Abstract
Investigating the effects of various physical stimuli on cells is important for improving the efficiency of tissue repair and regeneration. In this research, we developed a dynamic well plate system by integrating the advantages of conventional well plates and a bioreactor to provide simultaneous physical stimuli of shear stress and a static magnetic field. The dynamic well plate involving perfusion of culture medium can control hydrodynamic shear while retaining the inherent simplicity of conventional well plates. The specific well plate cover was designed to load shear stress on cells during cultivation and was built to fit over a standard six-well plate. Additionally, to investigate the effects of a magnetic field on cell proliferation, a static neodymium magnet was placed beneath each well. To assess the system developed, calf pulmonary artery endothelial (CPAE) cells were cultured using the developed system. CPAE cells under hydrodynamic shear stress conditions were elongated and aligned in the direction of the flow and the magnetic field enhanced CPAE cell proliferation. Simultaneous application of a magnetic field and shear flow in CPAE cell cultivation allowed the development of optimized culture conditions, initially for cell proliferation and then for functional expression, such as cell shape changes.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Abbreviations
- EI:
-
elongation index value
- A:
-
area of cell
- P:
-
perimeter of cell
- τ :
-
wall shear stress
- Qout :
-
volume flux of media
- µ :
-
viscosity of media
- r:
-
radial position from center of a well of a well plate
- h:
-
distance between bottom surface of a plunger and top surface of a well
References
Polacheck, W. J., Li, R., Uzel, S. G., and Kamm, R. D., “Microfluidic Platforms for Mechanobiology,” Lab on a Chip, Vol. 13, No. 12, pp. 2252–2267, 2013.
Davies, P. F., Remuzzi, A., Gordon, E. J., Dewey, C. F., and Gimbrone, M. A., “Turbulent Fluid Shear Stress Induces Vascular Endothelial Cell Turnover in Vitro,” Proceedings of the National Academy of Sciences, Vol. 83, No. 7, pp. 2114–2117, 1986.
Leclerc, E., David, B., Griscom, L., Lepioufle, B., Fujii, T., et al., “Study of Osteoblastic Cells in a Microfluidic Environment,” Biomaterials, Vol. 27, No. 4, pp. 586–595, 2006.
Malek, A. M., Gibbons, G. H., Dzau, V. J., and Izumo, S., “Fluid Shear Stress Differentially Modulates Expression of Genes Encoding Basic Fibroblast Growth Factor and Platelet-Derived Growth Factor B Chain in Vascular Endothelium,” Journal of Clinical Investigation, Vol. 92, No. 4, pp. 2013–2021, 1993.
Song, J. W., Gu, W., Futai, N., Warner, K. A., Nor, J. E., and Takayama, S., “Computer-Controlled Microcirculatory Support System for Endothelial Cell Culture and Shearing,” Analytical Chemistry, Vol. 77, No. 13, pp. 3993–3999, 2005.
Zheng, W., Jiang, B., Wang, D., Zhang, W., Wang, Z., and Jiang, X., “A Microfluidic Flow-Stretch Chip for Investigating Blood Vessel Biomechanics,” Lab on a Chip, Vol. 12, No. 18, pp. 3441–3450, 2012.
Magdesian, M. H., Sanchez, F. S., Lopez, M., Thostrup, P., Durisic, N., et al., “Atomic Force Microscopy Reveals Important Differences in Axonal Resistance to Injury,” Biophysical Journal, Vol. 103, No. 3, pp. 405–414, 2012.
Janet, M. T., Cheng, G., Tyrrell, J. A., Wilcox-Adelman, S. A., Boucher, Y., et al., “Mechanical Compression Drives Cancer Cells Toward Invasive Phenotype,” Proceedings of the National Academy of Sciences, Vol. 109, No. 3, pp. 911–916, 2012.
Ba, X., Hadjiargyrou, M., DiMasi, E., Meng, Y., Simon, M., et al., “The Role of Moderate Static Magnetic Fields on Biomineralization of Osteoblasts on Sulfonated Polystyrene Films,” Biomaterials, Vol. 32, No. 31, pp. 7831–7838, 2011.
Dini, L. and Abbro, L., “Bioeffects of Moderate-Intensity Static Magnetic Fields on Cell Cultures,” Micron, Vol. 36, No. 3, pp. 195–217, 2005.
Levesque, M. J., Liepsch, D., Moravec, S., and Nerem, R. M., “Correlation of Endothelial Cell Shape and Wall Shear Stress in a Stenosed Dog Aorta,” Arteriosclerosis, Thrombosis, and Vascular Biology, Vol. 6, No. 2, pp. 220–229, 1986.
Frank, M. W., “Fluid Mechanics,” Mcgraw-Hill College, 6th Ed., pp. 264–268, 2008.
Wang, Z., Sarje, A., Che, P.-L., and Yarema, K. J., “Moderate Strength (0.23-0.28 T) Static Magnetic Fields (SMF) Modulate Signaling and Differentiation in Human Embryonic Cells,” BMC genomics, Vol. 10, No. 1, Paper No. 356, 2009.
Rosen, A. D., “Mechanism of Action of Moderate-Intensity Static Magnetic Fields on Biological Systems,” Cell Biochemistry and Biophysics, Vol. 39, No. 2, pp. 163–173, 2003.
Ghodbane, S., Lahbib, A., Sakly, M., and Abdelmelek, H., “Bioeffects of Static Magnetic Fields: Oxidative Stress, Genotoxic Effects, and Cancer Studies,” Biomed Research International, Vol. 2013, Article ID: 602987, 2013.
Kim, E. C., Leesungbok, R., Lee, S. W., Lee, H. W., Park, S. H., et al., “Effects of Moderate Intensity Static Magnetic Fields on Human Bone Marrow-Derived Mesenchymal Stem Cells,” Bioelectromagnetics, Vol. 36, No. 4, pp. 267–276, 2015.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jin, S., Kim, JH. & Yun, WS. Development of dynamic well plate system for cell culture with mechanical stimulus of shear stress and magnetic field. Int. J. Precis. Eng. Manuf. 16, 2235–2239 (2015). https://doi.org/10.1007/s12541-015-0288-6
Received:
Revised:
Accepted:
Published:
Issue Date: