Introduction

The Goos-Hänchen (GH) effect is a phenomenon of geometric optics where the light beam, reflected from the interface of dielectric media, shifts laterally in the plane of incidence away from the theoretically predicted position [1]. This kind of shift is called GH shift. After the innovation of laser and the development of integral optics, the GH shift phenomenon has been actively explored for applications in electronics [2, 3], optical waveguide switch [4], and optical temperature sensing [5]. The stationary phase method, proposed by Artmann, theoretically explains this effect and clearly indicates its close relationship with the phase change of the reflected light [6]. Surface plasmon resonance (SPR) is a special electromagnetic wave resulting from the surface charge density collective oscillation, which is excited at the interface between two materials having negative and positive permittivities, respectively. And the SPR has been extensively studied in theory and experiment and used in the development of biosensors for medical diagnostics [7], food safety, and other areas. In the SPR arrangement, an abrupt change in the phase of a p-polarized (whose polarization direction is parallel to the incident plane) reflected light occurs at the resonance condition. Hence, the SPR effect has been widely investigated in the plasmonic sensing field to detect chemical and biological parameters that cause the change in refractive index (RI) near the sensing interface [8, 9]. Thus, it is natural to propose the combination of the GH shift effect and SPR sensing through phase change measurements occurring at the minimum reflectivity point of the SPR curve [10,11,12,13].

Two-dimensional (2D) transition metal dichalcogenides (TMDCs) are gathering rising research interest because of their unique properties such as tunable photonic bandgap, high charge mobility, and large absorption of light [14, 15]. Specifically, PtSe2, an emerging group 10 TMDC, bears optical properties different from other group 6 TMDCs. It has a 1T-phase, implying 6 Se atoms in the space surround one Pt atom, as seen from the top view. The continuous 1T-PtSe2 is an isotropic plane, and its monolayer film with the thickness of 2.53 Å can provide the biggest bandgap of 1.2 eV [16]. In contrast, bilayer PtSe2 samples with interlayer distance of 5.07 Å have a narrower bandgap of 0.21 eV. The interlayer distance between multiple layers or bulk PtSe2 reduces on increasing the layer numbers because of the strong coupling covalent bands between the neighboring structure. Hence, PtSe2 undergoes a phase transition from the indirect bandgap semiconductor of the monolayer and bilayer structures to a semimetal character of multiple layers and bulk PtSe2 [17, 18]. The RI of this layer-dependent material as well as its absorption spectrum also depends strongly on the film thickness [19], which provides another modulation method when the material is applied to optoelectronic devices [16, 20]. In addition, PtSe2 has extremely high mobility of 3000 cm2 V−1 s−1, and large electrical conductivity which can only be achieved by varying its thickness [21,22,23]. These characteristics of PtSe2 allow it to be an ideal candidate for high-speed electronic applications in the infrared region. However, controlled preparation of this 2D TMDC material with large-area and high-quality uniform is still a huge challenge, so it is of critical advantages to investigate the characteristics of this material in theory and provide certain guided advice when the sound preparation process is developed.

In the present work, we systemically design and simulate the plasmonic sensing schemes at conditions of (1) different PtSe2 thicknesses, (2) discrete excitation wavelengths, and (3) different types of coupling prism, to improve the sensitivity of biomolecular GH shift sensor based on SPR configuration. We also consider the assistant role of graphene on improving the sensing performance based on the high optical absorption rate of graphene and wavelength-dependent RI variation tendency similar to that of PtSe2. By tuning (a) the gold film’s thickness, (b) the layer numbers of graphene, and (c) the thickness of PtSe2 layer, four optimum sensing configurations can be found at different excitation wavelengths. One of these configurations shows a GH shift sensitivity enhancement of four times more than that of sensors based on bare gold. In addition, we also report the detection limit for solutions containing low concentrations of biomolecules and the corresponding sensitivity with the optimum sensing configurations.

