Abstract
A novel carbon paste electrode (CPE) modified with 2,2′-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHB) and carbon nanotubes (CNTs) was prepared. At first, the redox properties of the modified electrode were studied by cyclic voltammetry (CV). Then, the modified electrode was used as an electrochemical sensor for oxidation of captopril (CAP). Under the optimum pH of 7.0, the overpotential of CAP oxidation decreases about 120 mV at modified electrode than unmodified CPE. Differential pulse voltammetry (DPV) of CAP at the electrochemical sensor exhibited two linear dynamic ranges (7.0–100.0 and 100.0–2,500.0 μM) with a detection limit (3σ) of 2.43 μM. DPV was used for determination of CAP in the presence of acetaminophen (AC) and tryptophan (Trp), CAP in the presence of folic acid (FA), and CAP in the presence of l-cysteine (l-Cys) by the electrochemical sensor. The proposed electrochemical sensor was used for the determination of these substances in real sample.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Among the application of nanomaterials, carbon nanotubes (CNTs) have become the subject of intense investigation since their discovery in 1991 by Iijma [1]. The electrochemical methods using chemically modified electrodes (CMEs) have been widely used as sensitive and selective analytical methods for the detection of the trace amounts of biologically important compounds [2–5]. One of the most important properties of CMEs has been their ability to catalyze the electrode process via significant decreasing of overpotential respect to unmodified electrodes. Recently, there has been an increasing demand for more sensitive and simple analytical methods. Voltammetric techniques are very useful and popular for trace analysis, since these techniques are compact, efficient, and sensitive [6–11]. However, some authors have emphasized the instability of the attached materials on the electrodes as a problem arising in the utilization of chemically modified electrodes. It seems that the incorporation of electrocatalysts into the electrode matrix can, even partly, help to solve these problems, and carbon paste electrodes (CPEs) spiked with catalyst may be suitable for this purpose. The ease and speed of preparation and obtaining a new reproducible surface, the low residual current, porous surface, and low cost are some advantages of chemically modified carbon paste electrodes [12].
Captopril (CAP) with the chemical name of (2S)-1-[(2S)-2- methyl-3-sulfanylpropanoyl] pyrrolidine-2-carboxylic acid is an angiotensin-converting enzyme inhibitor (ACE inhibitor) and has been widely used as antihypertensive drug. CAP is used to treat high blood pressure and heart failure [13]. It decreases certain chemicals that tighten the blood vessels, so blood flows more smoothly and the heart can pump blood more efficiently. Serious toxicity has occurred primarily when CAP was given in high doses to patients with collagen vascular disease or renal insufficiency. Minor toxic effects which are seen include altered sense of taste, allergic skin rashes, and drug fever [14]. Various instrumental methods have been developed for the determination of captopril including HPLC [15], spectrophotometry [16], and chemiluminescence methods [17]. Nevertheless, these methods often have diverse disadvantages such as high cost, low selectivity, the use of organic solvents, complex sample preparation procedures, or long analysis time. In contrast, electrochemical methods can offer several advantages, for example, an inexpensive and simple analytical method with remarkable detection sensitivity, reproducibility, and ease of miniaturization [18–24]; they have been used in a wide range of important applications in clinical, industrial, environmental, and agricultural analyses [25–39]. Also, they are superior for use in the analytical determination of captopril [40–43].
Acetaminophen (AC) is categorized as analgesics (pain relievers) and antipyretics (fever reducers). When used appropriately, side effects are rare. The most serious side effect is liver damage due to large doses, chronic use, or concomitant use with alcohol or other drugs. AC is electroactive, and can be oxidized under certain conditions. Therefore, different electrochemical methods using various modified electrodes have also been proposed for the determination of AC [4, 44].
Tryptophan (Trp) is an essential amino acid, meaning that humans must consume it in their diet to survive. This compound is a precursor for the important biological molecules serotonin (a neurotransmitter), melatonin (a neurohormone), and niacin. It has also been implicated as a possible cause of schizophrenia in people who cannot metabolize it properly. When improperly metabolized, it creates a byproduct in the brain that is toxic, causing hallucination and delusions. Due to its low abundance in vegetables, this compound is sometimes added to staple food products and pharmaceutical formulas [45]. The electroanalytical methods, with respect to their sensitivity, accuracy, lower cost, and simplicity, have been more attractive in recent years for Trp determination [46, 47].
l-cysteine (l-Cys) is an important thio-containing amino acid involved in a variety of important cellular functions, such as protein synthesis, detoxification, and metabolism [48]. It has been also used as a radioprotective agent, cancer indicator, and is implicated in a number of pathological conditions, including Alzheimer’s and Parkinson’s diseases as well as autoimmune deficiency syndrome [49]. On the other hand, a deficiency of l-Cys causes many diseases, such as slowed growth in children, depigmentation of hair, edema, lethargy, liver damage, loss of muscle and fat, skin lesion, and weakness. Therefore, a sensitive and selective assessment of l-Cys in biological matrices and pharmaceutical preparations is highly demanded. The responses to thiol oxidation at unmodified electrodes usually suffer from large overpotentials or sluggish electrochemical responses [50]. The chemical modification of inert substrate electrodes with mediators offers significant advantages in the design and development of l-Cys electrochemical sensors. Therefore, biochemists and electroanalytical chemists have shown great interest in the area of modified electrodes to overcome these problems, and various modified electrodes have been constructed for this purpose [51].
Similarly, folic acid (FA) is an important component of the hematopoietic system and is the coenzyme that controls the generation of ferroheme. Lack of FA gives rise to gigantocytic anemia and is associated with leucopenia, devolution of mentality, and psychosis. Determination of FA is often required in pharmaceutical, clinical, and food samples [52].
According to the above points, we used new carbon paste electrode modified with 2,2′-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHB) and CNTs and investigate its performance for the electrocatalytic determination of CAP in the presence of AC and Trp, CAP in the presence of FA, and CAP in the presence of l-Cys. The experimental results indicate that modified electrode offers several advantages such as good stability, fast response, low detection limit, large dynamic range, good selectivity, and high apparent charge transfer rate constant. Utilizing the developed method, determination of these compounds has been carried out in human blood serum samples.
Experimental
Apparatus and chemicals
Electrochemical measurements were performed with a potentiostat/galvanostat (SAMA 500, electroanalyzer, system, IR. Iran). All experiments were carried out in a three-electrode cell at room temperature with DHB/CNT/CPE, SCE electrode, and a platinum wire as the working, reference, and counter electrodes, respectively (reference and auxiliary electrodes from AZAR electrode, Iran). All solutions were freshly prepared with doubly-distilled water. CAP, AC, Trp, FA, l-Cys, and all other reagents were analytical grade from Sigma-Aldrich. The graphite powder and paraffin oil (DC 0, 0.88 g cm−3), both from Merck (Darmstadt, Germany), were used as received. Multiwalled carbon nanotubes (purity more than 95 %) with o.d. between 5 and 20 nm, i.d. between 2 and 6 nm, and tube length 1–10 lm were purchased from plasma Chem (Germany). Phosphate buffers were prepared from orthophosphoric acid, and its salts and pH values were measured using a Metrohm 691 pH meter.
A typical procedure for synthesis of 2,2′-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol)
To a mixture of 2,5-dihydroxybenzaldehyde (0.35 g, 2.5 mmol) in MeOH was added 1,7-diaminoheptane (0.18 g, 1.4 mmol) and stirring for 30 min. The progress of the reaction was monitored by TLC. After the reaction completion, yellow solid product was filtered off and washed with cold MeOH, and pure Schiff base, 2,2′-[1,7–heptanediyl bis(nitrilomethylidene)]-bis(4-hydroxyphenol) was obtained in 90 % yield, m.p. = 215–217 °C. The Schiff base product was identified by physical and spectroscopic data as follows:
2,2′-[1,7–heptanediyl-bis(nitrilomethylidene)]-bis(4-hydroxyphenol): yellow solid; yield: 90 %; M.p: 215–217 °C. Anal. Calcd.: C, 68.1; H, 7.02; N, 7.6. Found: C, 68.1; H, 6.9; N, 7.4. IR (KBr)/υ(cm−1): 3,373–3,500 (s, br, 2OH), 1,646 (s, C = N), 1,503, 1,457 (Ar), 1,239 (s, C-O). 1H NMR (400 MHz/DMSO-d6)/δ ppm: 12.7 (br, 2OH, intramolecular hydrogen bonding), 8.90 (br, 2OH), 8.42 (s, 2CH Imine), 6.78 (d, 2H, Ar, J = 4 Hz), 6.76 (dd, 2H, Ar, J 1 = 8.2 Hz, J 2 = 2.2 Hz), 6.69 (d, 2H, Ar, J = 8.4 Hz), 3.54 (t, 4H, 2CH2, J = 12.8Hz), 1.58 (m, 8H, 4CH2), 1.33 (m, 2H, CH2). 13C NMR(100 MHz/DMSO-d6)/δ ppm: 165.77, 153.62, 149.70, 120.12, 119.01, 117.25, 116.90, 59.02, 30.83, 28.88, 27.03. MS: m/z = 370 (M+, 4), 235 (6), 220 (22), 206 (28), 193 (90), 179 (32), 150 (68), 137 (92), 126(100). UV/λmax: 340 (s), 240 (w).
Preparation of the electrode
The DHB/CNT/CPE were prepared by hand mixing 0.01 g of DHB with 0.96 g graphite powder and 0.03 g carbon nanotube particles with a mortar and pestle, Then ∼0.7 mL of paraffin was added to the above mixture and mixed for 20 min until a uniformly wetted paste was obtained. The paste was then packed into the end of a glass tube (ca. 3.7 mm i.d. and 10 cm long). A copper wire inserted into the carbon paste provided the electrical contact. When necessary, a new surface was obtained by pushing an excess of the paste. Out of the tube and polishing with a weighing paper for comparison, modified CPE electrode (DHB/CPE) without CNTs, CNT paste electrode (CNT/CPE) without DHB, and unmodified CPE in the absence of both DHB and CNT were also prepared in the same way.
Results and discussion
Chemistry of DHB/CNT/CPE
One of the advantages of DHB as a modifier is its insolubility in aqueous media. Therefore, we prepared DHB/CNT/CPE and studied its electrochemical properties in phosphate buffer solution (pH 7.0) using CV (Fig. 1). Since the DHB is insoluble in aqueous solution, we investigated its electrochemical behavior by carbon paste electrode. Experimental results showed reproducible, well-defined, anodic, and cathodic peaks with Epa = 0.283 V and Epc = 0.182 versus SCE. The observed peak separation potential, ∆Ep = (Epa-Epc) of 101 mV, was greater than the value of 59/n mV expected for a reversible system [53], suggesting that the redox couple of DHB in DHB/CNT/CPE has a quasi-reversible behavior in aqueous medium. The effect of the potential scan rate (υ) on electrochemical properties of the DHB/CNT/CPE was also studied by CV. Plots of the both anodic and cathodic peak currents (Ip) were linearly dependent on υ in the range of 20–1,600 mV s−1 (Fig. 1a), indicating that the redox process of DHB at the modified electrode is diffusionless in nature [53].
The apparent charge transfer rate constant, ks, and the transfer coefficient, α, of a surface-confined redox couple can be evaluated from CV experiments by using the variation of anodic and cathodic peak potentials with logarithm of scan rate, according to the procedure of Laviron (1979). Figure 1b, c shows the variations of peak potentials (Ep) as a function of the logarithm of the potential scan rate at scan rates and high scan rates, respectively. As can be seen at high scan rates, these plots become linear. The slopes of these linear segments in Fig. 1c can be used to extract the kinetic parameters αc and αa (cathodic and anodic transfer coefficients, respectively). The slope of the linear segments are equal to –2.303RT/αnF and 2.303RT/(1 – α)nF for the cathodic and anodic peaks, respectively. The evaluated value for the αa is 0.32.
The Laviron equation can be used to gain the electron transfer rate constant for the case of surface-confined electroactive species with a concentration small enough [54].
So, the value of apparent charge transfer rate constant (ks) 5.70 s−1 were calculated for the DHB/CNT/CPE at 0.1 M phosphate buffer.
An approximate estimate of the surface coverage of the electrode, Γ, was made by adopting the method used by Sharp et al. [55] in Eq. (2):
According to this method, the peak current is related to the surface concentration of electroactive species. Where n shows the number of electrons involved in reaction, A is the surface area (0.1 cm2), and Γ obtained 7.0 × 10−8 mol cm−2 for n = 2.
The electrochemical behavior of DHB/CNT/CPE was studied at different pHs using CV. It was observed that the anodic peak potentials of DHB at DHB/CNT/CPE shift to negative values with increasing pH. The results showed that unit over a pH range from 4 to 9 the slope (E0'/pH) is 47.0 mv/pH, which is very close to the predicted Nernstian value of 59.2 mv for two electrons two protons [53].
Electrocatalytic oxidation of CAP at a DHB/CNT/CPE
Figure 2 shows the CVs responses for the electrochemical oxidation of 0.5 mM CAP at the unmodified CPE (curve b), CNT/CPE (curve d), modified CPE at DHB (curve e), and DHB/CNT/CPE (curve f). As can be seen, the anodic peak potential for CAP oxidation of CAP in surface of the unmodified CPE (curve b) is 430 mV, CNT/CPE (curve d) about 380 mV, and oxidation of CAP in surface of modified CPE with DHB (curve e) and DHB/CNT/CPE is about 250 mV. Potential of oxidation of CAP at modified electrodes with modifier is 180 mv more negative than unmodified electrodes with modifier. Similarly, when we compared the oxidation of CAP at the DHB/CPE (curve e) and DHB/CNT/CPE (curve f), there is a dramatic enhancement of the anodic peak current at DHB/CNT/CPE relative to the value obtained at the DHB/CPE. Also, modification with modifier decrease at the peak potential of oxidation of CAP compared with electrode without modifier. In other words, the data obtained clearly show that the combination of CNTs and mediator (DHB) definitely improve the characteristics of CAP oxidation. The DHB/CNT/CPE in 0.1 M phosphate buffer solution (pH 7.0), without CAP in solution, exhibits well-behaved redox reactions (curve c) upon the addition of 0.5 mM CAP, and there is a dramatic enhancement of the anodic peak current and delete of back current (curve f), which can be related to the strong electrocatalytic effect of the DHB/CNT/CPE toward this compound. According to whatever displayed, the best electrocatalytic effect for CAP oxidation is showed at DHB/CNT/CPE (curve f).
Figure 3I shows that the process enhanced the peaks current with increase scan rate by linear sweep voltammetry, which the oxidation peak potential relocated toward more positive potentials with increase scan rate, according to kinetic limitation in the electrochemical reaction. As seen in Fig. 3I, there is a linear correlation between plats of peak height (Ip) and the square root of scan (υ1/2) in the range of 5–90 mV s−1, that at enough over potential, the process was diffusion rather than surface controlled. Sweep rate (Fig. 3I) exhibits the characteristic shape typical of an EC' process [53].
The inset of Fig. 3II shows a Tafel plot that was drawn from points shown in the linear sweep voltammetry. This part of the voltammogram, known as Tafel region, is affected by electron transfer kinetics between substrate (CAP) and surface-confined DHB, assuming the deprotonation of substrate as a sufficiently fast step. In this condition, the number of electron involved in the rate-determining step can be estimated from the slope of Tafel plot. A slope 0.181 V is obtained, indicating a one-electron transfer to be the rate-limiting step assuming a charge transfer coefficient of α = 0.67.
Chronoamperometric investigation
The chronoamperometry as well as the other electrochemical methods was employed for the investigation of electrode processes at chemically modified electrodes. Chronoamperometric measurements of CAP at DHB/CNT/CPE were carried out by setting the working electrode potential at 350 mV for various concentrations of CAP (Fig. 4). For an electroactive material (CAP in this case) with a diffusion coefficient of D/cm2 s−1, the current observed for the electrochemical reaction at a mass transport limited condition is described by the Cottrell equation [53].
We have employed a plat of I versus t −1/2 that will be linear, then from the slopes plotted versus the CAP concentration, the value 3.61 × 10−6 cm2 s−1 for D be obtained (Fig. 4b). Chronoamperometry can also be used to gain the catalytic rate constant, kh, for the reaction between CAP and the DHB/CNT/CPE, according to the method of Galus [56].
Where t is the time elapsed and c is the balk concentration of CAP.
The average value of k was found at 3.55 × 104 M−1 s−1, using the value of the slopes, that is shown in Fig. 4c and mentioned equation. The value of k explains as well as the sharp feature of the catalytic peak observed for catalytic oxidation of CAP at the surface of DHB/CNT/CPE. Finally, the heterogeneous rate constant (k′) of catalytic reaction was calculated as k′ = 2.49 × 10−3 cm s−1 (with Γ = 7.0 × 10−8 mol cm−2).
Calibration plot and limit of detection
Differential pulse voltammetry (DPV) can analyze the electrode reaction exactly and the resolution better than cyclic voltammetry. So the electrocatalytic peak current of CAP oxidation at the surface of DHB/CNT/CPE can be used for determining CAP in phosphate buffer solution containing various concentrations of CAP. DPVs can be used in estimating the limits of detection to determine trace amounts of CAP. In addition, the charging current contribution to the background current, which is a limiting factor in the analytical determination, is negligible in DPV mode.
The plot of peak current versus CAP concentration consisted of two linear segments with slopes of 0.0592 and 0.0070 μA μM−1 in the concentration ranges of 7.0–100.0 and 100.0–2,500.0, respectively. The decrease in sensitivity (slope) in the second linear range is likely to be due to kinetic limitation [53]. The detection limit (3σ) for CAP in the lower range region was found to be 2.43 μM.
Simultaneous determinations of CAP and some biological molecules
The ability of resolution of the electrochemical responses of different analyst is one of the important parameters at selecting a type of modified electrode. To the best of our knowledge, there is no prior report on the simultaneous determination of CAP, AC, TRP, FA, and l-Cys. Therefore, the main object of this work was to detect IP and some biological molecules simultaneously using DHB/CNT/CPE. This was performed by simultaneously changing the concentration of analytes, and recording the DPVs. Detection limit and linear range are comparable with values reported by other research groups for electrocatalytic oxidation of CAP at the surface of chemically modified electrodes by other mediators in Table 1 [57–61].
Simultaneous determination of CAP, AC, and Trp
DPVs were recorded simultaneously changing the concentration of captopril, acetaminophen, and tryptophan, which shows the oxidation potential of these three analytes at 0.18, 0.36, and 0.66 V, respectively (Fig. 5). They are exactly separable from each other. The detection limits of AC and Trp were obtained at 3.41 and 1.5 μM, respectively, since the obtained value of slope for CAP is 0.079 μA μM−1, and alone, CAP is 0.070 μA μM–1; these two values of slopes are very close to each other, so this electrode can easily be used for the determination of CAP in mixture of different concentration of AC and Trp simultaneously without significant interference. If the CAP signal is affected by the AC or Trp, the abovementioned slopes would be different.
Simultaneous determination of CAP and FA
Figure 6I shows responses of DPVs for mixture solution of different concentrations of captopril and folic acid simultaneously without interference. Oxidation potential of CAP and FA were recorded at 0.18 and 0.64 μM, respectively. The limit detection of FA obtained at 6.54 and the value of slope for CAP in this mixture and alone CAP is the same (0.0070 μA μM–1), so the modified electrode can be used for determination of CAP in princes of FA.
Simultaneous determination of CAP and l-cysteine
Since the voltammetric signals of CAP and l-Cys are close to each other at the bare electrode, we use DHB/CNT/CPE for the simultaneous determination of CAP and l-Cys by simultaneously changing their concentrations in the solution. DPV results show two well-distinguished anodic peaks at potentials of 0.17 and 0.56 V, indicating that the simultaneous determination of CAP and l-Cys is possible at the DHB/CNT/CPE (Fig. 6II). The limit detection of l-Cys obtained at 10.28 μM and the value of slope for CAP in this mixture (0.0069 μA μM–1) and alone CAP (0.0070 μA μM–1) is very close together, so the modified electrode can be used for determination of CAP in princes of l-Cys without significant interference.
Interference study
The influence of various foreign species on the determination of CAP was investigated. The tolerance limit was taken as the maximum concentration. Of the foreign substances which caused an approximately 5 % relative error in the determination, acetaminophen, ascorbic acid, vitamin B6, uric acid, glycine, glucose, penicillin sodium, N-acetyl at 15 times concentration of CAP and epinephrine, dopamine, folic acid, tyrosine, and levodopa at 5 time concentration toward CAP did not show interference in the determination of CAP.
Real sample analysis
In order to evaluate the analytical applicability of the proposed method, also it was applied to the determination of CAP, AC, TRP, FA, and l-Cys in human blood serum samples. The sample was found to be free from these analytes. Therefore, different amounts of analytes were spiked to the sample and analyzed by the proposed method. The results for determination of these analytes species in real samples are given in Table 2. Satisfactory recovery of the experimental results was found for these analytes.
The repeatability and stability of DHB/CNT/CPE
The electrode capability for the generation of a reproducible surface was examined by CVs data obtained in optimum solution pH from five separate samples that prepared DHB/CNT/CPE. The calculated RSD for various parameters was accepted as the criteria for a satisfactory surface reproducibility (1–4 %). This degree of reproducibility is virtually the same as that expected for the renewal or ordinary carbon paste surface. In addition, the long-term stability of the DHB/CNT/CPE was tested over a 3-week period. When CVs were recorded after the modified electrode was stored in an atmosphere at room temperature, the peak potential for CAP oxidation was unchanged and the current signals showed only less than 2.1 % decrease of the initial response. The antifouling properties of modified electrode towards CAP oxidation and its oxidation products were investigated by recording the cyclic voltammograms of modified electrode before and after using in the presence of CAP. Cyclic voltammograms were recorded in the presence of CAP after having cycled the potential for 20 cycles at a scan rate 100 mV s−1. The peak potentials were unchanged to positive values and the currents decreased by less than 2.1 %. Therefore, at the surface of DHB/CNT/CPE, not only the sensitivity increase, but the fouling effect of the analyte and its oxidation product also decreases. However, we regenerated the surface of DHB/CNT/CPE before each experiment.
Conclusions
A stable modified carbon nanotube paste electrode (modification with CNTs and DHB) with long stability and excellent reproducibility was fabricated. The modified electrode has been shown to be promising for determination of CAP with many desirable properties including high stability, selectivity, good reproducibility and repeatability, fast response time, together with the ease of preparation, low cost, and surface regeneration, making the proposed modified electrode very useful for accurate determination of CAP, AC, Trp, FA, and l-Cys in real samples. Thus, the electrode could electrochemically discriminate the sensing of CAP, AC, TRP, FA, and l-Cys. High sensitivity and selectivity of the voltammetric responses, and low detection limit, together with the ease of preparation and surface regeneration, make the proposed modified electrode very useful for accurate determination of these substrates in human serum samples.
References
Iijima S (1991) Helical microtubules of graphitic carbon. Nature 354:56–58
Mazloum-Ardakani M, Khoshroo A (2013) An electrochemical study of benzofuran derivative in modified electrode-based CNT/ionic liquids for determining nanomolar concentrations of hydrazine. Electrochim Acta 103:77–84
Mazloum-Ardakani M, Khoshroo A (2013) Nano composite system based on coumarin derivative–titanium dioxide nanoparticles and ionic liquid: determination of levodopa and carbidopa in human serum and pharmaceutical formulations. Anal Chim Acta 798:25–32
Mazloum-Ardakani M, Naser-Sadrabadi A, Sheikh-Mohseni MA et al (2013) An electrochemical sensor based on carbon nanotubes and a new Schiff base for selective determination of dopamine in the presence of uric acid, folic acid, and acetaminophen. Ionics 19:1663–1671
Goyal RN, Gupta VK, Chatterjee S (2008) Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode. Talanta 76:662–668
Afkhami A, Madrakian T, Shirzadmehr A et al (2012) A selective sensor for nanolevel detection of lead (II) in hazardous wastes using ionic-liquid/Schiff base/MWCNTs/nanosilica as a highly sensitive composite. Ionics 18:881–889
Mazloum-Ardakani M, Khoshroo A (2014) High performance electrochemical sensor based on fullerene-functionalized carbon nanotubes/ionic liquid: determination of some catecholamines. Electrochem Commun 42:9–12
Mazloum-Ardakani M, Khoshroo A (2014) Electrocatalytic properties of functionalized carbon nanotubes with titanium dioxide and benzofuran derivative/ionic liquid for simultaneous determination of isoproterenol and serotonin. Electrochim Acta 130:634–641
Goyal RN, Gupta VK, Bachheti N (2007) Fullerene-C60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone—an anabolic steroid used in doping. Anal Chim Acta 597:82–89
Gupta VK, Jain R, Radhapyari K et al (2011) Voltammetric techniques for the assay of pharmaceuticals—a review. Anal Biochem 408:179–196
Karimi-Maleh H, Ensafi AA, Allafchian AR (2010) Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode. J Solid State Electrochem 14:9–15
Geno PW, Ravichandran K, Baldwin RP (1985) Chemically modified carbon paste electrodes: Part IV. Electrostatic binding and electrocatalysis at poly(4-vinylpyridine)-containing electrodes. J Electroanal Chem Interfacial Electrochem 183:155–166
Ioannides X, Economou A, Voulgaropoulos A (2003) A study of the determination of the hypertensive drug captopril by square wave cathodic adsorptive stripping voltammetry. J Pharm Biomed Anal 33:309–316
Tache F, Farca A, Medvedovici A, David V (2002) Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a pre-column derivatization reaction with monobromobimane. J Pharm Biomed Anal 28:549–557
Huang T, He Z, Yang B et al (2006) Simultaneous determination of captopril and hydrochlorothiazide in human plasma by reverse-phase HPLC from linear gradient elution. J Pharm Biomed Anal 41:644–648
Askal HF (1991) New spectrophotometric methods for determination of captopril bulk drug and tablets. Talanta 38:1155–1158
Murillo Pulgarín JA, García Bermejo LF, López PF (2005) Sensitive determination of captopril by time-resolved chemiluminescence using the stopped-flow analysis based on potassium permanganate oxidation. Anal Chim Acta 546:60–67
Goyal RN, Gupta VK, Chatterjee S (2008) Electrochemical oxidation of 2’, 3’-dideoxyadenosine at pyrolytic graphite electrode. Electrochim Acta 53:5354–5360
Goyal RN, Gupta VK, Bachheti N, Sharma RA (2008) Electrochemical sensor for the determination of dopamine in presence of high Concentration of ascorbic acid using a Fullerene C60 coated gold electrode. Electroanalysis 20:757–764
Gupta VK, Mangla R, Khurana U, Kumar P (1999) Determination of uranyl ions using poly(vinyl chloride) based 4-tert-butylcalix [6] arene membrane sensor. Electroanalysis 11:573–576
Gupta VK, Prasad R, Kumar P, Mangla R (2000) New nickel (II) selective potentiometric sensor based on 5, 7, 12, 14-tetramethyldibenzotetraazaannulene in a poly (vinyl chloride) matrix. Anal Chim Acta 420:19–27
Gupta VK, Prasad R, Kumar A (2003) Preparation of ethambutol–copper (II) complex and fabrication of PVC based membrane potentiometric sensor for copper. Talanta 60:149–160
Gupta VK, Nayak A, Agarwal S, Singhal B (2011) Recent advances on potentiometric membrane sensors for pharmaceutical analysis. Comb Chem High Throughput Screen 14:284–302
Jain AK, Gupta VK, Singh LP, Raisoni JR (2006) A comparative study of Pb2+ selective sensors based on derivatized tetrapyrazole and calix [4] arene receptors. Electrochim Acta 51:2547–2553
Gupta VK, Jain S, Khurana U (1997) A PVC-based pentathia-15-crown-5 membrane potentiometric sensor for mercury(II). Electroanalysis 9:478–480
Gupta VK, Sethi B, Sharma RA et al (2013) Mercury selective potentiometric sensor based on low rim functionalized thiacalix [4]-arene as a cationic receptor. J Mol Liq 177:114–118
Gupta VK, Chandra S, Mangla R (2002) Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor. Electrochim Acta 47:1579–1586
Gupta VK, Jain S, Chandra S (2003) Chemical sensor for lanthanum(III) determination using aza-crown as ionophore in poly(vinyl chloride) matrix. Anal Chim Acta 486:199–207
Gupta VK, Chandra S, Lang H (2005) A highly selective mercury electrode based on a diamine donor ligand. Talanta 66:575–580
Gupta VK, Jain AK, Maheshwari G et al (2006) Copper (II)-selective potentiometric sensors based on porphyrins in PVC matrix. Sensor Actuator B Chem 117:99–106
Gupta VK, Singh AK, Mehtab S, Gupta B (2006) A cobalt(II)-selective PVC membrane based on a Schiff base complex of N, N′-bis(salicylidene)-3,4-diaminotoluene. Anal Chim Acta 566:5–10
Prasad R, Gupta VK, Kumar A (2004) Metallo-tetraazaporphyrin based anion sensors: regulation of sensor characteristics through central metal ion coordination. Anal Chim Acta 508:61–70
Gupta VK, Jain AK, Kumar P (2006) PVC-based membranes of < i > N</i > < i > N</i > ′-dibenzyl-1, 4, 10, 13-tetraoxa-7, 16-diazacyclooctadecane as Pb (II)-selective sensor. Sensor Actuator B Chem 120:259–265
Gupta VK, Jain AK, Kumar P et al (2006) Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix. Sensor Actuator B Chem 113:182–186
Gupta VK, Singh AK, Al Khayat M, Gupta B (2007) Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II). Anal Chim Acta 590:81–90
Gupta VK, Singh LP, Singh R et al (2012) A novel copper (II) selective sensor based on dimethyl 4, 4’(o-phenylene) bis (3-thioallophanate) in PVC matrix. J Mol Liq 174:11–16
Srivastava SK, Gupta VK, Jain S (1996) PVC-based 2, 2, 2-cryptand sensor for zinc ions. Anal Chem 68:1272–1275
Jain A, Gupta VK, Singh L et al (1997) Macrocycle based membrane sensors for the determination of cobalt (II) ions. Analyst 122:583–586
Gupta VK, Ganjali MR, Norouzi P et al (2011) Electrochemical analysis of some toxic metals by ion–selective electrodes. Crit Rev Anal Chem 41:282–313
Ensafi AA, Karimi-Maleh H, Ghiaci M, Arshadi M (2011) Characterization of Mn-nanoparticles decorated organo-functionalized SiO2–Al2O3 mixed-oxide as a novel electrochemical sensor: application for the voltammetric determination of captopril. J Mater Chem 21:15022–15030
Ensafi AA, Arabzadeh A (2012) A new sensor for electrochemical determination of captopril using chlorpromazine as a mediator at a glassy carbon electrode. J Anal Chem 67:486–496
Fouladgar M (2011) Electrocatalytic measurement of trace amount of captopril using multiwall carbon nanotubes as a sensor and ferrocene as a mediator. Int J Electrochem Sci 6:705–716
Karimi-Maleh H, Mehdipour-Ataei S, Hatami M, Khalilzadeh MA (2014) Voltammetric determination of captopril using a novel ferrocene-based polyamide as a mediator and multi-wall carbon nanotubes as a sensor. J Anal Chem 69:162–168
Mazloum-Ardakani M, Hosseinzadeh L, Khoshroo A et al (2014) Simultaneous determination of isoproterenol, acetaminophen and folic acid using a novel nanostructure-based electrochemical sensor. Electroanalysis 26:275–284
Fang B, Wei Y, Li M et al (2007) Study on electrochemical behavior of tryptophan at a glassy carbon electrode modified with multi-walled carbon nanotubes embedded cerium hexacyanoferrate. Talanta 72:1302–1306
Mazloum-Ardakani M, Naser-Sadrabadi A, Sheikh-Mohseni MA et al (2013) Oxidized multiwalled carbon nanotubes for improving the electrocatalytic activity of a Schiff base modified electrode in determination of isoprenaline. J Electroanal Chem 705:75–80
Mazloum-Ardakani M, Sheikh-Mohseni M, Mirjalili B-F (2014) Nanomolar detection limit for determination of norepinephrine in the presence of acetaminophen and tryptophan using carbon nanotube-based electrochemical sensor. Ionics 20:431–437
Mishra S, Tripathi RD, Srivastava S et al (2009) Thiol metabolism play significant role during cadmium detoxification by Ceratophyllum demersum L. Bioresour Technol 100:2155–2161
Yin GN, Lee HW, Cho J-Y, Suk K (2009) Neuronal pentraxin receptor in cerebrospinal fluid as a potential biomarker for neurodegenerative diseases. Brain Res 1265:158–170
Mazloum-Ardakani M, Taleat Z, Beitollahi H, Naeimi H (2010) Selective determination of cysteine in the presence of tryptophan by carbon paste electrode modified with quinizarine. J Iran Chem Soc 7:251–259
Deng C, Chen J, Chen X et al (2009) Electrochemical detection of l-cysteine using a boron-doped carbon nanotube-modified electrode. Electrochim Acta 54:3298–3302
Mazloum-Ardakani M, Sabaghian F, Khoshroo A, Naeimi H (2014) Simultaneous determination of the concentrations of isoproterenol, uric acid, and folic acid in solution using a novel nanostructure- based electrochemical sensor. Chinese J Catal 35:565–572
Bard AJ, Faulkner LR (2000) Electrochemical methods: Fundamentals and applications, 2nd ed. Wiley
Laviron E (1979) General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J Electroanal Chem Interfacial Electrochem 101:19–28
Sharp M, Petersson M, Edström K (1979) Preliminary determinations of electron transfer kinetics involving ferrocene covalently attached to a platinum surface. J Electroanal Chem Interfacial Electrochem 95:123–130
Galus Z, Reynolds GF, Marcinkiewicz S (1976) Fundamentals of electrochemical analysis. Ellis Horwood New York
Khalilzadeh MA, Karimi-Maleh H, Amiri A, Gholami F (2010) Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode. Chinese Chem Lett 21:1467–1470
Ensafi AA, Karimi-Maleh H, Mallakpour S, Rezaei B (2011) Highly sensitive voltammetric sensor based on catechol-derivative-multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples. Colloids Surf B Biointerfaces 87:480–488
Habibi D, Faraji AR, Gil A (2013) A highly sensitive supported manganese-based voltammetric sensor for the electrocatalytic determination of captopril. Sensor Actuator B Chem 182:80–86
Mazloum-Ardakani M, Sheikh-Mohseni MA, Mirjalili B-F, Zamani L (2012) Simultaneous determination of captopril, acetaminophen and tryptophan at a modified electrode based on carbon nanotubes. J Electroanal Chem 686:12–18
Rezaei B, Damiri S (2008) Voltammetric behavior of multi-walled carbon nanotubes modified electrode-hexacyanoferrate (II) electrocatalyst system as a sensor for determination of captopril. Sensor Actuator B Chem 134:324–331
Karimi-Maleh H, Moazampour M, Gupta VK, Sanati AL (2014) Electrocatalytic determination of captopril in real samples using NiO nanoparticle modified (9,10-dihydro-9,10-ethanoanthracene-11,12-dicarboximido)-4-ethylbenzene-1,2-diol carbon paste electrode. Sensor Actuator B Chem 199:47–53
Raoof JB, Ojani R, Baghayeri M (2011) Sensitive voltammetric determination of captopril using a carbon paste electrode modified with nano-TiO2/ferrocene carboxylic acid. Chinese J Catal 32:1685–1692
Ensafi AA, Rezaei B, Mirahmadi-Zare Z, Karimi-Maleh H (2011) Highly selective and sensitive voltammetric sensor for captopril determination based on modified multiwall carbon nanotubes paste electrode. J Braz Chem Soc 22:1315–1322
Acknowledgments
The authors wish to thank the Yazd University Research Council, the IUT Research Council, and Excellence in Sensors for financial support of this research.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mazloum-Ardakani, M., Sabaghian, F., Khoshroo, A. et al. Electrochemical determination of captopril in the presence of acetaminophen, tryptophan, folic acid, and l-cysteine at the surface of modified carbon nanotube paste electrode. Ionics 21, 239–250 (2015). https://doi.org/10.1007/s11581-014-1159-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11581-014-1159-3