Abstract
Background
In patients with right dominant coronary circulation, the right ventricular (RV) myocardium and the inferior region of the left ventricular (LV) myocardium share a common source of blood flow. We hypothesized that stress/rest SPECT myocardial perfusion imaging (MPI) could detect reversible perfusion defects in the RV in some patients with LV inferior wall perfusion abnormalities.
Material and Methods
We identified 2 groups of patients with LV inferior wall perfusion defects (with or without defects in other regions of LV myocardium) from our database. Patients in group 1 (n = 17) had reversible perfusion defects in the RV free wall by visual analysis, while patients in group 2 (n = 17) did not. The images were processed with filtered back projection and, separately, with iterative reconstruction. The images were then re-processed using an automated quantitative software that is specifically designed to include the RV in the region of interest.
Results
There were 76% men in group 1 and 94% in group 2 (P <0.05). The mean age was 65±20 in group 1 vs. 63±18 years in group 2 (P < 0.05). The stress type was exercise in 30% in group 1 and 35% in group 2, with the remaining patients studied with pharmacological stress testing (P = NS). The presence of RV reversible perfusion defects using filtered back projection was more evident in 13 patients (75%), while it was better seen with iterative reconstruction in 4 patients (25%). By automated analysis, the RV reversible perfusion defect size was 19 ± 14% of RV myocardium.
Conclusion
This proof-of-principle study demonstrates that reversible RV perfusion defects suggestive of ischemia can be detected by SPECT myocardial perfusion imaging in some patients with LV inferior ischemia by visual analysis and can be quantitated by automated programs. Further studies on the diagnostic and prognostic relevance of assessing RV ischemia on SPECT MPI are needed.
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
The right ventricle (RV) is often not well visualized during SPECT myocardial perfusion imaging (MPI) regardless of the type of stress. This is likely due to lower myocardial blood flow (MBF) in the RV myocardium related to its lower muscle mass and its lower demand compared to the left ventricular (LV) myocardium. Further, due to the inherent limitations set by the resolution of SPECT MPI cameras, the partial volume effect will result in the RV appearing less bright than the LV.1 The exception to this are patients with pulmonary hypertension, who often exhibit prominent RV uptake due to the hypertrophied RV myocardium.2,3
However, we have been intrigued by the fact that in many patients, the RV uptake is sufficiently visible on MPI (using technetium-labeled tracers) to allow interpretation of the perfusion pattern in patients with known or suspected coronary artery disease (CAD) but no pulmonary hypertension. The short-axis, and to a lesser extent the horizontal long-axis, projections are best to visualize the RV for this purpose.
Early studies using rest and exercise radionuclide ventriculography demonstrated (1) that RV ischemia/dysfunction occurs in patients with CAD and/or heart failure (HF) and (2) that it has important independent prognostic value, an observation that has been more recently reconfirmed using other imaging modalities.4,5,6,7,8,9 The MBF to the RV myocardium is from the right coronary artery (RCA) in patients with right dominant coronary circulation. Therefore, it stands a good chance that patients with inferior LV ischemia are more likely to show RV ischemia, if that can be detected using SPECT imaging.10,11,12
In this proof-of-principle study, we used visual analysis, processing the images with filtered back projection as well as iterative reconstruction algorithms, and a specifically designed automated software to examine/quantify RV perfusion.
Method and Results
We identified 34 patients with abnormal perfusion in the inferior wall of the LV myocardium who underwent SPECT MPI at the University of Alabama at Birmingham from March to December 2015. All patients underwent stress-rest gated SPECT MPI using previously described methods and in accordance with ASNC guidelines.13,14,15,16 Briefly, all patients underwent same-day low-dose stress (10-15 mCi) followed by high-dose rest (30-35 mCi) imaging except for 1 patient who underwent a two-day high-dose stress and high-dose rest imaging protocol due to body habitus (body mass index of 38 kg/cm2). Gated SPECT images were acquired 1 hour after tracer injection with a dual-head detector gamma camera with a low-energy, high-resolution collimator with a 64 × 64 matrix. The cameras operated in an elliptical 180° acquisition orbit with 32 projections and 30 seconds per projection. For image acquisition, a 15% energy window focused on the 140-keV gamma peak was utilized. Gating was performed with 8-16 frames/RR cycle. No attenuation correction was used. The data are presented as mean ± SD or numbers and percentages when applicable. Student t test was used for comparison between the 2 groups.
