Introduction

Hypertrophic cardiomyopathy (HCM) is the most common heritable cardiac single gene disorder and is the leading cause of sudden cardiac death in young individuals and athletes. It is most commonly caused by mutations in genes that encode sarcomeric proteins and is characterized by unexplained left ventricular (LV) hypertrophy (LVH) [1]. However, the penetrance of mutation and expression of LVH are incomplete, highly variable, and age dependent [2]. Genetic testing provides a certain diagnosis for HCM mutation carriers before the development of LVH that may occur in these subjects. However, it is hampered by being complex and unfeasible in up to 50 % of HCM family members as genetic mutations are only identified in 40–60 % of HCM patients [3]. Therefore, an alternative family screening approach for early diagnosis of HCM patients is required. LV diastolic dysfunction as the first marker of disease in preclinical HCM mutation carriers has been previously detected by tissue Doppler imaging (TDI) [46]. However, the reported sensitivity and specificity were highly variable. Other techniques for the early identification of myocardial systolic dysfunction and myocardial structural alteration such as two-dimensional speckle tracking echocardiography (2DSTE) and integrated backscatter echocardiography, respectively were also investigated albeit with mixed results [68].Recently, cardiac magnetic resonance (CMR) imaging with its high spatial resolution has displayed subtle myocardial structural changes [9] but also intramyocardial crypts in these mainly asymptomatic patients [10]. However the availability of CMR is limited and the analysis is time consuming. Quantification of left atrial (LA) size and function is a good diagnostic tool for LV diastolic function as well as a predictor of therapy response and major cardiovascular outcomes in various cardiac patients including HCM patients [1115]. The assessment of LA longitudinal strain using 2DSTE has recently been shown as a feasible and reproducible marker of LA function [16, 17]. Three-dimensional speckle tracking echocardiography (3DSTE) is an emerging tool building on the strengths of 2DSTE for better quantification of myocardial volumes and mechanics including assessment of dyssynchrony in one fast analysis. In this study, we tested the ability of 3DSTE to distinguish HCM mutation carriers who might develop the disease from normal subjects primarily by detecting subtle abnormalities in LA size and longitudinal strain as surrogate markers of early LV dysfunction. Likewise, we evaluated the magnitude and timing of systolic myocardial deformation to detect any abnormalities that can define early systolic dysfunction in these subjects.

Patients and methods

Patients

Based on sample size calculations, a total of 88 subjects with normal LV ejection fraction (EF) and sinus rhythm were included in the study, namely 33 patients with manifest HCM, 26 subjects with known HCM mutation carriers, and 29 normal control subjects. Manifest HCM was clinically defined as the presence of a LV maximum wall thickness (MWT) in a non-dilated LV of ≥15 mm or LV MWT of ≥13 mm as assessed by M-mode and 2DE in genotype positive patients in the absence of any systemic or other cardiac disease that could cause myocardial hypertrophy [2]. Thirty percent of the HCM patients were receiving beta-blockers and 25 %, calcium antagonists and none of them previously underwent septal reduction therapy. HCM mutation carriers were family members of HCM patients who underwent genetic testing and were found harbouring a mutation in genes encoding for any component of the sarcomere apparatus. HCM mutation carriers had LV MWT <13 mm. The normal control group (n = 29) consisted of healthy volunteers (n = 18) and healthy family members in which sarcomeric gene mutations were excluded by genetic analysis (n = 11). All HCM mutation carriers and normal controls had no history of cardiac symptoms, hypertension, diabetes or use of cardiac medication and they had normal findings on physical examination, electrocardiogram, and 2-dimensional echocardiogram. All subjects gave informed consent and the local ethics committee approved the protocol.

Echocardiographic imaging and analysis

All subjects had a complete 2DE, Doppler and TDI study using Philips iE33 with S5-1 Matrix transducer. Furthermore, they all prospectively underwent 3DSTE examination on the same sitting of the 2DE study using a commercial scanner (Artida 4D, Toshiba Medical Systems, Tokyo, Japan) with a fully sampled matrix array transducer (PST–25SX) from an apical position for both LV and LA analysis. Eight subjects (10 %) were excluded after echocardiographic acquisitions due to either poor LV image quality (defined as >4 non-visualised segments) (n = 6) or very low volume rate of acquisition (<11 vpm) (n = 2). Image quality of the LA was sufficient for all subjects and was not a reason for exclusion. In tissue harmonic mode, wide-angled acquisitions were recorded consisting of four wedge-shaped sub-volumes acquired over five consecutive cardiac cycles during a single breath-hold. While retaining the entire LV within the pyramidal volume, depth and sector width were decreased as much as possible to improve the temporal and spatial resolution of the images, resulting in a mean temporal resolution of 21 ± 3 volumes per second. Analysis of 3DSTE for the LA and LV was done as previously described [18]. The LV mass is automatically calculated after epicardial and endocardial contour detection. The obtained 3DSTE strain data for the LV included three conventional strain components (circumferential, radial and, longitudinal) as well as area strain as a novel global strain parameter. The area strain was calculated as the endocardial area change ratio throughout the cardiac cycle by giving the percentage decrease in area at LV end-systole from its original dimensions at end-diastole. Systolic dyssynchrony index (SDI%) was used to quantify the LV mechanical dyssynchrony. It was calculated as the standard deviation (SD) of the timings to peak strain of the 16 LV segments and given as a percentage of the cardiac cycle duration after normalization for the R–R duration. Peak atrial longitudinal strain (PALS) represents the maximum reservoir function of the LA where LA strain increases due to stretch by accumulating venous blood. It achieves a peak at the end of LA filling just before mitral valve opening. PALS can be used as a measure of LA relaxation and as it corresponds to the phases of LV from end-diastole to end-systole namely; LV isovolumic contraction, ejection, and isovolumic relaxation; it is sometimes described as peak LA ventricular systolic strain. During diastasis, LA strain decreases to reach a negative peak at the end of LA contraction. The 3DSTE software automatically calculates the PALS by measuring the peak positive strain from the QRS onset and averages the global PALS value from each of the 16 LA segments (Fig. 1). Other LA longitudinal strains representing the LA conduit and pump functions were not measured as they need manual calculations guided by the ECG and this would be unreliable.

Fig. 1
figure 1

Left atrial longitudinal strain analysis using 3DSTE. Tracing of the LA endocardial border is performed from the base of the LA at the mitral valve level toward the LA apex, while excluding the LA appendage and the pulmonary veins from the LA cavity. Tracing was done in apical four-chamber view (A), apical two-chamber view (B), and three short axis planes (C3, C5, C7). The frame of LV end-systole with maximum LA volume is presented for a carrier (left) and a normal control (right). The showed curves represent the segmental longitudinal strains with the coloured one showing the global longitudinal strain where the PALS is in the carrier is lower (24 %) compared to the normal control (43 %) with comparable LA volumes

Observer reliability

Observer reliability to evaluate PALS as a novel 3DSTE-derived parameter was assessed in a randomly selected number of 15 manifest HCM patients. 3DSTE data sets were analysed for inter-observer reliability by two experienced observers (M.F. and S.K.) in a blinded fashion. Intra-observer measures were performed on average 2 weeks apart in random order. The observer reliability of 3DSTE-derived LV strain components were extensively studied in a previous study that included HCM patients [18].

Statistical analysis

Continuous variables are presented as mean ± SD, whereas categorical variables are presented as frequencies and percentages. One-way analysis of variance was used to examine the differences among groups with Bonferroni’s correction for multiple pair-wise comparisons. Differences in continuous variables between two groups were analysed using the student’s t test, while a Chi square test or the Fisher exact test was used to analyze a difference in categorical variables as appropriate. Inter-observer and intra-observer reliability were measured using the intra-class correlation coefficient (ICC). To determine the ICC, different variance components were calculated using restricted maximum likelihood method of estimation and a model for absolute agreement, where the observers and patients were entered as random effects. A P value <0.05 was considered statistically significant. All data were analysed using SPSS version 20.0 (IBM SPSS Inc., Chicago, IL, USA).

Results

Baseline and echocardiographic characteristics

As displayed in Table 1, the HCM mutation carriers were well matched for age and body surface area (BSA) with the normal controls as these are important determinant of LA strain [16]. Due to the bigger BSA in manifest HCM patients, the indexed 3DSTE LA volumes, LV volumes and mass were used. There was no matching for gender between HCM carriers and normal controls. By definition, LV MWT was significantly higher in the manifest HCM group compared with other groups. For the distribution of gene mutation, myosin binding protein C3 (MYBPC3) was the most predominant mutation in both HCM mutation carriers (66 %) and manifests HCM patients (39 %). Other carriers equally had troponin T mutation (17 %) or myosin heavy chain mutation (MYH7) (17 %). Based on 2DE, the majority of manifest HCM (79 %) had no obstruction and the remaining 6 patients had fixed and/or dynamic obstruction. Eighteen patients (64 %) had asymmetrical septal hypertrophy. Both HCM mutation carriers and controls showed similar normal mitral inflow Doppler indices. However for the mitral annular TD velocities, HCM mutation carriers, compared to controls; showed significantly lower lateral and averaged Ea. In addition, HCM mutation carriers showed significantly higher lateral, septal, and averaged E/Ea as surrogates of LV filling pressure. When compared to manifest HCM patients, HCM mutation carriers showed significantly higher both lateral and averaged Sa and Ea and septal Ea as well. They also showed a significantly lower lateral, septal, and averaged E/Ea and Pulmonary capillary wedge pressure (PCWP), which is calculated by the echo machine as a surrogate of LA pressure using the Ea parameters. By applying the ROC curve analysis to test the discriminatory power of any of these statically different Doppler parameters, the area under the curve was insufficient (<0.5) to yield a good sensitivity and specificity to differentiate HCM mutation carriers from normals.

Table 1 Baseline population and echocardiographic characteristics

LA analysis

In HCM mutation carriers compared to normal controls, LA minimum volume (LAVmin) was significantly higher (17 ± 6 vs. 14 ± 4, respectively, P = 0.03) and PALS was significantly lower (27 ± 5 vs. 31 ± 7, respectively, P = 0.02) whereas the LA maximum volume (LAVmax) and LA EF did not show a significant difference as shown in Table 2 and Fig. 1. Using the ROC curve analysis to test the discriminatory power of LAVmin and PALS to differentiate HCM mutation carriers from normals, the area under the curve for both was insufficient (0.40 and 0.33, respectively) to yield a reasonable sensitivity and specificity. Compared to manifest HCM patients, HCM mutation carriers showed a significantly lower LAVmin and LAVmax and a significantly higher LAEF and PALS as shown in Table 2. When correlating 3DSTE LA parameters to the TD mitral annular velocities and L V parameters, only PALS that could show a significant moderate correlation with lateral and averaged Ea as well as LV longitudinal strain (r = 0.58, 0.63, and 0.60, P < 0.001 for all, respectively) whereas there were poor correlations between any of the mitral annular TD velocities and different LV parameters (r < 0.50).

Table 2 Global left atrial and ventricular analysis using 3DSTE

LV analysis

By comparing HCM mutation carriers to normal controls, there were no significant differences in LV volumes, LVEF or LV mass. In addition, the global LV strain parameters namely circumferential, radial, and longitudinal strain as well as area strain and their derived SDI did not differ between both groups as seen in Table 2. Furthermore, no significant differences could be detected in any of these strain parameters on a segmental level as shown in Table 3. Of note, even the basal anterior septum where hypertrophy most commonly manifests, did not show significant difference in LV strain components including the longitudinal strain (−14 ± 6 vs. −15 ± 8 %, respectively, P = 0.4).

Table 3 Regional left ventricular strain analysis using 3DSTE

Manifest HCM patients on the other hand showed a significantly lower LV end-diastolic volume and a higher LV mass compared to HCM mutation carriers as seen in Table 2. In addition, the global longitudinal strain and area strain were considerably impaired despite the presence of a normal LVEF; the global longitudinal strain was reduced by 31 % (−11 ± 4 vs. −16 ± 3 %, respectively, P < 0.001), and area strain was reduced by 13 % (−35 ± 6 vs. −40 ± 5 %, respectively, P = 0.005) as detailed in Table 2 and Fig. 2. No significant difference in the global circumferential or radial strain between both groups was found. For the assessment of mechanical dyssynchrony, only the longitudinal strain-derived SDI was significantly higher in manifest HCM patients. On a regional level, all myocardial walls had lowers longitudinal strain values particularly in the septum which was decreased by one-third (−10 ± 4 vs. −15 ± 3 %, respectively, P < 0.001). In addition, the area strain was lower in the septum and lateral walls. Regional circumferential and radial strains as well as area strain in the anterior and inferior walls were not different between both groups as in Table 3.

Fig. 2
figure 2

Left ventricular longitudinal strain analysis using 3DSTE. After 3DSTE semiautomated border detection and tracking, LV volumes, mass and EF are quantified in a manifest HCM patient (left) and a normal control (right). The showed curves represent the segmental longitudinal strains. The dashed curve represents the average strain which is lower in the manifest HCM patient (−7 %) compared to the normal control (−13 %)

Observer reliability

Inter-observer and intra-observer reliability for both LA volumes and PALS were good whereas they were moderate for LA EF as displayed in Table 4.

Table 4 Intra-observer and inter-observer reliability of LA measurements

Discussion

Echocardiography has clinical advantages, including its availability, time and cost-efficiency, and ease of use in most patients and clinical settings. 3DSTE by addressing the limitations of 2DSTE may become the technique of choice for clinical evaluation of LV and LA size and function in daily routine [1820]. Currently, there is a pressing clinical need of finding a feasible and accurate imaging tool as an alternative approach to gene testing to detect subtle abnormalities that might exist in relatives of HCM patients for the preclinical diagnosis of this serious disease, which would be of a great importance. In this regard, this is the first study using 3DSTE for the evaluation of both functional and structural changes across the entire phenotypic spectrum of HCM. The main result is that 3DSTE in HCM mutation carriers as supported by TDI findings was able to detect indirect markers of LV diastolic dysfunction in the form of an increase in LA size and a decrease in PALS. Compared to normal subjects, no significant differences in LV systolic function in this group were found.

Assessment of LA size and function

LA dilatation and the decrease in its EF have been shown to be good diagnostic signs of LV diastolic dysfunction and markers of poor prognosis of different cardiovascular diseases [17]. LA reservoir function was shown to be determined by integration of LA wall relaxation and both LV systolic and diastolic function. LA wall state should have an effect on LA relaxation and reservoir function in its early part [21, 22]. LV systolic function influences the LA reservoir function through mitral annulus descent from the LV base to apex during late systole [22]. Elevated LV end-diastolic pressure causes LA contractile dysfunction and remodelling of the LA due to increased afterload during LA contraction. This LA contractile dysfunction causes LA relaxation impairment due to the coupling present between LA systolic dysfunction and relaxation. In addition, the LA remodelling causes thickening of the LA wall. Both mechanisms end with impaired PALS [23, 24]. Measuring LA volumes by 3DSTE was shown to be a feasible and reproducible in a large study [18]. It has been demonstrated that 2DSTE-derived PALS is a feasible and reproducible marker of the LA deformation that may be more sensitive than LAEF in detecting early impairment of the LA reservoir function [16, 17]. Moreover, 3DSTE-derived LA longitudinal strain has been recently demonstrated feasible as well, and more reproducible and beneficial than 2DSTE longitudinal strain for identifying patients with paroxysmal atrial fibrillation [25]. In the present study, we used 3DSTE to study the LA volume and also PALS as a substitute of LA volume change in the evaluation of LA reservoir function in HCM as an indirect marker of both LV diastolic and systolic function.

Our results revealed that 3DSTE gives reproducible quantification of LA volumes, and PALS as a new 3DSTE-derived parameter is highly reproducible with a better reproducibility than LA EF. This data are consistent with larger feasibility studies for LA volume quantification [18] and PALS assessment [25] using 3DSTE. Our reported normal values of PALS are higher than those given by Mochizuki et al. [25] (31 ± 8 vs. 26 ± 7 %, respectively); however this could be explained by the lower mean age in our group (48 ± 15 vs. 58 ± 5 years, respectively). Both LAVmax and LAVmin were significantly dilated, and LAEF were significantly reduced in manifest HCM patients as compared to both HCM mutation carriers and normal subjects. This finding is consistent with the results of previous studies reported enlarged LAV in manifest HCM patients [11]. The reduced PALS measured by 3DSTE in our study was also similar to the reported impaired PALS measured by 2DSTE in manifest HCM patients [1215].

One of the aims of the current study was to focus on these indirect LA markers of LV impairment in the group of HCM mutation carriers. We could define a significantly dilated LAVmin and reduced PALS in this group compared to normal controls, albeit none of them was able to have a clinically applied sensitivity and specificity due to the wide overlap between their values in mutation carriers and controls. The dilated LAVmin and the decreased PALS in the HCM mutation carriers could be related to the presence of LV diastolic dysfunction as detected by TDI that might precede LV systolic dysfunction. Since the impairment of LV diastolic function in this group is subtle, the changes in the LAVmin and PALS were not evident, especially for the PALS which is mainly related to the LV systolic function which was completely preserved in this group. The LAVmin has been shown recently to be a better correlate of LV diastolic dysfunction and to be more sensitive than LAVmax. This is because the LAVmin is more directly exposed to LV pressure through an open mitral valve than LAVmax. The latter is only affected by the LV longitudinal systolic function through the systolic descent of the mitral annulus towards the apex during systole with subsequent stretch of the LA [26]. As long as both the diastolic and systolic LV impairment were more evident and long standing in the manifest HCM compared to HCM mutation carriers, the LAVmin got more dilated and the PALS became more significantly reduced. In addition, the LAVmax was dilated and the LAEF was reduced. Furthermore, this reported LA dysfunction could be due to a primary LA affection caused by the generalized myopathic process in HCM affecting both atrial and ventricular myocardium [11, 13].

Assessment of LV size and function

The histopathologic changes of the myocardium in HCM lead to both LV diastolic and systolic dysfunction. LV diastolic dysfunction is secondary to a reduction of LV compliance (increased LV mass) and increased stiffness (myocardial fibrosis) which is coupled to a decrease of ventricular volume as a contributing factor. The systolic dysfunction is due to the impaired active force generation and contractile dysfunction despite the clinically hyperdynamic systolic function secondary to decreased afterload as a result of the small LV cavity [27]. Furthermore, the observed LV dyssynchrony in our study as a significantly increased longitudinal strain-derived SDI despite normal QRS duration may be another reason for the impaired contractility and subsequent heterogeneity of relaxation and this adds to our understanding of the myocardial mechanics in HCM. The impaired long-axis function appears as a more sensitive marker for myocardial pathology and reveals earlier impairment of the cardiac function [28]. This can be explained by the fact that longitudinal function is mainly related to the subendocardial fibres which are more susceptible to the perfusion abnormalities and affected by the interstitial fibrosis [29]. In the current study, in agreement with previous studies in patients with HCM, LV diastolic dysfunction is evident [1114]. In view of systolic function assessment and compared to previous studies using 2DSTE strain [68, 3032] tagged CMR [33] and 3DSTE [34], the longitudinal strain as a representative of long-axis function was the most reduced strain parameter both globally and regionally in addition to the presence of longitudinal dyssynchrony. The significantly low radial strain observed in our study is also consistent with previous results [10, 31, 33] although one study reported a normal radial strain [7]. The results for the circumferential strain are somewhat contradictory. While in our study and similarly to others [7] it was preserved, it was decreased in others [8, 29, 30] and increased in yet another study which might be a compensatory response to maintain the systolic dysfunction [33]. The contradictory results among studies concerning their radial and circumferential LV strain values might be linked to using different echocardiography machines as recently reported by Banado et al. [35] using two different 3DSTE vendors. Our results also revealed a significantly reduced area strain which represents a global motion of deformation, not available in 2D imaging. This finding may be an evidence for the diverse phenotypic patterns of altered myocardial mechanics seen in patients with HCM.

In view of these diastolic and systolic strain abnormalities observed in manifest HCM patients, we tried to detect similar abnormalities in the carrier group. Compared to normal controls, our results revealed subtle LV diastolic dysfunction as denoted from TDI parameters in the HCM mutation carriers and this finding is consistent with the results of previous studies using different measures of LV diastolic function like Doppler mitral, pulmonary inflow, and TDI [710]. These results further support the clinical importance of the TD mitral annular velocities as an easy to perform and widely available clinical echocardiographic tool to assess the LV diastolic function. The diastolic dysfunction is assumed to be due to the intrinsic functional consequences of sarcomere mutations and the early pathologic changes in the myocardium before the development of cardiac hypertrophy. On the other hand, our results did not support the presence of any global or regional systolic strain abnormalities in those HCM mutation carriers. These negative results are consistent with prior reports used 2DSTE for the absence of global systolic impairment [68] and for the absence of regional systolic abnormalities as well [7]. However, our results differ from other studies on the regional level with regard to the involvement of the basal anterior septum. Whereas our study does not demonstrate any difference of systolic function in that region, others reported a decreased longitudinal strain using 2DSTE [6, 8] or an increased calibrated integrated backscatter using backscatter echocardiography [8]. These contradictory results in HCM mutation carriers might be explained by different gene mutations that vary with respect to their pathogenesis and age dependent penetrance [36]. Therefore, a family member who is assumed to be a mutation carrier might indeed carry a non-disease causing variant and show normal echocardiographic indices including indices of LA strain. One study compared two age-adjusted cohorts of HCM mutation carriers with the most commonly prevalent mutations, namely; MYH7 and MYBPC3. It reported that subjects with MYH7 mutations had evidence of more impaired diastolic function, but enhanced regional systolic function relative to subjects with MYBPC3 mutations. The proposed explanation given for this exaggerated myocardial contractility in regions experiencing higher longitudinal strain may be a compensatory mechanism to sarcomeric mutations that paradoxically precede the development of LVH [7]. Therefore, longitudinal studies to follow preclinical sarcomere mutation carriers over time are needed to fully describe the temporal sequence of phenotypic evolution.

Study limitations

An important limitation of the current study is the relatively small number of subjects in each group. Accordingly, comparing different types of gene mutations in the HCM mutation carriers was not possible and this precludes the universal application of these results to studies with different distribution of mutations. Absence of matching for gender between HCM carriers and normal controls remains a limitation even after adjustment for other baseline characteristics. Likewise, we could not define the effect of obstruction and the medications on the strain values in manifest HCM patients. Another limitation was that the LA was analysed using software created for LV quantification as a dedicated software package for the LA analysis has not been released yet.

Conclusions

HCM mutation carriers may be distinguished from healthy subjects using 3DSTE through detection of LA dysfunction that may indicate LV diastolic dysfunction. However, single parameters have insufficient diagnostics yield to be clinically useful on their own. Further research in a larger study population with gene-specific analysis is warranted to demonstrate the potential clinical usefulness of 3DSTE with its ongoing future development in family screening for HCM.