Abstract
Rapid field-based screening methods for the semi-quantitative determination of heavy metals are desirable to support the increasing demand for the rapid characterization of contaminated sites. Single-use sensors have been fabricated using low-cost screen-printing (thick film) technology. These electrodes, coupled with differential pulse anodic stripping voltammetry (DPASV), have provided a rapid, inexpensive on site screening device for the simultaneous field-based determination of cadmium (Cd) and lead (Pb) in soil and water samples in the microgram per litre/kilogram range. A simplified soil extraction procedure, using 1 mol l−1 aqua regia and a 3 min ultrasonic sample agitation, has been developed to allow field-based device usage. Extraction efficiency was evaluated using a soil certified reference material (CRM). Recoveries of 64% and 52% for Cd and Pb respectively were obtained, with a relative standard deviation (RSD) of <8% for both analytes (n = 10). Soil samples (82) were tested using the combined extraction-DPASV procedure and compared against standard ICP-AES analysis. Correlation coefficients of 0.9782 and 0.9728 for Cd and Pb respectively demonstrate good correlation between methods. Analytical data is also reported for copper (Cu), but significant peak distortions reduce the confidence of the method for this metal. Results indicate that the combined extraction-DPASV method yields semi-quantitative data for rapid field-based site screening purposes.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Al-Merey, R., Al-Masri, M. S., & Bozou, R. (2002). Cold ultrasonic acid extraction of copper, lead and zinc from soil samples. Analytica Chimica Acta, 452, 143–148.
Blake, D. A., Jones, R. M., Blake II, R. C., Pavlov, A. R., Darwish, I. A., & Yu, H. (2001). Antibody-based sensors for heavy metal ions. Biosensors and Bioelectronics, 16, 799–809.
Bradshaw, M. P., & Scollary, G. R. (1997). The determination of copper at thin film electrodes by constant current stripping potentiometry. Electroanalysis, 9(4), 320–324.
Brainina, Kh. Z., Kubysheva, I. V., Miroshnikova, E. G., Parshakov, S. I., Maksimov, Y. G., & Volkonsky, A. E. (2001). Small-size sensors for the in-field stripping voltammetric analysis of water. Field Analytical Chemistry and Technology, 5(6), 260–271.
Choi, J.-Y., Seo, K., Cho, S.-R., Oh, J.-R., Kahng, S.-H., & Park, J. (2001). Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis. Analytica Chimica Acta, 443, 241–247.
Cooper, J. (1994). Electrochemical method for the rapid on site screening of heavy metals in soil and water samples. PhD Thesis, Cranfield University, Cranfield, UK.
Cuadros-Rodriguez, L., Gamiz-Gracia, L., Almansa-Lopez, E. M., & Bosque-Sendra, J. M. (2001). Calibration in chemical measurement processes. II. A methodological approach. Trends in Analytical Chemistry, 20(11), 620–636.
Desmond, D., Lane, B., Alderman, J., Hill, M., Arrigan, D. W. M., & Glennon, J. D. (1998). An environmental monitoring system for trace metals using stripping voltammetry. Sensors and Actuators B, 48, 409–414.
Esteban, M., & Casassas, E. (1994). Expert system for the voltammetric determination of trace metals. Trends in Analytical Chemistry, 13(3), 110–117.
Frenzel, W. (1993). Mercury films on a glassy carbon support: Attributes and problems. Analytica Chimica Acta, 273, 123–137.
Galan-Vidal, C. A., Munoz, J., Dominguez, C., & Alegret, S. (1995). Chemical sensors, biosensors and thick-film technology. Trends in Analytical Chemistry, 14(5), 225–231.
Hart, J. P., & Wring, S. A. (1994). Screen-printed voltammetric and amperometric electrochemical sensors for decentralised testing. Electroanalysis, 6, 617–624.
Hart, J. P., & Wring, S. A. (1997). Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses. Trends in Analytical Chemistry, 16(2), 89–102.
Honeychurch, K. C., & Hart, J. P. (2003). Screen-printed electrochemical sensors for monitoring metal pollutants. Trends in Analytical Chemistry, 22(7/8), 456–469.
Hou, X., & Jones, B. T. (2000). Field instrumentation in atomic spectroscopy. Microchemical Journal, 66, 115–145.
Hunter, A. J. R., Wainner, R. T., Piper, L. G., Davis, S. J. (2003). Rapid field screening of soils for heavy metals with spark-induced breakdown spectroscopy. Applied Optics, 42, 2102–2109.
Jagner, D., Sahlin, E., & Renman, L. (1995). Talanta, 42, 1447–1455.
Kadara, R. O., Newman, J. D., & Tothill, I. E. (2003). Analytica Chimica Acta, 493, 95–104.
Kebbekus, B. B., & Mitra, S. (1998). Environmental Chemical Analysis. Blackie Academic and Professional.
Kennedy, V. H., Sanchez, A. L., Oughton, D. H., & Rowland, A. P. (1997). Use of single and sequential chemical extractants to assess radionuclide and heavy metal availability from soils and root uptake. Analyst, 122, 89R–100R.
Marin, A., Lopez-Gonzalvez, A., & Barbas, C. (2001). Development and validation of extraction methods for determination of zinc and arsenic speciation in soils using focused ultrasound, Application to heavy metal study in mud and soils. Analytica Chimica Acta, 442, 305–318.
Miller, J. N., & Miller, J. C. (2000). Statistics and Chemometrics for Analytical Chemistry, 4th edition. Prentice Hall, Harlow.
Nolan, M. A., & Kounaves, S. P. (1999). Analytical Chemistry, 71, 1176–1182.
Nolan, M. A., & Kounaves, S. P. (2000). Electroanalysis, 12(2), 96–99.
Palchetti, I., Cagnini, A., Mascini, M., & Turner, A. P. F. (1999). Characterisation of screen-printed electrodes for detection of heavy metals. Mikrochimica Acta, 131, 65–73.
Perez-Cid, B., Lavilla, I., & Bendicho, C. (1998). Speeding up of a three-stage sequential extraction method for metal speciation using focused ultrasound. Analytica Chimica Acta, 360, 35–41.
Pollution Handbook 2003, National Society for Clean Air and Environmental Protection, Brighton, UK.
Sastre, J., Sahuquillo, A., Vidal, M., & Rauret, G. (2002). Determination of Cd, Cu, Pb and Zn in environmental samples: Microwave-assisted total digestion versus aqua regia and nitric acid extraction. Analytica Chimica Acta, 462, 59–72.
SENSPOL – Sensors for Monitoring Water Pollution from Contaminated Land, Landfills and Sediment 2002, European Commission funded EU Thematic Network on SENSPOL, Technical Workshop, Seville, Spain, 6–9 November 2002.
Valcarcel, M., Cardenas, S., & Gallego, M. (1999). Sample screening systems in analytical chemistry. Trends in Analytical Chemistry, 18(11), 685–694.
Wang, J. (1994a). Analytical Electrochemistry. New York: Wiley–VCH.
Wang, J. (1994b). Decentralised electrochemical monitoring for trace metals: From disposable strips to remote electrodes. Analyst, 119, 763–766.
Wang, J. (2002). Portable electrochemical systems. Trends in Analytical Chemistry, 21(4), 226–232.
Wang, J., & Luo, D. (1984). Effect of surface-active compounds on voltammetric stripping analysis at the mercury film electrode. Talanta, 31(9), 703–707.
Wang, J., Tian, B. M., & Rogers, K. R. (1998a). Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label. Analytical Chemistry, 70, 1682–1685.
Wang, J., Tian, B., Nascimento, V. B., & Angnes, L. (1998b). Performance of screen-printed carbon electrodes fabricated from different carbon inks. Electrochimica Acta, 43, 3459–3465.
Watson, C. (1994). Official and standardised methods of analysis, 3rd edition. Cambridge, UK: Royal Society of Chemistry.
Williams, G., & D’Silva, C. (1994). Field-based heavy metal analyser for the simultaneous determination of multiple cations on-site. Analyst, 119, 2337–2341.
Yarnitzky, C., Wang, J., & Tian, B. (2000). Hand-held lead analyzer. Talanta, 51, 333–338.
Zakharchuk, N. F., Saraeva, S. Yu., Borisova, N. S., & Brainina, Kh. Z. (1999). Modified thick-film graphite electrodes: Morphology and stripping voltammetry. Electroanalysis, 11, 614–622.
Zen, J., Chung, H., & Kumar, A. S. (2000). Analytica Chimica Acta, 421, 189–197.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cooper, J., Bolbot, J.A., Saini, S. et al. Electrochemical Method for the Rapid on Site Screening of Cadmium and Lead in Soil and Water Samples. Water Air Soil Pollut 179, 183–195 (2007). https://doi.org/10.1007/s11270-006-9223-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11270-006-9223-x