All 34 patients had a perfusion abnormality in the inferior wall of the LV with and without reversible, fixed or mixed perfusion defects in other vascular territories. Of these patients, one-half had RV reversible perfusion defects defined as perfusion abnormalities in the RV free wall on the stress images with either absent or less severe abnormality on the rest images by visual analysis (Group 1, n = 17, Figure 1 top panel), while the others did not (Group 2, n = 17, Figure 2 left panel).
The baseline characteristics and medication use for both groups are listed in Table 1. Most patients were men and had one or more coronary risk factors or known CAD. Regadenoson was used in 2/3 and treadmill exercise in 1/3 of the patients, while one patient underwent dobutamine stress. The perfusion abnormality was reversible (with or without a fixed defect) in the majority of patients. The vascular distribution of LV perfusion abnormalities in both groups is shown in Table 1.
All images were processed twice, first using filtered back projection and then with iterative reconstruction. The images were then analyzed using a modified version of Cedars Sinai’s QPS+QGS automatic quantification software, version 2013.1. The images produced by both the processing methods were reviewed to assess which approach is superior in visualizing RV reversible perfusion defects. Although RV reversible perfusion defects were visible by both the processing methods in all the patients in group 1, filtered back projection was subjectively felt to be superior to iterative reconstruction in 75% of the patients, while iterative reconstruction appeared superior in the remaining 25%. We were not able to appreciate any obvious differences in the patients who demonstrated superiority of one processing algorithm over the other. Most of the RV perfusion defects appeared partially reversible (Figure 1).
Finally, a specifically designed modification to a standard automated software program, not previously described or used, was used to quantify RV reversible perfusion defect size (Figure 1, bottom panel, and Figure 2, right panel). This software segments the RV myocardium by combining the previously segmented LV septum, which is taken as a starting point, with the free wall myocardium, which is segmented using a version of the LV segmentation algorithm17 modified to account for RV geometry and count distributions. Reversible perfusion defect size is then computed by comparing stress and rest RV myocardial perfusion using a similarly modified version of a registration-based LV quantitation algorithm.18 Since the stress and rest images were acquired with different doses and at different times, an optimized normalization factor was used in the registration algorithm. Also, to avoid the influence of perfusion defects on registration, a 2-pass method was used as previously described for the LV18 By automated analysis, the size of the RV reversible perfusion defects was 19% ± 14% of RV myocardium (range 5%-33%).
Discussion
This proof-of-principle study shows that at least in some patients with CAD and inferior LV perfusion abnormality, a perfusion pattern suggestive of RV ischemia could be seen using technetium-labeled tracers and standard Anger gamma camera and software and quantitated using a novel software program. This is likely better than using thallium and may be improved further by means of newer cameras that utilize CZT detectors and advanced software processing algorithms including attenuation correction.16,19,20,21
The RV reversible perfusion defect pattern described in our report is different from that described by Williams and Schneider who observed increased RV:LV activity during exercise/rest dual isotope imaging and attributed it to severe CAD, particularly high-grade left main with less severe proximal right CAD.10
The prevalence of RV ischemia by MPI and its implications on prognosis were not addressed in this report and will need to be addressed in larger studies. Also, we did not have data from coronary angiography in our patients to correlate perfusion with anatomy. It is not clear whether RV ischemia could occur without inferior LV ischemia, but certainly disease location in the RCA proximal or distal to the RV and the acute marginal branches would suggest that it is possible.11,12 Whether isolated RV ischemia detected by MPI in the absence of inferior LV ischemia impacts prognosis should be evaluated in a larger study that recruits patients with multiple LV perfusion patterns and follows them over time for outcomes.
