both nocturnal models were not different. Throughout the day TG reacted smaller to TK than TB did.
Discussion and Conclusions
The diurnal difference between TG and TB was due to several cooling characteristics of each roof. As for the green roof, tree crowns and leaves of herbs blocked the direct solar radiation falling to the ground making shadows as well as avoiding much heat storage during the day (Akbari 2002; Gago et al. 2013; Getter et al. 2009; Kleerekoper et al. 2012). In addition, this green roof produced humidity evaporated from leaves of trees, grass, and herbs (Niachou et al. 2001; Getter and Rowe 2006; Susca et al. 2011) even though it had a shallow substrate (under 20 cm) which stored less heat than a deeper substrate did in the intensive green roof system (Castletona et al. 2010; Tsang and Jim 2011). Meanwhile, the bare roof gained, reflected, and accumulated direct solar radiation and showed very hot air temperatures during the day (Grant 2006; Speak et al. 2013; Ouldboukhitine et al. 2014). Thus, green roofs, even of an extensive type, were more effective in micro-UHI reduction than bare roofs.
Both values of nocturnal TG and TB reduced due to no additional solar radiation and little heat storage at night. But the significant differences between the nocturnal TG and the nocturnal TB prove that the extensive green roof was more effective to cool down due to its less emission of heat stored during the day (Gaffin et al. 2008; Giridharan et al. 2008; Smith and Levermore 2008).
In comparison among TK, TG, and TB, the green roof followed the graph of TK gently while TB drew steeper curves in the daytime. The TG increased more than the TK did (see Fig. 2) and it is due to the difference of the data collection height between two stations. The TG was resulted from near heated air on the roof while the TK was too far away from the roof to integrate the thermal consequences generated by the factors of heating such as solar radiated spaces and cooling facilities producing waste heat and cooling factors such as wind, green spaces, parks, and shaded spaces by buildings (Oke 1987; Stewart and Oke 2012; Stewart et al. 2014; Park et al. 2017). At night, the green roof’s less heat emission resulted in the lower air temperature than the TK (see Fig. 2), while other bare roofs and impervious covers emitted heat which was stored during the daytime and kept the local area warm (Wong et al. 2003; Jim 2014c; Tan et al. 2014). This result supports previous studies reporting that even an extensive green roof can be a cooling factor in cities experiencing a tropical night (Castletona et al. 2010; Tsang and Jim 2011).
Referring to E1 and E2 or E5 and E6, we can expect how a local urban area would experience its UHI reduction if its concrete covered bare roof is transformed to an extensive green roof (Sailor 2008; Zinzi and Agnoli 2012; Coma et al. 2016). Because the ambient air temperature of Station K contained various heat sources from the entire local climate zone, the green roof’s cooling on the local climate was hidden (Oke 2004; Stewart et al. 2014). However, according to these linear models, the more a local climate gets transformed green roofs, the more it gets the UHI reduction (Santamouris 2014).
Our results based on field experiments contribute to produce evidenced input values for a UHI simulation model which analyzes and expects a local climate reduction through green roofs’ provision in summer (Ouldboukhitine et al. 2011; Chan and Chow 2013). Our findings also expect that if bare urban roofs in a hot local climate are transformed into green roofs, the local climate will be enhanced in upper parts of the boundary layer climate (Oke 1987). This study will be useful to urban planners and designers, policy makers, and researchers seeking to establish thermal mitigation strategies and identify the usefulness of small green spaces in UHIs. In identical local climate zones, especially in highly built-up locations, small green spaces such as green roofs can play an important role in mitigating UHIs (Park et al. 2017).
Although the contributions of this study are significant, there are some limitations. The number of study sites was not sufficient, but accurately representing regional cooling effects. The locations were carefully and logically selected to study the effect of a particular local climate zone while they did not fully avoid side shading effects by close tall buildings. The area of the green roof was larger than that of the bare roof; however, other than in this respect, the two roofs offered identical conditions for analyzing micro-climatic differences via the concept of the local climate zone. The duration of measurement was not sufficient to determine the green roof’s UHI mitigation effect for the entire summer, because it included temperature gradients for just three and a half days although since these were the hottest days of the year, they could be considered representative of that year’s summer.
Our results highlight the differences in thermal mitigation between the two roof types, and thus should aid in mitigating heat in the upper boundary climate layer. Bare roofs in highly developed urban blocks require thermal mitigation strategies such as small, multilateral green spaces on the ground, roofs, and walls of buildings. The findings of our study also suggest that the use of green roofs is an effective strategy in mitigating UHIs at the district level. Through this study, UHI mitigation policy can adopt a wider spatial range of maintenance. Roofs with no green spaces are one of the main causes of UHI intensification in local climate zones, due to heat emissions from their surrounding area.
