Abstract
MRI has been shown to be an extremely effective instrument in the management of painful hip arthroplasty. Its superior soft tissue contrast and direct multiplanar acquisition compared to computerized tomography (CT) and radiographs allows for reproducible visualization of periacetabular osteolysis, demonstrating compression of neurovascular bundles by extracapsular synovial deposits. In addition, MRI can often elucidate etiology of neuropathy in the perioperative period and is further helpful in evaluating the soft tissue envelope, including the attachment of the hip abductors, short external rotators and iliopsoas tendon. A further advantage of MRI over CT is its lack of ionizing radiation. Most importantly, MRI can disclose intracapsular synovial deposits that precede osteoclastic resorption of bone.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Magnetic resonance imaging (MRI) is beginning to be recognized as an important adjunctive imaging modality available to the orthopedic surgeon in the evaluation of patients with painful total hip arthroplasties and has been shown to be the most sensitive method to quantify the extent of periprosthetic osteolysis [1–5]. Painful complications associated with total hip arthroplasty include osteolysis with or without implant loosening, infection, neural injury, heterotopic ossification and dislocation [6, 7]. Conventional radiography, aspiration arthrography, nuclear scintigraphy and computerized tomography are the traditional modalities used to evaluate total hip arthroplasty complications. Whereas they remain very useful, they can be limited by poor soft tissue contrast, spatial resolution and/or specificity [8]. Furthermore, the use of ionizing radiation poses a cumulative radiation burden in the setting of longitudinal study. We will review the current experience using MRI to evaluate the total hip arthroplasty complications of osteolysis, infection, neural injury, heterotopic ossification, dislocation, and the painful hip of indeterminate etiology.
The previous limitations of MRI in total hip arthroplasty are a result of the signal artifact generated by the metallic components [9]. The metallic components cause a regional degradation of signal due to rapid dephasing of the excited nuclei. In addition, the metallic components have a different magnetic susceptibility and are thus more easily magnetized than the diamagnetic surrounding soft tissue, creating regional frequency shifts with alternating areas of low- and high-signal artifact that obscure the anatomic boundaries of surrounding bone and soft tissue. The degree of artifact is a function of several factors. Three important factors are the shape of the components, their orientation, and the relative ferromagnetism. Titanium causes less artifact than cobalt chrome because it is less ferromagnetic [3, 10].
In addition, aligning the long axis of the metallic components parallel to the axis of the frequency-encoding gradient, which may be an option at the time of image acquisition, also helps in diminishing this artifact [1, 3, 9, 10]. This accounts for the characteristic improved depiction of the surrounding soft tissue structures around the stem of the femoral component, which is parallel to the external magnetic field, as opposed to the acetabular component, wherein the screw or the cement mantle is oriented obliquely relative to the external field [1]. In addition, the spherical femoral head causes considerable frequency shifts, creating the greatest degree of artifact, and most likely accounting for the limited visualization of soft tissue structures around the acetabular component in previous studies, including evaluation of hip and shoulder arthroplasty [3, 9].
The technique used to perform MRI on total hip arthroplasties has been well described [1]. The pulse sequences used are all commercially available and may be duplicated on any closed, high field unit. The artifact reduction is achieved by the alteration of pulse sequence parameters to reduce the frequency shift that disturbs the MRI appearance of regional anatomic structures. These include the use of wider receiver bandwidths and/or commercially available modifications of the radio frequency profile. Fast spin-echo techniques use 180° refocusing “pulses”, which act to limit signal loss secondary to diffusion and thereby increase overall signal-to-noise ratio [3]. Additional frequency-selective fat suppression techniques are not recommended because of the local field disturbance that occurs in the presence of the metal and because fast inversion recovery sequences are a suitable substitute [10]. The use of these modified pulse sequence parameters allows reliable, consistent depiction of the surrounding soft tissue envelope and aids in the clinical problem of determining the cause of painful total hip arthroplasty.