This feasibility study also suggests that automated quantification of perfusion defect size is possible, even though the geometric shape of the RV is difficult to model and ascertainment of the location of the pulmonic valve is not always straightforward. The automated software may help in more reproducible reading and avoid misinterpretation due to differences in geometry and scaling of the 2 sets of the images. Analogously to the LV, it should also be possible to develop normal limit databases for automated quantification of RV perfusion and function. Similar to LV,22,23 automated analysis of perfusion pattern should provide improved accuracy and reproducibility compared to visual analysis. In our report, we processed images using filtered back projection and iterative reconstruction and noted the superiority of filtered back projection for visualization of RV reversible perfusion defects in most but not all cases. It should be noted that this constituted a subjective evaluation that may differ from reader to reader (see Fig. 1 as typical example). Further, we stress that RV reversible perfusion defects were visible by using both processing algorithms in all patients. Although future studies may determine if processing may impact the visualization of RV perfusion, we suggest that the quantitative evaluation of the RV perfusion pattern, similar to the LV, should depend on automated softwares. In our cohort, the automated quantitation of the RV perfusion defect size was not significantly dependent on the processing method used (19 ± 4 by filtered back projection and 18 ± 14 by iterative reconstruction), further highlighting the subjectivity of the visual assessment.
It is possible that RV infarction may have contributed to the RV perfusion defect seen in some of our patients. Another possibility is that the perfusion pattern in the RV is artefactual due to the partial volume effect, the higher dose of radionuclide tracer in the rest study, and possible slight misalignment between images.1,16 We doubt if these factors accounted for perfusion pattern seen in the majority of our patients, but it is not possible to refute or prove this. Another contributing factor could be attenuation artifact due to body habitus since the majority of our patients were overweight. We have not used attenuation correction in this study and it is not possible to speculate on the effect of attenuation correction on RV from our study.
This study shows that RV ischemia can occur in some patients with CAD and may be detected by current imaging systems and software. It is likely that newer detectors will perform even better in this regards. More studies are needed to confirm these findings and explore their implications on patient care.
New Knowledge Gained
RV reversible perfusion defects suggestive of ischemia can be detected using SPECT MPI and quantitated using a novel automated software.
Abbreviations
- HF:
-
Heart failure
- RV:
-
Right ventricle/ventricular
- ROI:
-
Region of interest
- LV:
-
left ventricle/ventricular
- LAD:
-
Left anterior descending artery
- LCX:
-
Left circumflex coronary artery
- RCA:
-
Right coronary artery
- SPECT:
-
Single photon emission tomography
- MPI:
-
Myocardial perfusion imaging
- MBF:
-
myocardial blood flow
- CAD:
-
Coronary artery disease
- CABG:
-
Coronary artery bypass grafting
- PCI:
-
Percutaneous intervention
References
Kessler RM, Ellis JR Jr, Eden M. Analysis of emission tomographic scan data: Limitations imposed by resolution and background. J Comput Assist Tomogr 1984;8:514-22.
Gomez A, Bialostozky D, Zajarias A, Santos E, Palomar A, Martinez ML, et al. Right ventricular ischemia in patients with primary pulmonary hypertension. J Am Coll Cardiol 2001;38:1137-42.
Ohira H, Beanlands RS, Davies RA, Mielniczuk L. The role of nuclear imaging in pulmonary hypertension. J Nucl Cardiol 2015;22:141-57.
Manno BV, Iskandrian AS, Hakki AH. Right ventricular function: Methodologic and clinical considerations in noninvasive scintigraphic assessment. J Am Coll Cardiol 1984;3:1072-81.
Filippatos GS, Desai RV, Ahmed MI, Fonarow GC, Love TE, Aban IB, et al. Hypoalbuminaemia and incident heart failure in older adults. Eur J Heart Fail 2011;13:1078-86.
Kim J, Di Franco A, Seoane T, Srinivasan A, Kampaktsis PN, Geevarghese A, et al. Right ventricular dysfunction impairs effort tolerance independent of left ventricular function among patients undergoing exercise stress myocardial perfusion imaging. Circ Cardiovasc Imaging 2016. doi:10.1161/CIRCIMAGING.116.005115.
Rallidis LS, Makavos G, Nihoyannopoulos P. Right ventricular involvement in coronary artery disease: Role of echocardiography for diagnosis and prognosis. J Am Soc Echocardiogr 2014;27:223-9.