The endeavor to fill the knowledge gap regarding local climate zones and their implications for local cooling should continue; eventually, it will lead to actual UHI mitigation in urban blocks through the provision of green roofs. In service of that effort, more data from multiple measurement points will offer clearer indications of green roofs’ contribution to UHI mitigation. In future research, the selected local climate zones should be composed of green and bare roofs residing in similar thermal conditions such as their height from the ground, roof area, and so on. Also, it is necessary to study which types of green roofs will be most effective in reducing UHIs in local climate zones. The result will be economic value stemming from the knowledge of which local climate zones enjoy lower temperatures when green roofs are established.
References
Akbari H (2002) Shade trees reduce building energy use and CO2 emissions from power plants. Environ Pollut 116(SUPPL. 1):119–126. https://doi.org/10.1016/S0269-7491(01)00264-0
Blackhurst M, Hendrickson C, Matthews HS (2010) Cost-effectiveness of green roofs. J Archit Eng 16(4):136–143. http://ascelibrary.org/doi/abs/10.1061/(ASCE)AE.1943-5568.0000022
Castletona HF, Stovinb V, Beck SB, Davison JB (2010) Green roofs; building energy savings and the potential for retrofit. Energy Build 42(10):1582–1591. http://www.sciencedirect.com/science/article/pii/S0378778810001453
Chan ALS, Chow TT (2013) Evaluation of overall thermal transfer value (OTTV) for commercial buildings constructed with green roof. Appl Energy 107:10–24. https://doi.org/10.1016/j.apenergy.2013.02.010
Chen C-F (2013) Performance evaluation and development strategies for green roofs in Taiwan: a review. Ecol Eng 52:51–58. https://doi.org/10.1016/j.ecoleng.2012.12.083
Clark C, Adriaens P, Talbot FB (2008) Green roof valuation: a probabilistic economic analysis of environmental benefits. Environ Sci Technol 42(6):2155–2161. https://doi.org/10.1021/es0706652
Coma J, Pérez G, Solé C, Castell A, Cabeza LF (2016) Thermal assessment of extensive green roofs as passive tool for energy savings in buildings. Renew Energy 85:1106–1115. https://doi.org/10.1016/j.renene.2015.07.074
Costanzo V, Evola G, Marletta L (2016) Energy savings in buildings or UHI mitigation? Comparison between green roofs and cool roofs. Energy Build 114:247–255. https://doi.org/10.1016/j.enbuild.2015.04.053
Coutts AM, Daly E, Beringer J, Tapper NJ (2013) Assessing practical measures to reduce urban heat: green and cool roofs. Build Environ 70:266–276. https://doi.org/10.1016/j.buildenv.2013.08.021
Doick K, Hutchings T (2013) Air temperature regulation by urban trees and green infrastructure. Forestry Commission Research Note 12, pp 1–10. https://www.forestry.gov.uk/pdf/FCRN012.pdf/$FILE/FCRN012.pdf
Doug B, Hitesh D, James L, Paul M (2005) Report on the environmental benefits and costs of green roof technology for the city of Toronto. Toronto. https://mpra.ub.uni-muenchen.de/70526/1/MPRA_paper_70526.pdf
Dvorak B, Volder A (2010) Green roof vegetation for North American ecoregions: a literature review. Landsc Urban Plan 96(4):197–213. https://doi.org/10.1016/j.landurbplan.2010.04.009
Erell E, Leal V, Maldonado E (2003) On the measurement of air temperature in the presence of strong solar radiation. In: 5th int conf urban climate, Lodz. http://www.academia.edu/download/45321327/On_the_measurement_of_air_temperature_in20160503-27168-14v67nr.pdf
Gaffin SR, Rosenzweig C, Khanbilvardi R, Parshall L, Mahani S, Glickman H, Goldberg R, Blake R, Slosberg RB, Hillel D (2008) Variations in New York city’s urban heat island strength over time and space. Theor Appl Climatol 94:1–11. https://doi.org/10.1007/s00704-007-0368-3
Gaffin SR, Khanbilvardi R, Rosenzweig C (2009) Development of a green roof environmental monitoring and meteorological network in New York City. Sensors 9(4):2647–2660. https://doi.org/10.3390/s90402647
Gago EJ, Roldan J, Pacheco-Torres R, Ordonez J (2013) The city and urban heat islands: a review of strategies to mitigate adverse effects. Renew Sustain Energy Rev 25:749–758. https://doi.org/10.1016/j.rser.2013.05.057
