Abstract
Double skin steel-concrete composite walls have been increasingly used in civil engineering applications. However, the advantages of these walls have not been fully recognized due to the lack of appropriate technical guidelines for capacity design. In this paper, the local buckling strength of steel plate were firstly reviewed in terms of specifications incorporated in several modern codes. A methodology to predict the strength of steel plate with restraint of both concrete and shear studs was proposed based on the explicit solution for local buckling of steel plate in composite shear walls subjected to uniform axial compression and with elastically rotational restraint at loaded and unloaded edges. The results were compared with various previous experimental data and good agreement was observed. Furthermore, the load carrying capacity of composite walls was derived from the superposition of the contribution of steel plate and concrete. The predicted values from the proposed equations, together with the resulted determined from modern codes, were compared with the experimental results. It was found that both the proposed method and JEAG 4618 offer reasonable predictions while AISC 360 and KEPIC-SNG always underestimate the actual values.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
ACI 318-08 2008. Building code requirements for structural concrete and commentary. Farmington Hills: American Concrete Institute.
Akiyama, H., Sekimoto, H, et al (1991). “A compression and shear loading tests of concrete filled steel bearing wall.” In: Transaction of 11th Structural Mechanics in Reactor Technology (SMiRT-11), pp. 323–328.
ANSI/AISC 360-10 (2010). Specification for Structural Steel Buildings. American Institute of Steel Construction, Chicago, Illinois.
Chen, L., Mahmoud, H., Tong, S., and Zhou, Y. (2015). “Seismic behavior of double steel plate–HSC composite walls.” Engineering Structures, 102, pp. 1–12.
Choi, B.J., and Han, H.S. (2009). “An experiment on compressive profile of the unstiffened steel plate-concrete structures under compression loading.” Steel and Composite Structures, 9(6), pp. 519–534.
Choi, B.J., Kang, C.K., and Park, H.Y. (2014). “Strength and behavior of steel plate–concrete wall structures using ordinary and eco-oriented cement concrete under axial compression.” Thin-Walled Structures, 84, pp. 313–324.
Emori, K. (2002). “Compressive and shear strength of concrete filled steel box wall.” Steel Structures, 2, pp. 29–40.
EN 1998-1 (2004). Eurocode 8: Design of structures for earthquake resistance-Part 1: general rules, seismic action and rules for buildings. CEN, Brussels: European Committee for Standardization.
Eom, T.S., Park, H.G., Lee, C.H., Kim, J.H., and Chang I.H. (2009). “Behavior of double skin composite wall subjected to in-plane cyclic loading.” Journal of Structural Engineering, 135(10), pp. 1239–1249.
GB 50011-2010 (2010). Code for seismic design of buildings. Beijing: China Ministry of Construction.
Hossain, K.M.A., and Wright, H.D. (2005). “Finite element modelling of the shear behaviour of profiled composite walls incorporating steel-concrete interaction.” Structural Engineering and Mechanics, 21(6), pp. 659–676.
Hossain, K.M.A., Mol, L.K., and Anwar, M.S. (2015). Axial load behaviour of pierced profiled composite walls with strength enhancement devices.” Journal of Constructional Steel Research, 2015, pp. 48–64.
Hu, H.S., Nie, J.G., and Eatherton, M.R. (2014). “Deformation capacity of concrete-filled steel plate composite shear walls.” Journal of Constructional Steel Research, 103, pp. 148–158.
Huang, Z., Liew, J.Y.R. (2016). “Structural behavior of steel–concrete–steel sandwich composite wall subjected to compression and end moment. Thin-Walled Structures, 98, pp. 592–606.
JEAG 4618-2005 (2005). Technical guidelines for seismic design of steel plate concrete structures: for buildings and structures. Architectural Institute of Japan.
Kanchi, M. et al (1996). Experimental study on a concrete filled steel structure Part 2 Compressive tests (1). In: Summary of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures, pp. 1071–1072.
Korea Electric Association (KEA) (2010). Steel-concrete structures (KEPIC-SNG), Korea Electric Power Industry Code.
le Roux, R.C., Wium, J.A. (2012). “Assessment of the behaviour factor for the seismic design of reinforced concrete structural walls according to SANS 10160-Part 4.” Journal of the South African Institution of Civil Engineering, 54(1), pp. 69–80.
Miyauchi, Y. et al (1996). Experimental study on a concretefilled steel structure, Part 3 Compressive test (2). In: Summary of Technical Papers of Annual Meeting, Architectural Institute of Japan, pp. 1073–1074.
Mohanraj, E.K., Kandasamy, S., and Malathy, R. (2011). “Behaviour of steel tubular stub and slender columns filled with concrete using recycled aggregates.” Journal of the South African Institution of Civil Engineering, 53(2), pp. 31–38.
Ji, X., Jiang, F., and Qian, J. (2013). “Seismic behavior of steel tube-double steel plate-concrete composite walls: Experimental tests.” Journal of Constructional Steel Research, 86, pp. 17–30.
Nie, J.G., Hu, H.S., Fan, J.S., Tao, M.X., Li, S.Y., and Liu, F.J. (2013). “Experimental study on seismic behavior of high-strength concrete filled double-steel-plate composite walls.” Journal of Constructional Steel Research, 88, pp. 206–219.
Qian, J., Jiang, Z., and Ji, X. (2012). “Behavior of steel tubereinforced concrete composite walls subjected to high axial force and cyclic loading.” Engineering Structures, 36, pp. 173–184.
Qin, Y. (2016). “Local buckling of steel plate in double skin composite shear wall under axial compression.” Steel and Composite Structures. (in review)
Sakamoto, M. et al (1985). Experimental study on concrete filled steel bearing wall Part 2: Compression characteristics. In: Summary of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures, pp. 1325–1326.
Su, R.K.L., and Wong, S.M. (2007). “Seismic behaviour of slender reinforced concrete shear walls under high axial load ratio.” Engineering Structures, 29(8), pp. 1957–1965.
Usami, S., Akiyama, H., Narikawa, M., Hara, K., Takeuchi, M., and Sasaki, N. (1995). Study on a concrete filled steel structure for nuclear plants (part 2). Compressive loading tests on wall members. In: Transaction of 13th Structural Mechanics in Reactor Technology (SMiRT-13), pp. 21–26.
Vecchio, F.J., and McQuade, I. (2011). “Towards improved modeling of steel-concrete composite wall elements.” Nuclear Engineering and Design, 241(8), pp. 2629–2642.
Zhang, K., Varma, A.H., Malushte, S.R., and Gallocher, S. (2014). “Effect of shear connectors on local buckling and composite action in steel concrete composite walls.” Nuclear Engineering and Design, 269, pp. 231–239.
Zhang, Y., Li, X., He, Q., and Yan, X. (2016). “Experimental study on local stability of composite walls with steel plates and filled concrete under concentric loads.” China Civil Engineering Journal, 49(1), pp. 62–68.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Qin, Y., Shu, GP., Fan, SG. et al. Strength of double skin steel-concrete composite walls. Int J Steel Struct 17, 535–541 (2017). https://doi.org/10.1007/s13296-017-6013-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13296-017-6013-9