Avoid common mistakes on your manuscript.
Dear Editor,
In a previous project [1], we developed a predictive model that enabled Roche/Genentech quality leads oversight of adverse event (AE) reporting. External clinical trial datasets such as Project Data Sphere (PDS) [2] allowed us to further test our machine learning-based approach to alleviate concerns of overfitting and to demonstrate the reproducibility of our research.
Our primary objective was to further validate our model for detection of AE under-reporting using PDS data. Our secondary objective was to build an oncology-specific model using a combined dataset of Roche and PDS data. The scope remained as predicting AEs—not adverse drug reactions—that occur in clinical trials. Good clinical practice requires all AEs (regardless of the causal relationship between the drug intake and the events) to be reported in a timely manner [3].
The curation process of downloadable PDS studies (as of November 2019) left five studies that fulfilled our data requirements, as sponsors are not required to share the full datasets. They were large phase III trials and included 742 investigator sites, 2363 subjects, and 51,847 visits. Hence, we could use PDS data to achieve our objectives.
The oncology-specific model was built using the methodology described in our previous manuscript [1]. We used a combined dataset of 53 completed oncology studies (Roche + PDS). Our final model used 38 features built from patient and study attributes.
To test whether our model can be applied to non-Roche studies, we compared the quality of the predictions using a scatter plot (Fig. 1a) and found that, within a range of 0–150 on both axes (> 94% of all datapoints, our region of interest [ROI]), the predictions matched the observed values for both datasets equally well. To quantify the goodness of fit, we used scale-independent performance metrics (which are adequate for comparing the goodness of fit of different datasets used by the same model [4]): symmetric mean absolute percentage error (SMAPE) [5] and symmetric mean absolute poisson significance level (SMASL). The latter is calculated by subtracting 0.5 from each poisson significance level measurement, converting it to its absolute value, and taking the mean. SMASL puts equal weight on over- and under-predicting and has a range from 0 to 0.5 (i.e., The smaller the value the better the fit). Considering SMAPE, average predictions for the PDS study sites were slightly better than for the Roche study sites, whereas the reverse was true for SMASL (Fig. 1b). We concluded that the goodness of fit for both datasets using our model was very similar within the ROI.
For the secondary objective, we tested how well the oncology model (using Roche and PDS data and the same algorithm [1]) would detect simulated test cases on data not used for model training. For relevant simulation scenarios of 25%, 50%, and 75% under-reporting on the site level, our model scored an area under the curve (AUC) of the receiver operating characteristic curve of 0.60, 0.77, and 0.90, respectively. These AUC values were on par with the performance of our previous model (0.62, 0.79, 0.92).
Our main challenge was the lack of availability of external data that had all required attributes. Initiatives such as PDS or TransCelerate should be further promoted, as sharing data from historical clinical trials could serve a variety of uses [6].
Our analysis supports our approach for detection of AE under-reporting and provides rationale to integrate our model into routine clinical quality practices. Furthermore, following the same methodology, we could produce a model for detection of AE under-reporting in oncology trials based on internal and external study data.
References
Menard T, Barmaz Y, Koneswarakantha B, Bowling R, Popko L. Enabling data-driven clinical quality assurance: predicting Adverse Event reporting in clinical trials using machine learning. Drug Saf. 2019;42(9):1045–53.
Project Data Sphere. https://www.projectdatasphere.org/projectdatasphere/html/home. Accessed 15 Nov 2019.
International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. E26(R2) Guideline for Good Clinical Practices. 2016. https://database.ich.org/sites/default/files/E6_R2_Addendum.pdf. Accessed 15 Nov 2019.
Fildes R, Makridakis S. Forecasting and loss functions. Int J Forecast. 1988;4(4):545–50.
Makridakis S. Accuracy measures: theoretical and practical concerns. Int J Forecast. 1993;9(4):527–9.
TransCelerate Placebo Standard of Care Data Sharing workstream (pSOC). https://transceleratebiopharmainc.com/initiatives/placebo-standard-of-care/. Accessed 15 Nov 2019.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Funding
Funding was supplied by Roche/Genentech.
Conflicts of interest
Timothé Ménard, Björn Koneswarakantha, Donato Rolo, Yves Barmaz, Rich Bowling, and Leszek Popko were employed by Roche/Genentech at the time this research was completed.
Ethics statement
All human subject data used in this analysis were used in a de-identified format.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/.