Introduction

Fractures of the distal tibia can be challenging to treat because of the limited soft tissue, the subcutaneous location, and poor vascularity. The best treatment remains controversial. Nonsurgical treatment is possible for stable fractures with minimal shortening, but malunion, shortening of affected leg, limitation of range of motion, and early osteoarthritis of the ankle have all been reported following treatment of these fractures particularly pilon fractures [36, 40]. Surgical fixation of distal tibia fractures can be difficult, and requires careful preoperative planning. Fracture pattern, soft tissue injury, and bone quality critically influence the selection of fixation technique [2]. Several surgical methods have been described, including external fixation, intramedullary nailing, and plate fixation. External fixation can be useful in open fractures with soft tissue injury which preclude nail or plate fixation, but may result in inaccurate reduction [1, 4], a relatively high rate of malunion (range, 5%–25%) [8, 47] or nonunion (range, 2%–17.6%) [1, 32], and pin tract infection (range, 10%–100%) [4, 47]. In diaphyseal fractures of the tibia, intramedullary nailing allows relatively atraumatic closed stabilization. It preserves the vascularity of the fracture site and integrity of the soft tissue envelope [3]. However, stable intramedullary nailing of the distal tibia may be difficult to achieve because the hourglass shape of the intramedullary canal prevents a tight endosteal fit and compromises torsional and angular stability [9]. Secondary displacement of the fracture on insertion of the nail, breakage of nails and locking screws (range, 5%–59%) [28], and malunion of the tibia (range, 0–29%) [10, 34] are potential risks. Classic open reduction and internal plate fixation require extensive soft tissue dissection and periosteal stripping even in expert hands, with high rates of complications, including infection (range, 8.3%–23%) [24, 26] and delayed union and nonunions (range, 8.3%–35%) [6, 24, 26, 46, 48]. Several minimally invasive plate osteosynthesis techniques have been developed, with union rates ranging between 80% and 100% [14, 21, 31, 44]. These techniques aim to reduce surgical trauma and to maintain a more biologically favorable environment for fracture healing. Nevertheless, complications, such as angular deformities greater than 7° (range, 7.1%–35%) [31, 46], hardware failure (range, 0–10%) [27, 31], and nonunions (range, 0–20%) [14, 21] have been reported.

A new advance in this field is represented by the “locked internal fixators.” These devices consist of plate-and-screw systems where the screws are locked in the plate at a fixed angle. Screw locking minimizes the compressive forces exerted by the plate on the bone because the plate does not need to be tightly pressed against the bone to stabilize the fracture. The claim of minimizing disturbance of the bone blood supply [13, 16, 17, 37] will require future confirmation. The system works as flexible elastic fixation that putatively stimulates callus formation. The anatomical shape prevents primary displacement of the fracture caused by inexact contouring of a normal plate, and allows a better distribution of the angular and axial loading around the plate [16, 17]. These biomechanical advantages as contrasted to other approaches have not been confirmed in clinical followup studies.

We therefore assessed the union rate, deformity, leg-length discrepancy, gait and ankle range of motion, return to preinjury daily and sports activities, and infections and other complications. We compared our results with those reported by other authors using the same technique to evaluate whether the LCP is a suitable device for surgical management of distal tibia fractures.