At the Hospital for Special Surgery, images are obtained by using a 1.5-T clinical superconducting magnet (Sigma Horizon LX; General Electric Medical Systems, Milwaukee, WI, USA) with a shoulder phased array (Med Rad, Indianola, PA, USA) centered over the proximal aspect of the femur. A body coil is used and the images begin with a coronal fast inversion recovery sequence, a field of view of 35 cm, a repetition time of 4,500 to 5,000 milliseconds, an effective echo time of 17 milliseconds, an inversion time of 150 milliseconds, a receiver bandwidth of 31.2 to 62.5 kHz, and a slice thickness of 5 mm with no interslice gap. Additional images are obtained using fast spin-echo sequences (Fast Spin Echo XL, General Electric Medical Systems, Milwaukee, WI, USA) with a surface shoulder coil in the coronal, sagittal and axial planes, with a repetition time of 3,000 to 5,000 milliseconds, an echo time of 30 to 36 milliseconds, a wider receiver bandwidth of 62.5 to 100 kHz (over the entire frequency range), with a field of view ranging from 17 to 20 cm, slice thickness from 3 to 4 mm without gap, and matrix 512 by 320 to 384 excitations, resulting in a maximum in-plane resolution of 332 μm. Interecho spacing is further reduced by performing tailored radio frequency (tailored RF, General Electric Medical Systems) [1].
Osteolysis
Periprosthetic osteolysis remains the number one problem in total hip arthroplasty, often resulting in surgery to debride and bone graft lesions in patients with stable implants before they loosen or for revision of components once loosening has occurred. Conventional radiography consisting of serial radiographs has been the standard method of evaluating patients for the development of osteolysis [11–13]. However, it is generally recognized that conventional radiographs greatly underestimate the amount of bone destruction [14–16]. The addition of oblique views increases the likelihood of detecting the presence of osteolysis but continues to greatly underestimate the amount of bone destruction [17, 18]. In addition, conventional radiography is limited in that it represents a 2-dimensional analysis of a 3-dimensional problem [18]. Improved accuracy in assessing periprosthetic bone loss would not only facilitate preoperative planning for revision arthroplasty, but also provide an accurate means for serial evaluation of nonoperative treatment modalities as they become available.
Computerized tomography has recently been used to evaluate periprosthetic osteolysis [19]. Modifications in the software have resulted in a decrease in beam-hardening artifact, allowing for a more accurate 3-dimensional assessment of the extent of osteolysis. Robertson et al [20] demonstrated that plain radiographs underestimated bone loss by 20% or more in a study using computed tomography (CT) for evaluation of 19 patients with total hip arthroplasty. Although a dramatic improvement over conventional radiography, computerized tomography has the disadvantage of exposure of the patient to ionizing radiation, and techniques to reduce the beam hardening (“streak”) artifact require an increase in the dose applied. Another disadvantage of CT is the limitation in evaluating soft tissues and surrounding neurovascular structures.
In the past, MRI has been limited by the distortion resulting from signal loss around metallic implants. More recently, modifications in commercially available pulse-sequence parameters have allowed for accurate assessment of the bone and soft tissues about total hip arthroplasties [1, 2].
A recent study by Potter et al [1] demonstrated that MRI of 27 patients with 28 total hip arthroplasties allowed visualization of the bone/cement or bone/implant interface in all 28 hips. The appearance of osteolytic lesions with MRI was characterized by the presence of intraosseous intermediate to slightly increased signal intensity similar to skeletal muscle. There was also a characteristic line of low signal intensity surrounding the area of focal marrow replacement (Fig. 1). Extraosseous extension shared the same signal characteristics. The signal characteristics of infection and/or tumor are different, being less well defined and characteristically hyperintense and closer to that of fluid [1].
The correlation between MRI and radiographs in determining the location and presence of osteolysis was generally good [1]. There were 3 hips with discrepancies in location of lysis on the acetabular side. Plain radiographs failed to detect anterior column lesions in 2 hips, and motion artifact limited the MRI evaluation in one hip. Evaluation of the femoral side was a little more difficult. For one, the surface coil used did not extend to the tip of the femoral component, which severely limited the evaluation of Gruen zones 3, 4, 5, 10, 11, and 12. This resulted in a discrepancy in 3 hips where plain radiographs demonstrated osteolysis at the stem tip, which was not detected by MRI. In 5 hips, a lytic lesion was noted in Gruen zone 7 on radiographs but was not visualized on MRI. In 2 of these hips, osteolysis was recognized on MRI in Gruen zone 8, suggesting some variability in determining discrete zones on MRI compared with radiographs. In the other 3 hips, the marrow appeared normal in 2 and the MRI image was affected by motion in one. Although a direct comparison of osteolysis volume was not possible, the extent of osteolysis was grossly underestimated on the conventional radiographs. Subsequent revision of loosened components in 9 hips allowed for confirmation of the MRI lesions by both gross inspection and histopathology.
Validation data were performed in a cadaveric model in which simulated osteolytic defects of a known size were created in pelves implanted with standard cobalt chrome and titanium hip arthroplasties, followed by surrounding the model in an agarose medium to simulate the surrounding soft tissue [5, 21]. MRI analysis was compared to standardized radiographs (including bilateral oblique views) and CT with an optimized protocol to reduce the beam-hardening artifact. The sensitivity of MRI was 95% (83/87 possible lesions detected), whereas the sensitivity of CT was 75% (65/87 lesions detected) and the sensitivity of radiographs was 52% (45/87 lesions detected); MRI had consistently good lesion detection regardless of lesion location. Specificities for the 3 imaging modalities were similar, with radiographs at 96%, CT at 100%, and MRI at 98%. CT was more accurate in the measurement of larger lesion volumes [21]. Although the mean absolute error of lesion measured by MRI was greater than CT, the relative volumetric errors for MRI and CT were not significantly different [5].
Infection
Arthrography remains the diagnostic modality of choice to definitively diagnose an infection in total hip arthroplasty because it provides joint fluid for culture. Arthrography has been less useful in assessing implant loosening, limited by poor sensitivity particularly on the acetabular side [22, 23]. Results of nuclear scintigraphy, when normal, can aid in ruling out infection or loosening, but when positive lacks specificity and spatial resolution [24]. The use of radiolabeled white blood cells and colloid scans can improve the specificity of nuclear scintigraphy, the latter detecting postoperative alterations in marrow distribution [24]. However, they remain limited in providing anatomic images and evaluation of soft tissues, particularly as extraosseous sources of pain.
Although MRI cannot provide a definitive diagnosis of infection, it has been useful in helping to determine the extent of infection. In cases of superficial wound infection after total hip arthroplasty, MRI has been useful in confirming the superficial nature of the infection and resolution of the infection with antibiotic treatment (H.G. Potter, personal communication) (Fig. 2). In selected cases, MRI has also been useful in determining the extent of infection in patients with known deep infection of total hip arthroplasties. This is particularly useful if a psoas abscess is suspected, as these can be missed at the time of surgical extirpation and debridement and result in persistence of infection.
Neuropathy
Magnetic resonance imaging is the optimal means by which to image nerves surrounding hip arthroplasty. The information provided is not only useful in the evaluation of patients with nerve palsies but particularly useful in evaluating the relationship of screws or extravasated cement to the surrounding neurovascular structures in patients in whom a revision surgery is planned. In the case of nerve palsy, MRI can determine the presence or absence of direct injury (Fig. 3), hematoma, and/or scar tissue in the case of chronic injury. The data provided by MRI of neural injury after total hip arthroplasty may help to further our understanding of the mechanisms of injury.
Heterotopic ossification
The development of symptomatic and motion-limiting heterotopic ossification is fortunately a rare occurrence. The diagnosis is readily made using plain radiography. Computerized tomography has been used to assess the extent, and nuclear scintigraphy, the maturity of heterotopic ossification [25]. However, the extent of muscle involvement and the proximity or involvement of neurovascular structures can only be inferred. MRI of mature heterotopic ossification demonstrates discrete areas of fatty marrow signal intensity in the surrounding soft tissues, frequently without a well-defined plane. The ability to demonstrate the anatomical structures involved, particularly the proximity to neurovascular structures, makes MRI a very useful tool in the preoperative evaluation of patients in whom excision of heterotopic ossification is planned (Fig. 4).
