Abstract
Wireless telemedicine is a new and evolving area in telemedical and telecare systems. Healthcare personnel require realtime access to accurate patient data, including clinical histories, treatments, medication, tests, laboratory results and insurance information. With large-scale wireless networks and mobile computing solutions, such as cellular 3G, Wi-Fi mesh and WiMAX, healthcare personnal can tap into vital information anywhere and at any time within the healthcare networks. The recent introduction of pervasive computing, consisting of radio frequency identification (RFID), Bluetooth, ZigBee, and wireless sensor networks, further extends the potential for exploitation of wireless telecommunications and its integration into new mobile healthcare delivery systems.
In this paper, snapshots of current uses and future trends of various wireless communications in the healthcare domain are highlighted. Special attention is given to the challenges of a telemedicine environment equipped with different wireless technologies and how the resulting issues might be addressed in medical services integration to provide flexible, convenient and economical medical monitoring, consultation and healthcare.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Brown N: ’Telemedicine Coming of Age’, in Telemedicine Information Exchange (2005) — http://tie.telemed.org
Pattichis C S, Kyriacou E, Voskarides S, Pattichis M S, Istepanian R and Schizas C N: ’Wireless telemedicine systems: an overview’, Antennas and Propagation Magazine, IEEE, 44, pp 143–153 (2002)
Pavlopoulos S, Kyriacou E, Berler A, Dembeyiotis S and Koutsouris D: ’A novel emergency telemedicine system based on wireless communication technology — AMBULANCE’, IEEE Transactions on Information Technology in Biomedicine, 2, pp 261–267 (1998).
Lamprinos I E, Prentza A, Nokas G, Dermatas E, Tsoukalis A and Koutsouris D: ’Design of wireless network of sensors for continuous monitoring of vital biosignals’, in IEE Eurowearable, pp 79–85 (2003).
’To Err Is Human: Building a Safer Health System’, Committee on Quality of Health Care in America, Institute of Medicine, Washington, DC, National Academy Press (2000).
Kyriakou E, Voskarides S, Pattichis C S, Istepanian R, Pattichis M S and Schizas C N: ’Wireless Telemedicine Systems: A Brief Overview’, presented at 4th International Workshop on Enterprise Networking and Computing in the Healthcare Industry (HEALTHCOM 2002), Nancy, France (2002).
Chu Y and Ganz A: ’A mobile teletrauma system using 3G networks’, IEEE Transactions on Information Technology in Biomedicine, 8, pp 456–462 (2004).
LINCOS Website — http://www.lincos.net/
Sungmee P and Jayaraman S: ’Enhancing the quality of life through wearable technology’, Engineering in Medicine and Biology Magazine, IEEE, 22, pp 41–48 (2003).
Winters J M and Yu W: ’Wearable sensors and telerehabilitation’, Engineering in Medicine and Biology Magazine, IEEE, 22, pp 56–65 (2003).
Bonato P: ’Wearable sensors/systems and their impact on biomedical engineering’, Engineering in Medicine and Biology Magazine, IEEE, 22, pp 18–20 (2003).
Stanford V: ’Pervasive computing goes the last hundred feet with RFID systems’, Pervasive Computing, IEEE, 2, pp 9–14 (2003).
Jovanov E, Milenkovic A, Otto C and Groen P C D: ’A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation’, Journal of Neuro-Engineering and Rehabilitation, 2 (2005)
Yuan-Hsiang L, Jan I C, Ko P C I, Yen-Yu C, Jau-Min W and Gwo-Jen J: ’A wireless PDA-based physiological monitoring system for patient transport’, IEEE Transactions on Information Technology in Biomedicine, 8, pp 439–447 (2004).
Perry M, Dowdall A, Lines L and Hone K: ’Multimodal and ubiquitous computing systems: supporting independent-living older users’, IEEE Transactions on Information Technology in Biomedicine, 8, pp 258–270 (2004).
Neild I, Heatley D J T, Kalawsky R S and Bowman P A: ’Sensor networks for continuous health monitoring’, BT Technol J, 22, No 3, pp 130–139 (2004).
Cáceres C, Fernández A, and Ossowski S: ’CASCOM — Context-Aware Health-Care Service Co-ordination in Mobile Computing Environments’, ERCIM News, 60, pp 77–78 (2005).
Schrenker R and Cooper T: ’Building the foundation for medical device plug-and-play interoperability’, Medical Electronics Manufacturing, pp 10 (April 2001).
Golmie N, Cypher D and Rebala O: ’Performance analysis of low rate wireless technologies for medical applications’, Computer Communications, 28, pp 1266–1275 (2005).
Tri J L, Severson R P, Firl A R, Hayes D L and Abenstein J P: ’Cellular Telephone Interference With Medical Equipment’, Mayo Clinic Proceedings, 80, pp 1286–1290 (2005).
Nortel Networks Ltd: ’Nortel Expands Taipei Mesh’, (2005) — http://www.unstrung.com/document.asp?doc_id=74884
About this article
Cite this article
Ng, H.S., Sim, M.L., Tan, C.M. et al. Wireless technologies for telemedicine. BT Technol J 24, 130–137 (2006). https://doi.org/10.1007/s10550-006-0050-9
Issue Date:
DOI: https://doi.org/10.1007/s10550-006-0050-9