Abstract
Identifying contaminant sources in a precise and rapid manner is critical to indoor air quality (IAQ) management as disclosed source information can facilitate proper and effective IAQ controls in environments with airborne infection, fire smoke and chemical pollutant release etc. Probability-based inverse modeling method was shown feasible for locating single instantaneous source in IAQ events. To tackle more realistic sources of continuous release, this paper advances the method to identify continuously releasing single contaminant source. The study formulates a suite of inverse modeling algorithms that can promptly locate dynamic source with known release time for IAQ events. Two field experiments are employed to verify the prediction: one in a multi-room apartment and the other in a hospital ward which was involved in a SARS outbreak in Hong Kong in 2003. The developed algorithms promptly and accurately identify the source locations in both cases.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
ASHRAE (2009). Handbook of Fundamentals. Atlanta: American Society of Heating, Refrigeration, and Air-Conditioning Engineers.
Fisk WJ (2000). Health and productivity gains from better indoor environments and their relationship with energy efficiency. Annual Review of Energy and the Environment, 25: 537–566.
Karter MJ (2003). Fire loss in the United States during 2002. Fire Analysis & Research Division, National Fire Protection Association. http://www.nfpa.org/assets/files/pdf/OSfireloss02.pdf. Accessed on 1 Nov. 2007.
Li Y, Huang X, Yu ITS, Wong TW, Qian H (2004). Role of air distribution in SARS transmission during the largest. Indoor Air, 15: 83–95.
Liu X, Zhai Z (2007). Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals. Indoor Air, 17: 419–438.
Liu X, Zhai Z (2008). Location identification for indoor instantaneous point contaminant source by probability-based inverse computational fluid dynamics modeling. Indoor Air, 18: 2–11.
Liu X, Zhai Z (2009). Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling. Building and Environment, 44: 1135–1143
Neupauer RM (2000). Receptor based modeling of groundwater contamination. PhD dissertation, New Mexico Institute of Mining and Technology, USA.
Neupauer RM, Wilson JL (1999). Adjoint method for obtaining backward-in-time location and travel time probabilities of a conservative groundwater contaminant. Water Resources Research, 35: 3389–3398.
Neupauer RM, Wilson JL (2001). Adjoint-derived location and travel time probabilities for a multi-dimensional groundwater system. Water Resources Research, 37: 1657–1668.
WHO (2010). http://www.who.int/indoorair/health_impacts/burden_global/en/index.html.
Wikipedia (2011). http://http://en.wikipedia.org/wiki/Indoor_air_quality.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zhai, Z.(., Liu, X., Wang, H. et al. Experimental verification of tracking algorithm for dynamically-releasing single indoor contaminant. Build. Simul. 5, 5–14 (2012). https://doi.org/10.1007/s12273-011-0041-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12273-011-0041-8