Sabe MA, Sabe SA, Kusunose K, Flamm SD, Griffin BP, Kwon DH. Predictors and prognostic significance of right ventricular ejection fraction in patients with ischemic cardiomyopathy. Circulation 2016;134:656-65.
Valsangiacomo Buechel ER, Mertens LL. Imaging the right heart: The use of integrated multimodality imaging. Eur Heart J 2012;33:949-60.
Williams KA, Schneider CM. Increased stress right ventricular activity on dual isotope perfusion SPECT: A sign of multivessel and/or left main coronary artery disease. J Am Coll Cardiol 1999;34:420-7.
Schofer J, Spielman R, Bleifeld W, Montz R, Mathey G. Scintigraphic evidence that the right ventricular myocardium tolerates ischaemia better than the left ventricular myocardium. Eur Heart J 1985;6:751-8.
Travin MI, Malkin RD, Garber CE, Messinger DE, Cloutier DJ, Heller GV. Prevalence of right ventricular perfusion defects after inferior myocardial infarction assessed by low-level exercise with technetium 99m sestamibi tomographic myocardial imaging. Am Heart J 1994;127:797-804.
Hage FG, Ghimire G, Lester D, McKay J, Bleich S, El-Hajj S, et al. The prognostic value of regadenoson myocardial perfusion imaging. J Nucl Cardiol 2015;22:1214-21.
Aggarwal H, AlJaroudi WA, Mehta S, Mannon R, Heo J, Iskandrian AE, et al. The prognostic value of left ventricular mechanical dyssynchrony using gated myocardial perfusion imaging in patients with end-stage renal disease. J Nucl Cardiol 2014;21:739-46.
Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol 2016;23:606-39.
Iskandrian AE, Garcia EV. Nuclear cardiac imaging: Principles and applications. 5th ed. Oxford: Oxford University Press; 2016.
Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47.
Slomka PJ, Nishina H, Berman DS, Kang X, Friedman JD, Hayes SW, et al. Automatic quantification of myocardial perfusion stress-rest change: A new measure of ischemia. J Nucl Med 2004;45:183-91.
DePuey EG, Jones ME, Garcia EV. Evaluation of right ventricular regional perfusion with technetium-99m-sestamibi SPECT. J Nucl Med 1991;32:1199-205.
Farag AA, Andrikopoulou E, Iskandrian AE, Germano G, Hage FG. Detection of right ventricular ischemia by SPECT myocardial perfusion imaging. J Nucl Cardiol 2017;24:317-8.
Chiba J, Takeishi Y, Abe S, Tomoike H. Visualisation of exercise-induced ischaemia of the right ventricle by thallium-201 single photon emission computed tomography. Heart 1997;77:40-5.
Iskandrian AE, Hage FG, Shaw LJ, Mahmarian JJ, Berman DS. Serial myocardial perfusion imaging: Defining a significant change and targeting management decisions. JACC Cardiovasc Imaging 2014;7:79-96.
El-Hajj S, AlJaroudi WA, Farag A, Bleich S, Manaoragada P, Iskandrian AE, et al. Effect of changes in perfusion defect size during serial regadenoson myocardial perfusion imaging on cardiovascular outcomes in high-risk patients. J Nucl Cardiol 2016;23:101-12.
Disclosure
Dr. Hage reports research grant support from Astellas Pharma. Some authors (GG, PBK) receive royalties from Cedars-Sinai Medical Center for algorithms incorporated in commercially distributed software that performs automatic quantification of perfusion, function and other cardiac parameters.
Author information
Authors and Affiliations
Corresponding author
Additional information
The authors of this article have provided a Power Point file, available for download at SpringerLink, which summarises the contents of the paper and is free for re-use at meetings and presentations. Search for the article DOI on SpringerLink.com.
All editorial decisions for this article, including selection of reviewers and the final decision, were made by guest editor Alberto Cuocolo, MD.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Farag, A.A., Heo, J., Tauxe, L. et al. Detection and quantitation of right ventricular reversible perfusion defects by stress SPECT myocardial perfusion imaging: A proof-of-principle study. J. Nucl. Cardiol. 26, 266–271 (2019). https://doi.org/10.1007/s12350-017-0954-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12350-017-0954-4