Abstract
Metallic endovascular stents are used as medical devices to scaffold biological lumen, most often diseased arteries, after balloon angioplasty. They are commonly made of 316L stainless steel or Nitinol, two alloys containing nickel, an element classified as potentially toxic and carcinogenic by the International Agency for Research on Cancer. Although they are largely implanted, the long-term safety of such metallic elements is still controversial, since the corrosion processes may lead to the release of several metallic ions, including nickel ions in diverse oxidation states. To avoid metallic ion release in the body, the strategy behind this work was to develop a process aiming the complete isolation of the stainless steel device from the body fluids by a thin, cohesive and strongly adherent coating of RF-plasma-polymerized fluoropolymer. Nevertheless, prior to the polymer film deposition, an essential aspect was the development of a pre-treatment for the metallic substrate, based on the electrochemical polishing process, aiming the removal of any fragile interlayer, including the native oxide layer and the carbon contaminated layer, in order to obtain a smooth, defect-free surface to optimize the adhesion of the plasma-deposited thin film. In this work, the optimized parameters for electropolishing, such as the duration and the temperature of the electrolysis, and the complementary acid dipping were presented and accurately discussed. Their effects on roughness as well as on the evolution of surface topography were investigated by Atomic Force Microscopy, stylus profilometry and Scanning Electron Microscopy. The modifications induced on the surface atomic concentrations were studied by X-ray Photoelectron Spectroscopy. The improvements in terms of the surface morphology after the pre-treatment were also emphasized, as well as the influence of the original stainless steel surface finish.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
T. W. DUERIG and A. R. PELTON, An overview of superelastic stent design. Mater. Sci. Forum 394–395 (2002) 1–8.
E. EECKHOUT, L. KAPPENBERGER and J.-J. GOY, Stents for intracoronary placement: current status and future directions. JACC 27 (4) (1996) 757–765.
H. WIENEKE, T. SAWITOWSKI, S. WNENDT, A. FISHER, O. DIRSCH, A. KAROUSSOS and E. R., Stent coating: a new approach in interventional cardiology. Herz 27 (2002) 518–526.
G. RIEPE, C. HEINTZ, E. KAISER, N. CHAKFE, M. MORLOCK, M. DELLING and H. IMIG. What can we learn from explanted endovscular devices? Eur. J. Vasc. Endovascular. Surg. 24 (2) (2002) 117–122.
O. F. BERTRAND, R. SIPEHIA, R. MONGRAIN, J. RODES, J. C. TARDIF, L. BILODEAU, G. COTE and M. G. BOURASSA, Biocompatibility aspects of new stent technology. J. Amer. Coll. Cardiol. Field 32(3) (1998) 562–71.
S. A. BROWN, K. ZHANG, K. MERRITT and J. H. PAYER, In vivo transport and excretion of corrosion products from accelerated anodic corrosion of porous coated F75 alloy. J. Biomed. Mater. Res. 27 (1993) 1007–1017.
M. L. PEREIRA, A. M. ABREU, J. P. SOUSA and G. S. CARVALHO, Chromium accumulation and ultrastructural changes in the mouse liver caused by stainless steel corrosion products. J. Mater. Sci.-Mater. Med. 6(9) (1995) 523–7.
C.-C. SHIH, C.-M. SHIH, Y.-L. CHEN, Y.-Y. SU, J.-S. SHIH, C.-F. KWOK and S.-J. LIN, Growth inhibition of cultured smooth muscle cells by corrosion products of 316 L stainless steel wire. J. Biomed. Mater. Res. 57 (2) (2001) 200–207.
S. TRIGWELL, R. D. HAYDEN, K. F. NELSON and G. SELVADURAY, Effects of Surface Treatment on the Surface Chemistry of NiTinol Alloy for Biomedical Applications. Surf. Interface Anal. 26 (1998) 483–489.
M. N. BABAPULLE and M. J. EISENBERG, Coated stents for the prevention of restenosis: Part 1. Circulation 106 (2002) 2734–2740.
M. N. BABAPULLE and M. J. EISENBERG, Coated stents for the prevention of restenosis: Part. II. Circulation 106 (2002) 2859–2866.
P. ROSSINI, P. COLPO, G. CECCONE, K. D. JANDT and F. ROSSI, Surfaces engineering of polymeric films for biomedical applications. Mater. Sci. Eng. C 23 (2003) 353– 358.
M.-R. YANG, K.-S. CHEN and J.-L. HE, The interaction between blood and the surface characteristics of plasma polymerized films. Mater. Chem. Phys. 48 (1) (1997) 71–75.
MORSHED, M. M., B. P. McNAMARA, D. C. CAMERON and M. S. J. HASHMI, Effect of surface treatment on the adhesion of DLC film on 316 L stainless steel. Surf. Coat. Technol. 163–164 (2003) 541–545.
R. O. ADAMS, A review of the stainless steel surface. J. Vac. Sci. Technol. A. 1(1) (1983) 12–18.
HASHIMOTO, M., Y. MIYAMOTO, Y. KUBO, S. TOKUMARU, N. ONO, T. TAKAHASHI and I. ITO, Surface modification of stainless steel in plasma environments. Mater. Sci. Eng. A. A198 (1–2) (1995) 75–83.
L. DESHAYES, M. CHARBONNIER, N. S. PRAKASH, F. GAILLARD and M. ROMAND, Spectroscopic characterization of stainless-steel surfaces treated by plasma. Surf. Interface Anal. 21 (1994) 711–717.
N. ISTEPHANEOUS, Z. BAI, J.L. GILBERT, K. ROHLY, A. BELU, I. TRAUSCH and D. UNTEREKER, Oxide films on metallic biomaterials: myths, facts and opportu- nities. Mater. Sci. Forum 426–432 (2003) 3157–3164.
E. J. SUTOW, The influence of electropolishing on the corrosion resistance of 316L stainless steel. J. Biomed. Mater. Res. 14 (1980) 587–595.
D. JENKINSON, Stainless steel: The importance of being smooth and passive. Corros. Mater. 27 (6) (2002) 10–13.
A. NOE, P. HENRY, P. EGELEY and J.-C. MOUGEOT, Le polissage, traitement de surface des aciers inoxydables. Corrosion 18 (3) (1970) 169–173.
D. LANDOLT, Review article. Fundamental aspects of electropolishing. Electrochim. Acta 32 (1) (1987) 1–11.
S. MOHAN, D. KANAGARAJ, R. SINDHUJA, S. VIJAYALAKSHMI and N.G. RENGANATHAN, Electropolishing of stainless steel—A review. Trans IMF 79 (4) (2001) 140–142.
M. BOJINOV, I. BETOVA, G. FABRICIUS, T. LAITINEN and R. RAICHEFF, Passivation mechanism of iron in concentrated phosphoric acid. J. Electroanal. Chem. 475 (1999) 58–65.
W. J. M. TEGART, Facteurs susceptibles de modifier les conditions de polissage, in Polissage électrolytique et chimique des métaux au laboratoire et dans l’industrie. Dunod: Paris. (1960) 32–36.
P. STEFANOV, D. STOYCHEV, M. STOYCHEV, A. R. GONZALEZ-ELIPE and T. MARINOVA, XPS, SEM and TEM Characterization of Stainless-Steel 316L Surfaces after Electrochemical Etching and Oxidizing. Surf. Interface Anal. 28 (1999) 106–110.
DE SCHEERDER, I., E. VERBEKEN and J. VAN HUMBEECK, Metallic surface modification. Semin. Interven. Cardiol. 3 (1998) 139–144.
H. ZHAO, J. VAN HUMBEECK, J. SOHIER and I. DE SCHEERDER, Electrochemical polishing of 316L stainless steel slotted tube coronary stents. J. Mater. Sci.-Mater. Med. 13 (2002) 911–916.
J. P. CAIRE, E. CHAINET, B. NGUYEN and P. VALENTI. Study of a new stainless steel electropolishing process, in AESF Annual Technical Conference. (1993).
D. BHASAVANICH and E.M. WILLIAMS, The influence of pre-vacuum surface conditioning on the response with electron stimulated desorption at stainless steel surfaces in uhv. Vacuum 30 (2) (1979) 91–92.
N. YOSHIMURA, T. SATO, S. ADACHI and T. KANAZAWA, Outgassing characteristics and microstructure of an electropolished stainless steel surface. J. Vac. Sci. Technol. A 8 (2) (1990) 924–929.
C. C. IRVING, Electropolishing stainless steel implants. ASTM Special Tech. Publ. 1985. 859: p. 136–143.
T. V. RAO, R. W. VOOK, W. MEYER and A. JOSHI, Effect of surface treatments on near surface composition of 316 nuclear grade stainless steel. J. Vac. Sci. Technol. A 4 (3) (1986) 1604–7.
E.-S. LEE, Machining characteristics of the electropolishing of stainless steel (STS316L). Int. J. Adv. Manuf. Technol. 16 (2000) 591–599.
C. WAGNER, Contribution of the theory of electropolishing. J. Electrochem. Soc. 101 (1954) 225–228.
K. ROHLY, N. ISTEPHANEOUS, A. BELU, D. UNTEREKER, M. COSCIO, J. HEFFELFINGER, R. THOMAS, J. ALLEN, R. FRANCIS, A. ROBINSON, N. PERRON, B. SAHLI and B. KOBIELUSH, Effect of time, temperature and solution composition on the passivation of 316L stainless steel for biomedical applications. Mater. Sci. Forum 426–432 (2003) 3017–3022.
L. PONTO, M. DATTA and D. LANDOLT, Electropolishing of iron-chromium alloys in phosphoric acid-sulphuric acid electrolytes. Surf. Coat. Technol. 30 (1987) 265–276.
M. HAÏDOPOULOS, F. EL FENINAT, S. TURGEON, G. LAROCHE and D. MANTOVANI. Surface modification of the 316L stainless steel for the improvement of its surface biocompatibility with an RF-plasma deposited fluorocarbon coating. in the Proceeding of “ASM Conference on Materials and Processes for Medical Devices”, Anaheim, CA, USA, (2003).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Haïdopoulos, M., Turgeon, S., Sarra-Bournet, C. et al. Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications. J Mater Sci: Mater Med 17, 647–657 (2006). https://doi.org/10.1007/s10856-006-9228-4
Received:
Accepted:
Issue Date: