Abstract
After an earthquake, the failure of suspended ceiling systems is one of the most widely reported types of nonstructural damage in building structures. Since suspended ceiling systems are not amenable to traditional structural analysis, full-scale experimental testing is planned and executed. In particular, shaking table tests are performed in order to investigate the seismic behaviour of plasterboard continuous suspended ceilings under strong earthquakes. Two kinds of ceiling systems, named single frame ceiling and double frame ceiling, are tested. A steel test frame is properly designed in order to simulate the seismic effects at a generic building storey. A set of five accelerograms, used as input for the shakings, are selected matching the target response spectrum provided by the U.S. code for nonstructural components. Three limit states (occupancy, damage and life safety limit state) are considered in this study in order to characterize the seismic response of suspended ceiling systems. The tested ceilings show no damage at all intensity levels, evidencing a low fragility. Three main aspects may be the cause of this low vulnerability: (a) the continuous nature of the tested ceilings; (b) the dense steel channel grid that supports the plasterboard panels; (c) the large number of hangers that connects the ceiling system to the roof, avoiding any vertical movement of the ceilings. Finally, an interesting comparison is made with a previous vulnerability study on a different typical U.S. ceiling system.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
ANCO Engineers Inc. (1983) Seismic Hazard Assessment of Nonstructural Ceiling Components, NSF Rep. No. CEE-8114155, Culver City, CA, USA
ANCO Engineers Inc. (1993) Earthquake testing of a suspended ceiling system, Culver City, CA, USA
Badillo-Almaraz H, Whittaker AS, Reinhorn AM, Cimellaro GP (2006) Seismic Fragility of Suspended Ceiling Systems, Report MCEER-06-0001, MCEER/SUNY/Buffalo
Badillo-Almaraz H, Whittaker AS, Reinhorn AM (2007) Seismic fragility of suspended ceiling systems. Earthq Spectra 23(1): 21–40
CEN (2005a) Eurocode 3: design of steel structures—part 1–1: general rules and rules for buildings. EN 1993-1-1. Brussels, Belgium
CEN (2005b) Eurocode 3: design of steel structures—part 1–8: design of joints. EN 1993-1-8. Brussels, Belgium
CEN (2004) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings. EN 1998-1, Brussels, Belgium
Computers and Structures, Inc. (2010) SAP 2000: Linear and Nonlinear Static and Dynamic Analysis of Three Dimensional Structures, Berkeley, California, USA
EERI (1984) Nonstructural issues of seismic design and construction, Publication 84-04, Earthquake Engineering Research Institute, Berkeley, CA, USA
Gilani ASJ, Reinhorn AM, Glasgow B, Lavan O, Miyamoto HK (2010) Earthquake simulator testing and seismic evaluation of suspended ceilings. ASCE/J Archit Eng 16(2): 63–73
Gilani ASJ, Takhirov S, Reinhorn A, Mahin SA (2010b) Seismic Qualification testing of suspended ceilings: lessons learned and the requirements for a new test standard and qualification procedure. 2010 Structures Congress, Orlando, Florida, USA
Hancock J, Watson-Lamprey J, Abrahamson NA, Bommer JJ, Markatis A, McCoy E, Mendis R (2006) An improved method of matching response spectra of recorded earthquake ground motion using wavelets. J Earthq Eng Special Issue 10(1):67–89. doi:10.1080/13632460609350629
International Conference of Building Officials (ICBO) (2000) ICBO AC 156 acceptance criteria for the seismic qualification of nonstructural components. ICBO Evaluation Service, Inc., Whittier
Maddaloni G, Ryu KP, Reinhorn AM (2010) Simulation of floor response spectra in shake table experiments. Earthq Eng Struct Dyn 40(6):591–604. doi:10.1002/eqe.1035
Magliulo G, Manfredi G (2011) Shake table tests for analysis of the seismic performances of Lafarge pregymetal ceilings. Report 2010078-01, Department of Structural Engineering, University of Naples Federico II, Italy
Magliulo G, Pentangelo V, Manfredi G (2009) Danneggiamento delle controsoffittature a seguito del terremoto dell’Aquila dell’aprile 2009 V1.00, available on http://www.reluis.it (in Italian)
McCormick J, Matsuoka Y, Pan P, Nakashima M (2008) Evaluation of non-structural partition walls and suspended ceiling systems through a shake table study. In: Proceedings of the 2008 structures congress, Vancouver, Canada. doi:10.1061/41016(314)223
Miranda E, Aslani H, Taghavi S (2004) Assessment of seismic performance in terms of economic losses. In: Bled ‘04 International workshop on performance-based seismic design, June 28–July 1, Bled, Slovenia
Rihal S, Granneman G (1984) Experimental Investigation of the Dynamic Behavior of Building Partitions and Suspended Ceilings During Earthquakes, Rep. No. ARCE R84-1, California Polytechnic State University, Pomona, CA, USA
Taghavi S, Miranda E (2003) Response assessment of nonstructural building elements, PEER report 2003/05, College of Engineering, University of California Berkeley, USA
Villaverde R (1997) Seismic design of secondary structures: state of the art. J Struct Eng 123(8):1011–1019
Yao GC (2000) Seismic performance of direct hung suspended ceiling systems. J Archit Eng 6(1): 6–11
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Magliulo, G., Pentangelo, V., Maddaloni, G. et al. Shake table tests for seismic assessment of suspended continuous ceilings. Bull Earthquake Eng 10, 1819–1832 (2012). https://doi.org/10.1007/s10518-012-9383-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10518-012-9383-6