Theory and Simulation Method

In the present simulation, we employ four different wavelengths (532 nm, 632.8 nm, 780 nm, and 1152 nm) spanning from visible light to near-infrared region. They are the working wavelengths irradiated by Nd:YAG laser or diode pump solid-state laser (532 nm), He-Ne gas laser (632.8 nm, 1152 nm), and GaAlAs laser (780 nm), all of which are widely used in the laboratory and industry. Additionally, three different prisms, namely BK7, SF5, and SF11, most commonly applied in the SPR configurations, are chosen to couple the incident light into the proposed biosensor. Titanium (Ti) layer with 2.5 nm thickness is utilized to attach gold (Au) onto the prism. While gold and silver are usually chosen to be the plasmonic metal of SPR-based sensors, gold is preferred because of its chemical stability. Since a too thin or too thick gold film is not good at coupling electromagnetic waves into surface waves, the thickness of gold film is increased from 30 nm by 1-nm step to 60 nm. Graphene dielectric layers with excellent optoelectronic properties are grown on the upper surface of gold thin film to improve the SPR biosensor sensitivity. The thickness of monolayer graphene is 0.34 nm, so the total thickness of L-layer graphene equals to d = L × 0.34 nm [24]. 2D PtSe2 with different thicknesses is coated over graphene, and it acts as the sensing interface which contacts directly with the sensing medium. The incident angle is adjusted from the critical angle to the almost grazing incidence by the spacing of 0.1° which is reasonable according to the precision accuracies of the rotation stage and micrometer used in the experiment. At first, we consider de-ionized (DI) water to be the analyte solution, and later, DI water contains biomolecules. The RI of analyte solution will increase by Δnbio after biomolecules are adsorbed on the PtSe2 surface. Briefly, this is a six-layered system, containing the prism, titanium, gold, graphene, PtSe2, and analyte solution, as shown in Fig. 1. The refractive indices of all these materials at the four excitation wavelengths are presented in Table 1.

Fig. 1
figure 1

P-polarized reflected light from the layered sensing system of graphene-assisted 2D PtSe2 to enhance GH lateral shift. The inset is the vertical view of PtSe2

Table 1 Refractive indices (RI) of Au, prisms (BK7/SF5/SF11), graphene, DI water, titanium, and PtSe2 with different thicknesses at various excitation wavelengths used in the proposed structure

Since only p-polarized lights can excite the surface plasmons, the s-polarized lights (whose polarization direction is perpendicular to the incident plane) can be used as a reference to determine other parameters’ influence on the sensing performance. This is an advantageous factor as it aids not only in eliminating the environmental noises but also in reducing the error caused by the non-ideal profile of the light source when doing experiments to improve the measurement accuracy.

Coming to the principle behind the GH shift, for one interface system, when a beam illuminates from dielectric 1 with permittivity of ε1 onto the interface of dielectric 2 with permittivity of ε2 at an incident angle of θ, the reflectivity equals to

$$ {r}_{\mathrm{p}}\left(\theta, \omega \right)=\left(\frac{k_{\mathrm{z}1}}{\varepsilon_1}-\frac{k_{\mathrm{z}2}}{\varepsilon_2}\right)/\left(\frac{k_{\mathrm{z}1}}{\varepsilon_1}+\frac{k_{\mathrm{z}2}}{\varepsilon_2}\right) $$
(1)

for the p-polarized light and

$$ {r}_{\mathrm{s}}\left(\theta, \omega \right)=\left({k}_{\mathrm{z}1}-{k}_{\mathrm{z}2}\right)/\left({k}_{\mathrm{z}1}+{k}_{\mathrm{z}2}\right) $$
(2)

for the s-polarized light, where \( {k}_{z1}=\omega /c\sqrt{\varepsilon_1}\cos \theta \) and \( {k}_{z2}=\omega /c\sqrt{\varepsilon_2-{\varepsilon}_1{\sin}^2\theta } \).

But for an N-layered model presented here, we need to employ the transfer matrix method (TMM) to achieve the systemic reflectivity coefficient [28]. The matrix of the N-layered model is defined as

$$ M=\prod \limits_{k=2}^{N-1}{M}_k=\left[\begin{array}{cc}{M}_{11}& {M}_{12}\\ {}{M}_{21}& {M}_{22}\end{array}\right] $$
(3)

where Mk indicates the matrix of the kth layer. For p-polarized incident lights, Mk can be given by

$$ {M}_k=\left[\begin{array}{cc}\cos {\beta}_k& -i\sin {\beta}_k/{q}_k\\ {}-{iq}_k\sin {\beta}_k& \cos {\beta}_k\end{array}\right] $$
(4)

where \( {q}_k=\frac{{\left({\varepsilon}_k-{n}_1^2{\sin}^2{\theta}_1\right)}^{1/2}}{\varepsilon_k}=\frac{{\lambda \beta}_k}{2\pi {d}_k{\varepsilon}_k} \), \( {\beta}_k=\frac{2\pi {d}_k}{\lambda }{\left({\varepsilon}_k-{n}_1^2{\sin}^2{\theta}_1\right)}^{1/2} \), and dk is the thickness of the kth layer. Hence, it can easily obtain the four elements of the matrix—M11, M12, M21, and M22. Then, considering the boundary conditions of the electromagnetic wave propagation, the amplitude reflectivity coefficient rp of the N-layered model is obtained by

$$ {r}_{\mathrm{p}}=\frac{\left({M}_{11}+{M}_{12}{q}_N\right){q}_1-\left({M}_{21}+{M}_{22}{q}_N\right)}{\left({M}_{11}+{M}_{12}{q}_N\right){q}_1+\left({M}_{21}+{M}_{22}{q}_N\right)} $$
(5)

which is a complex quantity and can be written as \( {r}_{\mathrm{p}}=\left|{r}_{\mathrm{p}}\right|{e}^{j{\phi}_{\mathrm{p}}} \). Thus, the reflectivity Rp and phase ϕp of the p-polarized light are respectively extracted by

$$ {R}_{\mathrm{p}}={\left|{r}_{\mathrm{p}}\right|}^2\mathrm{and}\ {\phi}_{\mathrm{p}}=\arg \left({r}_{\mathrm{p}}\right) $$
(6)

The GH shift is obtained by differentiating phase as a function of the incident angle according to the stationary phase theory:

$$ {\mathrm{GHs}}_{\mathrm{p}}=-\frac{\lambda }{2\pi}\frac{d{\phi}_{\mathrm{p}}}{d\theta} $$
(7)

For s-polarized incident lights, the same equations hold, with qk replaced by \( {p}_k={\left({\varepsilon}_k-{n}_1^2{\sin}^2{\theta}_1\right)}^{1/2} \). So, the differential GH shift between s- and p-polarized lights is GHs = GHsp − GHss. The GH shift sensitivity S is then referred to be the ratio of the differential GH shift change \( \Delta \mathrm{GHs}=\mathrm{GHs}\left|{}_{n+\varDelta {n}_{\mathrm{bio}}}-\right.\mathrm{GHs}\left|{}_n\right. \) to the RI change Δnbio of the sensing medium caused by biomolecular adsorption, i.e.,

$$ S=\frac{\left|\Delta \mathrm{GHs}\right|}{\Delta {n}_{bio}} $$
(8)

Here, the detection accuracy of the GH shift sensing system is defined to be the full width at one-tenth maximum (FWTM) to characterize the sensing performance. The corresponding reflectivity RFWTM at one-tenth maximum equals to RFWTM = 0.1 × (Rmax + 9Rmin), wherein Rmax and Rmin representing the maximum and minimum reflectivities, respectively. The smaller the FWTM, the higher the detection accuracy. The sensing substrate and the optical parameters of all the underlying layers determine the value of FWTM. Enhanced factor refers to the ratio of sensitivity of the optimum sensing models to that of conventional bare gold sensing system, which quantitatively characterizes the enhancement sensitivity in the sensing models.

Results and Discussion

Before systematically investigating the GH shift sensitivity with these layered substrates in the sensing model, it is better to validate the relationship between the SPR excitation, phase abruption, and GH shift. If not specified in the following description, reflectivity refers to the reflectivity of p-polarized light. Since the SPR excitation leads to a drastic change in phase, the largest GH shift can be obtained. Figure 2 presents the complementary relationship between the minimum reflectivity of SPR curve, phase abruption, and the corresponding GH shift. For a thorough investigation of the influence of graphene and PtSe2 on the conventional SPR-based biomolecular sensor, we design three comparison models. In this paper, the conventional sensor structure with bare gold thin film is referred to be the first model. The second model is obtained by adding a layer of PtSe2 on the gold layer. The third model covers L layers of graphene between the gold film and PtSe2.

Fig. 2
figure 2

Reflectivity (dash), phase (solid), and GH shift (dotted) curves for the p-polarized light with respect to the incident angle for bare gold substrate coupled by SF5 prism at the excitation wavelength of 780 nm. The maximum GH shift and the most dramatic phase change coincide very well at the SPR angle. The FWTM of the reflectivity curve at RFWTM denoted in pink equals to 0.68°

In the simulation, the gold film’s thickness is increased from 30 nm by a 1-nm step to 60 nm. The comparison details between the SPR curves, phase changes, and GH shifts with various parameters are shown in Fig. S1. The minimum reflectivity of the SPR curve for every gold thickness can be obtained with different excitation wavelengths and coupling prisms, and the data are summarized in Fig. 3 (dotted curves). For each case, there exists an optimum gold thickness to achieve the maximum energy transfer and the minimum reflectivity. But the optimum gold thickness is different for each type of coupling prism. This is because the wavevector of SPR differs with the coupling prism according to the wavevector matching condition. In addition, the thickness of gold thin film plays a crucial role in exciting SPR because it can affect the coupling intensity of SPRs on both sides of the film. Hence, the optimum gold thickness depends on the applied wavelength and prism. Moreover, the optimum gold thickness decreases when the incident wavelength increases resulting from the increment of complex RI of gold. The solid curves in Fig. 3 are the counterpart modular changes of differential GH shift |ΔGHs| with the RI change of Δnbio = 0.005. It is clear that the maximum modular change of differential GH shift is coincident with its reflectivity curve. The lower the reflectivity, the larger the modular change of differential GH shift |ΔGHs|. In addition, a special prism utilized to couple a given incident light can yield the largest sensing signal.

Fig. 3
figure 3

Minimum reflectivities with respect to the gold thickness (dotted curves) for different coupling prisms at the excitation wavelengths of a 532 nm, b 632.8 nm, c 780 nm, and d 1152 nm; solid lines in every pattern represent the corresponding modular changes in differential GH shift |∆GHs| with the refractive index change of Δnbio = 0.005 for the first model

The SPR curves for the second model at different thicknesses of PtSe2 and other parameters are shown in Fig. 4a. When all parameters of the whole system achieves optimum values, the minimum reflectivity can reach 10−5. Even though the gold-excited SPR is mainly in the visible region, the near-infrared wavelength of 1152 nm can also effectively excite SPR due to the high electron mobility provided by PtSe2. The incident light wavelength not only changes the SPR angle through affecting its wavevector but also affects the width of SPR curve. The long excitation wavelength utilized has an appreciable effect on the width of the resonance curve which is determined by the complex permittivity of the metal. Generally, a complex permittivity having a big real part, together with a small imaginary part, results in narrow resonance curves. It is observed that the influence of PtSe2 thickness mainly determines the width of the SPR curve because of its layer dependence of refractive index, while it has small impact on the SPR excitation efficiency since not much difference between the minimal reflectivities of the two blue curves (excitation wavelength of 780 nm). In addition, the SPR curve becomes even narrower with long waves because the imaginary part of the refractive index of PtSe2 reduces with the wavelength leading to less energy loss due to electronic damping. This means the detection accuracy improves during this process. Other SPR curves with the same parameters but different thicknesses of PtSe2 can be seen in Fig. S2. The corresponding GH shift peaks, shown in Fig. 4b, become narrow and high due to the sharpest phase change at SPR angles, which lead to the largest GH shift at the excitation wavelength of 1152 nm when coupled by BK7 prism with the gold and PtSe2 thicknesses being 34 nm and 6 nm, respectively.

Fig. 4
figure 4

a SPR curves and b the corresponding GH shift lines with DI water as the analyte solution for different parameter combinations (presenting in legends) for the second model

The biomolecules in analyte solutions with various concentrations adsorb on the sensing layer, making a local change of RI near the sensing interface and changing the SPR resonance condition since it has a close relationship with the refractive index of dielectric medium. Specifically, after coating 2D material on the gold film, the optimum gold thickness for the first model corresponding to the largest differential GH shift between p- and s-polarized lights will different with the incident wavelength. Figure 5 presents the modular change in differential GH shift |∆GHs| with respect to the gold layer thickness under different excitation conditions with the RI change of Δnbio = 0.005. For BK7 prism, the variation pattern of the optimum thickness of gold film with the incident wavelength is the same as that of the first model. While for the other two prisms, the variation pattern with the wavelength changes from monotonous decline to first increase and then decrease because of the same variation pattern of the RI of PtSe2 with the wavelength. On the whole, however, the optimum gold thickness for all situations, to obtain the largest differential GH shift, decreases because of extra energy loss introduced by the layer of PtSe2 which can only be offset by reducing the thickness of gold thin film. The modular change in differential GH shift improves greatly for some cases indicating the unique effect of this 2D material for enhancing sensing performance. The modular change in differential GH shift |∆GHs| with other thicknesses of PtSe2 can be seen in Fig. S3.

Fig. 5
figure 5

The modular of differential GH shift change |∆GHs| with respect to the thickness of gold thin film and prisms with PtSe2 thickness of 2 nm at excitation wavelengths of a 532 nm, b 632.8 nm, c 780 nm, and d 1152 nm when the RI change of the aqueous solution equals to Δnbio = 0.005 for the second model

For the third model, we investigate the associated effect of graphene on the improvement in the sensing of GH shift after adding several layers of graphene between gold and PtSe2. The number of layers of graphene L is chosen from 1 to 15. Figure 6 shows the results of the modular change in differential GH shift |∆GHs| with respect to the layer numbers of graphene. Other variations with the layer numbers of graphene at different excitation wavelengths and prisms can be seen in Fig. S4. We do not find a clearly unified law that states the direct connection between the layer numbers of graphene and the gold thickness for achieving the best sensing signal. But it is quite clear that the GH shift increases largely with certain layers of graphene; this may attribute to its excellent optoelectronic properties and precise adjustable thickness. In addition, in order to get the largest possible |∆GHs|, it is really not necessary to have a high thickness of gold or a large value of L, because the higher thickness of gold or graphene will cause more energy absorption. For a given parameter set, there is only one optimum number of graphene layer to balance the signal enhancement and absorption loss leading to the sharpest phase change.

Fig. 6
figure 6

The modular change in differential GH shift |∆GHs| with the number of graphene layers at several thicknesses of gold film and with the combination of wavelength and prism of a 532 nm and SF11, b 632.8 nm and BK7, c 780 nm and BK7, and d 1152 nm and SF5 when the RI change of aqueous solution is Δnbio = 0.005

Table 2 lists some optimal configurations that we achieved on considering the parameters—the excitation wavelength, the different types of prisms, gold thickness, the layer numbers of graphene, and the PtSe2 thickness—and tuning them to achieve the largest modular change in differential GH shift |∆GHs| and the smallest width of SPR curve (FWTM ≤ 5°). We assume an RI change of Δnbio = 0.005 for the sensing layer.

Table 2 Optimal measured parameters at different fixed parameters showing the system characteristics based on Au/graphene/PtSe2 sensing substrate (Δnbio = 0.005)

Compared with the changes in resonance angle which are no more than 1°, the modular changes in differential GH shift are always larger than the results of angle interrogation. That is to say, it is much easier to detect the signal of GH shift change. Moreover, the largest GH shift change always corresponds to the nearly zero reflectivity Rmin, which is so small for every configuration under different excitation wavelengths that the efficiency of energy transfers to SPR is very high. The FWTM of the SPR curve increases rapidly with decreasing wavelength, the layer numbers of graphene and the PtSe2 thickness, from about 1° to almost 5°, mainly due to the RI change tendencies of prisms and gold. Enhanced factor indicates large improved sensing performance of these configurations in comparison with the sensitivity of conventional sensors only with gold as the sensing substrate. A suitable combination of all the layered materials can yield a more efficient sensing system.

We also compare several SPR-based sensors using different sensing signals, as seen in Table 3. Although the GH shift sensitivity slightly below that of phase interrogation, it is far more than that of angular interrogation and waveguide assistant GH shift sensor, particularly with the characteristics of easy measurement and low cost. Based on the above discussion, there are four optimized sensing configurations that should be further investigated their sensing performance. The four configurations are (i) 2 nm of PtSe2 structured on 31 nm of Au and coupled by BK7 prism at a wavelength of 532 nm, (ii) 4 nm of PtSe2 with triple-layer graphene structured on 34 nm of Au and coupled by BK7 prism at a wavelength of 780 nm, (iii) 2 nm of PtSe2 with bilayer graphene structured on 34 nm of Au and coupled by SF5 prism at a wavelength of 1152 nm, and (iv) 2 nm of PtSe2 with monolayer graphene structured on 34 nm of Au and coupled by SF11 prism at a wavelength of 1152 nm.

Table 3 Sensitivity comparison of SPR-based sensors

Figure 7 a–d show the modular change in differential GH shift |∆GHs| with the change in RI of the analyte solutions from 0 to 0.007 RI unit (RIU) for different numbers of graphene layer for the four selected configurations. The |∆GHs| changes significantly for the optimum configurations than for the non-optimum ones, and they quickly saturate with a tiny increase of RI. For some cases, the ∆GHs changes from positive to negative or vice versa presenting the local small dip or peak of the curve. It should further refine the change of RI with tiny steps and keep the sign of ∆GHs for better understanding the sensing performance.

Fig. 7
figure 7

ad Modular change in differential GH shift |∆GHs| with respect to the RI change of aqueous solutions under different layer numbers of graphene. The used wavelengths and prisms are selected from the optimum values shown in Table 2. eh ∆GHs curves for the configurations obtained from ad with optimal graphene layers with respect to tiny changes in RI of analyte solutions

The tiny step of refractive index change is first set to 1 × 10−6 when Δnbio increases from 0 to 0.00002, and then increased to 5 × 10−6. Figure 7 e–h show the differential GH shift change ∆GHs with respect to the tiny RI change for the four optimum configurations. All these curves have different variation tendencies, but all of them are nonlinear. Moreover, the data difference can be as high as twenty times indicating that not all of the optimum configurations are suitable for detecting the GH shift signal at very small concentration changes of analyte solutions. There may be a blank detection region where the curve of change in differential GH shift crosses the zero point, and whose width is determined by the values on both sides. For example, for the configuration of 2 nm of PtSe2 structured on 31 nm of Au and coupled by BK7 prism at a wavelength of 532 nm, it is hard to detect the GH shift signal when the RI change of the solution is within the range of 0.000055 RIU to 0.000065 RIU. However, we can still find a linear change region in every curve. The corresponding sensitivities are also shown in the figures. The GH shift sensitivity for tiny changes in RI manifests 10- to 100-fold enhancement than that for large changes in RI, showing more enhanced sensing performance for a small RI change, and more sensitive to detect minute molecules in the vicinity of sensing interface. Considering the precision of position sensing detector (Thorlabs, PDP90A) used in our laboratory, a lateral shift more than 2 μm can be effectively detected. Therefore, the detection limit for each optimum sensing configuration has a slight difference except one having much lower detection limit, as shown in Table 4. Additionally, compared with the conventional sensor, the detection limit of the optimum sensing configurations can be reduced by 2 orders of magnitude, and the sensitivity can significantly improve by 3 orders of magnitude.

Table 4 Comparison of the detection limit of GH shift sensing performance of the conventional and four proposed sensing configurations

At last, one point should be noticed is that the GH shift peaks for some cases are extremely high and narrow, which are actually determined by the definition of GH shift under stationary phase theory. The differential of phase singularity with the excitation of SPR may cause an error to some extent, which is the limitation of this method. Even though the drastic phase change around the resonance angle of SPR makes the GH shift value looked not so reasonable (the continuous phase change with the number of graphene layer is shown in Fig. S5, which also indicates indirectly the influence of graphene layers on the GH shift), the change tendencies of the GH shift with respect to the incident angle and the thicknesses of graphene and PtSe2 as well as the conditions for achieving the peaks of GH shift are correct and still valuable to guide the related experiment. In addition, the electric distributions of surface fields in the vicinity of sensing interface, as seen in Fig. S6, indicate that the evanescent filed can effectively extend in the aqueous solution, especially for long wavelengths.

Conclusion

In summary, we have employed two-dimensional materials of graphene and PtSe2 to form plasmonic sensing substrates to achieve enhanced GH shift detection sensitivity. The intriguing optical absorption rate of graphene and PtSe2 and fine adjustment thicknesses allow the achievement of ultralow light reflectivity at the SPR resonance angle. This minimum reflectivity leads to the abrupt phase change at the special incident angle and makes the lateral GH shift extremely sensitive to the RI change caused by adsorbing biomolecules which is contained in the aqueous solutions near the sensing interface. This adsorption is achieved by van der Waals force or ion force rather than functionalized layers. We have systematically optimized all parameters—the gold thickness and PtSe2 thickness, the layer numbers of graphene, the excitation wavelengths, and the types of coupling prisms. And we proposed four optimum configurations to improve the overall sensing performance at wavelengths ranging from visible light to near-infrared band. Among them, the configuration of 780-nm wavelength light incident on a 4-nm thickness of PtSe2 and triple-layer graphene structured on 34 nm of gold and coupled by BK7 prism yields the highest GH shift sensitivity enhancement, which is 4 times larger than that of conventional sensor. The detection limit of the RI change is as low as 5 × 10−7 RIU, which is reduced by 2 orders of magnitude compared with that of conventional gold sensor, and the corresponding sensitivity of biomolecules has a 1000-fold enhancement. A wide linear range of the tiny RI change from 7 × 10−5 to 1 × 10−4 with a large slope is obtained at the configuration of 2 nm thickness of PtSe2 with bilayer graphene structured on 34 nm of gold and coupled by SF5 prism with incident light of 1152-nm wavelength.