Patients and Methods

We retrospectively analyzed prospectively collected data on 21 adult patients with closed distal tibia and fibula fractures without previous or present ipsilateral leg fracture treated from 2003 to 2006. We excluded patients with pathological fractures, lower limbs with preexisting neurological deficit, autoimmune disease, or vascular disease. Five patients sustained their fracture as a result of a fall, 10 in a motor vehicle accident, and six during sports activities (three soccer, one rugby, one running, one mountain biking). Seven patients were smokers. None had a polytrauma or an open fracture. Depending on the skin condition, surgery was planned when the ankle swelling subsided, and the “wrinkle sign” was present. In the wrinkle sign, the ankle is dorsiflexed while the anterior aspect of the ankle is observed; the absence of a skin crease or wrinkle suggests severe swelling [45]. The time between trauma and surgery was 6.5 ± 4.3 days (range, 5–14 days). There were nine women and 12 men, ranging in age from 25 to 66 years (mean age for all patients, 43 ± 7 years; mean age, men, 42 ± 12 years, age range, men, 26–66 years; mean age, women, 44 ± 7 years, range, women, 25–65 years). In all patients, the distal tibia was affected. In 17 of 21 patients, the fibula was fractured as well. The minimum followup was 2 years (average, 2.8; range, 2–4 years) after surgery. Two patients were lost to final followup, but their fracture was clinically and radiographically healed at 9 months, and they had returned to their work. They had not returned to their leisure activities. These two patients were not included in the final evaluation, leaving 19 patients for evaluation. All the procedures described in this investigation were approved by our local ethics committee. All the patients gave written informed consent to be included in the present study.

All patients had plain radiographs. We obtained CT scans in 9 patients with extension of the fracture to the joint. All the fractures were evaluated by the surgeon (NM) and classified according to the AO comprehensive classification system [35]. The AO classification arose from efforts to produce a comprehensive system for fractures of the long bones. The distal segment of the tibia is classified as ‘43’ and divided into three types as follows: Type A, extraarticular fractures; Type B, partial articular fractures, which maintain some continuity between the shaft and the articular surface; and Type C, complete articular fractures. There were 12 AO 43A fractures, 5 AO 43B fractures, and 4 AO 43C fractures.

Immediate skeletal stabilization was achieved by splints with an above-knee back slab or a spanning external fixator in nine instances. All procedures were performed by a single surgeon (NM) with a special interest in these techniques using a previously described approach [41]. Briefly, with the patient supine on a radiolucent table, antibiotic prophylaxis was administered (cefuroxime, 1.5 g intravenously) and standard intraoperative fluoroscopy used throughout the procedure. Both the injured and the noninjured limb were prepped and draped above the knee, thus allowing intraoperative alignment to be checked against the normal limb. The joint line of both the knee and the ankle was identified with fluoroscopy control and marked on the skin. Using manual traction at the ankle or through a single Steinmann pin inserted into the calcaneus, the fracture was gently reduced, restoring limb length, alignment, and rotation (Fig. 1A). Most often, we internally fixed the tibial fracture first when a fibular fracture was present. However, if normal length, axis, and rotation of the tibial fracture were not achieved, a fibula fracture, if present, was plated first using a one-third tubular plate to provide lateral stability, restore the correct length, and avoid overdistraction at the tibial fracture site. Thus, in two patients we first stabilized the fibula using a one-third tubular plate. In seven patients, accurate reduction and stable fixation of the fibular fracture was achieved after tibial fixation using a minimally invasive approach. In the five patients in whom reduction and/or stable fixation of the fibula was not possible using a minimally invasive approach, we converted the fixation of the fibular fracture to an open method. In the other three patients in whom the fibula was fractured, this was internally fixed after minimally invasive fixation of the tibial fracture having planned an open approach from the start. The main fracture fragments of the distal tibia were aligned and reduced percutaneously or through separate stab incisions using a periosteal elevator, clamps, or Kirschner wires as joysticks, and then fixed with individual lag screws. In the four patients with fractures with intraarticular extension in whom we thought that a combined approach would have been helpful, we performed arthroscopy through conventional anteromedial and anterolateral portals to assess the reduction of the articular surface and to address any associated joint lesions. At arthroscopy, we found loose bodies or chondral defects in three of these patients. The loose bodies were removed, and the chondral defects were débrided. A transverse incision about 1 cm distal to the medial malleolus was performed in 13 patients. The transverse incision remained in the superficial subcutaneous layers, and did not penetrate the sheath of the tendon of tibialis posterior. In the remaining eight patients, we used a longitudinal incision over the medial malleolus. A subcutaneous tunnel was produced using forceps (Fig. 1B) or a periosteum elevator. Following appropriate reduction of the fracture, a locking compression plate-distal tibial plate (LCP-DTP, Synthes, Stratec Medical, Oberdorf, Switzerland) is inserted to bridge the fracture site. We chose a plate long enough to bridge the metaphyseal zone and allow the insertion of at least two bicortical screws insertions proximal to the fracture. More than two screws in each fracture fragment may cause increased stress at the plate for small bridging lengths and small fracture gap sizes [43]. On the other hand, additional screws increase the implant stress since higher loads are needed to achieve bone contact in tibial fractures [43].

Fig. 1A–C
figure 1

(A) A calcaneal Steinmann pin is applied to reduce the fracture and to maintain the length and alignment of the limb. Small longitudinal incision is distal to the medial malleolus (arrow). (B) Through the small incision, the subcutaneous tunnel is created using an artery forceps. (C) Final scars (arrows) show the minimal nature of the exposure.

Distal to the metaphyseal fracture, we inserted bicortical or unicortical screws using as many of the distal plate holes as possible (maximum, nine holes). We used Kirschner wires to secure, through holes of the plate, the latter to the bone before screw insertion. At this stage, we assessed limb alignment by comparison with the other limb. We established the correct rotation evaluating the alignment of the proximal and distal cortices of the distal tibia and comparing at 90° of knee flexion the axis between the tibial tuberosity and the intermetatarsal spaces. Screws were then inserted percutaneously through stab wounds as necessary. The ratio between screws inserted and holes used was 0.65 (range, 0.6–0.8). The screening radiation time was 81.3 ± 33.4 seconds (range, 41–118 seconds). The stab incisions were irrigated and closed with routine skin sutures, the wound dressed. The mean hospital stay was 11.4 days (range, 6–22 days).

All limbs were immobilized in a below-knee synthetic cast for 6 weeks. The patients who had previous external fixation received two other doses of prophylactic antibiotics (cefuroxime, 1.5 g intravenously), one 8 hours and another 16 hours after the dose at induction. We did not routinely use postoperative venous thromboembolism prevention, except for the two patients who were already on anticoagulant drugs for underlying comorbidities. We instituted non-weight bearing crutch walking while still in hospital, following recovery from the anesthesia. At 2 weeks, we changed the below-knee synthetic cast to another short-leg lightweight cast after inspection of the wound and removal of the sutures (Fig. 1C). The weight-bearing status was dependent on the individual fracture pattern, but most patients could at least partially weight bear at 6 weeks. If the fracture was intraarticular, we kept the patients non-weight bearing for the first 2 weeks, and asked them to start toe-touch weight bearing starting from the 4th postoperative week. Outpatient physiotherapy was instituted to maximize the range of motion of the foot and ankle immediately after definitive removal of the cast.

We scheduled clinical, functional, and radiographic (plain anteroposterior and lateral radiographs) evaluations at 6, 12, 24 weeks, 1 year from the index procedure, and then annually. All the evaluations were performed by the surgeon. The functional outcomes were based on four parameters: substantial limp, range of motion of the ankle, inactivity (unemployment because of the leg injury or inability to return to daily activities because of the leg injury), infection, and complication rate. We defined a late skin infection as one that occurred at least 2 months after complete wound healing.

We evaluated three radiographic parameters: union (bridging of at least three of four cortices on two orthogonal views), deformity (< 7°), and leg-length discrepancy (< 2.5 cm in the tibia) on standard long-leg radiographs. We considered a healing time less than 6 months normal and between 6 and 9 months as a delayed union. Fractures not healed within 9 months were considered a nonunion according to the 1988 FDA guidance document definition for tibial fracture, requiring 9 months duration of the nonunited fracture with no evidence of progressive healing over the previous 3 months [15, 18].

Results

Union was achieved in all but one of the 21 patients by the 24th postoperative week, with one patient being classified as a nonunion (Figs. 2A–D and 3A–B) (Table 1). The one patient with a nonunion is still undergoing nonoperative treatment, as he does not wish to undergo a further operation. Four patients (21%) had angular deformities, all less than 7°: one patient had a valgus deformity; three patients had a varus deformity, and two of these four patients had anterior bowing (6° and 7° respectively) of the tibia at the fracture site. No patient had a leg-length discrepancy greater than 1.1 cm.

Fig. 2A–D
figure 2

(A) AO 43 B fracture, (B) postoperative radiographs, (C) 6-month followup, and (D) clinical appearance after 6 months are shown. The patient is fully weight bearing with no walking aids and no limp. Note the well-healed, barely visible scars.

Fig. 3A–B
figure 3

(A) AO 43 C fracture and (B) plain radiographs after 1 year are shown. The fracture united with no limb shortening and the patient reports no use of walking aids and no limp.

Table 1 Overall results according bone and functional parameters

At the last followup, eight of the 19 patients (excluding the two lost to followup) had a limp, but none of them used walking aids. The range of motion of the ankle was reduced more than 20° compared with the contralateral side in five patients. In six patients, the plate was palpable in the subcutaneous tissues at the time of the latest clinic visit, but did not produce any discomfort that interfered with the patients’ daily activities. Sixteen of the 19 patients had not returned to their preinjury sporting or leisure activities.

The wounds healed without further wound problems in 12 of the 21 patients (Fig. 1C). Three patients developed a late infection around the proximal or distal screws 13, 15, and 17 weeks, respectively, after the index operation. None of these three infections resolved with local wound care and 6 weeks of oral antibiotics and we therefore removed the tibial locked plate at 6, 7, and 8 months, respectively, from the original operation. Two of these three patients had undergone transient external fixation for less than 10 days before definitive fixation. Six patients experienced minor wound dehiscence or superficial cellulitis within 3 months of the index operation, and were treated with local wound care and oral antibiotics (500 mg of flucloxacyllin four times a day for 7 days); the wound problems resolved in all six patients. One female patient developed complex regional pain syndrome that was managed with intensive rehabilitation and resolved after 9 months. Four patients (21%) reported deep venous thrombosis between 4 and 6 weeks after surgery, and were managed with oral anticoagulants for 3 months with no adverse effects. There were no complications related to the arthroscopic approach.

Discussion

The treatment of distal tibia fractures can be challenging because of the limited soft tissue, the subcutaneous location of the bone, and poor vascularity. Minimally invasive plating techniques reduce iatrogenic soft tissue injury and damage to bone vascularity, as well as preserve the osteogenic fracture hematoma [11, 12]. Initial clinical series using these methods demonstrated favorable results with low rates of infection and nonunion [7, 21, 31, 39], but several complications such as angular deformities greater than 7° and hardware failure have been reported [14, 21, 31]. Locking plates have been developed to overcome these limits. We therefore evaluated a selected group of patients with closed distal tibia fracture, the bone union rate, deformity, leg-length discrepancy, range of motion of the ankle, return to preinjury daily and sports activities, and infection or other complications rate after locking plating.

Our study presents several limitations. First, the relatively small number of patients and the lack of a control group do not allow the formulation of definitive statements and guidelines. As closed distal tibial fractures are uncommon, it would be difficult for a single hospital to collect a large enough number of patients to perform a randomized study. Several authors using locking tibial plates reported, in series of between 20 and 48 patients, a percentage of open fracture of 19% to 40% [7, 1921, 29]. Second, our cohort involves both intraarticular and extraarticular fractures, all managed in a standard fashion. Unfortunately, the numbers involved are too small to allow meaningful subcohort comparisons.

We used distal tibial locking plates (LCP-DTP) instead of metaphyseal locking plates (LCP-MP) because LCP-DTP afford better control strain during neutral (decreased 39%–47% versus 6.4%–41.5%), flexion (increased 0.2%–18% versus 34%–109%), and extension (increased 13%–21% versus 25%–60%) moments [42]. Also, the LCP-DTP has greater versatility to insert distal screws, with has nine distal holes instead of the four holes of the LCP-MP, allowing more precise modulation of the rigidity of fixation [42]. Borg et al. reported as a limitation of the conventional low contact plate the number of screws that can be placed in a short distal fragment [5].

The percentage of union, delayed union, and nonunion is comparable to studies that included only patients with closed fracture [5, 39]. Three preliminary retrospective studies using an LCP-DTP to manage closed and open distal tibia fractures reported a union rate similar to our study (range, 90%–100%) (Table 2) [7, 19, 20]. However, two of these three studies reported several supplementary procedures (range, 2–9 procedures) performed to obtain union.

Table 2 Clinical series of distal tibia fractures treated with percutaneous LCP-DTP

No patients had angular deformities greater than 7° or leg discrepancy greater than 1.1 cm, although we acknowledge that two of four patients each had deformities in two planes. This result can be attributed to the experience of the surgeon, to the contour of the anatomic plate, and to the fixed angle stability of the holes. These findings are comparable to other studies using an LCP-DTP (Table 2) [7, 19, 20]. Before fixing the plate, given the possibility of a discrepancy between the anatomical axis of the tibia and the contour of the plate, we assessed limb alignment by comparison with the other limb. Then we inserted Kirschner wires through the holes of the plate to secure the latter to the bone before screw insertion. The fixed angle stability of the holes avoids the need of tightly pressing the plate against the bone to stabilize the fracture. This prevents primary dislocation of the fracture caused by inexact contouring of a plate. In a previous study, the same surgeon (NM), using a dynamic compression plate precontoured before undertaking the procedure, reported that seven of 20 patients (35%) had angular deformities greater than 7° [31]. The design of the implant is also important. The LC-DCP has a better fatigue resistance than earlier AO plates [38]. These mechanical properties of the LC-DCP may be the reason why no plates broke in this series compared to previous studies (2.7%–10% of the plates) [14, 31, 46]. However, in the other three studies using an LCP-DTP there were two cases of plate breakage and one case of plate bending. One of the two plate failures involved a man with diabetic neuropathy and questionable compliance whose plate broke 4 months after injury while excessive weight bearing determined the plate bending of more than 18° [7, 19].

Five patients (26%) experienced restriction in ankle motion greater than 20° and 16 patients (84%) had not returned to their preinjury sporting or leisure activities. We cannot be certain that no problems related to ankle osteoarthritis will arise in the future in patients with intraarticular involvement who reported satisfactory functional and radiographic results. However, Collinge et al. reported the only variable that influenced functional outcomes was the occurrence of a secondary surgery (34% of patients), which was associated with poorer function results [7]. Associated lower-extremity fracture, other injuries, intraarticular extension, bone loss, open fracture, or the time to union were not associated with poorer function on limb-specific assessments.

We identified late infections in three patients. This complication was also observed by other authors using the same plates, and was attributed to the possible plate prominence in the distal region of the tibia rather than to open fractures (Table 2) [7, 19, 20]. In our patients, bone healing was not affected by the infection. The resistance to superficial infection and good bony union rate may be due to the preservation of bony vascularity with the use of the minimally invasive technique [29].

The arthroscopic approach allows visualization of the reduction of the articular surface, to assess and to treat any joint lesions. Several authors reported an incidence of intraarticular pathology in ankle fractures ranging between 63% and 79.2% [22, 30]. Based on the minimal added time and morbidity to the surgical procedure, we use arthroscopy on a regular basis in intraarticular fractures [23, 25, 33].

Given the small numbers of patients in our study, we cannot draw any definitive conclusions. The high percentage of unions and the low rate of complications, comparable to previous studies using the same plates, suggest the LCP-DTP may be a reasonable alternative for treating distal tibia fractures. The cost of the locking plates, the technically demanding nature of the procedure, and the increased exposure to radiation during the procedure should be considered when comparing the efficacy of this device to the normal plates. Only future prospective randomized studies may be able to clarify these issues.