Dislocation
Magnetic resonance imaging has been used to evaluate the soft tissues of total hip arthroplasty performed via a posterior approach after dislocation. Disruption of the posterior capsule and, in most cases, the external rotators has been demonstrated. (H.G. Potter, personal communication) Although the routine use of MRI in evaluating recurrent instability is not indicated, MR imaging may be of particular benefit in ruling out abductor avulsion or dehiscence of the short external rotators in patients with recurrent dislocation and/or presence of a persistent limp (Fig. 5).
Pain of indeterminate origin
Patients presenting with painful total hip arthroplasty and normal radiographs, nuclear scans, and negative aspirations can present a diagnostic dilemma to the surgeon. Although some diagnoses are made on the basis of clinical examination, MRI is becoming an important and useful adjuvant study. Diagnoses that have been confirmed or made using MRI include iliopsoas tendonitis, trochanteric bursitis, sacral insufficiency fracture, abductor avulsion, and, in one case, fracture of a femoral stem [26]. In addition, debris-related synovitis has been noted in the absence of osteolysis.
Conclusion
Magnetic resonance imaging has become a very useful and important adjuvant imaging modality in the evaluation of patients with total hip arthroplasty at the Hospital for Special Surgery. Its role in the evaluation of osteolysis continues to be defined but will likely emerge as the most accurate method of quantifying the location and extent of osteolysis, particularly given its ability to detect intracapsular burden of disease, which precedes osteoclastic resorption of bone. The spatial resolution and superior ability to image periarticular soft tissues including muscle, tendon, and neurovascular structures, combined with the ability to limit the prosthesis-induced artifact, has led to a significant increase in the utilization of MR imaging in the evaluation of postoperative complications related to total hip arthroplasty.
References
HG Potter BJ Nestor CM Sofka ST Ho LE Peters EA Salvati (2004) ArticleTitleMagnetic resonance imaging after total hip arthroplasty: Evaluation of periprosthetic soft tissue J Bone Joint Surg Am 86 1947–1954 Occurrence Handle15342757
HG Potter KD Montgomery DE Padgett EA Salvati DL Helfet (1995) ArticleTitleMagnetic resonance imaging of the pelvis: New orthopaedic applications Clin Orthop Rel Res 319 223–231
LM White JK Kim M Mehta N Merchant ME Schweitzer WB Morrison CR Hutchinson AE Gross (2000) ArticleTitleComplications of total hip arthroplasty: MR imaging—initial experience Radiology 215 254–262
NA Ebraheim ER Savolaine J Zeiss WT Jackson (1992) ArticleTitleTitanium hip implants for improved magnetic resonance and computed tomography examinations Clin Orthop Rel Res 275 194–198
Walde TA, Weiland DE, Leung SB, Kitamura N, Synchterz CJ, Engh CA Jr, Claus AM, Potter HG, Engh CA Sr (2005) Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: A cadaveric study. Clin Orthop Rel Res (in press)
CG Mohler DK Collis (1998) Early complications and their management JJ Callaghan AG Rosenberg HE Rubash (Eds) The adult hip, vol. II Lippincott-Raven Philadelphia 1125–1147
BG Evans (1998) Late complications and their management JJ Callaghan AG Rosenberg HE Rubash (Eds) The adult hip, vol. II Lippincott-Raven Philadelphia 1149–1161
P Aliabadi SS Tumeh BN Weissman et al. (1989) ArticleTitleCemented total hip prosthesis: Radiographic and scintigraphic evaluation Radiology 173 IssueID1 203–206
JA Lemmens JR Horn Particlevan J Boer Particleden W Riet Particlevan der JH Ruljs (1986) ArticleTitleMR imaging of 22 Charnley-Muller total hip prostheses Rofo Fortschr Geb Rontgenstr Nuklearmed 145 311–315 Occurrence Handle3020635
JW Sperling HG Potter EV Craig E Flatow RF Warren (2002) ArticleTitleMagnetic resonance imaging of painful shoulder arthroplasty J Shoulder Elbow Surg 11 315–321 Occurrence Handle10.1067/mse.2002.124426 Occurrence Handle12195247
WJ Hozack JJ Mesa C Carey RH Rothman (1996) ArticleTitleRelationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making J Arthroplasty 11 769–772 Occurrence Handle10.1016/S0883-5403(96)80175-6 Occurrence Handle8934315
RC Johnston RH Fitzgerald SuffixJr WH Harris R Poss ME Muller CB Sledge (1990) ArticleTitleClinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results J Bone Joint Surg Am 72 161–168 Occurrence Handle2303502
WJ Maloney P Peters CA Engh H Chandler (1993) ArticleTitleSevere osteolysis of the pelvis in association with acetabular replacement without cement J Bone Joint Surg 75 1627–1635 Occurrence Handle8245055
AS Carlsson CF Gentz (1984) ArticleTitleRadiographic versus clinical loosening of the acetabulur component in noninfected total hip arthroplasty Clin Orthop 185 145–150 Occurrence Handle6705372
JP Hodgkinson P Shelley BM Wroblewski (1988) ArticleTitleThe correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties Clin Orthop 228 105–109 Occurrence Handle3342551
CJ Sutherland (1988) ArticleTitleRadiographic evaluation of acetabular bone stock in failed total hip arthroplasty J Arthroplasty 3 73–79 Occurrence Handle3361323
RH Zimlich TK Fehring (2000) ArticleTitleUnderestimation of pelvic osteolysis: The value of the iliac oblique radiograph J Arthroplasty 15 796–801 Occurrence Handle10.1054/arth.2000.4330 Occurrence Handle11021458
DG Southwell JE Bechtold WD Lew AH Schmidt (1999) ArticleTitleImproving the detection of acetabular osteolysis using oblique radiographs J Bone Joint Surg Br 81 289–295 Occurrence Handle10.1302/0301-620X.81B2.9334 Occurrence Handle10204936
L Puri RL Wixson SH Stern J Kohli RW Hendrix SD Stulberg (2002) ArticleTitleUse of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty J Bone Joint Surg Am 84 609–614 Occurrence Handle11940623
DD Robertson CJ Sutherland T Lopes J Yuan (1998) ArticleTitlePreoperative description of severe acetabular defects caused by failed total hip replacement J Comput Assist Tomogr 22 444–449 Occurrence Handle10.1097/00004728-199805000-00018 Occurrence Handle9606388
Weiland DE, Walde TA, Leung JSJB, Sychterz CJ, Ho S, Engh CA, Potter HG (2005) Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: A cadaveric study. J Orthop Res (in press)
RL Barrack M Tanzer SV Kathapuram W Harris (1994) ArticleTitleThe value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components Skeletal Radiol 23 37–41 Occurrence Handle10.1007/BF00203699 Occurrence Handle8160035
TP Maus TH Berquist CE Bender JA Rand (1987) ArticleTitleArthrographic study of painful total hip arthroplasty: Refined criteria Radiology 162 IssueID3 721–727
JE Seabold JV Nepola JL Marsh DR Hawes EP Justin JA Ponto WA Petit GY el-Khoury PT Kirchner (1991) ArticleTitlePostoperative bone marrow alterations: Potential pitfalls in the diagnosis of osteomyelitis with In-111 labeled leukocyte scintigraphy Radiology 180 741–747
DG Lewallen (1995) ArticleTitleHeterotopic ossification following total hip arthroplasty Instr Course Lect 4 287–292
SM Cook PM Pellicci HG Potter (2004) ArticleTitleUse of magnetic resonance imaging in the diagnosis of an occult fracture of the femoral component after total hip arthroplasty. A case report J Bone Joint Surg Am 86 IssueID1 149–153 Occurrence Handle14711959
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Potter, H.G., Foo, L.F. & Nestor, B.J. What is the Role of Magnetic Resonance Imaging in the Evaluation of Total Hip Arthroplasty?. HSS Jrnl 1, 89–93 (2005). https://doi.org/10.1007/s11420-005-0112-4