Abstract
Pulsating heat pipes (PHPs) are two-phase heat transfer heat pipes with high heat transfer capability and simple structure. Heating power is an important factor that affects the start-up response characteristics of PHPs. The operational characteristics during the start-up and stable operating stages were studied through experiments, and the corresponding dynamic response model under a specified heating power was established based on experimental data and flow pattern in the tube. The starting time, starting temperature, and dynamic response characteristic parameters at a certain heating power were calculated by the dynamic response model. The response characteristics of working fluid during the stable operation of PHPs were deduced based on the dynamic response curve of PHPs during the non-operational and stable operation stages. The response characteristics of PHPs for the step effect (given heating power) were quantitatively described by amplification factor K and time constant τ, thereby presenting the basis for the study on heat and mass transfer mechanisms of PHPs from non-operational to steady operation stage. Results showed that the minimum thermal resistance and the minimum time constant of the PHP are approximately 0.28 °C/W and 75, respectively, obtained at a heating power of 160 W. Moreover, these results indicated that the dynamic response of PHPs demonstrates a favourable performance and rapidly reaches another stable working state when their heat transfer performance is stable. However, the dynamic response time constant of pure fluids decreases when the quantity of the liquid working fluid in the PHP decreases with the increase in heating power.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Akachi H., Structure of a heat pipe, US Patent 4921041, 1990.
Akachi H., Polasek F., Stulc P., Pulsating heat pipes. Proceedings of the 5th International Heat Pipe Symposium, Australia, 1996.
Hua C., Wang X., Gao X., Zheng H., Han X., and Chen G., Experimental research on the start-up characteristics and heat transfer performance of pulsating heat pipes with rectangular channels. Applied Thermal Engineering, 2017, 126: 1058–1062.
Dang C., Jia L., Lu Q., Investigation on thermal design of a rack with the pulsating heat pipe for cooling cpus. Applied Thermal Engineering, 2016, 110: 390–398.
Zhu Y., Cui X., Han H., Sun S., The study on the difference of the start-up and heat-transfer performance of the pulsating heat pipe with water-acetone mixtures. International Journal of Heat & Mass Transfer, 2014, 77(4): 834–842.
Li M., Huang R., Xu D., and Li L., Theoretical analysis of start-up power in helium pulsating heat pipe. IOP Conference Series: Materials Science and Engineering, 2017, 171 (1): 012102.
Hu C., Jia L., Experimental study on the start up performance of flat plate pulsating heat pipe. Journal of Thermal Science, 2011, 20(2): 150–154.
Wang X., Li Y.Y., Start-up characteristic of pulsating heat pipe with aqueous methanol as working fluid. Chemical Engineering, 2017, 45(6): 17–21.
Yang K.S., Cheng Y.C., Liu M.C., Shyu, J.C., Micro pulsating heat pipes with alternate microchannel widths. Applied Thermal Engineering, 2015, 83: 131–138.
Zou J., Yang H.H., Fang H.Z., Zhou B., Study on the Start-up Characteristics of Closed Loop Pulsating Heat Pipes Under Forced Cooling. Fluid Machinery, 2014, 10: 64–68.
Liu X., Chen Y., Shi M., Dynamic performance analysis on start-up of closed-loop pulsating heat pipes (clphps). International Journal of Thermal Sciences, 2013, 65: 224–233.
Xue Z.H., Chen S.Y., Qu W., Study on Visual Start-up and Heat Transfer Performance of Ammonia Pulsating Heat Pipe. Science China Technological Sciences, 2015, 45(9): 999–1006.
Tong B.Y., Wong T.N., Ooi K.T., Closed-loop pulsating heat pipe. Applied Thermal Engineering, 2001, 21(18): 1845–1862.
Katauhiko K., Morifum T., Explosive in two phase closed thermosyphons with and without a non-violatile liquid. 11th International Heat Pipe Conference, Tokyo, 1999.
Han X., Wang X., Zheng H., Xu X., Chen G., Review of the development of pulsating heat pipe for heat dissipation. Renewable & Sustainable Energy Reviews, 2016, 59: 692–709.
Kwon G.H., Kim S.J., Operational characteristics of pulsating heat pipes with a dual-diameter tube. International Journal of Heat & Mass Transfer, 2014, 75(7): 184–195.
Sarangi R.K., Rane M.V., Experimental investigations for start-up and maximum heat load of closed loop pulsating heat pipe. Procedia Engineering, 2013, 51: 683–687.
Nikolayev V.S., Effect of tube heat conduction on the single branch pulsating heat pipe start-up. International Journal of Heat & Mass Transfer, 2016, 95: 477–487.
Wang X., Jia L., Experimental study on heat transfer performance of pulsating heat pipe with refrigerants. Journal of Thermal Science, 2016, 25(5): 449–453.
Li J., Yan L., Experimental research on heat transfer of pulsating heat pipe. Journal of Thermal Science, 2008, 17(2): 181–185.
Acknowledgement
This study is financially supported by the National Natural Science Foundation of China (Grant No. 51506004), Beijing Municipal Natural Science Foundation (Grant No. 3162009), Scientific Research Project of Beijing Educational Committee (Grant No. KM201410016001), Beijing Youth Top-notch Talent Support Program, Science and Technology Project of Beijing (Grant No. Z171100000517007) and Fundamental Research Fund of Beijing University of Civil Engineering and Architecture (X18101).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xu, R., Chen, H., Wu, Q. et al. Testing and Modeling of the Dynamic Response Characteristics of Pulsating Heat Pipes during the Start-up Process. J. Therm. Sci. 28, 72–81 (2019). https://doi.org/10.1007/s11630-018-1032-1
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11630-018-1032-1