Getter KL, Rowe DB (2006) The role of extensive green roofs in sustainable development. HortScience 41(5):1276–1285. http://doi.org/10.17776/csj.30292
Getter KL, Bradley Rowe D, Cregg BM (2009) Solar radiation intensity influences extensive green roof plant communities. Urban For Urban Green 8(4):269–281. https://doi.org/10.1016/j.ufug.2009.06.005
Giridharan R, Lau SSY, Ganesan S, Givoni B (2008) Lowering the outdoor temperature in high-rise high-density residential developments of coastal Hong Kong: the vegetation influence. Build Environ 43(10):1583–1595. http://www.sciencedirect.com/science/article/pii/S0360132307001813
Grant G (2006) Extensive green roofs in London. Urban Habitats 4(1):51–65
Hamada S, Ohta T (2010) Seasonal variations in the cooling effect of urban green areas on surrounding urban areas. Urban For Urban Green 9(1):15–24. https://doi.org/10.1016/j.ufug.2009.10.002
Hamdi R, Schayes G (2008) Sensitivity study of the urban heat island intensity to urban characteristics. Int J Climatol 982:973–982. https://doi.org/10.1002/joc
Harlan SL, Brazel AJ, Prashad L, Stefanov WL, Larsen L (2006) Neighborhood microclimates and vulnerability to heat stress. Soc Sci Med 63:2847–2863. https://doi.org/10.1016/j.socscimed.2006.07.030
Jim CY (2014a) Air-conditioning energy consumption due to green roofs with different building thermal insulation. Appl Energy 128:49–59. https://doi.org/10.1016/j.apenergy.2014.04.055
Jim CY (2014b) Building thermal-insulation effect on ambient and indoor thermal performance of green roofs. Ecol Eng 69:265–275. https://doi.org/10.1016/j.ecoleng.2014.04.016
Jim CY (2014c) Passive warming of indoor space induced by tropical green roof in winter. Energy 68:272–282. https://doi.org/10.1016/j.energy.2014.02.105
Jim CY, Peng LLH (2012) Weather effect on thermal and energy performance of an extensive tropical green roof. Urban For Urban Green 11(1):73–85. https://doi.org/10.1016/j.ufug.2011.10.001
Karachaliou P, Santamouris M, Pangalou H (2016) Experimental and numerical analysis of the energy performance of a large scale intensive green roof system installed on an office building in Athens. Energy Build 114:256–264. https://doi.org/10.1016/j.enbuild.2015.04.055
Kim J-H, Gu D, Sohn W, Kil S-H, Kim H, Lee D-K (2016) Neighborhood landscape spatial patterns and land surface temperature: an empirical study on single-family residential areas in Austin, Texas. Int J Environ Res Public Health 13(9):1–15. https://doi.org/10.3390/ijerph13090880
Kjelgren RK, Clark JR (1992) Microclimates and tree growth in three urban spaces. J Environ Hortic 10(3):139–145
Kleerekoper L, van Esch M, Salcedo TB (2012) How to make a city climate-proof, addressing the urban heat island effect. Resour Conserv Recycl 64:30–38. https://doi.org/10.1016/j.resconrec.2011.06.004
Köhler M, Schmidt M, Laar M (2003) Green roofs as a contribution to reduce urban heat islands. In: World climate & energy event, Rio de Janeiro, pp 493–497
Kumar R, Kaushik S (2005) Performance evaluation of green roof and shading for thermal protection of buildings. Build Environ 40(11):1505–1511. https://doi.org/10.1016/j.buildenv.2004.11.015
Lazzarin RM, Castellotti F, Busato F (2005) Experimental measurements and numerical modelling of a green roof. Energy Build 37(12):1260–1267. https://doi.org/10.1016/j.enbuild.2005.02.001
Lehmann I, Mathey J, Rößler S, Bräuer A, Goldberg V (2014) Urban vegetation structure types as a methodological approach for identifying ecosystem services—application to the analysis of micro-climatic effects. Ecol Indic 42:58–72. https://doi.org/10.1016/j.ecolind.2014.02.036
Li D, Bou-Zeid E, Oppenheimer M (2014) The effectiveness of cool and green roofs as urban heat island mitigation strategies. Environ Res Lett 9:55002. https://doi.org/10.1088/1748-9326/9/5/055002
Loughner CP, Allen DJ, Zhang DL, Pickering KE, Dickerson RR, Landry L (2012) Roles of urban tree canopy and buildings in urban heat island effects: parameterization and preliminary results. J Appl Meteorol Climatol 51(10):1775–1793. https://doi.org/10.1175/JAMC-D-11-0228.1
McPherson EG, Muchnick J (2005) Effects of street tree shade on asphalt concrete pavement performance. J Arboric 31(6):303–310
Memon RA, Leung DYC, Chunho L (2008) A review on the generation, determination and mitigation of urban heat island. J Environ Sci (China) 20(1):120–128
Middel A, Chhetri N, Quay R (2015) Urban forestry and cool roofs: assessment of heat mitigation strategies in Phoenix residential neighborhoods. Urban For Urban Green 14(1):178–186. https://doi.org/10.1016/j.ufug.2014.09.010
Mullen JD, Lamsal M, Colson G (2013) Green roof adoption in Atlanta, Georgia: the effects of building characteristics and subsidies on net private, public, and social benefits. Environ Sci Technol 47(19):10824–10831. http://pubs.acs.org/doi/abs/10.1021/es401806j
Napoli M, Massetti L, Brandani G, Petralli M, Orlandini S (2016) Modeling tree shade effect on urban ground surface temperature. J Environ Qual 45(1):146–156
Niachou A, Papakonstantinou K, Santamouris M, Tsangrassoulis A, Mihalakakou G (2001) Analysis of the green roof thermal properties and investigation of its energy performance. Energy Build 33(7):719–729. https://doi.org/10.1016/S0378-7788(01)00062-7
Oke TR (1987) Boundary layer climates, 2nd edn. Routledge, New York
Oke TR (2004) Initial guidance to obtain representative meteorological observations at urban sites. World Meteorological Organization. http://www.wmo.int/pages/prog/www/IMOP/publications/IOM-81/IOM-81-UrbanMetObs.pdf
Ouldboukhitine S-E, Belarbi R, Jaffal I, Trabelsi A (2011) Assessment of green roof thermal behavior: a coupled heat and mass transfer model. Build Environ 46(12):2624–2631. https://doi.org/10.1016/j.buildenv.2011.06.021
Ouldboukhitine S-E, Belarbi R, Sailor DJ (2014) Experimental and numerical investigation of urban street canyons to evaluate the impact of green roof inside and outside buildings. Appl Energy 114:273–282. https://doi.org/10.1016/j.apenergy.2013.09.073
Park J, Kim J-H, Lee DK, Park CY, Jeong SG (2017) The influence of small green space type and structure at the street level on urban heat island mitigation. Urban For Urban Green 21:203–212. https://doi.org/10.1016/j.ufug.2016.12.005
Petralli M, Massetti L, Orlandini S (2009) Air temperature distribution in an urban park: Differences between open-field and below a canopy. In: 7th int conf urban climate, Yokohama
Ren Z, He X, Zheng H, Zhang D, Yu X, Shen G, Guo R (2013) Estimation of the relationship between urban park characteristics and park cool island intensity by remote sensing data and field measurement. Forests 4(4):868–886. https://doi.org/10.3390/f4040868
Rosenzweig C, Gaffin S, Parshall L (2006) Green roofs in the New York Metropolitan Region. Columbia University Center for Climate Systems Research and NASA Goddard Institute for Space Studies. New York. https://pdfs.semanticscholar.org/0674/e24ef22180c90a9fde90f0573c782a7f84eb.pdf#page=17
Saaroni H, Ben-Dor E, Bitan A, Potchter O (2000) Spatial distribution and microscale characteristics of the urban heat island in Tel-Aviv, Israel. Landsc Urban Plan 48(1–2):1–18. https://doi.org/10.1016/S0169-2046(99)00075-4
Sailor D (2008) A green roof model for building energy simulation programs. Energy Build 40:1466–1478. http://www.sciencedirect.com/science/article/pii/S0378778808000339
Santamouris M (2014) Cooling the cities—a review of reflective and green roof mitigation technologies to fight heat island and improve comfort in urban environments. Sol Energy 103:682–703. https://doi.org/10.1016/j.solener.2012.07.003
Scherba A, Sailor DJ, Rosenstiel TN, Wamser CC (2011) Modeling impacts of roof reflectivity, integrated photovoltaic panels and green roof systems on sensible heat flux into the urban environment. Build Environ 46(12):2542–2551. https://doi.org/10.1016/j.buildenv.2011.06.012
Shashua-Bar L, Pearlmutter D, Erell E (2011) The influence of trees and grass on outdoor thermal comfort in a hot-arid environment. Int J Climatol 31(10):1498–1506. https://doi.org/10.1002/joc.2177
Smith C, Levermore G (2008) Designing urban spaces and building to improve sustainability and quality of life in a warmer world. Energy Policy 36:4558–4562
Solecki WD, Rosenzweig C, Parshall L, Pope G, Clark M, Cox J, Wiencke M (2005) Mitigation of the heat island effect in urban New Jersey. Environ Hazards 6(1):39–49. https://doi.org/10.1016/j.hazards.2004.12.002
Speak AF, Rothwell JJ, Lindley SJ, Smith CL (2013) Reduction of the urban cooling effects of an intensive green roof due to vegetation damage. Urban Clim 3:40–55. https://doi.org/10.1016/j.uclim.2013.01.001
Spronken-Smith RA, Oke TR (1998) The thermal regime of urban parks in two cities with different summer climates. Int J Remote Sens 19(11):2085–2104. https://doi.org/10.1080/014311698214884
Stewart ID, Oke TR (2012) Local climate zones for urban temperature studies. Bull Am Meteorol Soc 93:1879–1900. https://doi.org/10.1175/BAMS-D-11-00019.1
Stewart ID, Oke TR, Krayenhoff ES (2014) Evaluation of the “local climate zone” scheme using temperature observations and model simulations. Int J Climatol 34(4):1062–1080. https://doi.org/10.1002/joc.3746
Sun T, Grimmond CSB, Ni G-H (2016) How do green roofs mitigate urban thermal stress under heat waves? J Geophys Res Atmos 121(10):5320–5335. https://doi.org/10.1002/2016JD024873
Susca T, Gaffin SR, Dell’osso GR (2011) Positive effects of vegetation: urban heat island and green roofs. Environ Pollut 159(8–9):2119–2126. https://doi.org/10.1016/j.envpol.2011.03.007
Tan J, Zheng Y, Tang X, Guo C, Li L, Song G, Zhen X, Yuan D, Kalkstein AJ, Li F, Chen H (2010) The urban heat island and its impact on heat waves and human health in Shanghai. Int J Biometeorol 54(1):75–84. https://doi.org/10.1007/s00484-009-0256-x
Tan CL, Wong NH, Jusuf SK (2014) Effects of vertical greenery on mean radiant temperature in the tropical urban environment. Landsc Urban Plan 127:52–64
Tsang SW, Jim CY (2011) Theoretical evaluation of thermal and energy performance of tropical green roofs. Energy 36(5):3590–3598. https://doi.org/10.1016/j.energy.2011.03.072
Vijayaraghavan K (2016) Green roofs: a critical review on the role of components, benefits, limitations and trends. Renew Sustain Energy Rev 57:740–752. https://doi.org/10.1016/j.rser.2015.12.119
Williams NSG, Rayner JP, Raynor KJ (2010) Green roofs for a wide brown land: opportunities and barriers for rooftop greening in Australia. Urban For Urban Green 9(3):245–251. https://doi.org/10.1016/j.ufug.2010.01.005
Wong JKW, Lau LS-K (2013) From the “urban heat island” to the “green island”? A preliminary investigation into the potential of retro fitting green roofs in Mongkok district of Hong Kong. Habitat Int 39:25–35. https://doi.org/10.1016/j.habitatint.2012.10.005
Wong N, Chen Y, Ong C, Sia A (2003) Investigation of thermal benefits of rooftop garden in the tropical environment. Build Environ 38(2):261–270. http://www.sciencedirect.com/science/article/pii/S0360132302000665
Xiao M, Lin Y, Han J, Zhang G (2014) A review of green roof research and development in China. Renew Sustain Energy Rev 40:633–648. https://doi.org/10.1016/j.rser.2014.07.147
Yuen B, Nyuk Hien W (2005) Resident perceptions and expectations of rooftop gardens in Singapore. Landsc Urban Plan 73(4):263–276. https://doi.org/10.1016/j.landurbplan.2004.08.001
Zinzi M, Agnoli S (2012) Cool and green roofs. An energy and comfort comparison between passive cooling and mitigation urban heat island techniques for residential buildings in the Mediterranean region. Energy Build 55:66–76. https://doi.org/10.1016/j.enbuild.2011.09.024
Acknowledgements
This research was supported by a Grant (16AUDP-B102406-02) from the Architecture and Urban Development Research Program (AUDP) funded by the Ministry of Land, Infrastructure and Transport of Korean government.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Park, J., Kim, JH., Dvorak, B. et al. The Role of Green Roofs on Microclimate Mitigation Effect to Local Climates in Summer. Int J Environ Res 12, 671–679 (2018). https://doi.org/10.1007/s41742-018-0124-9
Received:
Revised:
Accepted:
Published:
Issue Date: